• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 6
  • 3
  • 3
  • 1
  • 1
  • Tagged with
  • 37
  • 37
  • 16
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

用陰極射線示波器描繪真空管特性曲線的電路設計

LIN, Yikun 01 January 1950 (has links)
No description available.
22

Electron beam waves in microwave tubes

January 1958 (has links)
H.A. Haus. / "April 5, 1958"--Cover. "Presented at the Symposium on Electronic Waveguides, Polytechnic Institute of Brooklyn, April 8-10, 1958." / Bibliography: p. 131-132. / Army Signal Corps Contract DA36-039-sc-64637. Dept. of the Army Task 3-99-06-108 and Project 3-99-00-100.
23

Power gain in feedback amplifiers

January 1953 (has links)
S.J. Mason. / "August 25, 1953." / Army Signal Corps Contract DA 36-039 sc-100 Project 8-102B-0 Dept. of the Army Project 3-99-10-022
24

Low-frequency spectrum of lock-in amplifiers

January 1949 (has links)
C.A. Stutt. / "March 26, 1949." / Bibliography: p. 18. / Army Signal Corps Contract No. W36-039-sc-32037 Project No. 102B Dept. of the Army Project No. 3-99-10-022
25

Some designs and applications for packaged amplifiers using subminiature tubes

January 1947 (has links)
B. Chance, J.N. Thurston, P.L. Richman. / "Reprinted from the Review of scientific instruments, v. 18, no. 9, 610-616, Sept., 1947." / Includes bibliographical references.
26

Využití elektronek v současné době / The use of vacuum tubes at present time

ČEPIČKA, Josef January 2014 (has links)
Aim of this thesis is to construct a demonstration model of a vacuum tube amplifier with a possibility of measurement of signal on more places and a possibility to see the wiring and construction of the amplifier. The first part of the work treats some important themes concerning vacuum tubes and wiring with them, for example a principle of signal intensification by vacuum tubes, categories of low-frequency amplifiers and description of several types of undesirable distortions. Next part deals with the design of the constructed amplifier, the description of the construction itself and placement of the components on the printed circuit boards and used vacuum tubes and transformers. The following part is focused on measurement of the basic properties of the amplifier and vacuum tubes by means of TESLA BM215A appliance. The final part contains technical parameters of the amplifier and photo documentation.
27

Phase Locked Loop and Modulo Games, The Dogma Loops; and “Finding Ibrida”

Stewart, Kenneth David January 2016 (has links)
<p>This dissertation consists of two independent musical compositions and an article detailing the process of the design and assembly of an electric guitar with particular emphasis on the carefully curated suite of embedded effects. </p><p>The first piece, 'Phase Locked Loop and Modulo Games' is scored for electric guitar and a single echo of equal volume less than a beat away. One could think of the piece as a 15 minute canon at the unison at the dotted eighth note (or at times the quarter or triplet-quarter), however the compositional motivation is more about weaving a composite texture between the guitar and its echo that is, while in theory extremely contrapuntal, in actuality is simply a single [superhuman] melodic line.</p><p>The second piece, 'The Dogma Loops' picks up a few compositional threads left by ‘Phase Locked Loop’ and weaves them into an entirely new tapestry. 'Phase Locked Loop' is motivated by the creation of a complex musical composite that is for the most part electronically transparent. 'The Dogma Loops' questions that same notion of composite electronic complexity by essentially asking a question: "what are the inputs to an interactive electronic system that create the most complex outputs via the simplest musical means possible?"</p><p>'The Dogma Loops' is scored for Electric Guitar (doubling on Ukulele), Violin and Violoncello. All of the principal instruments require an electronic pickup (except the Uke). The work is in three sections played attacca; [Automation Games], [Point of Origin] and [Cloning Vectors]. </p><p>The third and final component of the document is the article 'Finding Ibrida.' This article details the process of the design and assembly of an electric guitar with integrated effects, while also providing the deeper context (conceptual and technical) which motivated the efforts and informed the challenges to hybridize the various technologies (tubes, transistors, digital effects and a microcontroller subsystem). The project was motivated by a desire for rigorous technical and hands-on engagement with analog signal processing as applied to the electric guitar. ‘Finding Ibrida’ explores sound, some myths and lore of guitar tech and the history of electric guitar distortion and its culture of sonic exploration.</p> / Dissertation
28

Análise comparativa de um sistema passivo com um sistema ativo de aquecimento de água por meio de um coletor solar de tubos de vidro a vácuo

Naranjo Toro, Juan Diego January 2015 (has links)
Os sistemas solares de aquecimento de água são uma forma de produção de energia não poluente, que já faz parte da matriz energética brasileira. O uso deste tipo de sistemas traz benefícios econômicos ao país e principalmente a quem os utiliza, devido à poupança no uso de outras fontes de energia para o aquecimento da água. No Brasil o aquecimento solar de água é realizado, principalmente, por coletores solares planos, tecnologia bem conhecida e fabricada no país a preços baixos. Mas atualmente há uma outra tecnologia que está sendo difundida no âmbito nacional, os coletores solares de tubos a vácuo, os quais estão sendo produzidos internacionalmente em uma escala maior, importados e comercializados a preços mais competitivos no mercado nacional. Por isto é necessário entender estes sistemas e o seu funcionamento para evitar erros na sua instalação e otimizar sua operação. Nesta dissertação é realizada uma análise comparativa de um sistema de aquecimento de água composto por um coletor solar de tubos de vidro a vácuo de extração de calor por transferência direta operando em circulação forçada com o mesmo sistema operando em circulação por termossifão. Esta comparação foi realizada determinando a energia anual que o sistema pode produzir para cada tipo de circulação, a qual foi calculada usando como referência a norma ISO 9459-2 e os dados climáticos da cidade de Porto Alegre do Estado do Rio Grande do Sul. Também foram realizadas medições da vazão em termossifão, entre o reservatório e o coletor solar, e foi determinado o coeficiente de perdas térmicas do tanque reservatório segundo os procedimentos da mesma norma. Para isto foi realizada a montagem de uma bancada experimental, com sensores e instrumentos de medida que foram calibrados. Para o sistema de aquecimento testado, os resultados mostram que o sistema trabalhando em circulação por termossifão produz maior quantidade de energia no ano do que o sistema em circulação forçada, onde se observou que a estratificação no tanque reservatório era menor. Também foi observado que a máxima vazão em termossifão para este sistema de aquecimento de água foi de 0,5 L/min. / Solar water heating systems are a method of clean energy production, which is already part of the Brazilian energy matrix. The use of these systems brings economic benefits to the country and especially who use them due to savings in the use of other sources of energy for heating water. In Brazil, the solar water heating is carried out mainly by flat solar collectors, which is a widely known technology because it is produced in the country at low prices. But recently, there is another technology that is being used named: evacuated solar collectors. These collectors are being worldwide produced on a large scale and they are imported and inserted at competitive prices in the domestic market. Therefore it is necessary to understand these systems and their operation to avoid errors in its installation and optimize their operation. In this work, it is accomplishing a comparative analysis of a solar water heating system composed by a water-in-glass evacuated tube solar collector working in forced circulation with the same system working in thermosyphon circulation. This comparison was performed by determining the annual energy that the system can produce for each type of circulation, which was calculated based on the ISO 9459-2 standard and the climatic data of the Porto Alegre city, state of the Rio Grande Do Sul. Also, it was performed thermosyphon measurements between the thermal reservoir and the solar collector, and it was calculated the heat loss coefficient from the reservoir tank according to the procedures of ISO 9459-2 standard. To do so, a testing bench was made, with sensors and measuring instruments which were calibrated before use. For the heating system tested, the results show that the system with thermosyphon circulation produces more annual energy than the forced circulation system where the water temperature stratification in the thermal reservoir was lower. Also, it was observed that the maximum thermosyphon flow for this solar water heating system was 0,5 L/min.
29

Análise comparativa de um sistema passivo com um sistema ativo de aquecimento de água por meio de um coletor solar de tubos de vidro a vácuo

Naranjo Toro, Juan Diego January 2015 (has links)
Os sistemas solares de aquecimento de água são uma forma de produção de energia não poluente, que já faz parte da matriz energética brasileira. O uso deste tipo de sistemas traz benefícios econômicos ao país e principalmente a quem os utiliza, devido à poupança no uso de outras fontes de energia para o aquecimento da água. No Brasil o aquecimento solar de água é realizado, principalmente, por coletores solares planos, tecnologia bem conhecida e fabricada no país a preços baixos. Mas atualmente há uma outra tecnologia que está sendo difundida no âmbito nacional, os coletores solares de tubos a vácuo, os quais estão sendo produzidos internacionalmente em uma escala maior, importados e comercializados a preços mais competitivos no mercado nacional. Por isto é necessário entender estes sistemas e o seu funcionamento para evitar erros na sua instalação e otimizar sua operação. Nesta dissertação é realizada uma análise comparativa de um sistema de aquecimento de água composto por um coletor solar de tubos de vidro a vácuo de extração de calor por transferência direta operando em circulação forçada com o mesmo sistema operando em circulação por termossifão. Esta comparação foi realizada determinando a energia anual que o sistema pode produzir para cada tipo de circulação, a qual foi calculada usando como referência a norma ISO 9459-2 e os dados climáticos da cidade de Porto Alegre do Estado do Rio Grande do Sul. Também foram realizadas medições da vazão em termossifão, entre o reservatório e o coletor solar, e foi determinado o coeficiente de perdas térmicas do tanque reservatório segundo os procedimentos da mesma norma. Para isto foi realizada a montagem de uma bancada experimental, com sensores e instrumentos de medida que foram calibrados. Para o sistema de aquecimento testado, os resultados mostram que o sistema trabalhando em circulação por termossifão produz maior quantidade de energia no ano do que o sistema em circulação forçada, onde se observou que a estratificação no tanque reservatório era menor. Também foi observado que a máxima vazão em termossifão para este sistema de aquecimento de água foi de 0,5 L/min. / Solar water heating systems are a method of clean energy production, which is already part of the Brazilian energy matrix. The use of these systems brings economic benefits to the country and especially who use them due to savings in the use of other sources of energy for heating water. In Brazil, the solar water heating is carried out mainly by flat solar collectors, which is a widely known technology because it is produced in the country at low prices. But recently, there is another technology that is being used named: evacuated solar collectors. These collectors are being worldwide produced on a large scale and they are imported and inserted at competitive prices in the domestic market. Therefore it is necessary to understand these systems and their operation to avoid errors in its installation and optimize their operation. In this work, it is accomplishing a comparative analysis of a solar water heating system composed by a water-in-glass evacuated tube solar collector working in forced circulation with the same system working in thermosyphon circulation. This comparison was performed by determining the annual energy that the system can produce for each type of circulation, which was calculated based on the ISO 9459-2 standard and the climatic data of the Porto Alegre city, state of the Rio Grande Do Sul. Also, it was performed thermosyphon measurements between the thermal reservoir and the solar collector, and it was calculated the heat loss coefficient from the reservoir tank according to the procedures of ISO 9459-2 standard. To do so, a testing bench was made, with sensors and measuring instruments which were calibrated before use. For the heating system tested, the results show that the system with thermosyphon circulation produces more annual energy than the forced circulation system where the water temperature stratification in the thermal reservoir was lower. Also, it was observed that the maximum thermosyphon flow for this solar water heating system was 0,5 L/min.
30

Análise comparativa de um sistema passivo com um sistema ativo de aquecimento de água por meio de um coletor solar de tubos de vidro a vácuo

Naranjo Toro, Juan Diego January 2015 (has links)
Os sistemas solares de aquecimento de água são uma forma de produção de energia não poluente, que já faz parte da matriz energética brasileira. O uso deste tipo de sistemas traz benefícios econômicos ao país e principalmente a quem os utiliza, devido à poupança no uso de outras fontes de energia para o aquecimento da água. No Brasil o aquecimento solar de água é realizado, principalmente, por coletores solares planos, tecnologia bem conhecida e fabricada no país a preços baixos. Mas atualmente há uma outra tecnologia que está sendo difundida no âmbito nacional, os coletores solares de tubos a vácuo, os quais estão sendo produzidos internacionalmente em uma escala maior, importados e comercializados a preços mais competitivos no mercado nacional. Por isto é necessário entender estes sistemas e o seu funcionamento para evitar erros na sua instalação e otimizar sua operação. Nesta dissertação é realizada uma análise comparativa de um sistema de aquecimento de água composto por um coletor solar de tubos de vidro a vácuo de extração de calor por transferência direta operando em circulação forçada com o mesmo sistema operando em circulação por termossifão. Esta comparação foi realizada determinando a energia anual que o sistema pode produzir para cada tipo de circulação, a qual foi calculada usando como referência a norma ISO 9459-2 e os dados climáticos da cidade de Porto Alegre do Estado do Rio Grande do Sul. Também foram realizadas medições da vazão em termossifão, entre o reservatório e o coletor solar, e foi determinado o coeficiente de perdas térmicas do tanque reservatório segundo os procedimentos da mesma norma. Para isto foi realizada a montagem de uma bancada experimental, com sensores e instrumentos de medida que foram calibrados. Para o sistema de aquecimento testado, os resultados mostram que o sistema trabalhando em circulação por termossifão produz maior quantidade de energia no ano do que o sistema em circulação forçada, onde se observou que a estratificação no tanque reservatório era menor. Também foi observado que a máxima vazão em termossifão para este sistema de aquecimento de água foi de 0,5 L/min. / Solar water heating systems are a method of clean energy production, which is already part of the Brazilian energy matrix. The use of these systems brings economic benefits to the country and especially who use them due to savings in the use of other sources of energy for heating water. In Brazil, the solar water heating is carried out mainly by flat solar collectors, which is a widely known technology because it is produced in the country at low prices. But recently, there is another technology that is being used named: evacuated solar collectors. These collectors are being worldwide produced on a large scale and they are imported and inserted at competitive prices in the domestic market. Therefore it is necessary to understand these systems and their operation to avoid errors in its installation and optimize their operation. In this work, it is accomplishing a comparative analysis of a solar water heating system composed by a water-in-glass evacuated tube solar collector working in forced circulation with the same system working in thermosyphon circulation. This comparison was performed by determining the annual energy that the system can produce for each type of circulation, which was calculated based on the ISO 9459-2 standard and the climatic data of the Porto Alegre city, state of the Rio Grande Do Sul. Also, it was performed thermosyphon measurements between the thermal reservoir and the solar collector, and it was calculated the heat loss coefficient from the reservoir tank according to the procedures of ISO 9459-2 standard. To do so, a testing bench was made, with sensors and measuring instruments which were calibrated before use. For the heating system tested, the results show that the system with thermosyphon circulation produces more annual energy than the forced circulation system where the water temperature stratification in the thermal reservoir was lower. Also, it was observed that the maximum thermosyphon flow for this solar water heating system was 0,5 L/min.

Page generated in 0.0254 seconds