1

Compensação de desequilíbrios em redes trifásicas a quatro fios utilizando dispositivos híbridos /

Nunes de Oliveira, Rodrigo Alessandro January 2017 (has links)
Orientador: Luis Carlos Origa de Oliveira / Resumo: Em sistemas trifásicos de potência as tensões entregues pela fonte são senoidais, iguais em magnitude e com defasamento angular de 120° entre fases. Contudo, as tensões resultantes nos pontos de utilização podem ser desbalanceadas por diversas razões. A natureza do desbalanceamento inclui magnitudes, e/ou diferentes defasagens angulares, entre fases das tensões. Nos sistemas de distribuição de energia elétrica são encontradas as maiores causas para geração de desequilíbrios de tensão, devido à distribuição irregular de cargas por fase, as quais variam constantemente devido à inserção e/ou retirada das mesmas. Visando a implantação de dispositivos de compensação de desequilíbrios que utilizem o menor número de componentes eletrônicos, apresentem mecanismos de controle simplificados e que sejam menos sensíveis a distúrbios na rede elétrica, apresenta-se um arranjo topológico como contribuição original deste trabalho. Destaca-se que o arranjo proposto atende às prerrogativas preconizadas e nestas condições, vislumbra-se um desempenho operacional robusto e a custo reduzido quando comparado às demais estruturas de compensação em utilização. / Doutor
2

Compensação de desequilíbrios em redes trifásicas a quatro fios utilizando dispositivos híbridos / Imbalances compensation in three-phase four-wire networks using hybrid devices

Oliveira, Rodrigo Alessandro Nunes de [UNESP] 08 September 2017 (has links)
Submitted by Rodrigo Nunes de Oliveira null (nunes@dee.feis.unesp.br) on 2017-11-07T02:42:04Z No. of bitstreams: 1 Tese_Final.pdf: 3257259 bytes, checksum: f7d500d399ebd96ac7ee61eb843aa8dd (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-11-13T19:49:42Z (GMT) No. of bitstreams: 1 nunesoliveira_ra_dr_ilha.pdf: 3257259 bytes, checksum: f7d500d399ebd96ac7ee61eb843aa8dd (MD5) / Made available in DSpace on 2017-11-13T19:49:42Z (GMT). No. of bitstreams: 1 nunesoliveira_ra_dr_ilha.pdf: 3257259 bytes, checksum: f7d500d399ebd96ac7ee61eb843aa8dd (MD5) Previous issue date: 2017-09-08 / Em sistemas trifásicos de potência as tensões entregues pela fonte são senoidais, iguais em magnitude e com defasamento angular de 120° entre fases. Contudo, as tensões resultantes nos pontos de utilização podem ser desbalanceadas por diversas razões. A natureza do desbalanceamento inclui magnitudes, e/ou diferentes defasagens angulares, entre fases das tensões. Nos sistemas de distribuição de energia elétrica são encontradas as maiores causas para geração de desequilíbrios de tensão, devido à distribuição irregular de cargas por fase, as quais variam constantemente devido à inserção e/ou retirada das mesmas. Visando a implantação de dispositivos de compensação de desequilíbrios que utilizem o menor número de componentes eletrônicos, apresentem mecanismos de controle simplificados e que sejam menos sensíveis a distúrbios na rede elétrica, apresenta-se um arranjo topológico como contribuição original deste trabalho. Destaca-se que o arranjo proposto atende às prerrogativas preconizadas e nestas condições, vislumbra-se um desempenho operacional robusto e a custo reduzido quando comparado às demais estruturas de compensação em utilização. / In three-phase power systems, the voltages delivered by the source are sinusoidal, has equal magnitudes and 120° angular phase difference between phases. However, the resulting voltages at the consumer points may be unbalanced for several reasons. The nature of the imbalance includes different magnitudes, and/or angular phase shift, between the phases of the voltages. In electrical power distribution systems, the greatest cause for voltage unbalances are due to the irregular distribution of loads per phase, which vary constantly due to the load insertion and/or removal. With the aim of implementing a unbalance compensation device that use the least number of electronic components, has a simplified control technique and are less sensitive to electrical network disturbances, a topological arrangement is presented as the original contribution of this work. It should be noted that the proposed arrangement meets the intended prerogatives and, under these conditions, it is possible to foresee a robust and low operational-cost performance, when compared to the other compensation structures already in use.
3

Power quality improvements in 25kV 50 Hz railway substation based on chopper controlled impedances / Amélioration de la qualité de l'energie electrique dans les sous stations ferroviaires 25kV 50Hz en utilisant des Impedances Controlees par Gradateur MLI

Raimondo, Giuliano 02 February 2012 (has links)
Ce travail est le résultat d'une collaboration entre le laboratoire LAPLACE, la "Seconda Università degli Studi di Napoli" (SUN) et la Société National des Chemins de fer Français SNCF. Le sujet de recherche concerne l'utilisation de dispositifs électroniques de puissance dans les sous stations ferroviaires 25kV/50Hz afin d’améliorer la qualité de l'énergie électrique. Dans le transport ferroviaire, le système d'électrification monophasé 25kV/50Hz est largement diffusé en particulier pour les lignes ferroviaires à grande vitesse. Bien qu'aujourd'hui les systèmes d’alimentation en courant continu soient encore largement utilisés, l'adoption du courant alternatif monophasé offre des avantages économiques pour les infrastructures d'environ 30% en termes d'investissement, d'exploitation et d'entretien. Initialement, compte tenu de la simplicité du circuit, il n'y avait aucune nécessité d'intégrer de l'électronique de puissance dans les sous stations. Toutefois, au cours de la décennie passée, l'intérêt pour ces équipements est apparu car ils peuvent apporter une solution d'optimisation du réseau lorsque le trafic augmente ou lorsqu’une nouvelle sous station est envisagée. Deux principaux types de dispositifs sont installés aujourd'hui sur le réseau ferré français : les compensateurs de puissance réactive et les compensateurs de déséquilibre de tension. Cette thèse présente de nouvelles topologies de compensateurs basées sur le concept d’impédances contrôlées par gradateur MLI. Comparées aux solutions existantes, ces topologies ont des caractéristiques particulièrement intéressantes en termes de pertes dans les semi-conducteurs et de volume des composants réactifs. Le manuscrit contient trois parties principales: La première partie présente le principe de l’électrification en 25kV/50Hz et souligne l’intérêt d’installer des moyens de compensation statique dans les sous stations. Après une description des solutions actuellement utilisées, le concept d’impédance contrôlée par gradateur MLI (CCI : Chopper Controlled Impedance ) est ensuite présenté. La deuxième partie du travail concerne l'utilisation du concept de CCI pour la compensation de puissance réactive. La sous-station SNCF de Revest est considérée comme cas d’étude. Celle-ci est équipée d'un transformateur monophasé de 60MVA dont le primaire est connecté à une ligne de transport 225kV. Deux topologies de compensateur de puissance réactive, basées sur des montages abaisseur ou élévateur de tension sont présentées. Le dimensionnement des gradateurs est effectué sur la base d'une campagne de mesures réalisée à la sous station. Des simulations numériques utilisant des formes d’ondes réelles de courant et de tension sont présentées. Des résultats expérimentaux effectués à la plateforme de test de la SNCF sur un prototype de 1,2MVAR permettent de valider le concept de CCI. La dernière partie du travail concerne le problème du déséquilibre de tension en amont de la sous station. Un circuit de Steinmetz « actif », toujours basée sur des gradateurs MLI, est présenté et étudié. La sous station SNCF d'Evron est alors considérée comme cas étude. Celle-ci comporte un transformateur de 32MVA et est connectée à une ligne de transmission 90kV. Les mesures effectuées sur le site permettent le dimensionnement du compensateur ainsi que l’utilisation des formes d'onde réelles de courant et de tension dans les simulations numériques. Une comparaison avec des solutions classiques basées sur des onduleurs 2 niveaux et 3 niveaux souligne les avantages de la solution proposée. Ainsi, les résultats des calculs et des simulations montrent que l'énergie stockée dans les éléments réactifs est réduite d’un facteur six et que les pertes dans les semi-conducteurs sont réduites de 40%. Des résultats expérimentaux obtenus sur une maquette de 1.5 kVA permettent de valider le principe du circuit de Steinmetz actif. / This work is the result of collaboration between the LAPLACE laboratory, the “Seconda Università degli Studi di Napoli” (SUN) and the French national railways operator SNCF. The research topic treated herein concerns the use of power electronic devices in 25kV/50Hz railways substations to achieve power quality improvements. In railway transportation, single-phase 25kV-50Hz electrification system is widely diffused especially for high-speed railway applications. Although electrified DC systems are still widely applied, the adoption of AC single-phase system offers economical advantages for the infrastructures of about 30% in terms of investment, exploitation and maintenance. In early ages, due to its very simple diagram, there was no necessity to integrate power electronics in substations. However, for the last decade, the interest in power electronic equipments raised since they can provide the solution for network optimization when traffic increases or when a difficulty is foreseen for a substation implementation. Two types of devices are implemented today on the French Railway Network: Reactive Power compensators and Voltage Unbalance compensators. This thesis presents an investigation into new topologies based on the concept of “Chopper Controlled Impedances”(CCI). Compared to existing solutions, the new topologies show interesting features in terms of semi-conductor losses reduction and volume of reactive components. The manuscript is developed through three main parts: Firstly, the French railways system is introduced and the interest in installing power electronic compensators in substations is highlighted. After a brief description of currently used solutions, the CCI concept is presented: the use of Pulse Width Modulated AC Choppers allows achieving structures which behave as variable impedances. In the second part, the use of CCI structures in reactive power compensation is investigated. The SNCF substation of Revest is under study. It is equipped by a 60MVA single phase transformer with the primary side connected to a 225kV transmission line. Based on the step-down or step-up functioning mode of CCIs, two topologies of reactive power compensator are presented. The converter design is developed on the base of a measurement campaign carried out at the substation. Numerical simulations using real current and voltage waveforms are presented. Finally, experimental results carried out at the SNCF test platform on a 1.2MVAR prototype are shown. In the last part, the problem of voltage unbalance is treated. Using the concept of CCI, the feasibility of an active Steinmetz circuit based on AC choppers is explored. As a case study, the substation of Evron is considered. It is a 32MVA substation connected to a 90kV transmission line. Measurements carried out on the substation site allow the compensator design and the possibility to consider real waveforms for current and voltage in numerical simulations. A comparison with classical solution based on two levels VSI and three levels NPC-VSI highlights the advantages of the proposed solution. Calculation and simulation results show that the stored energy in reactive elements is reduced by a factor six whereas the semiconductor losses are 40% lower. Experimental results obtained on a scaled demonstrator (1.5 kVA) validate the principle of the active Steinmetz circuit.
4

Contribuições para o balanceamento eletrônico de rotores. / Contributions to active unbalance comprensation of rotors.

Yuri Perim 23 August 2018 (has links)
Este trabalho se insere no contexto de redução de vibrações de rotores via mancais ativos. Essas vibrações são causadas pelo desbalanço do próprio rotor e possuem frequência igual à frequência de rotação desse rotor. O desbalanço pode ser modelado como uma força de perturbação girante, sendo que uma técnica bastante conhecida para anular o efeito dessa perturbação é o balanceamento eletrônico, também chamado de compensação síncrona de desbalanço ou de regulação sincronizada. A presente dissertação traz duas contribuições para o tema. A primeira é a simplificação do compensador síncrono através de considerações de simetria do rotor e de isotropia dos mancais, e a segunda é a obtenção do modelo exato do sistema discreto resultante da aplicação da metodologia de compensação síncrona. Tais contribuições se valem da descrição do modelo em coordenadas complexas. À transformação de coordenadas reais para coordenadas complexas deu-se o nome de complexificação. Assim sendo, a complexificação do modelo permite dividir por dois a dimensão das variáveis do sistema (estados, entradas e saídas), além de dar sentido físico à separação entre os distúrbios diretos (caso do desbalanço) e os distúrbios retrógrados. Essa complexificação reduz o tempo de identificação da matriz de influência feita no balanceamento eletrônico, e o modelo complexificado obtido através das hipóteses de simetria e isotropia permite desacoplar completamente a compensação das perturbações diretas da compensação das perturbações retrógradas. / This work is inserted in the context of active attenuation of rotor vibrations. These vibrations are caused by the rotor\'s own unbalance and have a frequency equal to the rotor\'s rotation frequency. The unbalance can be modeled as a rotating disturbance force, and a well-known technique for cancelling the effect of such a disturbance is the so-called active balancing, also known as synchronous unbalance compensation or synchronized regulation. The present dissertation brings two contributions to the theme. The first one is the simplification of the synchronous compensator through considerations of rotor symmetry and bearing isotropy, and the second one is to obtain the exact model of the discrete system resulting from the application of the synchronous compensation methodology. These contributions make use of the model described in complex coordinates. The transformation from real coordinates to complex coordinates is defined as a complexification. Thus, the complexification of the model allows the division in half of the dimension of the system variables (states, inputs and outputs), as well as giving a physical sense to the separation between forward disturbances (case of the rotor unbalance) and backward disturbances. This complexification reduces the time of identification of the influence matrix made in active balancing, and the complexified model obtained through symmetry and isotropy hypotheses allows the completely uncouple of the forward disturbances compensation from the backward disturbances compensation.
5

Contribuições para o balanceamento eletrônico de rotores. / Contributions to active unbalance comprensation of rotors.

Perim, Yuri 23 August 2018 (has links)
Este trabalho se insere no contexto de redução de vibrações de rotores via mancais ativos. Essas vibrações são causadas pelo desbalanço do próprio rotor e possuem frequência igual à frequência de rotação desse rotor. O desbalanço pode ser modelado como uma força de perturbação girante, sendo que uma técnica bastante conhecida para anular o efeito dessa perturbação é o balanceamento eletrônico, também chamado de compensação síncrona de desbalanço ou de regulação sincronizada. A presente dissertação traz duas contribuições para o tema. A primeira é a simplificação do compensador síncrono através de considerações de simetria do rotor e de isotropia dos mancais, e a segunda é a obtenção do modelo exato do sistema discreto resultante da aplicação da metodologia de compensação síncrona. Tais contribuições se valem da descrição do modelo em coordenadas complexas. À transformação de coordenadas reais para coordenadas complexas deu-se o nome de complexificação. Assim sendo, a complexificação do modelo permite dividir por dois a dimensão das variáveis do sistema (estados, entradas e saídas), além de dar sentido físico à separação entre os distúrbios diretos (caso do desbalanço) e os distúrbios retrógrados. Essa complexificação reduz o tempo de identificação da matriz de influência feita no balanceamento eletrônico, e o modelo complexificado obtido através das hipóteses de simetria e isotropia permite desacoplar completamente a compensação das perturbações diretas da compensação das perturbações retrógradas. / This work is inserted in the context of active attenuation of rotor vibrations. These vibrations are caused by the rotor\'s own unbalance and have a frequency equal to the rotor\'s rotation frequency. The unbalance can be modeled as a rotating disturbance force, and a well-known technique for cancelling the effect of such a disturbance is the so-called active balancing, also known as synchronous unbalance compensation or synchronized regulation. The present dissertation brings two contributions to the theme. The first one is the simplification of the synchronous compensator through considerations of rotor symmetry and bearing isotropy, and the second one is to obtain the exact model of the discrete system resulting from the application of the synchronous compensation methodology. These contributions make use of the model described in complex coordinates. The transformation from real coordinates to complex coordinates is defined as a complexification. Thus, the complexification of the model allows the division in half of the dimension of the system variables (states, inputs and outputs), as well as giving a physical sense to the separation between forward disturbances (case of the rotor unbalance) and backward disturbances. This complexification reduces the time of identification of the influence matrix made in active balancing, and the complexified model obtained through symmetry and isotropy hypotheses allows the completely uncouple of the forward disturbances compensation from the backward disturbances compensation.
6

Alocação de capacitores em redes de distribuição desequilibradas para minimizar as perdas de energia elétrica e o desequilíbrio /

Semensato, Marcelo. January 2018 (has links)
Orientador: Antonio Padilha Feltrin / Resumo: As redes elétricas de distribuição em sua maioria apresentam cargas elétricas desequilibradas. Por isso é necessário estudar as potências envolvidas em sistemas trifásicos desequilibrados e a compensação das mesmas. O desequilíbrio aumenta as perdas elétricas e diminui o fator de potência da rede elétrica. Esse trabalho propõe a compensação da potência reativa e do desequilíbrio na rede com a finalidade da diminuição das perdas elétricas e a compensação das componentes de sequência desequilibradas da corrente. A utilização da teoria da potência efetiva em sistemas desequilibrados permite calcular as potências reativas e de desequilíbrio, sendo estas as potências compensadas no método proposto. A teoria da potência efetiva mede a eficiência dos métodos testados. Os objetivos da compensação do desequilíbrio são reduzir as perdas elétricas no neutro e o fator de desequilíbrio da tensão, além da potência de desequilíbrio na rede, potência exclusiva do desequilíbrio e que não realiza trabalho. O método proposto para compensação do desequilíbrio e dos reativos na rede de distribuição a quatro fios consiste na alocação de capacitores em delta ou estrela nas barras trifásicas. O método proposto é comparado com dois métodos existentes na literatura. A comparação entre os métodos permite constatar que o método proposto é mais eficiente na redução do desequilíbrio conjuntamente com a compensação das perdas elétricas. Quanto maior é o desequilíbrio da rede elétrica maior é a vantagem da ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Distribution electrical networks mostly have unbalanced electrical loads. Therefore it is necessary to study the powers involved in unbalanced three-phase systems and their compensation. The unbalance increases the power losses and decreases the power factor of the electrical network. This work proposes the compensation of the reactive power and the unbalance in the network with the purpose of reducing the power losses and the compensation of the unbalanced sequence components of the current. The use of the effective power theory in unbalanced systems allows to calculate the reactive and unbalanced power, these being the powers compensated in the proposed method. Effective power theory measures the efficiency of the methods tested. The objectives of the unbalance compensation are to reduce the power losses in the neutral and the unbalance factor of the voltage, besides the unbalanced power in the network, exclusive power of the unbalance and that do not realize work. The proposed method for unbalance and reactive compensation in the four-wire distribution network consists of the allocation of delta or wye-connected capacitors to the three-phase bus. The proposed method is compared with two methods in the literature. The comparison between the methods allows to verify that the proposed method is more efficient in reducing the unbalance together with the compensation of the power losses. The greater the unbalance in power network, the greater the advantage of the compensation b... (Complete abstract click electronic access below) / Doutor