1 |
Optimum PWM strategies for microprocessor controlled three phase invertersClark, Paul R. January 1993 (has links)
No description available.
|
2 |
Microprocessor control of a switched reluctance motorLewin, Paul Leonard January 1994 (has links)
No description available.
|
3 |
Steady state analysis of the chopper controlled static Kramer driveRefoufi, L. January 1991 (has links)
No description available.
|
4 |
Investigation and mitigation of the adverse effects of PWM adjustable speed drivesZhang, Haoran 15 December 1998 (has links)
With the introduction of high speed semiconductor power devices and the
increased application of adjustable speed drives (ASDs) for efficient speed control of ac
motors, there has been a growing number of costly motor-drive related process failures. It
has been found that the high dv/dt and high switching frequency have caused premature
motor insulation failures due to motor terminal over-voltages (exacerbated by longer
cable lengths). It is also acknowledged that high dv/dt and high frequency common-mode
voltages generated by pulse-width modulated (PWM) inverters contribute significantly to
electromagnetic interference (EMI) and may also cause damaging bearing and leakage
currents. In response to these problems, a variety of mitigation techniques have been
proposed in the past. However, the known solutions usually address these problems one
at a time and some of the mitigation techniques are not highly effective.
The major objective of this research is to search for solutions to these ASD
application issues with an emphasis on solving all of the problems at the source.
Therefore, theoretical analysis of all the above adverse effects are presented and the
existing mitigation techniques are evaluated in this dissertation. It is found that common-mode
voltage is the major cause of both bearing currents and the conducted EMI, thus the
research is focused on new inverter topologies and control strategies in order to eliminate
the common-mode voltage. To achieve the goal of common-mode voltage cancellation, a
novel dual-bridge inverter (DBI) is proposed and studied. The DBI employs an additional
inverter output stage to drive a standard three-phase dual-voltage induction motor and is
controlled to generate balanced excitation of the motor resulting in a zero common-mode
voltage. It is shown through experimental results that the motor bearing current is
eliminated and the conducted EMI is significantly reduced.
In addition to the DBI, multilevel inverter topologies have also been studied. It
has been found in this research that with proper selections of the switching states, certain
multilevel PWM inverters will not generate common-mode voltages. This new control
method is verified in simulation by using both sine-triangle intersection PWM (SPWM)
and voltage space-vector modulation (SVM). / Graduation date: 1999
|
5 |
Design and analysis of a modified power split continuously variable transmissionFox, Andrew J., January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2003. / Title from document title page. Document formatted into pages; contains x, 100 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 82-84).
|
6 |
Harmonic mitigation using a modified slip energy recovery systemRouaud, Didier G. 05 1900 (has links)
No description available.
|
7 |
A DSP controlled multi-level inverter providing DC-link voltage balancing, ride-through enhancement and common-mode voltage elimination /Dai, Shaoan. January 2003 (has links)
Thesis (Ph. D.)--Oregon State University, 2004. / Printout. Includes bibliographical references (leaves 75-79). Also available on the World Wide Web.
|
8 |
HARMONIC INVESTIGATION IN LOW AND MEDIUM VOLTAGE NETWORKS USING COMPUTER SIMULATION AND MEASUREMENT DEVICESEgner, Sean Robert William 31 October 2006 (has links)
Student Number : 9811492X -
MSc dissertation -
School of Electrical and Information Engineering -
Faculty of Engineering and the Built Environment / This dissertation discusses the development of an ATP model of a network
to aid measurement techniques in a harmonic evaluation. A theoretical back-
ground discussion of various pieces of equipment and their signi#12;cance to har-
monics is included.
National Electricity Regulator (NRS 048) standards are discussed with refer-
ence to performing a basic investigation and short comings. A test study was
performed on the Brandspruit Mine in Secunda.
ATP models are developed for equipment relevant to the test case, these in-
clude AC{AC converters, AC{DC converters, three phase transformers and
cables. Finally the measured test case is compared to simulation results and
conclusions drawn.
|
9 |
Voltage sag and momentary interruption ride-through for adjustable speed drivesvan Zyl, Annabelle 15 December 1998 (has links)
The awareness of electric power quality has increased over the past decade as electronic equipment
has become more susceptible to power disturbances. The most disruptive power disturbances are voltage
sags and momentary interruptions and their effect on adjustable speed drives (ASDs) is studied in this
thesis.
Several solutions have been suggested to provide only voltage sag ride-through to ASDs, but most
solutions focus on ASDs with passive rectifiers since they hold the largest share of the market. This thesis
focuses on ASDs with active rectifiers, which is an emerging and growing market due to the advantages
of four quadrant operation and reduced harmonics offered. A solution is presented which provides an
ASD with an active rectifier with the capability to ride through the most common sags in order to reduce
the frequency at which the ASD trips and thereby increase its reliability.
In order to provide ASDs with the capability to ride through momentary interruptions, it is
necessary to interface an energy storage system to the ASD. Flywheels, ultra-capacitors and batteries are
evaluated for use in an energy storage system to provide voltage sag and momentary interruption ride-through
and a detailed comparison of six systems based on these technologies is presented. The interface
circuit between the energy storage system and ASD has a significant influence on the performance of the
energy storage system and therefore interface circuits to ASDs with passive and active rectifiers are
studied.
The addition of an ultra-capacitor energy storage system to an ASD with an active rectifier in order
to provide ride-through of deeper sags and momentary interruptions is studied and a fuzzy logic controller
is designed to enhance system performance. Initially, no communication between the ASD and the ultra-capacitor
system is assumed and the ultra-capacitor system can therefore be added as a retro-fit to an
existing ASD. It is, however, foreseen that the market for ASDs with ride-through capability of voltage
sags and momentary interruptions will grow and the concepts for an integrated design of an ASD and an
energy storage system are presented. / Graduation date: 1999
|
10 |
Design procedure for brushless doubly-fed machine used as a limited speed-range pump driveAlajmi, Abdulhadi M. 29 October 1993 (has links)
The continuing desire of industry to further improve process efficiency,
through tighter control and energy conservation, has prompted users to pay closer
attention to Adjustable Speed Drives (ASDs). The conventional ASDs consist of
induction or synchronous motors controlled by power electronic controllers through
the adjustment of supply frequency and line voltage. The drawback of these
conventional ASDs lies in the high cost of the power electronic controllers which
have the same rating as that of the machine itself.
The Brush less Doubly-Fed Machine (BDFM) ASD has proven, both
analytically and experimentally, to provide a cost effective and a wide range of
precise speed control. The experimental BDFM prototypes built to date were
designed and constructed individually based on designers' experience with self-cascaded
machines. The success with these prototypes has promoted the idea of
standardizing the design procedure for all future BDFMs. This thesis offers a
general design procedure for the BDFM, which can serve as a first step in
standardizing the manufacturing process of this machine. The procedure is
presented in the form of a demonstration, by applying it to the design of a 60-hp,
600 to 900 r/min, 460-volts BDFM pump drive to replace the currently utilized
conventional 60-hp wound rotor induction motor ASD. An ideal design, which
determines machine details such as physical dimensions, slot specifics and
conductor details based on conservative magnetic and electric loading assumptions,
is one form of the design procedure. The other form, the practical design, involves
utilizing a specified physical dimensions and slot details to determine the associated
conductors' details and to insure the compliance of machine loadings with up-to-date
industrial standards. In both procedures, the design will be made to satisfy, if
not to exceed, the existing conventional drive performance. / Graduation date: 1994
|