Spelling suggestions: "subject:"unsaturated soils"" "subject:"unsaturated coils""
51 |
A Technique for Estimating the Resilient Modulus (MR) of Unsaturated Soils from Modified California Bearing Ratio (CBR) TestsOmenogor, Kenneth Onyekachi 20 July 2022 (has links)
The Mechanistic-Empirical Pavement Design Guide (MEPDG) which is widely used for the rational design of pavements has three different design levels (i.e., Level 1, Level 2, and Level 3) that are typically based on the resources and the level of risk associated for a given project. Specifically, Level 2 design requires the estimation of the resilient modulus, MR (which is the key parameter in the mechanistic design procedures) from simple experiments such as the California Bearing Ratio (CBR), Unconfined Compressive Strength (UCS) and R-value tests. In this study, a technique is proposed for estimation of MR from CBR that can be used in Level 2 designs of pavements.
The California Bearing Ratio (CBR) is a relatively inexpensive laboratory test which provides a measure of the strength of a soil. The CBR test can easily be performed as the experimental procedure is relatively straightforward to execute. The CBR test procedure widely used and is simple, however the fundamental engineering principles governing CBR tests do not realistically describe the mechanical behavior of pavements. Due to this reason, there has been a significant interest to design pavements using a mechanistic approach such as the resilient modulus (MR). The MR test method provides an indication of the stiffness of pavement materials under cyclic loads, which closely represents the typical loading conditions that are experienced by pavements. MR is a reliable method as it considers the cyclic loading (i.e., resilient response) of pavements. However, it has one major drawback as the triaxial testing equipment used for measurement of the MR is relatively costly, testing is complex and requires trained professional to perform them.
The CBR and MR are both used in present day practice to evaluate the strength of pavement materials. However, the CBR is widely used because of its relatively low cost and the vast experience with its use in the design of pavements. The common trend in today’s practice is to estimate the MR from CBR as evident in most pavement design procedures used around the world. For instance, the Mechanistic-Empirical Pavement Design Guide (AASHTO 2008) suggests that the MR may be estimated from standard tests like the CBR for design of Level 2 pavements. Numerous studies in the literature propose relationships between CBR and MR, but only a hand full of these studies takes account of the effect of matric suction, 𝜓 which is a key stress state variable that describes the rational behavior of unsaturated soils. This thesis document includes the explanation of a modified CBR test equipment capable of measuring unsaturated properties (𝜓 and water content) of specimens subjected to wetting and drying. In addition, some correlations were developed using the measured CBR data and the data of MR from other studies. The results provide useful information for Level 2 mechanistic-empirical design of pavement structures for various soils in the province of Ontario.
|
52 |
Estudo sobre fatores que influenciam a acurácia do método do papel-filtro. / Study on factors which affect the accuracy of the filter-paper method.Gomes, Jorge Eduardo da Silva 22 March 2007 (has links)
O objetivo do presente trabalho é verificar a susceptibilidade do método do papel-filtro a variações em três parâmetros de ensaio: a rugosidade do meio poroso (estrutura da matriz porosa), a extensão do período de exposição do papel-filtro à água intersticial do solo (tempo de equilíbrio) e o grau de deficiência de contacto entre o papel-filtro e a superfície do meio poroso. Para o estudo da rugosidade do meio poroso, três materiais particulados foram empregados. Individualmente, esses materiais apresentam-se mal graduados. A diferença entre eles reside no tamanho médio dos grãos, que para cada um assume um valor característico. A pretexto de uma primeira descrição, seria possível classificá-los como argila (argila caolinítica rosa), areia fina (areia IPT 100, F = 0,15 mm) e areia média (areia IPT 30, F = 0,60 mm). Vale notar que a peculiaridade destas distribuições granulométricas desqualifica esses materiais como elementos representativos para o estudo de solos que ocorrem em problemas reais de engenharia. De fato, para os propósitos do presente trabalho, os solos são instrumentos de investigação, ao passo que o método de aferição de sucção é objeto de estudo. A fim de que o procedimento experimental abrangesse a um só tempo as observações concernentes aos três parâmetros de estudo, concebeu-se um elenco de corpos-de-prova que viabilizou o levantamento concomitante de todas as observações necessárias. Visando a subsidiar as especulações acerca do tempo de equilíbrio, criaram-se grupos de corpos-de-prova (denominados famílias) a serem avaliados periodicamente segundo três intervalos de tempo: sete dias, quatorze dias e vinte e oito dias. A fim de viabilizar a verificação concomitante da influência da rugosidade do meio poroso (ou seja, da estrutura da matriz porosa), previu-se que cada família de corpos-de-prova seria composta por três sub-grupos (designados lotes), representantes dos três materiais empregados na investigação. E, com o intuito de avaliar a influência do grau de deficiência de contacto entre o papel-filtro e o solo, definiu-se cada lote como um conjunto de três corpos-de-prova, cada qual apresentando em uma de suas bases um sulco com diâmetro e profundidade definidos. De corpo-de-prova a corpo-de-prova, para um mesmo lote de uma mesma família, o diâmetro do sulco apresenta variações. Tais variações geram deficits de contacto que valem 20%, 50% e 80% da área do papel-filtro. A profundidade do sulco é a mesma para todos os corpos-de-prova, e é igual à espessura do espaçador empregado nas medições de sucção total (esp = 2mm). Quanto à rugosidade do meio poroso (estrutura da matriz porosa), concluiu-se que o tamanho médio dos grãos, conjugado ao índice de vazios, constiui variável diretamente proporcional aos desvios percentuais de aferição. Ou seja, quanto menor o tamanho médio dos grãos e menor o índice de vazios do material, menores serão os desvios percentuais de aferição de sucção. Quanto à extensão do período de exposição do papel-filtro à água intersticial do solo (tempo de equilíbrio), concluiu-se que o aumento do tempo de interação entre o papel-filtro e o solo pode compensar eventuais dificuldades de acesso da água intersticial ao papel-filtro. Inicialmente, a água atinge o papel-filtro nas regiões onde há contacto efetivo. Então, de maneira progressiva, a água passa a migrar pelo papel-filtro, umedecendo-o uniformemente. Quanto ao grau de deficiência de contacto entre o papel-filtro e a superfície do meio poroso, concluiu-se que a relação desta variável com o desvio percentual de aferição é de proporcionalidade direta. Ou seja, quanto maior a privação de contacto a que for submetido o papel-filtro, tanto mais afastado do valor de sucção matricial plena estará o valor de sucção aferido. Graficamente, isto se observa como um destacamento da curva de retenção levantada para contacto deficiente em relação à curva de retenção levantada para sucção matricial plena. Observou-se também que o destacamento entre as curvas de retenção não ocorreu de maneira uniforme. Para baixos teores de umidade volumétrica, foram maiores os desvios percentuais de aferição. Deste modo, o afastamento entre as curvas deu-se como uma combinação de translação e distorção. / The purpose of this work is to verify the susceptibility of the filter-paper method to variations in three experimental parameters: roughness of porous medium (structure of porous matrix), period of exposition of the filter-paper to pore water (equilibration time) and degree of deficiency in contact between the filter-paper and the porous medium. In order to study roughness of porous medium (structure of porous matrix), three particulate materials have been used. Individually considered, they present a poorly graduated grain size distribution. They differ one from another for their average grain size, which assumes specific values for each material. As a summary description, it would be possible to classify them as kaolin, fine sand (F = 0.15 mm) and coarse sand (F = 0.60 mm). Such peculiar grain size distribution may disqualify these materials as representative of soils which normally occur in engineering problems. In fact, for the purposes of the present work, soil samples are instruments of investigation, while the method of suction measurement is the object of study. A set of samples was designed in order to make feasible simultaneous gauging of all relevant information. Thus, experimental procedure yielded at once data concerning all three parameters. Three groups of samples (each one assembling 9 elements) were created so that remarks could be made on equilibration time. Each of them is called family, being inspected according to a determined periodicity (7 days, 14 days and 28 days). On their turn, families are composed by smaller groups called branches (each branch gathers three samples, all made of the same material). Branches are intended to make possible the evaluation of the effect of average grain size on the accuracy of the filter-paper technique. Finally, in order to evaluate the role of deficient contact between the filter-paper and the soil, samples of a single branch (thus made of the same material) were designed to present a circular perforation on one of their faces. Within each single branch, from sample to sample, perforation diameter increases to generate growing lack of contact between the filter-paper and the soil sample (lack of contact may assume three different values: 20%, 50% or 80% of the filter-paper surface). Perforation depth doesn\'t vary from sample to sample, always being equal to the thickness of the perforated disk used in total suction measurements (which is 2 mm). As for roughness of porous medium (structure of porous matrix), it has been noticed that both average grain size and void ratio are directly proportional to percent measurement deviation. In other words, the smaller the average grain size and the void ratio, the smaller will be percent measurement deviations. As for period of exposition of the filter-paper to pore water (equilibration time), it has been noticed that extending time for interaction between filter-paper and soil may compensate difficulties interstitial water might have to access filter-paper. At first, water reaches the filter-paper on regions where there is effective contact. Then, progressively, water tends to migrate through the filter-paper, wetting it uniformly. As for degree of deficiency in contact between the filter-paper and the porous medium, it has been noticed that such variable is directly proportional to percent measurement deviations. In other words, the greater the lack of contact between the filter-paper and the soil, the further is suction measurement from its full matric suction equivalent. Graphically, it corresponds to a detachment between the retention curve associated with partial matric suction and the retention curve associated with full matric suction. Additionally, it has been noticed that detachment between retention curves hasn\'t occurred uniformly. For lower volumetric water contents, percent measurement deviations were greater. Hence, detachment occurred as a combination of translation and distortion.
|
53 |
Estudo da condutividade hidráulica em solos não saturados / not availableAlfaro Soto, Miguel Angel 26 April 1999 (has links)
A condutividade hidráulica de dois solos não saturados típicos da região de São Carlos, um arenoso e outro argiloso é estudada através de ensaios de campo empregando o permeâmetro Guelph. Duas alternativas de ensaio foram empregadas e os resultados experimentais foram analisados com os modelo teóricos de REYNOLDS e ELRICK (1985) e PHILIP (1985). Paralelamente, obtiveram-se em laboratório curvas de retenção de água dos solos o que possibilitou determinar a função condutividade hidráulica através das fórmulas empíricas de VAN GENUCHTEN, (1980) e de GARDNER (1958). As características e a variação dos valores da condutividade hidráulica não saturada de campo fornecidos pelo permeâmetro Guelph, são discutidos e confrontados com aqueles obtidos a partir dos métodos indiretos provenientes de laboratório. Observou-se que as condutividades hidráulicas saturadas nos solos foram praticamente iguais, quer se considerem os resultados de campo ou laboratório. Os resultados de campo mostraram-se mais consistentes para o solo argiloso qualquer que tenha sido a técnica de ensaio. O parâmetro α da equação de GARDNER (1958) obtido no campo resultou maior que o valor sugerido na literatura ou obtido em laboratório para o solo arenoso. Para o solo argiloso, todas as opções de obtenção do parâmetro tenderam a fornecer valores praticamente iguais. / The unsaturated hydraulic conductivity of two typical soils from the region of São Carlos City, sandy and clayey soils, has been studied through field tests using the Guelph permeameter. Two different alternatives of tests have been performed and the experimental data have been analyzed following the theoretical models from REYNOLDS and ELRICK (1985) and PHILIP (1985). However, soil-water characteristic curves were obtained in such a way that the hydraulic conductivity function could be evaluated using the empirical expressions from VAN GENUCHTEN (1980), and GARDNER (1958). The characteristics and the variation of the field unsaturated hydraulic conductivity values from the Guelph permeameter are discussed and compared to those from laboratory indirect methods. The field results showed to be more consistent to the clayey soil independent on the test or calculation method. The α value (GARDNER, 1958) parameter obtained in the fields was Iarger than the values suggested in the literature or obtained in laboratory for the sandy soil. To the clayey soil, all the obtaining options of the parameter tended to supply values quite the same.
|
54 |
Caracterização geotécnica de solos tropicais não saturados por meio de ensaios de campo / Geotechnical characterization of unsaturated tropical soil by in situ testsRocha, Breno Padovezi 17 August 2018 (has links)
O estudo do comportamento mecânico dos solos é muitas vezes feito por meio de ensaios de campo, cujos resultados permitem a definição do perfil estratigráfico, posição do nível d\'água e estimativa realista dos parâmetros dos materiais envolvidos, bem como a avaliação de sua variabilidade. Os solos tropicais apresentam comportamento peculiar, devido aos processos geológicos e/ou pedológicos inerentes a sua formação e sua condição não saturada. Por isso, a Mecânica dos Solos Clássica apresenta limitações para prever seu comportamento, principalmente quando se leva em conta a variabilidade sazonal. Neste contexto, este trabalho tem como objetivo estudar o comportamento não convencional de perfis de solos tropicais não saturados, com ênfase a influência da variabilidade sazonal na estimativa de parâmetros geotécnicos considerando o efeito da sucção. Os ensaios de campo realizados foram os de Cone (CPT) e de Dilatômetro (DMT), em conjunto com sísmica downhole. Os locais estudados foram os Campos Experimentais da USP de São Carlos e da Unesp de Bauru. Resultados desses ensaios foram reavaliados com o intuito de melhor compreender a variabilidade espaçotemporal. Foi possível verificar que as variações sazonais nos perfis de umidade, e consequentemente da sucção, afetaram os resultados dos ensaios de campo, destacando a importância de considerar a variabilidade sazonal na interpretação dos mesmos. Novas campanhas de ensaios de campo, sempre com a determinação de perfis de umidade e curvas de retenção de água no solo para a estimativa de sucção foram realizadas nesses dois campos experimentais. A interpretação dos resultados desses ensaios considerando o efeito da sucção e microestrutura presentes nos solos tropicais possibilitou avaliar a aplicabilidade das metodologias existentes para a definição do perfil estratigráfico e, em especial, para a estimativa de parâmetros geotécnicos de projeto. Os perfis de qc, KD e ED foram normalizados considerando o efeito da sucção nas tensões efetivas, o que possibilitou uma avaliação mais adequada dos perfis de solo estudados. Concluiu-se que para o entendimento do comportamento mecânico desses solos tropicais é necessário compreender a influência da variabilidade sazonal, bem como identificar a presença de microestrutura nos mesmos. O emprego de técnicas híbridas, como o SCPT e o SDMT, em conjunto com perfis de umidade e curvas de retenção de água no solo permitiram uma melhor caracterização dos perfis investigados. / The study of the mechanical behavior of tropical soils is quite often carried out by in-situ tests. In-situ test data allow defining the stratigraphic profile, position of the ground water level and a realistic estimative of the geomaterials parameters, as well as assessing their variability. Tropical soils present a peculiar behavior due to the geological and/or pedological processes inherent to their formation and to its unsaturated condition. For this reason, the Classical Soil Mechanics has limitations to predict such behavior. In this context, this work aims to study the unusual behavior of unsaturated tropical soils with emphasis on the influence of the time-spatial variability in the estimative of geotechnical parameters caused by soil suction. The in-situ tests were the Cone (CPT) and Dilatometer (DMT) together with downhole seismic tests. The experimental research sites are the Unesp-Bauru and USP-São Carlos. CPT, DMT and downhole seismic tests data were reinterpreted for better understanding the time-spatial variability. It was possible to verify that the seasonal variations in the water content profiles, and consequently on the soil suction, caused changes in the in-situ test data. As a result, the seasonal variability should be considered in the interpretation of the in-situ tests carried out in unsaturated tropical soils. Further in-situ test campaigns, always together with water content profiles determination and soil water retention curves, were carried out in both research sites. The interpretation of the tests data considering the influence of the soil suction and cementation effects in tropical soils allows evaluating the applicability of the classical methodologies for the definition of the stratigraphic profile and the estimative of geotechnical parameters. The qc, KD e ED were normalized considering the soil suction influence on the effective stresses. This procedure allowed a proper site characterization of the studied soil profiles. It was concluded that for the understanding of the mechanical behavior of the studied tropical soils it is necessary to figure out the influence of the seasonal variability, as well as identifying the presence of microstructure on these soils. The use of hybrid techniques, such as SCPT and SDMT, together with moisture content profiles and soil water retention curves allowed a better site characterization of the investigated soil profiles.
|
55 |
Atrito lateral e resistência de base em tubulões a céu aberto em solos colapsíveis / Skin friction and base resistance of large diameter bored piles in collapsible soilsSantos, Túlia Ribeiro da Silva 13 June 2001 (has links)
Este trabalho apresenta resultados de provas de carga em tubulões a céu aberto, com o monitoramento do teor de umidade através do processo de tradagem, a cada metro, até uma profundidade de 9,0 m, em um maciço de solo não-saturado e colapsível, representativo da região centro-oeste do interior do Estado de São Paulo. Ao todo, realizaram-se dez provas de carga, no Campo Experimental de Fundações da EESC/USP, com e sem inundação do terreno, com carregamento do fuste, foram introduzidas placas de isopor (E.P.S) a fim de, durante a realização dos ensaios, obter separadamente as parcelas de resistência de base e por atrito lateral. A partir dos dados obtidos, procedeu-se uma análise da influência da pressão de sucção, da inundação do terreno e do intervalo de tempo entre a escavação e os outros dois, concretados logo após a etapa de escavação. Observou-se que a sucção tem um efeito importante no comportamento dos tubulões a céu aberto: com o aumento da sucção maiores se tornam as resistências de base e por atrito lateral. Consequentemente, a influência do colapso apresenta-se mais significativa com o aumento da pressão de sucção. / This work presents results of static load tests, in large diameter bored piles, with measurements of soil moisture content in an unsatured collapsible soil, considered as representative of the middle - west region of the State of São Paulo, Brazil. Ten load tests were performed at Foundation Experimental Field of the EESC/USP, with and without wetting of the pit and the with quick maintained load (QML). In the large diameter bored piles were introduction, between the base and the shaft, an layer of \"isopor\", to separate the skin friction and the base resistance, during the static load tests. The gathered data allowed an assessment of the influence the soil suction, of the soil soaking and the effect between excavation and concrete in the behaviour these isolate elements of foundation.
|
56 |
Consolidation theories for saturated-unsaturated soils and numerical simulation of residential buildings on expansive soilsZhang, Xiong 01 November 2005 (has links)
The coupled and uncoupled consolidation theories for saturated-unsaturated soils have been discussed. A new method for constructing the constitutive surfaces for saturated-unsaturated soils has been proposed. The consolidation processes for saturated-unsaturated soils have been explained by thermodynamic analogue. One dimensional consolidation theory for saturated-unsaturated soils is presented and a new method is proposed to calculate the immediate settlement, total settlement and the time history of the consolidation settlement manually in the same way as what we have done for saturated soils with a higher accuracy. It makes the consolidation theory of unsaturated soils as applicable as that of saturated soils. This method can also be used to perform uncoupled two or three dimensional consolidation calculation for both expansive soils and collapsible soils. From the analysis, the equivalent effective stress and excessive pore water pressure can be easily calculated. At the same time, the physical meanings for the parameters in the constitutive laws for saturated-unsaturated are illustrated. A new set of the differential equations for the coupled two or three dimensional consolidation of saturated-unsaturated soils are proposed, together with the corresponding method to solve the differential equations. It is also proved numerically and analytically that during the consolidation process the Mandel-Cryer effect exists for unsaturated expansive soils and there is a ??reverse?? Mandel-Cryer effect for unsaturated collapsible soils. A new method is proposed to estimate the volume change of expansive soils.
A complete system is proposed for the numerical simulation of residential buildings on expansive soils. The strength of this method lies in its use of simple and readily available historic weather data such as daily temperature, solar radiation, relative humidity, wind speed and rainfall as input. Accurate three dimensional predictions are obtained by integrating a number of different analytical and numerical techniques: different simulation methods for different boundary conditions such as tree, grass, and bare soils, coupled hydro-mechanical stress analysis to describe deformation of saturated-unsaturated soils, jointed elements simulation of soil-structure interaction, analysis of structure stress moment by general shell elements, and to assess structural damage by the smeared cracking model. The real-time and dynamic simulation results are consistent with filed measurements.
|
57 |
[en] EVALUATION OF HYDRAULIC PROPERTIES OF UNSATURATED TROPICAL SOILS / [pt] AVALIAÇÃO DE PROPRIEDADES HIDRÁULICAS DE SOLOS TROPICAIS NÃO SATURADOSMONICA PRISCILLA HERNANDEZ MONCADA 07 October 2008 (has links)
[pt] O presente trabalho de pesquisa teve dois objetivos
principais. O primeiro foi obter um índice geotécnico que
permita avaliar o grau de intemperismo dos
solos residuais. Para isto foram analisados dados
correspondentes a perfis de alteração de Gnaisse
característicos do município do Rio de Janeiro e executou-se
a caracterização completa de um perfil específico de
alteração de Gnaisse Facoidal. O segundo objetivo foi a
determinação experimental das propriedades
hidráulicas de solos tropicais não saturados. Como parte
deste objetivo foram desenvolvidos novos instrumentos e
modificados equipamentos existentes. A
determinação da curva característica de sucção foi efetuada
em seis solos residuais e em dois solos sedimentares. Na
obtenção das curvas de retenção foram utilizadas as técnicas
de translação de eixos, papel filtro e umidade relativa.
Esta curva foi também definida a partir de resultados de
ensaios de porosimetria de mercúrio. Avaliou-se a
aplicabilidade dos modelos disponíveis na literatura no
ajuste dos dados experimentais. A função de permeabilidade
foi determinada em dois solos, um residual e um sedimentar,
utilizando um permeâmetro de parede
flexível com sucção controlada. Análises numéricas,
efetuadas para avaliar o comportamento do equipamento
utilizado, possibilitaram a definição de uma
metodologia otimizada de interpretação dos resultados. A
aplicabilidade dos modelos disponíveis na literatura na
obtenção da função de permeabilidade foi
analisada, tendo-se verificado a necessidade de introdução
de mudanças nestas formulações para se conseguir reproduzir
as medidas diretas efetuadas. / [en] The present research work had two main objectives. The
first was to obtain a geotechnical index for measuring the
weathering degree of gneissic residual
soils. For that it were analyzed data corresponding to
typical weathering profiles
found in the municipality of Rio de Janeiro and executed a
complete
characterization of a specific weathering profile of
facoidal gneiss. The second
objective was to determine, experimentally, the hydraulic
properties of tropical
unsaturated soils. As part of that new instruments were
developed and existing
equipments were modified. Moisture retention curves were
determined for six
residual soils and two sedimentary ones. The axis-
translation technique, the filter
paper method and the relative humidity one were employed to
obtain such curves.
Data from mercury intrusion porosimetry tests were also
used to define these
curves. The applicability of models available in literature
to adjust the obtained
experimental data was evaluated. The hydraulic conductivity
function was
determined for two soils, one residual and one sedimentary.
A suction controlled,
flexible wall permeameter set up was used for that.
Numerical modeling was
implemented to evaluate the performance of the experimental
set up. This
provided means for an optimized interpretation of the
testing results. The
applicability of models available in the literature to
obtain the permeability
functions was evaluated, being found the need to introduce
changes in their
formulation in order to be able to reproduce the obtained
experimental data.
|
58 |
Atrito lateral e resistência de base em tubulões a céu aberto em solos colapsíveis / Skin friction and base resistance of large diameter bored piles in collapsible soilsTúlia Ribeiro da Silva Santos 13 June 2001 (has links)
Este trabalho apresenta resultados de provas de carga em tubulões a céu aberto, com o monitoramento do teor de umidade através do processo de tradagem, a cada metro, até uma profundidade de 9,0 m, em um maciço de solo não-saturado e colapsível, representativo da região centro-oeste do interior do Estado de São Paulo. Ao todo, realizaram-se dez provas de carga, no Campo Experimental de Fundações da EESC/USP, com e sem inundação do terreno, com carregamento do fuste, foram introduzidas placas de isopor (E.P.S) a fim de, durante a realização dos ensaios, obter separadamente as parcelas de resistência de base e por atrito lateral. A partir dos dados obtidos, procedeu-se uma análise da influência da pressão de sucção, da inundação do terreno e do intervalo de tempo entre a escavação e os outros dois, concretados logo após a etapa de escavação. Observou-se que a sucção tem um efeito importante no comportamento dos tubulões a céu aberto: com o aumento da sucção maiores se tornam as resistências de base e por atrito lateral. Consequentemente, a influência do colapso apresenta-se mais significativa com o aumento da pressão de sucção. / This work presents results of static load tests, in large diameter bored piles, with measurements of soil moisture content in an unsatured collapsible soil, considered as representative of the middle - west region of the State of São Paulo, Brazil. Ten load tests were performed at Foundation Experimental Field of the EESC/USP, with and without wetting of the pit and the with quick maintained load (QML). In the large diameter bored piles were introduction, between the base and the shaft, an layer of \"isopor\", to separate the skin friction and the base resistance, during the static load tests. The gathered data allowed an assessment of the influence the soil suction, of the soil soaking and the effect between excavation and concrete in the behaviour these isolate elements of foundation.
|
59 |
Estudo da influência da infiltração de águas pluviais na estabilidade de um talude de solo residual / Study of the influence of infiltration of rainwater in slope stability residual soilTeixeira, Emmanuel Kennedy da Costa 27 February 2014 (has links)
Made available in DSpace on 2015-03-26T13:28:31Z (GMT). No. of bitstreams: 1
texto completo.pdf: 2857097 bytes, checksum: 6b461d27fbface3dd178a5bbe1ed092c (MD5)
Previous issue date: 2014-02-27 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Slopes of soil and/or rock exist naturally or are manmade in excavations (cut slopes) or landfills. When precipitation occurs on the slope, part of the rainwater infiltrates and, as the ground layers are being saturated, the suction forces decrease, eventually leading to the slope failure. This paper discusses the effect of infiltration of rainwater on the variation of safety factor values of a slope made of gneiss residual soil located at the Federal University of Viçosa (UFV) campus, next to another slope that failed in December, 2011. Results of laboratory tests - characterization, direct shear, water retention curve, and saturated permeability - in disturbed and undisturbed soil samples of the different soils existing in the slope and identified by standard penetration tests (SPT), are presented. Following, The variation of water content and suction in the slope are calculated, together with the safety factor along the year 2011, considering the climatic data measured at the UFV weather station - precipitation, temperature, speed and direction of winds. The infiltration of water in the slope was calculated using the commercial program VADOSE / W and the daily stability analyzes by the program SLOPE/W both from GeoStudio. The analyses showed that during rainy periods the value of the safety factor decreases, the lowest value being 1,545, in December. In dry periods, the safety factor tends to increase, but with lower rates compared to the decrease occurred during rainy periods. By analyzing the suction and the safety factor together throughout the year, it was observed that the behavior of the two variables is similar, ie, as described in the literature, when suction decreases, resistance also decreases, and the safety factor diminished. / Taludes de solo e/ou rocha existem naturalmente, ou são construídos pelo homem em escavações (taludes de corte) ou aterro. Em países tropicais, como o Brasil, muitos taludes encontram-se em parte ou totalmente com os solos na zona vadosa. Nestes casos, ocorrem forças de sucção que aumentam a resistência dos materiais que compõem o talude. Quando acontece uma precipitação sobre o talude, parte das águas pluviais infiltra e, à medida que as camadas de solo vão sendo saturadas, as forças de sucção diminuem o que, eventualmente, pode ocasionar a ruptura do talude. Neste trabalho discute-se o efeito da infiltração das águas pluviais na variação dos fatores de segurança de um talude de solo residual de gnaisse localizado no campus da Universidade Federal de Viçosa (UFV), ao lado de outro talude onde houve um significativo escorregamento em dezembro de 2011. São apresentados resultados de ensaios de laboratório caracterização, cisalhamento direto, curva de retenção de água e permeabilidade saturada em amostras deformadas e indeformadas dos solos identificados no talude por meio de sondagem à percussão. Em seguida, descreve-se a variação da umidade volumétrica, da sucção e do fator de segurança do talude ao longo do ano de 2011, considerando os dados climáticos medidos na estação meteorológica da UFV precipitação, temperatura, velocidade e direção dos ventos. O balanço hídrico e a infiltração de água no talude foram feitos com o auxílio do programa VADOSE/W e a análise diária de estabilidade feita com o programa SLOPE/W da GeoStudio. As análises mostraram que em períodos chuvosos o valor do fator de segurança diminui, tendo obtido o menor valor de 1,545, em dezembro, o que justifica numericamente a estabilidade observada em campo. Em períodos secos o valor tende a aumentar, porém em taxas menores quando comparados com a diminuição ocorrida em períodos chuvosos. Ao analisar a sucção e o fator de segurança conjuntamente ao longo do ano, observou-se que comportamento similar para as duas variáveis, ou seja, assim como descrito na literatura, quando a sucção diminuiu a resistência do talude também diminui, o que diminuiu o valor do fator de segurança.
|
60 |
Análise do desempenho de um solo compactado utilizado na camada de cobertura de um aterro sanitário.ARAUJO, Pabllo da Silva. 12 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-12T20:13:37Z
No. of bitstreams: 1
PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5) / Made available in DSpace on 2018-04-12T20:13:37Z (GMT). No. of bitstreams: 1
PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5)
Previous issue date: 2017-03-29 / Capes / Uma das formas de tratamento de Resíduos Sólidos Urbanos (RSU) que mais se destaca são os aterros sanitários, que possui como vantagens, a facilidade de operação, menor custo quando comparado às outras técnicas (triagem, tratamento biológico, incineração, entre outras) e a existência de um plano de monitoramento contínuo. O aterro sanitário utiliza uma camada de cobertura final de solo compactado com a finalidade de isolar os resíduos do meio externo, minimizar a entrada de água para o interior do maciço sanitário, reduzir as emissões de gases para a atmosfera, evitar a proliferação de roedores e vetores de doença, entre outras. As Normas Brasileiras não regulamentam o tipo de solo a ser utilizado, nem técnicas de execução de camadas de coberturas de aterros, nem a forma de monitoramento, possuindo como única exigência o atendimento de um coeficiente mínimo de permeabilidade à água. Diante disso, este trabalho tem como objetivo analisar o desempenho do solo compactado utilizado na camada de cobertura final de um aterro de resíduos sólidos, tendo como campo experimental o Aterro Sanitário de Campina Grande/PB. Para isso foi realizada a caracterização física do solo utilizado na camada, verificação de seus parâmetros quanto à viabilidade para uso em aterros sanitários, análise físico-química e mineralógica, obtenção da curva de retenção de água no solo e análise dos pontos experimentais da curva aos ajustes propostos na literatura. Foi verificado o comportamento do solo frente aos processos de umedecimento/secagem e expansão/contração, observação da relação entre a umidade ótima de compactação e o ponto de entrada generalizada de ar (GAE), além da verificação da variação da umidade do solo em um perfil experimental da camada de cobertura por meio de sensores capacitivos. Os resultados demonstraram que, o solo possui permeabilidade à água
admissível para uso em aterros sanitários segundo as normas nacionais e internacionais. O ajuste da curva de Van Genuchten aos pontos experimentais da curva de retenção atendeu às condições de concordância a partir dos parâmetros estatísticos analisados. A umidade ótima de compactação do solo possui valor próximo ao GAE, onde se inicia a dessaturação do solo, no qual o ar começa a entrar nos maiores poros formados pela drenagem da água e perda de umidade. Deve-se realizar a compactação do solo na energia proctor normal obedecendo à adição de água suficiente para atingir a umidade ótima, em um intervalo aceitável de ± 2%. Pode-se concluir que, o tipo de camada de cobertura final (solo argiloso compactado) utilizado é inadequado para a região do aterro devido às características climatológicas a que o solo está submetido e a ausência de proteção vegetal superficial. A aplicação da energia proctor normal para compactação do solo da camada de cobertura do aterro sanitário proporciona condições favoráveis à redução da permeabilidade à água do solo. A curva de retenção de água no solo da camada de cobertura do aterro sanitário apresenta comportamento unimodal e possui características de um solo argiloso. A utilização de sensores capacitivos se mostrou como uma técnica eficaz para aquisição automática da umidade do solo e verificação da sua variação ao longo do tempo, bem como, o monitoramento da sucção pela espessura da
camada de cobertura final de solo compactado. / One of the forms of treatment of Municipal Solid Waste (MSW) is the landfill, which has the
advantages of ease of operation, lower cost when compared to other techniques (sorting,
biological treatment, incineration, among others) and the existence of a continuous monitoring plan. The landfill uses a final cover layer of compacted soil to isolate residues from the external environment, minimize the entry of water into the landfill, reduce the emission of gases into the atmosphere, prevent the proliferation of rodent and vectors of disease, among others. The Brazilian Regulations do not regulate the type of soil to be used, nor techniques for implementing layers of landfills, nor the form of monitoring, having as sole requirement the attendance of a minimum coefficient of water permeability. The objective of this work is to analyze the performance of the compacted soil used in the final cover layer of a landfill, with the Landfill Campina Grande/PB as an experimental field. The physical characterization of the soil used in the layer, verification of its parameters regarding the feasibility for use in landfills, physical-chemical and mineralogical analysis, obtaining the water retention curve in the soil and analysis of the experimental points of the curve were performed adjustments proposed in the literature. The behavior of the soil was verified in relation to the wetting/drying and swell/contraction processes, observation of the relation between the optimum compaction humidity and the Generalized Air Entry (GAE), besides the verification of soil moisture variation in one experimental profile of the cover layer by means of capacitive sensors. The results showed that the soil has permeability to water admissible for use in landfills according to national and international standards. The adjustment of the Van Genuchten curve to the experimental points of the retention curve met the conditions of agreement from the statistical parameters analyzed. The optimum soil compaction humidity has a value close to GAE, where soil desaturation begins, in which the air begins to enter the larger pores formed by water drainage and moisture loss. Soil compaction must be carried out in normal proctor energy by adding sufficient water to achieve optimum moisture, within an acceptable range of ± 2%. It can be concluded that the type of final cover layer (compacted clay soil) used is unsuitable for the landfill region due to the climatological characteristics to which the soil is subjected and the absence of surface vegetation protection. The application of normal proctor energy to soil compaction of the landfill cover layer provides favorable conditions for the reduction of soil water permeability. The water retention curve in the soil of the final cover layer of the landfill presents unimodal behavior and has characteristics of a clay soil. The use of capacitive sensors proved to be an effective technique for automatic acquisition of soil moisture and verification of its variation over time, as well as the monitoring of suction by the thickness of the final cover layer of compacted soil.
|
Page generated in 0.0681 seconds