• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Late arrhythmic disorders after transcatheter aortic valve implantation

Muntane Carol, Guillem 15 September 2022 (has links)
L'avènement du remplacement de la valve aortique par cathéter (TAVI) a entraîné un changement de pratique dans le traitement de la sténose aortique. Le TAVI est devenu le traitement de choix pour les patients à risque chirurgical moyen à élevé et son expansion vers le traitement des patients à faible risque est déjà à l'étude. Au cours des dernières années, les améliorations successives apportées aux systèmes de valvules cardiaques par cathéter ont permis de réduire progressivement le nombre de complications péri-procédurales et de décès. Cependant, certains problèmes restent à résoudre. Les troubles de la conduction tels que le bloc de branche gauche nouvellement apparu ou le bloc auriculo-ventriculaire de haut degré nécessitant une implantation permanente de stimulateur cardiaque n'ont pas diminué avec le temps et restent la complication la plus fréquente de la procédure. Alors que les études précédentes se sont concentrées sur l'apparition des troubles de la conduction dans la période péri procédurale, il existe peu de données sur les épisodes tardifs (après la sortie de l'hôpital). D'autre part, la prévalence et l'impact clinique des tachyarythmies chez les patients après un TAVI ont été moins étudiés, en particulier après la sortie de l'hôpital. Différents inconvénients restent non résolus dans ce contexte (par exemple, l'évolution à long terme de l'ECG chez des patients sans troubles de la conduction, la prise en charge des patients avec nouveau bloc de branche gauche, les prédicteurs de la régression des anomalies à l'ECG chez des patients avec bloc de branche gauche). En outre, la surveillance électrocardiographique continue est apparue comme un outil utile pour diagnostiquer les troubles arythmiques (brady- et tachyarythmies) après le départ de l'hôpital, mais les données disponibles dans le cadre du TAVI sont rares. Leur sécurité et leur utilité clinique restent donc à élucider. Les principaux objectifs de ce projet de recherche doctoral sont les suivants: (i) évaluer l'incidence et l'impact clinique des troubles arythmiques tardifs (après le départ de l'hôpital) chez les patients avec TAVI, et (ii) démontrer la sécurité et l'utilité de la surveillance continue non invasive de l'ECG après une procédure TAVI. / The advent of transcatheter aortic valve implantation (TAVI) has meant a paradigm shift in the treatment of aortic stenosis. TAVI has become the preferred treatment for patients at intermediate to high surgical risk and its expansion towards the treatment of low-risk patients is under study. During the last years, the successive improvements in transcatheter heart valve systems have led to a progressive reduction of periprocedural complications and death. However, some issues remain to be resolved. Conduction disturbances (CDs) such as new-onset left bundle branch block (LBBB) or high-degree atrioventricular block requiring permanent pacemaker (PPM) implantation have not decreased over time and remains the most frequent complication of the procedure. Whereas previous studies focused on the occurrence of CDs in the periprocedural period, scarce data exist on late (after discharge) episodes. On the other hand, the prevalence and clinical impact of new-onset tachyarrhythmias in patients following TAVI have been less studied, especially after the hospital discharge. Different drawbacks remain unsolved in this context (e.g. long-term ECG evolution in patients without ECG-CDs, management of new-onset LBBB, predictors of ECG regression in new-onset LBBB patients). Furthermore, continuous electrocardiographic monitoring has emerged as a useful tool to unravel arrhythmic disorders (either brady and tachyarrhythmias) in the early phase post-discharge, but data in the TAVI setting is scarce. Thus, their safety and clinical usefulness remain to be elucidated. The main objectives of this PhD research project are: (i) to assess the incidence and clinical impact of late arrhythmic disorders (post discharge) in TAVI recipients (ii) to demonstrate the safety and usefulness of non-invasive continuous ECG monitoring post-TAVI.
2

Late arrhythmic disorders after transcatheter aortic valve implantation

Muntane Carol, Guillem 15 September 2022 (has links)
L'avènement du remplacement de la valve aortique par cathéter (TAVI) a entraîné un changement de pratique dans le traitement de la sténose aortique. Le TAVI est devenu le traitement de choix pour les patients à risque chirurgical moyen à élevé et son expansion vers le traitement des patients à faible risque est déjà à l'étude. Au cours des dernières années, les améliorations successives apportées aux systèmes de valvules cardiaques par cathéter ont permis de réduire progressivement le nombre de complications péri-procédurales et de décès. Cependant, certains problèmes restent à résoudre. Les troubles de la conduction tels que le bloc de branche gauche nouvellement apparu ou le bloc auriculo-ventriculaire de haut degré nécessitant une implantation permanente de stimulateur cardiaque n'ont pas diminué avec le temps et restent la complication la plus fréquente de la procédure. Alors que les études précédentes se sont concentrées sur l'apparition des troubles de la conduction dans la période péri procédurale, il existe peu de données sur les épisodes tardifs (après la sortie de l'hôpital). D'autre part, la prévalence et l'impact clinique des tachyarythmies chez les patients après un TAVI ont été moins étudiés, en particulier après la sortie de l'hôpital. Différents inconvénients restent non résolus dans ce contexte (par exemple, l'évolution à long terme de l'ECG chez des patients sans troubles de la conduction, la prise en charge des patients avec nouveau bloc de branche gauche, les prédicteurs de la régression des anomalies à l'ECG chez des patients avec bloc de branche gauche). En outre, la surveillance électrocardiographique continue est apparue comme un outil utile pour diagnostiquer les troubles arythmiques (brady- et tachyarythmies) après le départ de l'hôpital, mais les données disponibles dans le cadre du TAVI sont rares. Leur sécurité et leur utilité clinique restent donc à élucider. Les principaux objectifs de ce projet de recherche doctoral sont les suivants: (i) évaluer l'incidence et l'impact clinique des troubles arythmiques tardifs (après le départ de l'hôpital) chez les patients avec TAVI, et (ii) démontrer la sécurité et l'utilité de la surveillance continue non invasive de l'ECG après une procédure TAVI. / The advent of transcatheter aortic valve implantation (TAVI) has meant a paradigm shift in the treatment of aortic stenosis. TAVI has become the preferred treatment for patients at intermediate to high surgical risk and its expansion towards the treatment of low-risk patients is under study. During the last years, the successive improvements in transcatheter heart valve systems have led to a progressive reduction of periprocedural complications and death. However, some issues remain to be resolved. Conduction disturbances (CDs) such as new-onset left bundle branch block (LBBB) or high-degree atrioventricular block requiring permanent pacemaker (PPM) implantation have not decreased over time and remains the most frequent complication of the procedure. Whereas previous studies focused on the occurrence of CDs in the periprocedural period, scarce data exist on late (after discharge) episodes. On the other hand, the prevalence and clinical impact of new-onset tachyarrhythmias in patients following TAVI have been less studied, especially after the hospital discharge. Different drawbacks remain unsolved in this context (e.g. long-term ECG evolution in patients without ECG-CDs, management of new-onset LBBB, predictors of ECG regression in new-onset LBBB patients). Furthermore, continuous electrocardiographic monitoring has emerged as a useful tool to unravel arrhythmic disorders (either brady and tachyarrhythmias) in the early phase post-discharge, but data in the TAVI setting is scarce. Thus, their safety and clinical usefulness remain to be elucidated. The main objectives of this PhD research project are: (i) to assess the incidence and clinical impact of late arrhythmic disorders (post discharge) in TAVI recipients (ii) to demonstrate the safety and usefulness of non-invasive continuous ECG monitoring post-TAVI.
3

Ingénierie tissulaire de valves cardiaques : apport des techniques de thérapie cellulaire

Juthier, Francis 29 September 2009 (has links) (PDF)
Les prothèses valvulaires cardiaques actuellement commercialisées présentent des inconvénients importants. Les prothèses biologiques (xéno ou allo greffes) sont soumises à une dégénérescence progressive, et les prothèses mécaniques nécessitent un traitement anticoagulant à vie. Des perspectives nouvelles sont apparues avec l'ingénierie tissulaire, dont le but est de créer à partir d'un support non cellularisé (matrice biodégradable de polymère de glycogène, ou xénogreffe décellularisée) un substitut valvulaire « vivant » offrant une meilleur longévité et des performances hémodynamiques optimales, ainsi que des capacités de remodelage et de croissance. Nous avons élaboré un modèle de xénogreffe porcine décellularise implanté en position systémique puis pulmonaire chez un agneau et testé plusieurs modes de recolonisation de cette matrice, par différents types de cellules. La spécificité de notre projet était de tester in vivo la possibilité de recolonisation de matrices valvulaires par des cellules autologues de moelle osseuse, les valves obtenues étant soumises à des forces mécaniques supposées être responsables de la recolonisation cellulaire et de la régénération de la matrice extra-cellulaire. La première étape a été l'optimisation d'un processus de décellularisation. Nous avons retenu un protocole combinant les effets de solutions hypotoniques et d'un détergent anionique, le sodium dodecyl sulfate. L'étape suivante a été de tester les propriétés mécaniques d'une valve xénogénique décellularisée dans un modèle ovin (qui est le modèle de référence en pathologie valvulaire cardiaque), en flux artériel systémique. Une matrice valvulaire porcine a été implantée dans une aorte thoracique descendante chez 6 agneaux. Ses propriétés mécaniques en contrainte systémique étaient bonnes, sans rupture ni dilatation anévrismale, 2 à 16 semaines après l'implantation. Nous avons ensuite testé la possibilité de colonisation de cette valve xénogénique décellularisée porcine par des cellules souches endogènes stimulées par l'injection de granulocyte-Colony Stimulating Factor (G-CSF). Ce montage a été implanté chez 6 agneaux puis une évaluation hémodynamique, macroscopique et histologique a été réalisée à 3, 6, 8 et 16 semaines. Alors que le G-CSF recombinant humain induisait une croissance significative du nombre de globules blancs périphériques chez l'agneau, l'effet sur la valve était délétère, et induisait des réactions inflammatoires et de fibrose ressemblant à un rejet de greffe après 16 semaines. Nous avons ensuite testé les propriétés mécaniques de cette valve après son implantation dans l'artère pulmonaire sous circulation extra-corporelle, ainsi que l'effet de l'injection in situ de cellules autologues mononucléées médullaires (CMM) juste avant l'implantation chirurgicale. Ces valves pulmonaires porcines décellularisées ont été implantées chez 15 agneaux. Chez 9 animaux, des CMM autologues ont été injectées dans la valve immédiatement avant son implantation (groupe CMM), et chez 6 animaux, aucune injection cellulaire n'était réalisée (groupe contrôle). Un suivi de 16 semaines était réalisé comprenant l'étude fonctionnelle de la valve (échographique et angiographique) ainsi qu'une étude histologique. Les évaluations échographiques ne montraient aucune régurgitation dans chacun des 2 groupes et les index de perméabilité valvulaire étaient similaires. Les études histologiques montraient une prolifération myointimale plus importante et des dépôts calciques étaient mis en évidence dans le groupe contrôle par rapport au groupe CMM. Toutes les valves étaient recouvertes d'une monocouche de cellules endothéliales. Cependant chez 2 animaux une infiltration inflammatoire importante était retrouvée dans l'adventice. Ces résultats suggéraient que l'injection in situ de cellules autologues médullaires pouvait réduire la détérioration de valves xénogéniques décellularisées, mais également dans des circonstances inconnues favoriser des réactions inflammatoires locales Nous avons alors supposé que l'injection in situ d'une sous-population de CMM, les cellules souches mésenchymateuses (CSM) pouvaient promouvoir in vivo la recolonisation de nos substituts valvulaire sans entraîner de risque d'augmentation des réactions inflammatoires locales. Nous avons prélevé des CCM autologues 7 jours avant l'implantation chirurgicale. De cet échantillon, des cellules souches mésenchymateuses (CSM) ont été isolées par une culture cellulaire spécifique. Les valves porcines décellularisées ont été implantées dans l'artère pulmonaire sous circulation extra-corporelle chez l'agneau, ayant été au préalable injectées soit de CMM (n=7), soit de CSM (n=7). L'évaluation fonctionnelle des valves a été réalisée après 16 semaines par échographie, les valves ont été explantées en vue de leur analyse macroscopique et histologique. Après 4 mois, les gradients moyens transvalvulaires et distaux étaient significativement plus bas dans le groupe avec CSM que dans le groupe CMM. L'index de perméabilité était également significativement plus élevé dans le groupe CSM que dans le groupe CMM.. L'examen histologique montrait également que la disposition de la matrice et la colonisation cellulaire était plus proche de celle de valve native dans le groupe CSM que dans le groupe CMM.

Page generated in 0.0663 seconds