Spelling suggestions: "subject:"entilation distribution"" "subject:"centilation distribution""
1 |
The effects of IPPB on ventilation distribution in high risk adults following open upper abdominal surgery using electrical impedance tomographyRoss, Nicolette Hayley 04 1900 (has links)
Thesis (MScPhysio)--Stellenbosch University, 2015. / ENGLISH ABSTRACT: Question: What are the effects of Intermittent Positive Pressure Breathing (with and without a
Positive End Expiratory Pressure [PEEP] Valve), compared to deep breathing exercises, on
ventilation distribution in high-risk adults following open upper abdominal surgery (UAS)?
Design: This study comprised an observational descriptive component as well as a prospective
triple blind randomised controlled crossover trial with concealed allocation and patient,
assessor and statistician blinding
Participants: Seven patients at high risk for postoperative pulmonary complications following
UAS
Intervention: Deep breathing exercises (DBExs) were compared to Intermittent Positive
Pressure Breathing (IPPB), with IPPB further applied with and without a PEEP Valve, using a
randomised cross-over design with 30 minute washout duration between periods.
Outcome measures: Global and regional impedance changes in the lungs were measured using
Electrical Impedance Tomography. Vital signs, visual analogue pain scale (VAS) and modified
Borg scale (MBS) were measured pre– and post-intervention.
Results: A greater mean global lung impedance change ( Z) was detected with IPPB compared
to DBExs (mean difference in Z 2803.8; 95% CI 5189.9 to 8512.5 and 2046 to 96047.9;
P<0.01). These changes in lung impedance lasted 30 minutes before returning to baseline.
There was no difference in Z when patients received IPPB with 5cmH20 PEEP compared to
IPPB with no PEEP. No specific regional ventilation changes were noted. IPPB did not increase
VAS, MBS scores or adversely affect vital signs.
Conclusion: IPPB is an effective technique to improve lung volumes compared to deep
breathing exercises. Further studies are required to investigate the effect of IPPB on clinical
outcome. / AFRIKAANSE OPSOMMING:
Vraag: Watter uitwerking het onderbroke positiewe-drukasemhaling (met én sonder ’n
positiewe-endekspiratoriesedruk-[PEEP-]klep) in vergelyking met diepasemhalings-oefeninge
op ventilasieverspreiding by hoërisikovolwassenes ná bo-buikchirurgie?
Ontwerp: ’n Waarnemingsgegronde, vergelykende en ondersoekende, driedubbelblinde,
verewekansigde gekontroleerde oorskakelproef, met verborge toewysing en blinding van
pasiënte, die assesseerder en statistikus
Deelnemers: Sewe pasiënte met ’n hoë risiko vir post-operatiewe pulmonêre komplikasies na
bo-buikchirurgie
Intervensie: Diepasemhalingsoefeninge (DBEx) is vergelyk met onderbroke positiewedrukasemhaling
(IPPB), wat op sy beurt met én sonder ’n PEEP-klep toegepas is, met behulp
van ’n verewekansigde oorskakelstudie met ’n halfuur lange uitspoeling tussen oorskakelings.
Uitkomsmetings: Algehele en regionale impedansieveranderinge in die longe is met behulp
van elektriese impedansietomografie gemeet. Vitale tekens, die visuele analoogskaal (VAS) en
die aangepaste Borg-skaal (MBS) is voor, sowel as na die intervensie afgeneem.
Resultate: ’n Groter gemiddelde algehele impedansieverandering ( Z) is opgemerk met IPPB
in vergelyking met DBEx (gemiddelde verskil 2803.8; 95% CI 5189.9: 8512.5 en 2046:
96047.9; P<0.01). Hierdie veranderinge in longimpedansie het ’n halfuur of langer geduur
voordat dit na die basislyn teruggekeer het. Daar was geen verskil in Z toe pasiënte IPPB met
’n PEEP-klep van 5cmH20 ontvang het teenoor IPPB sonder ’n PEEP-klep nie. Geen spesifieke
regionale voorkeure is opgemerk nie. IPPB het nie die VAS- of MBS-tellings verhoog of vitale
tekens verswak nie.
Stellenbosch University https://scholar.sun.ac.za
iv
Gevolgtrekking: In vergelyking met DBEx, is IPPB ’n doeltreffende tegniek om longvolumes
te verbeter. Verdere studies word vereis om die uitwerking van IPPB op kliniese uitkomste te
ondersoek.
|
2 |
The heat load in district heating systemsWerner, Sven January 1984 (has links)
This thesis considers the composition of the daily heat load in six Swedish district heating systems supplying heat for space heating and hot water supply. The analysis was performed by bringing together a heat load model and series of daily heat load observations covering periods ranging from five to eleven years. The influences of transient heat transmission, solar gain, and wind infiltration are found to be significant but small. It is shown that a natural self control of water radiators affects the magnitude of these influences when the control systems are incomplete. The annual fraction of each heat load component, the composition of the heat load duration graph, and the long term changes in heat consumption are presented. Furthermore, the heat load composition estimated facilitates future heat load simulations in order to quantify the outcome of various energy conservation measures with respect to reductions in design heat load and annual heat demand.
|
Page generated in 0.1897 seconds