• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise experimental de pilares de concreto armado, com carga excêntrica, reforçados com chumbadores e concreto autoadensável (CAA) / Experimental analysis of reinforced concrete columns, under eccentric load, reinforced with wedge bolts and self compacting concrete (SCC)

Virgens, Jeovan Pereira das 16 October 2015 (has links)
Submitted by Cláudia Bueno (claudiamoura18@gmail.com) on 2016-03-31T19:38:48Z No. of bitstreams: 2 Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-04-04T11:45:04Z (GMT) No. of bitstreams: 2 Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-04-04T11:45:04Z (GMT). No. of bitstreams: 2 Dissertação - Jeovan Pereira das Virgens - 2015.pdf: 10009095 bytes, checksum: a8f3d2a6914adbb0c7cdcf49732ffc57 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-10-16 / This paper presents the experimental study of reinforcement concrete columns reinforced with wedge bolts and a 35 mm self compacting concrete jacket at the most compressed face. Nine columns with a 2000 mm height subjected to flexure and bending with initial eccentricity of 60 mm, named as: original column (Po) with a cross section of 120 mm x 250 mm; reference column (Pref) with a cross section of 155 mm x 250 mm and seven columns with a initial cross section of 120 mm x 250 mm, and later reinforced by the addition of 35 mm reinforcing layer, and various configurations of wedge bolts at its most compressed face. Except for the original column (Po), the columns were submitted to a 42.5 mm load eccentricity due to the attached concrete layer at the compressed face. Although failure of the wedge bolts did not accour, it was not possible to prevent detachment of the reinforcing layer. The results indicate that it is possible to structural rehabilitate reinforce concrete columns with the use of the strengthening methodology used in this research, resulting in average load capacity gains of 3,71 times compared to original column load (Po). / O presente trabalho apresenta o estudo experimental de pilares de concreto armado reforçados com parafusos chumbadores e acréscimo de camada com 35 mm de concreto autoadensável na face comprimida. Nove pilares, com alturas de 2000 mm, foram submetidos à flexão composta reta com excentricidade inicial de 60 mm, assim discriminados: um pilar original (Po) com seção transversal de 120 mm x 250 mm; um pilar de referência (Pref) com seção transversal de 155 mm x 250 mm e sete pilares, inicialmente moldados com seção transversal de 120 mm x 250 mm, e após, reforçados através da adição de camada de reforço de 35 mm e diversas configurações de posições de parafusos chumbadores na face comprimida. Exceto o pilar original (Po), os pilares foram submetidos à excentricidade inicial de carga de 42,5 mm, devido ao acréscimo da camada de reforço na face comprimida. Apesar de não ocorrer ruptura dos parafusos chumbadores, não foi possível evitar o desplacamento da camada de reforço. Os resultados obtidos indicam que é possível a reabilitação estrutural de pilares de concreto armado com o uso da metodologia de reforço empregada, obtendo ganho de capacidade de carga média de 3,71 vezes em relação ao pilar original (Po).
2

Análise do comportamento de pilares de concreto armado reforçados com chumbadores e concreto auto adensável / Analysis of the behavior of reinforced concrete columns strengthened with sleeve wedge bolts and a self-compacting concrete layer

Marques, Marília Gonçalves 11 April 2014 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-03-05T20:16:17Z No. of bitstreams: 2 Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-03-05T20:16:35Z (GMT) No. of bitstreams: 2 Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-03-05T20:16:35Z (GMT). No. of bitstreams: 2 Dissertação - Marília Gonçalves Marques - 2014.pdf: 6536401 bytes, checksum: 080ea60c6004cee2f33a28aab0065b39 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2014-04-11 / Strengthening of reinforced concrete columns by jacketing is one of the most common structural rehabilitation techniques in Brazil. For adequate performance, it is necessary, among others, to avoid detachment of the new concrete layer (strengthening material) from the old concrete substrate when the strengthened member is again in service conditions. This paper describes the test results of eight reinforced concrete rectangular columns subjected to combined compression and one-axis bending to evaluate the efficiency of using sleeve wedge bolts across the new concrete/old concrete interface to avoid detachment. The strengthening technique, in this case, consisted of adding a layer of self-compacting concrete to one column face. Two columns tested were monolithic and named PO (original column) e PR (reference column). The other six columns were strengthened using a new 35 mm thick self-compacting concrete layer attached to the column face subjected to highest compressive stresses. Column PO had a 120mm by 250 mm rectangular cross section and its results gave information about column behavior without the use of strengthening. Column PR had a 155mm by 250 mm rectangular cross section and its cross section dimensions matched the strengthened columns but it was cast monolithically. To improve bond conditions between the existing concrete and the new concrete, the concrete surface was roughened and the outermost aggregate was exposed using hydro jetting. Holes along the concrete surface were made to insert the wedge bolts responsible for increasing the bond between the two concrete surfaces. The difference among the six strengthened columns consisted in the position and amount of bolts used. Results indicate the position and amount of the bolts significantly alters the strength capacity of the strengthened columns since premature rupture by concrete detachment was delayed. The reinforcement used was increased approximately three times the ultimate load of the original column, indicating the good performance of reinforcement. / ANÁLISE DO COMPORTAMENTO DE PILARES DE CONCRETO ARMADO REFORÇADOS COM CHUMBADORES E CONCRETO AUTO ADENSÁVEL O reforço de pilares de concreto armado por encamisamento é uma das técnicas de reabilitação estrutural mais utilizada no Brasil. Para que este tipo de intervenção funcione, é preciso entre outras coisas evitar o desplacamento entre o concreto adicionado (material do reforço) e o concreto antigo (substrato) quando a peça reabilitada é colocada novamente em serviço. Neste trabalho são descritos os resultados dos ensaios de oito pilares de concreto armado, submetidos à flexo-compressão reta, com o intuito de avaliar a eficiência do uso de chumbadores metálicos cruzando a interface de ligação entre os concretos moldados em idades distintas, para evitar o desplacamento entre estes materiais. Dos oito pilares ensaiados, dois eram referências e foram denominados de PO (pilar original) e PR. (pilar referência). Os outros seis foram reforçados acrescentando-se uma camada de concreto auto-adensável de 35 mm à face comprimida. O pilar PO, tinha seção transversal de 120 x 250 mm, e forneceu informações sobre o comportamento da peça antes da execução do reforço. O pilar PR tinha seção transversal de 155 x 250 mm, e forneceu informações sobre o comportamento de uma peça monolitica de seção idêntica a dos pilares após o reforço. Para executar a intervenção, inicialmente escarificou-se, por hidrojateamento, a zona de interface a ser formada pelo contato entre o concreto do reforço e do substrato. Posteriormente, fizeram-se furos ao longo desta superfície, onde foram inseridos os chumbadores mecânicos responsáveis por aumentar a aderência entre os concretos. A diferença entre os seis pilares reforçados consistia justamente na variação da posição e da quantidade dos chumbadores usados em cada peça. Os resultados obtidos indicaram que a quantidade e a posição destes chumbadores interferiram significativamente na capacidade portante dos pilares reforçados, pois retardavam a ocorrência de uma ruptura prematura por desplacamento entre os concretos do reforço e do substrato. O reforço utilizado aumentou aproximadamente três vezes a carga de ruptura do pilar original, indicando o bom desempenho do reforço.

Page generated in 0.0593 seconds