• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeitos da substituição vestibular eletrotátil na reabilitação de pacientes com arreflexia vestibular bilateral / Effects of electrotactile vestibular substitution on rehabilitation of patients with bilateral vestibular loss

Camila de Giacomo Carneiro Barros 13 April 2011 (has links)
O presente estudo avaliou a eficácia do equipamento de biofeedback eletrotátil lingual (BrainPort®) como substituto sensorial para o aparelho vestibular em pacientes com arreflexia vestibular bilateral (AVB) que não obtiveram boa resposta à terapia convencional de reabilitação vestibular (RV). Sete pacientes com AVB foram treinados a usar o equipamento. A estimulação na superfície da língua foi criada por um padrão dinâmico de pulsos elétricos e o paciente capaz de ajustar a intensidade de estimulação e centralizar o estímulo na placa de eletrodos. Os pacientes foram orientados a continuamente ajustar a orientação do posicionamento da cabeça e a manter o padrão de estímulos no centro da placa. Tarefas posturais que apresentavam dificuldade progressiva foram realizadas durante o uso do equipamento. A distribuição do índice de equilíbrio do teste de integração sensorial (TIS) pré e pós-tratamento mostrou valores médios de 38.3±8.7 e 59.9±11.3, respectivamente, indicando melhora significante estatisticamente (p=0,01). O aparelho de feedback eletrotátil lingual melhorou significantemente o controle postural no grupo de estudo, superando a melhora obtida com a RV convencional. O sistema de biofeedback eletrotátil foi capaz de fornecer informações adicionais sobre o posicionamento da cabeça em relação à orientação vertical gravitacional na ausência da aferência vestibular, melhorando o controle postural. Pacientes com AVB podem integrar a informação eletrotátil no controle da postura com o objetivo de melhorar a estabilidade após a RV convencional. Estes resultados foram obtidos e verificados, não apenas pelo questionário subjetivo, mas também pelo índice de equilíbrio do TIS. As limitações do estudo foram o tamanho reduzido da amostra e a curta duração do seguimento. Os presentes achados mostram que a substituição sensorial mediada pelo feedback eletrotátil lingual pode contribuir para a melhora do equilíbrio nesses pacientes se comparada à RV / The present study evaluated the effectiveness of electrotactile tongue biofeedback (BrainPort®) as a sensory substitute for the vestibular apparatus in patients with bilateral vestibular loss (BVL) who did not have a good response to conventional vestibular rehabilitation (VR). Seven patients with BVL were trained to use the device. Stimulation on the surface of the tongue was created by a dynamic pattern of electrical pulses and the patient was able to adjust the intensity of stimulation and spatially centralize the stimulus on the electrode array. Patients were directed to continuously adjust head orientation and to maintain the stimulus pattern at the center of the array. Postural tasks that present progressive difficulties were given during the use of the device. Pre- and post-treatment distribution of the sensory organization test (SOT) composite score showed an average value of 38.3±8.7 and 59.9±11.3, respectively, indicating a statistically significant improvement (p = 0.01). Electrotactile tongue biofeedback significantly improved the postural control of the study group, even if they had not improved with conventional VR. The electrotactile tongue biofeedback system was able to supply additional information about head position with respect to gravitational vertical orientation in the absence of vestibular input, improving postural control. Patients with BVL can integrate electrotactile information in their postural control in order to improve stability after conventional VR. These results were obtained and verified not only by the subjective questionnaire but also by the SOT composite score. The limitations of the study are the small sample size and short duration of the follow-up. The current findings show that the sensory substitution mediated by electrotactile tongue biofeedback may contribute to the improved balance experienced by these patients compared to VR
2

Efeitos da substituição vestibular eletrotátil na reabilitação de pacientes com arreflexia vestibular bilateral / Effects of electrotactile vestibular substitution on rehabilitation of patients with bilateral vestibular loss

Barros, Camila de Giacomo Carneiro 13 April 2011 (has links)
O presente estudo avaliou a eficácia do equipamento de biofeedback eletrotátil lingual (BrainPort®) como substituto sensorial para o aparelho vestibular em pacientes com arreflexia vestibular bilateral (AVB) que não obtiveram boa resposta à terapia convencional de reabilitação vestibular (RV). Sete pacientes com AVB foram treinados a usar o equipamento. A estimulação na superfície da língua foi criada por um padrão dinâmico de pulsos elétricos e o paciente capaz de ajustar a intensidade de estimulação e centralizar o estímulo na placa de eletrodos. Os pacientes foram orientados a continuamente ajustar a orientação do posicionamento da cabeça e a manter o padrão de estímulos no centro da placa. Tarefas posturais que apresentavam dificuldade progressiva foram realizadas durante o uso do equipamento. A distribuição do índice de equilíbrio do teste de integração sensorial (TIS) pré e pós-tratamento mostrou valores médios de 38.3±8.7 e 59.9±11.3, respectivamente, indicando melhora significante estatisticamente (p=0,01). O aparelho de feedback eletrotátil lingual melhorou significantemente o controle postural no grupo de estudo, superando a melhora obtida com a RV convencional. O sistema de biofeedback eletrotátil foi capaz de fornecer informações adicionais sobre o posicionamento da cabeça em relação à orientação vertical gravitacional na ausência da aferência vestibular, melhorando o controle postural. Pacientes com AVB podem integrar a informação eletrotátil no controle da postura com o objetivo de melhorar a estabilidade após a RV convencional. Estes resultados foram obtidos e verificados, não apenas pelo questionário subjetivo, mas também pelo índice de equilíbrio do TIS. As limitações do estudo foram o tamanho reduzido da amostra e a curta duração do seguimento. Os presentes achados mostram que a substituição sensorial mediada pelo feedback eletrotátil lingual pode contribuir para a melhora do equilíbrio nesses pacientes se comparada à RV / The present study evaluated the effectiveness of electrotactile tongue biofeedback (BrainPort®) as a sensory substitute for the vestibular apparatus in patients with bilateral vestibular loss (BVL) who did not have a good response to conventional vestibular rehabilitation (VR). Seven patients with BVL were trained to use the device. Stimulation on the surface of the tongue was created by a dynamic pattern of electrical pulses and the patient was able to adjust the intensity of stimulation and spatially centralize the stimulus on the electrode array. Patients were directed to continuously adjust head orientation and to maintain the stimulus pattern at the center of the array. Postural tasks that present progressive difficulties were given during the use of the device. Pre- and post-treatment distribution of the sensory organization test (SOT) composite score showed an average value of 38.3±8.7 and 59.9±11.3, respectively, indicating a statistically significant improvement (p = 0.01). Electrotactile tongue biofeedback significantly improved the postural control of the study group, even if they had not improved with conventional VR. The electrotactile tongue biofeedback system was able to supply additional information about head position with respect to gravitational vertical orientation in the absence of vestibular input, improving postural control. Patients with BVL can integrate electrotactile information in their postural control in order to improve stability after conventional VR. These results were obtained and verified not only by the subjective questionnaire but also by the SOT composite score. The limitations of the study are the small sample size and short duration of the follow-up. The current findings show that the sensory substitution mediated by electrotactile tongue biofeedback may contribute to the improved balance experienced by these patients compared to VR
3

Eficácia do equipamento  de biofeedback vibrotátil Vertiguard® na reabilitação do equilibrio corporal / Efficacy of biofeedback equipment vibrotactile Vertiguard® on vestibular rehabilitation

Brugnera, Cibele 27 August 2014 (has links)
O presente estudo avaliou a eficácia do equipamento de biofeedback Vertiguard®), que utiliza a informação vibrotátil como substituto sensorial (SS) de apoio ao sistema vestibular. Foram selecionados 13 pacientes com comprometimento severo do equilíbrio corporal e não obtiveram resultado satisfatório à terapia de reabilitação vestibular convencional. Os sujeitos foram randomizados entre dois grupos controle (GC), que utilizou o estímulo vibratório e estudo (GE), que treinou com o equipamento desligado. Os indivíduos foram treinados com o equipamento durante dez dias e foram orientados a corrigir o alinhamento corporal sempre que recebessem um estímulo vibrotátil de um cinto com quatro vibradores dispostos em ângulo de 90°entre eles, que informava o desvio corporal para aquele lado e o risco de queda. Para avaliação pré e pós tratamento foi utilizada o protocolo Teste de Integração Sensorial (TIS) da Posturografia Dinâmica Computadorizada (PDC) e duas escalas de auto percepção do equilíbrio: ABC (Activities-specific Balance Confidence) e DHI (Dizziness Handicap Inventory). O GE apresentou melhora estatisticamente significante em C5 (p=0,007) e C6 (p= 0,012) após treinamento. Na escala ABC houve diferença significante entre o início e o final do tratamento apenas no GE (p=0,04). No questionário DHI ocorreu diferença significante no aspecto físico nos GC e GE, e no aspecto funcional (p=0,0427) apenas no grupo GE. Os resultados observados demonstram que o estímulo de substituição sensorial vibratório oferecido pelo sistema Vertiguard®, propicia a melhor integração das redes neurais envolvidas na manutenção da postura, melhorando as estratégias utilizadas na recuperação do equilíbrio corporal / This study evaluated the effectiveness of biofeedback equipment Vertiguard® that uses vibrotactile information as sensory substitution (SS) of the vestibular system. We selected thirteen patients with severe impairment of balance who did not obtain enough improvement from conventional vestibular rehabilitation. A randomization list was used to distribute the patients in Control Group (CG), who received the vibrotactile stimulus and Study Group (SG), who trained without any stimulus. During ten days of training, the patients in both groups used the equipment attached to the waist. They were instructed to correct body alignment when vibrotactile stimulus received from one of the four vibrators arranged at an angle of 90° signaling the risk of f alling. The results of the treatment were evaluated by the protocol sensory organization test (SOT) of the computerized dynamic posturography (CDP), ABC scale (Activities-specific Balance Confidence) and DHI (Dizziness Handicap Inventory). After treatment the SG showed a statistically significant improvement in C5 (p = 0.007) and C6 (p = 0.012). In the ABC scale there was significant difference between the beginning and end of treatment only in the SG (p = 0.04). The Dizziness Handicap Inventory questionnaire (DHI) showed in the after training a significant difference in functional in both CG and SG, and in physical aspects (p = 0.0427) only in SG. The present findings show that sensory substitution using the vibrotactile stimulus of Vertiguard (R) system promotes the improvement of neural networks involved in maintaining posture, improving the strategies used in the recovery of body balance
4

Eficácia do equipamento  de biofeedback vibrotátil Vertiguard® na reabilitação do equilibrio corporal / Efficacy of biofeedback equipment vibrotactile Vertiguard® on vestibular rehabilitation

Cibele Brugnera 27 August 2014 (has links)
O presente estudo avaliou a eficácia do equipamento de biofeedback Vertiguard®), que utiliza a informação vibrotátil como substituto sensorial (SS) de apoio ao sistema vestibular. Foram selecionados 13 pacientes com comprometimento severo do equilíbrio corporal e não obtiveram resultado satisfatório à terapia de reabilitação vestibular convencional. Os sujeitos foram randomizados entre dois grupos controle (GC), que utilizou o estímulo vibratório e estudo (GE), que treinou com o equipamento desligado. Os indivíduos foram treinados com o equipamento durante dez dias e foram orientados a corrigir o alinhamento corporal sempre que recebessem um estímulo vibrotátil de um cinto com quatro vibradores dispostos em ângulo de 90°entre eles, que informava o desvio corporal para aquele lado e o risco de queda. Para avaliação pré e pós tratamento foi utilizada o protocolo Teste de Integração Sensorial (TIS) da Posturografia Dinâmica Computadorizada (PDC) e duas escalas de auto percepção do equilíbrio: ABC (Activities-specific Balance Confidence) e DHI (Dizziness Handicap Inventory). O GE apresentou melhora estatisticamente significante em C5 (p=0,007) e C6 (p= 0,012) após treinamento. Na escala ABC houve diferença significante entre o início e o final do tratamento apenas no GE (p=0,04). No questionário DHI ocorreu diferença significante no aspecto físico nos GC e GE, e no aspecto funcional (p=0,0427) apenas no grupo GE. Os resultados observados demonstram que o estímulo de substituição sensorial vibratório oferecido pelo sistema Vertiguard®, propicia a melhor integração das redes neurais envolvidas na manutenção da postura, melhorando as estratégias utilizadas na recuperação do equilíbrio corporal / This study evaluated the effectiveness of biofeedback equipment Vertiguard® that uses vibrotactile information as sensory substitution (SS) of the vestibular system. We selected thirteen patients with severe impairment of balance who did not obtain enough improvement from conventional vestibular rehabilitation. A randomization list was used to distribute the patients in Control Group (CG), who received the vibrotactile stimulus and Study Group (SG), who trained without any stimulus. During ten days of training, the patients in both groups used the equipment attached to the waist. They were instructed to correct body alignment when vibrotactile stimulus received from one of the four vibrators arranged at an angle of 90° signaling the risk of f alling. The results of the treatment were evaluated by the protocol sensory organization test (SOT) of the computerized dynamic posturography (CDP), ABC scale (Activities-specific Balance Confidence) and DHI (Dizziness Handicap Inventory). After treatment the SG showed a statistically significant improvement in C5 (p = 0.007) and C6 (p = 0.012). In the ABC scale there was significant difference between the beginning and end of treatment only in the SG (p = 0.04). The Dizziness Handicap Inventory questionnaire (DHI) showed in the after training a significant difference in functional in both CG and SG, and in physical aspects (p = 0.0427) only in SG. The present findings show that sensory substitution using the vibrotactile stimulus of Vertiguard (R) system promotes the improvement of neural networks involved in maintaining posture, improving the strategies used in the recovery of body balance

Page generated in 0.1585 seconds