Spelling suggestions: "subject:"ariable speed pump"" "subject:"aariable speed pump""
1 |
Návrh energeticky úsporného hydraulického systému pro silové zatěžování pohonných soustav vozidel / Energy efficient hydraulic system design for force loading of vehicle drivetrain systemsRobenek, Vít January 2015 (has links)
The thesis focuses on a hydraulic system design for a specific application of hydrostatic drive with regard to energy efficiency of proposed solution. Standard hydraulic and electronic components are used, mostly products of Bosch Rexroth. The aim of the thesis is to carry out a complex design from mechanic through hydraulic up to the electronic part of the system. After a short introduction in the beginning of the thesis is the particular application described and analyzed. Then the elemental principles of hydraulic devices and systems are explained. In the following part the actual solution is presented, which expands to several different alternatives. These alternatives are compared according to set criteria and the selected alternative is then further developed. At the end of the thesis, the outputs are evaluated and the direction of further possible improvements in the design is outlined.
|
2 |
Modeling And Experimental Evaluation Of Variable Speed Pump And Valve Controlled Hydraulic Servo DrivesCaliskan, Hakan 01 September 2009 (has links) (PDF)
In this thesis study, a valveless hydraulic servo system controlled by two
pumps is investigated and its performance characteristics are compared with a
conventional valve controlled system both experimentally and analytically. The
two control techniques are applied on the position control of a single rod linear
actuator. In the valve controlled system, the flow rate through the actuator is
regulated with a servovalve / whereas in the pump controlled system, two variable
speed pumps driven by servomotors regulate the flow rate according to the needs of
the system, thus eliminating the valve losses.
To understand the dynamic behaviors of two systems, the order of the
differential equations defining the system dynamics of the both systems are reduced
by using the fact that the dynamic pressure changes in the hydraulic cylinder
chambers become linearly dependent on leakage coefficients and cylinder chamber
volumes above and below some prescribed cut off frequencies. Thus the open loop
speed response of the pump controlled and valve controlled systems are defined by
v
second order transfer functions. The two systems are modeled in MATLAB
Simulink environment and the assumptions are validated.
For the position control of the single rod hydraulic actuator, a linear state
feedback control scheme is applied. Its state feedback gains are determined by
using the linear and linearized reduced order dynamic system equations. A linear
Kalman filter for pump controlled system and an unscented Kalman filter for valve
controlled system are designed for estimation and filtering purposes.
The dynamic performances of both systems are investigated on an
experimental test set up developed by conducting open loop and closed loop
frequency response and step response tests. MATLAB Real Time Windows Target
(RTWT) module is used in the tests for application purposes.
|
3 |
Simulação computacional de bombas com velocidade de rotação variável no EPANET / Computer simulation of variable speed pumps in EPANETCoutinho, Ricardo Santos 10 December 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-01-29T17:14:46Z
No. of bitstreams: 2
Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-01T11:58:11Z (GMT) No. of bitstreams: 2
Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-01T11:58:11Z (GMT). No. of bitstreams: 2
Dissertação - Ricardo Santos Coutinho - 2015.pdf: 10137543 bytes, checksum: 50b06893fd31466aedf36ff57ca15495 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2015-12-10 / In water distribution systems, most of the electricity is consumed by pumping
systems. Thus, reducing the inefficiency of the pump can provide significant energy
savings. This can be achieved by substituting fixed-speed pumps by variable-speed
pumps (VSP). However, the high costs of installation and operation of the VSPs
require a preliminary economic assessment of the design, which is usually
accompanied by the use of hydraulic solvers to simulate the behavior of the water
network. One of the most used softwares for this purpose is the EPANET 2, which
uses the gradient method for the hydraulic analysis of the steady flow. However, the
EPANET 2 is inaccurate when computing the VSP efficiency. This is because the
software does not take into account the changes in the pump efficiency curve when
the pump speed is changed. In this study, a routine for calculating VSPs efficiency,
based on the Sârbu and Borza (1998) formula, is implemented in the source code of
the EPANET 2. The influence of the new routine on the results predicted by the
software for efficiency, power and energy consumption of the VSP is evaluated in
simulations with a hypothetical network. The results showed that the original version
of EPANET 2 tends to underestimate the efficiency and thus overestimate the power
and energy consumption of the VSPs. In the present case, the energy consumption
of the system predicted by the original version of EPANET 2 was 21.99% higher than
the predicted by the modified version. These results point out that the modified
version of EPANET 2 provides a better prediction of VSPs behavior and thus its use
is recommended in the simulation of water distribution networks equipped with VSPs. / Em redes de distribuição de água, a maior parte da energia elétrica é consumida
pelos sistemas de bombeamento. Deste modo, a redução da ineficiência das
bombas pode proporcionar uma economia expressiva de energia. Isto pode ser
alcançado pela substituição de bombas de rotação constante por bombas de rotação
variável (BRVs). No entanto, os elevados custos de instalação e operação de BRVs
requerem uma avaliação econômica prévia do projeto, a qual geralmente é
acompanhada do uso de simuladores hidráulicos para simular o comportamento da
rede. Um dos programas mais utilizados para este fim é o EPANET 2, o qual
emprega o Método Gradiente para a análise hidráulica do escoamento permanente.
Todavia, o EPANET 2 é impreciso ao computar a eficiência de BRVs. Isto ocorre
porque o programa não leva em conta a mudança na curva de eficiência da bomba
quando sua velocidade de rotação é alterada. No presente trabalho, uma rotina para
o cálculo da eficiência de BRVs, baseada na fórmula de Sârbu e Borza (1998), é
implementada no código-fonte do EPANET 2. A influência da nova rotina nos
resultados previstos pelo programa para a eficiência, potência e consumo de energia
de BRVs é avaliada em simulações com uma rede hipotética. Os resultados
mostraram que a versão original do EPANET 2 tende a subestimar a eficiência e,
consequentemente, superestimar a potência e o consumo de energia de BRVs. No
caso em tela, o consumo de energia do sistema previsto pela versão original do
EPANET 2 foi 21,99% maior que o previsto pela versão modificada. Tais resultados
apontam que a versão modificada do EPANET 2 proporciona uma melhor previsão
do comportamento de BRVs e, portanto, o seu uso é recomendado na simulação de
redes de distribuição de água equipadas com BRVs.
|
Page generated in 0.0775 seconds