• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento dieletrico de uma cadeia de isoladores de vidro de classe de tensão 138 KV com unidades danificadas

Monassi, Vitor 27 July 1988 (has links)
Orientador: Ioshiaki Doi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-14T19:47:25Z (GMT). No. of bitstreams: 1 Monassi_Vitor_M.pdf: 12557613 bytes, checksum: 18995fec957e58618c996595237c62ef (MD5) Previous issue date: 1988 / Resumo: Este trabalho tem por objetivo estudar o comportamento de cadeias de isoladores de vidro, utilizadas em linhas de transmissão de 138 kV, quando elas apresentam unidades danificadas. Quando um ou mais isoladores danificados passa a integrar a composição de uma cadeia, a suportabilidade dessa cadeia varia com o número de unidades danificadas e com o posicionamento que elas ocupam. O estudo do comportamento dielétrico de uma cadeia com isoladores de vidro com unidades danificadas é de grande interesse prático, pois está associado ao desempenho do sistema elétrico e a execução de manutenções com lina energizada ... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: When one or more broken units are present in the insulator string, its voltage strength changes with the location and distribution of broken units in the string. In generaI the broken or damage insuIators may affect the performance of the transmission Iines. On the other hand, it infIuences the Iive Iine maintenance safety conditions. This work studies the dielectric bchavior of the glass insulator strings of 138 kV transmission Iines with broken units under switching and Iightning impulse voltages and industrial frequence (60 Hz) voltage. Brief comments are made on Iive Iine maintenance tools and methods, as welI as some expected overvoltages on transmission Iines. The behavior of the gaps with and without insulator strings in them are also discussed and commented ... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0976 seconds