Spelling suggestions: "subject:"water used to was clothes"" "subject:"later used to was clothes""
1 |
Avaliação crítica de um sistema de reúso de águas cinzasBaicere, Gonçalo Santana 29 August 2014 (has links)
Submitted by Simone Souza (simonecgsouza@hotmail.com) on 2017-10-13T13:40:21Z
No. of bitstreams: 1
DISS_2014_Gonçalo Santana Baicere.pdf: 2164770 bytes, checksum: 9a81e1203a8cdf334dbdf933b718d003 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-11-06T14:05:15Z (GMT) No. of bitstreams: 1
DISS_2014_Gonçalo Santana Baicere.pdf: 2164770 bytes, checksum: 9a81e1203a8cdf334dbdf933b718d003 (MD5) / Made available in DSpace on 2017-11-06T14:05:15Z (GMT). No. of bitstreams: 1
DISS_2014_Gonçalo Santana Baicere.pdf: 2164770 bytes, checksum: 9a81e1203a8cdf334dbdf933b718d003 (MD5)
Previous issue date: 2014-08-29 / O aumento do consumo de água potável tem refletido de forma direta no crescimento da
poluição e degradação quantitativa e qualitativa dos corpos d’água, receptores que são de
lançamentos de águas residuárias sem tratamento. Dessa forma, o desenvolvimento de
medidas e ações que possibilitem a conservação e a redução do consumo de água potável,
vem se tornando prioridades para algumas instituições. Este estudo visa o desenvolvimento e
avaliação de uma tecnologia simplificada de tratamento e operação, para o aproveitamento da
água de lavagem de roupa como fonte alternativa de abastecimento, para as descargas de
vasos sanitários nas residências. Assim foi necessário caracterizar as águas cinzas
provenientes da máquina de lavar roupas, nos seus aspectos físicos, químicos e
microbiológicos. O sistema de tratamento experimental foi operado e monitorado pelo
período de 12 meses, em uma residência com cinco moradores. O sistema de tratamento da
Estação Experimental era composto por um decantador, seguido de um filtro de areia aeróbio
de fluxo descendente e desinfecção com hipoclorito de sódio a 2% (água sanitária). Além de
avaliar a eficiência da estação experimental de acordo com os parâmetros físicos, químicos e
microbiológicos das normas e recomendações vigentes, foram monitorados os consumos de
água potável das residências, com objetivo de verificar se havia redução no consumo aferido
pela concessionária de saneamento, após a implantação do sistema de tratamento. O sistema
de tratamento adotado apresentou uma elevada eficiência na remoção média de turbidez, cor,
nitrato, coliformes totais, Escherichia coli, na ordem de 93,52, 94,18, 86,27, 100 e 100%,
respectivamente. Em relação a DBO5, DQO e SST, o sistema apresentou uma eficiência
média na ordem de 58,04, 55,72 e 60,29% de remoção. O efluente do sistema de tratamento
possui características compatíveis com diversos parâmetros estabelecidos para o reúso não
potável. / The growth in the consumption of potable water has reflected directly in the increase of
pollution and quantitative and qualitative degradation of the water bodies, receptors of
releases of untreated wastewater. Thus, the development of measures and programs that will
enable conservation and reduction of potable water consumption is becoming a priority for
some institutions. This study aims to develop and evaluate a simplified treatment and
operation technology to take advantage of laundry water as an alternative source of supply for
toilet flushing in homes. Thus it was necessary to characterize the physical, chemical and
microbiological aspects of the gray water coming from the washing machines. The
experimental treatment system was operated and monitored for a period of 12 months, in a
house with five people. The Experimental Station was composed of a decanter, followed by
an aerobic sand filter and disinfection with a filter with sodium hypochlorite at 2% (bleach).
Besides evaluating the efficiency of the experimental station in accordance with the physical,
chemical and microbiological standards of the existing guidelines and recommendations, the
consumption of potable water of the households were monitored, in order to verify if there
was a reduction in the consumption measured by the sanitation utilities, after the
implementation of the treatment system. The treatment system adopted showed a high
efficiency in the average removal of turbidity, color, nitrate, total coliforms and Escherichia
coli, of 93.52, 94.18, 86.27, 100 and 100%, respectively. In relation to BOD5, (Biochemical
Oxygen Demand) COD (Chemical Oxygen Demand) and TSS (Total Suspended Solids), the
system presented an average removal efficiency of 58.04, 55.72 and 60.29%. The effluent of
the treatment system has characteristics which are compatible with several parameters
established for the non potable reuse.
|
Page generated in 0.1272 seconds