• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] STUDY OF DRYING-WETTING EFFECTS OU THE SHEAR STRENGTH OF A SOIL COMPACTED IN LABORATORY / [pt] ESTUDO DOS EFEITOS DE UMEDECIMENTO E SECAGEM NA RESISTÊNCIA AO CISALHAMENTO DE UM SOLO COMPACTADO EM LABORATÓRIO

RODRIGO MARQUES BENEVELI 09 May 2002 (has links)
[pt] No presente trabalho, pretende-se avaliar os efeitos de ciclos de umedecimento e secagem na resistência ao cisalhamento do solo. Este estudo é de grande importância, particularmente,para os solos brasileiros, já que se encontram em uma região tropical, onde verifica-se a ocorrência de períodos bem definidos de chuvas e estiagem. Sabe-se que, longos períodos de chuvas podem saturar o solo, assim como durante a estiagem,pode ocorrer uma maior evaporação do que infiltração de água, o que leva o solo a uma condição não saturada, provocando o surgimento de uma nova componente de resistência, a coesão aparente. Na natureza, estes dois períodos não ocorrem de maneira uniforme, fazendo com que o solo atinja valores de sucção diferentes, dependendo do seu umedecimento e secagem. Assim sendo, ciclos de umedecimento e secagem e o nível de sucção atingido correspondente, podem afetar o comportamento mecânico do solo. Afim de verificar a influência de tais ciclos de umedecimento e secagem, determinou-se a resistência ao cisalhamento do solo, por meio de ensaios de cisalhamento direto com sucção controlada no equipamento desenvolvido na PUC-Rio. O umedecimento e a secagem do solo,foram simulados, em laboratório, através da diminuição e aumento da sucção, respectivamente. Utilizou-se o solo maduro do campo experimental II da PUC-Rio, peneirado e compactado em laboratório.Foram realizadas várias séries de ensaios, em que se modificavam os procedimentos realizados em relação aos níveis de sucção aplicados. A partir dos resultados obtidos,verificou-se a influência dos ciclos de umedecimento e secagem e dos níveis de sucção atingidos em cada caso, na resistência ao cisalhamento do solo, bem como na variação de volume total e de água nas amostras, durante o cisalhamento. / [en] This work intends to evaluate the effects of wetting and drying cycles on soil shear strength. It is a study of great importance, specially for brazilian soils, since they are found in a tropical area, where there are periods well defined of raining and dryness.It is well known that long raining periods can saturate the soil, as well as during dryness it can occur a bigger evaporation than infiltration of water, what brings soil to an unsaturated state. Unsaturated soils have an additional strength component: the apparent cohesion. In nature, raining and dryness do not occur uniformly, because of that, the soil suction can reach different values, depending on its wetting and drying, thus being, wetting and drying cycles and the corresponding suction levels can affect the mechanical behaviour of soil.Aiming at verify the influence of such cycles of wetting and drying, soil shear strength was obtained through laboratory tests of direct shear with controlled suction, using PUC-Rio s developed equipment. Soil wetting and drying had been simulated in laboratory, reducing and increasing suction. Mature soil brought from the experimental field II of PUC-Rio, sifted and compact in laboratory, was used.Many series of laboratory tests had been carried out, modifying procedures related to applied suction levels. From the gotten results the influence, of wetting and drying cycles and reached levels of suction, was verified. Such influence also occurred, on total and water volume changes, during the shear.
2

Análise e modelagem do comportamento colapsível de um solo arenoso / Analysis and modeling of the collapse behavior of a sandy soil

Davies, Guilherme Izidório 31 July 2000 (has links)
Muitas são as pesquisas que avaliam as variáveis intervenientes no colapso dos solos: contudo, pouco tem sido publicado a respeito da influência da trajetória de ciclos de umedecimento e secagem, no comportamento colapsível do solo, e do colapso em condições de carregamento triaxial. O presente trabalho tem como objetivo estudar o colapso de um solo arenoso, típico da região centro-oeste do Estado de São Paulo, frente a tais variáveis através de ensaios edométricos convencionais, edométricos com controle de sucção e triaxiais. Dos ensaios edométricos convencionais caracterizou-se o colapso sob vários níveis de tensão, determinando assim a sobrecarga de inundação que causa máximo colapso. Nos ensaios de compressão triaxial, cada amostra foi inundada sob um determinado estado de tensão, caracterizado pela relação &#9631/&#9633. Nestes ensaios foi observado que as deformações volumétricas são dependentes da tensão confinante e da relação &#9631/&#9633, e que as deformações axiais por colapso são menores que as medidas nos ensaios edométricos convencionais. Nos ensaios edométricos com sucção controlada verificou-se que o valor inicial da sucção apresenta influência no valor do colapso total. Quanto aos ciclos de umedecimento e secagem, o solo sofreu colapso insignificante quando a sucção foi reduzida a um mesmo valor pela segunda vez. Os resultados experimentais dos ensaios edométricos com sucção controlada foram então modelados de acordo com o modelo de ALONSO et. al, (1990), e as adaptações a esse modelo propostas por FUTAI (1997) e MACHADO (1998), verificando-se a capacidade de cada formulação em representar matematicamente o comportamento colapsível do solo estudado. / There are many researches that evaluate and discuss the factors which interfere in the collapse of soils. However, not many have been published regarding the influence of the cycles of wetting in the collapsible behavior of the soil, and neither have collapse strains under triaxial load. The present work deals with the collapse behavior of a sandy soil, typical from the center-west of the State of São Paulo, considering the aforesaid aspects and using conventional oedometer, suction controlled oedometer and triaxial compression tests. In conventional oedometer tests, the influence of overburden stress on the induced wetting on collapse strains was characterized. Collapse strains were also measured in triaxial compression tests, varying the ratio of principal stress (&#9631/&#9633) when the samples are inundated. It was observed that collapse volumetric strains are dependent on confining stress and on &#9631/&#9633, and that, axial and radial strains are related to the ratio of &#9631/&#9633. The axial collapse strains observed in triaxial compression tests were shown to be lower than the ones measured in conventional oedometer tests. In controlled suction tests, the amount of collapse strains under gradual suction reduction was studied including the influence of suction reversals. It was noted that the initial suction influences the amount of collapse strains, and that, in the cycles of wetting and drying, the strains after the second cycle tended to be negligible. Experimental results from suction controlled oedometer tests were modeled through the model by ALONSO et. al. (1990) and by the adaptations to this model proposed by FUTAI (1997) and MACHADO (1998).
3

Avaliação experimental da influência do avanço do umedecimento no comportamento de muros de solos finos reforçados com geotêxteis não tecidos / Experimental evaluation of the wetting advancement effect on the performance of nonwoven geotextile reinforced soil walls with fine soil

Portelinha, Fernando Henrique Martins 28 September 2012 (has links)
O presente trabalho consiste na avaliação experimental da influência do avanço da frente de umedecimento no comportamento de protótipos de muros de um solo fino reforçado com geotêxteis não tecidos. O desempenho dos protótipos foi analisado nas condições de eventos de chuvas de intensidade e duração variáveis, bem como na condição de precipitação intermitente com intensidade próxima e inferior à condutividade hidráulica do solo. Para efeito comparativo, avaliou-se o comportamento de um protótipo na condição de umidade de compactação constante. Durante a infiltração, observou-se a formação de barreira capilar sobre o geotêxtil e a eficiência de drenagem proporcionada pelos reforços, não permitindo o desenvolvimento de pressões da água positivas mesmo sob a condição de carregamento rápido. Após quebra da barreira, os valores de grau de saturação mantiveram-se em torno de 90% e as pressões da água ficaram próximas de zero ou negativas. Com relação ao comportamento dos protótipos, evidências mostraram que a formação de barreiras capilares nas interfaces solo-geotêxteis não influenciou negativamente no desempenho dos protótipos. Diante do umedecimento, as deformações e deslocamentos máximos aumentaram exponencialmente com o grau de saturação do solo. Ainda, estes parâmetros relacionaram-se com a sucção matricial de forma semelhante à tendência estabelecida na curva retenção de água do solo. Tais relações foram estritamente associadas às alterações da rigidez média do solo devido ao avanço da infiltração e as alterações na sucção do solo. Na condição umidade constante, constatou-se que o maciço poderia se manter estável mesmo com a ausência dos reforços devido à elevada rigidez proporcionada pela sucção do solo. De modo geral, os deslocamentos e deformações foram relativamente pequenos sob a ação da variável umedecimento. A associação desta com os incrementos de tensões geraram deformações adicionais, embora estas ainda não possam ser consideradas excessivas. Os resultados de uma estrutura real corroboraram o comportamento verificado em laboratório. De modo geral, os níveis de deformações foram bastante semelhantes e a presença de água não prejudicou o desempenho da estrutura. Curiosamente, geotêxteis não tecidos de baixa resistência e rigidez à tração foram tão eficazes na estabilidade quanto geotêxteis tecidos de maior rigidez e resistência. Portanto, a eficiência de estruturas de solos finos reforçados com geotêxteis não tecidos foi constatada, mostrando estas possíveis de compor estruturas permanentes. / The effect of the wetting front advancement on the performance of nonwoven geotextile reinforced soil walls constructed with poorly draining soils was evaluated by laboratory full scale models. The tested models performances were monitored under rainfall conditions with different intensities and duration, as well as under intermittent precipitation with reduced intensity of precipitation (lower than the soil permeability). For comparison purposes, an evaluation of a full scale model was conducted with constant soil water content (compaction water content). As regards infiltration, capillary barrier formation have been observed on the interface soil-geotextile during infiltration process; besides, the drainage function of reinforcements after the breakthrough of water, in which water pressures development have not been allowed to occur even after rapid loading. After breakthrough of water, the degree of saturation was maintained around 90% and water pressures were negatives and close to zero. Besides, there are evidences that capillary barriers did not affect the model performance. As a result of wetting advancement, reinforcement strains and internal displacements have increased exponentially with the average of degree saturation of soil. Additionally, these parameters have shown to be correlated to the matric suction of soil with the same trend of the water retention curve. These relationships are essentially resulted from the soil stiffness alterations due to the wetting advancement and suction reduction. Under water content of compaction, reinforcement tensile forces were approximately zero, as a result of the relatively high stiffness of the unsaturated soil caused by the matric suction. Generally, displacements and reinforcement strains were small under wetting conditions and increased when stress increments were applied. However, these strains levels obtained cannot be considered excessive. A validation of laboratory results was observed in an instrumented geotextile reinforced soil wall, in addition to the comparison between woven and nonwoven geotextile sections, in which similar performances were found. Strains levels registered in field were consistent to the laboratory and the nonwoven geotextile wall was not affected by the wetting occurrence. Therefore, the efficiency of nonwoven geotextiles reinforced walls under wetting conditions is assured with no positive water pressures and relatively low levels of degree of saturation, being able to constitute permanent reinforced walls.
4

Avaliação experimental da influência do avanço do umedecimento no comportamento de muros de solos finos reforçados com geotêxteis não tecidos / Experimental evaluation of the wetting advancement effect on the performance of nonwoven geotextile reinforced soil walls with fine soil

Fernando Henrique Martins Portelinha 28 September 2012 (has links)
O presente trabalho consiste na avaliação experimental da influência do avanço da frente de umedecimento no comportamento de protótipos de muros de um solo fino reforçado com geotêxteis não tecidos. O desempenho dos protótipos foi analisado nas condições de eventos de chuvas de intensidade e duração variáveis, bem como na condição de precipitação intermitente com intensidade próxima e inferior à condutividade hidráulica do solo. Para efeito comparativo, avaliou-se o comportamento de um protótipo na condição de umidade de compactação constante. Durante a infiltração, observou-se a formação de barreira capilar sobre o geotêxtil e a eficiência de drenagem proporcionada pelos reforços, não permitindo o desenvolvimento de pressões da água positivas mesmo sob a condição de carregamento rápido. Após quebra da barreira, os valores de grau de saturação mantiveram-se em torno de 90% e as pressões da água ficaram próximas de zero ou negativas. Com relação ao comportamento dos protótipos, evidências mostraram que a formação de barreiras capilares nas interfaces solo-geotêxteis não influenciou negativamente no desempenho dos protótipos. Diante do umedecimento, as deformações e deslocamentos máximos aumentaram exponencialmente com o grau de saturação do solo. Ainda, estes parâmetros relacionaram-se com a sucção matricial de forma semelhante à tendência estabelecida na curva retenção de água do solo. Tais relações foram estritamente associadas às alterações da rigidez média do solo devido ao avanço da infiltração e as alterações na sucção do solo. Na condição umidade constante, constatou-se que o maciço poderia se manter estável mesmo com a ausência dos reforços devido à elevada rigidez proporcionada pela sucção do solo. De modo geral, os deslocamentos e deformações foram relativamente pequenos sob a ação da variável umedecimento. A associação desta com os incrementos de tensões geraram deformações adicionais, embora estas ainda não possam ser consideradas excessivas. Os resultados de uma estrutura real corroboraram o comportamento verificado em laboratório. De modo geral, os níveis de deformações foram bastante semelhantes e a presença de água não prejudicou o desempenho da estrutura. Curiosamente, geotêxteis não tecidos de baixa resistência e rigidez à tração foram tão eficazes na estabilidade quanto geotêxteis tecidos de maior rigidez e resistência. Portanto, a eficiência de estruturas de solos finos reforçados com geotêxteis não tecidos foi constatada, mostrando estas possíveis de compor estruturas permanentes. / The effect of the wetting front advancement on the performance of nonwoven geotextile reinforced soil walls constructed with poorly draining soils was evaluated by laboratory full scale models. The tested models performances were monitored under rainfall conditions with different intensities and duration, as well as under intermittent precipitation with reduced intensity of precipitation (lower than the soil permeability). For comparison purposes, an evaluation of a full scale model was conducted with constant soil water content (compaction water content). As regards infiltration, capillary barrier formation have been observed on the interface soil-geotextile during infiltration process; besides, the drainage function of reinforcements after the breakthrough of water, in which water pressures development have not been allowed to occur even after rapid loading. After breakthrough of water, the degree of saturation was maintained around 90% and water pressures were negatives and close to zero. Besides, there are evidences that capillary barriers did not affect the model performance. As a result of wetting advancement, reinforcement strains and internal displacements have increased exponentially with the average of degree saturation of soil. Additionally, these parameters have shown to be correlated to the matric suction of soil with the same trend of the water retention curve. These relationships are essentially resulted from the soil stiffness alterations due to the wetting advancement and suction reduction. Under water content of compaction, reinforcement tensile forces were approximately zero, as a result of the relatively high stiffness of the unsaturated soil caused by the matric suction. Generally, displacements and reinforcement strains were small under wetting conditions and increased when stress increments were applied. However, these strains levels obtained cannot be considered excessive. A validation of laboratory results was observed in an instrumented geotextile reinforced soil wall, in addition to the comparison between woven and nonwoven geotextile sections, in which similar performances were found. Strains levels registered in field were consistent to the laboratory and the nonwoven geotextile wall was not affected by the wetting occurrence. Therefore, the efficiency of nonwoven geotextiles reinforced walls under wetting conditions is assured with no positive water pressures and relatively low levels of degree of saturation, being able to constitute permanent reinforced walls.
5

Análise e modelagem do comportamento colapsível de um solo arenoso / Analysis and modeling of the collapse behavior of a sandy soil

Guilherme Izidório Davies 31 July 2000 (has links)
Muitas são as pesquisas que avaliam as variáveis intervenientes no colapso dos solos: contudo, pouco tem sido publicado a respeito da influência da trajetória de ciclos de umedecimento e secagem, no comportamento colapsível do solo, e do colapso em condições de carregamento triaxial. O presente trabalho tem como objetivo estudar o colapso de um solo arenoso, típico da região centro-oeste do Estado de São Paulo, frente a tais variáveis através de ensaios edométricos convencionais, edométricos com controle de sucção e triaxiais. Dos ensaios edométricos convencionais caracterizou-se o colapso sob vários níveis de tensão, determinando assim a sobrecarga de inundação que causa máximo colapso. Nos ensaios de compressão triaxial, cada amostra foi inundada sob um determinado estado de tensão, caracterizado pela relação &#9631/&#9633. Nestes ensaios foi observado que as deformações volumétricas são dependentes da tensão confinante e da relação &#9631/&#9633, e que as deformações axiais por colapso são menores que as medidas nos ensaios edométricos convencionais. Nos ensaios edométricos com sucção controlada verificou-se que o valor inicial da sucção apresenta influência no valor do colapso total. Quanto aos ciclos de umedecimento e secagem, o solo sofreu colapso insignificante quando a sucção foi reduzida a um mesmo valor pela segunda vez. Os resultados experimentais dos ensaios edométricos com sucção controlada foram então modelados de acordo com o modelo de ALONSO et. al, (1990), e as adaptações a esse modelo propostas por FUTAI (1997) e MACHADO (1998), verificando-se a capacidade de cada formulação em representar matematicamente o comportamento colapsível do solo estudado. / There are many researches that evaluate and discuss the factors which interfere in the collapse of soils. However, not many have been published regarding the influence of the cycles of wetting in the collapsible behavior of the soil, and neither have collapse strains under triaxial load. The present work deals with the collapse behavior of a sandy soil, typical from the center-west of the State of São Paulo, considering the aforesaid aspects and using conventional oedometer, suction controlled oedometer and triaxial compression tests. In conventional oedometer tests, the influence of overburden stress on the induced wetting on collapse strains was characterized. Collapse strains were also measured in triaxial compression tests, varying the ratio of principal stress (&#9631/&#9633) when the samples are inundated. It was observed that collapse volumetric strains are dependent on confining stress and on &#9631/&#9633, and that, axial and radial strains are related to the ratio of &#9631/&#9633. The axial collapse strains observed in triaxial compression tests were shown to be lower than the ones measured in conventional oedometer tests. In controlled suction tests, the amount of collapse strains under gradual suction reduction was studied including the influence of suction reversals. It was noted that the initial suction influences the amount of collapse strains, and that, in the cycles of wetting and drying, the strains after the second cycle tended to be negligible. Experimental results from suction controlled oedometer tests were modeled through the model by ALONSO et. al. (1990) and by the adaptations to this model proposed by FUTAI (1997) and MACHADO (1998).

Page generated in 0.0588 seconds