• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Regulation and Control of AC Microgrid Systems with Renewable Generation and Battery Energy Storage System

Zhao, Huiying January 2018 (has links)
No description available.
2

Topologia híbrida e métodos de controle aplicados à regulação de tensão de geradores de indução auto-excitados / Hybrid topology and control methods applied to voltage regulation of self-excited induction generators

Scherer, Lucas Giuliani 23 May 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This doctoral thesis deals with the study, analysis and development of a new hybrid topology for voltage regulation of stand-alone microgeneration systems employing self-excited induction generators. The hybrid topology proposed considers a three-phase four-wire system and employs a distribution static synchronous compensator (DSTATCOM) in combination with banks of switchable capacitors (BCC) to perform the regulation of the terminal voltages of the induction generator. As a result of using the proposed topology, it is expected the regulation of the amplitude of the terminal voltages of the induction generator, with effective reduction of the power processed by DSTATCOM, regardless of the characteristic of the applied load. Therefore, it is considered the compensation of reactive currents of the system in terms of phase, amplitude and shape, performed by a suitable control system. The control structure applied to control the DSTATCOM and the switching of BCC ensures the regulation of voltages with low harmonic distortion (THD) and reduced distortion factor among voltages, in addition to keeping the generator currents sinusoidal and balanced. This thesis also investigates two distinct forms of frequency control using the electronic load control: (i) auxiliary load controlled by chopper element connected to the DC bus DSTATCOM and (ii) auxiliary load controlled by chopper element connected to the AC bus system through non-controlled three-phase rectifier. Simulation and experimental results are presented to validate and demonstrate the suitable performance of the proposed hybrid topology in the regulation of voltages and system frequency. The system is tested by load transient including three-phase and single-phase loads, linear and non-linear loads, resistive and reactive loads. / Esta tese de doutorado trata do estudo, análise e desenvolvimento de uma nova topologia híbrida de regulação das tensões de sistemas isolados de microgeração empregando geradores de indução auto-excitados. A topologia híbrida proposta considera um sistema trifásico a quatro fios e emprega um compensador síncrono estático de distribuição (DSTATCOM) em associação a bancos de capacitores comutáveis (BCC) para efetuar a regulação das tensões terminais do gerador de indução. Como resultado da utilização da topologia proposta, espera-se a regulação da amplitude das tensões terminais do gerador, com efetiva redução da potência processada pelo DSTATCOM, independentemente da característica da carga aplicada. Considera-se, portanto, a compensação de correntes reativas do sistema em termos de fase, amplitude e forma, realizada a partir de sistema de controle adequado. A estrutura de controle aplicada ao controle do DSTATCOM e à comutação dos BCC, garante a regulação das tensões com reduzida taxa de distorção harmônica (THD) e reduzido fator de desequilíbrio de tensão (FD), além de manter as correntes do gerador senoidais e balanceadas. Neste trabalho também são investigadas duas formas distintas de controle de frequência a partir do controle eletrônico de carga: (i) carga auxiliar controlada por elemento chopper conectada ao barramento CC do DSTATCOM e (ii) carga auxiliar controlada por elemento chopper conectada ao barramento CA do sistema através de retificador trifásico não-controlado. Resultados de simulação e resultados experimentais são apresentados para validar e demonstrar o bom desempenho da topologia híbrida proposta na regulação das tensões e frequência do sistema. O sistema é testado mediante transitórios de cargas trifásicas e monofásicas, lineares e não-lineares, resistivas e reativas.

Page generated in 0.1532 seconds