1 |
X-ray scattering in giant magneto-resistive multilayersFulthorpe, Brian David January 1999 (has links)
The scattering mechanisms responsible for Giant Magneto-Resistance (OMR) in magnetic multilayers are believed to be related to many aspects of the multilayer structure. X-ray scattering techniques provide a powerful method with which to study the bulk and interface morphology in these systems, and are therefore crucial in developing an understanding of the dominant factors influencing the magnitude of the OMR. Reflectivity measurements performed on a series of Co/Cu multilayers, sputter deposited onto etched silicon, reveal no variation in the interface roughness with etching voltage, the thickness of the individual layers also remaining constant. The observed decrease in the OMR cannot, therefore, be attributed to variations in spacer thickness or interfacial spin-independent scattering. Electron and X-ray Diffraction measurements suggest the reduction in GMR is due to a loss of antiferromagnetic coupling associated with a transformation of the texture from a randomly oriented to well oriented (111) polycrystalline texture, and subsequent reduction in the volume fraction of (100) oriented grains. Interfaces within Co/Cu are found to propagate with a high degree of conformality with increasing bilayer number, with an out-of-plane correlation length well in excess of 300Å. In contrast, the Co/Pt system exhibits a limiting out-of-plane correlation length of the order of 350Å arising from a columnar growth mode. X-ray Reflectivity and Diffraction measurements provide no structural interpretation for the 3-fold enhancement in the rate of increase of the saturation conductivity, as a function of spacer thickness, in Fe/Au (100) compared to Fe/Au (111), or why large oscillations in the GMR occur for the (100) orientation only. Such observations are, however, consistent with the existence of a channelling mechanism in Fe/Au (100). Grazing Incidence Fluorescence data indicates that Nb acts as a surfactant in Fe/Au (111) growth on sapphire. The influence of different defect types within multilayers has also been observed.
|
2 |
Validacao de metodos para as tecnicas de WDXRF e OES-SPARK na analise de acos. Calculo de incerteza de medicao para amostras de process, aco classe API / Validation of methods for WDXRF and OES-SPARK techniques in steel analysis. Determination of the uncertainty of measurements for API steel plant sampleSILVA, CARLOS E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:32Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
3 |
Validacao de metodos para as tecnicas de WDXRF e OES-SPARK na analise de acos. Calculo de incerteza de medicao para amostras de process, aco classe API / Validation of methods for WDXRF and OES-SPARK techniques in steel analysis. Determination of the uncertainty of measurements for API steel plant sampleSILVA, CARLOS E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:32Z (GMT). No. of bitstreams: 0 / Em conseqüência do aumento da demanda de gás e petróleo no mercado nacional e internacional, as especificações e certificações dos resultados de analises químicas de tubos para gasodutos e oleodutos têm se tornados cada vez mais exigentes. Um contínuo desenvolvimento tem sido realizado para a melhoria de aços microligados da classe API (American Petroleum Institute). As propriedades do aço dependem do controle da composição química e parâmetros de processo durante sua fabricação. Neste trabalho, foi realizada comparação das incertezas de medição entre as técnicas de espectrometria de fluorescência de raios X por comprimento de onda (WDXRF) e de emissão óptica com fonte de arco voltaico (OES-spark) nas análises de acompanhamento de processo na produção de aços classe API. Usualmente, este tipo de análise requer menos de 40 segundos para completa caracterização química para ajuste nos parâmetros de processo de produção. As principais fontes de influência nas análises químicas foram avaliadas por planejamento de experimentos. Os elementos constituintes e traço como Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo e Sn foram determinados utilizando as metodologias normalizadas pela ASTM E-322, E-415, E-1009 e E-1085. Os materiais de referência certificados 185A e 187A da CMI (Czech Metrology Institute) foram utilizados para avaliação dos métodos. As incertezas das medições de resultados e a validação com relação a repetitividade e reprodutibilidade das medições foram obtidas conforme os testes estatísticos, recomendados pela norma ISO/IEC 17025. A incerteza de medição para cada elemento é discutida para ambas as técnicas. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
4 |
Desenvolvimento de sistemas catalíticos não suportados para células a combustível de membrana polimérica de temperatura elevada de operação / Development of unsupported catalytic systems for high temperature polymeric fuel cell applicationsDOUBEK, GUSTAVO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:52Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
5 |
Desenvolvimento de sistemas catalíticos não suportados para células a combustível de membrana polimérica de temperatura elevada de operação / Development of unsupported catalytic systems for high temperature polymeric fuel cell applicationsDOUBEK, GUSTAVO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:52Z (GMT). No. of bitstreams: 0 / Células a combustível de membrana polimérica têm cada vez mais se destacado como meio na obtenção de energia, pela sua alta eficiência e potencial para fazê-la de modo sustentável. Entretanto muitos ainda são os desafios para consolidá-la comercialmente. Dentre eles, a aglomeração e a perda de área ativa em catalisadores suportados em carbono recebem um destaque especial, principalmente em células PEM de temperatura elevada de operação. Eletrocatalisadores não suportados, baseados em nanoarquiteturas de geometria controlada, têm se tornado uma tendência em diversas frentes de pesquisa. Tal fato se deve à alta eficiência e estabilidade atingidas por sistemas nanométricos organizados, além da possibilidade em se criar superfícies funcionais adaptadas a reações específicas. O trabalho de pesquisa buscou o desenvolvimento de sistemas catalíticos não suportados, de alta área superficial, como alternativa a eletrocatalisadores nanoparticulados suportados em carbono, a fim de se reduzir a perda sobre a área ativa quando submetidos às condições de operação em células a combustível. O trabalho explorou dois conceitos, a confecção de nanotubos de platina e a confecção de nanofios nanoporosos à base de platina vítrea. Para este desenvolvimento foram estudados e caracterizados os efeitos da dissolução seletiva, em escala nanométrica, acoplados à conformabilidade de metais amorfos e à utilização da troca galvânica como ferramenta de síntese de superfícies. Tais estudos foram utilizados como base para o projeto de sistemas catalíticos não suportados. Os materiais propostos foram avaliados quanto a sua atividade e estabilidade frente a reações comuns em células a combustível. Tais sistemas demonstraram uma alta estabilidade em relação à sua área ativa, em ensaios de durabilidade, assim como uma alta utilização do metal nobre, tornando-os promissores para a tecnologia de células a combustível. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
6 |
Desenvolvimento e aplicação de um simulador pediátrico craniano para dosimetria em tomografia computadorizada / Development and application of a pediatric head phantom for dosimetry in computed tomographyMARTINS, ELAINE W. 26 August 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-08-26T10:42:03Z
No. of bitstreams: 0 / Made available in DSpace on 2016-08-26T10:42:03Z (GMT). No. of bitstreams: 0 / Para avaliar os níveis de exposição e a dose absorvida em pacientes submetidos a exames de tomografia computadorizada, TC, é necessário calcular os índices de dose em medições com um simulador de PMMA, ou cheio de água. O simulador deve ser capaz de reproduzir as características de absorção e espalhamento do corpo ou parte do corpo humano em um campo de radiação. As grandezas específicas em TC: índice de kerma livre no ar (Ca,100), índice de kerma no ar ponderado (CW), índice de kerma no volume total (Cvol) e produto kerma no ar-comprimento (PKL) devem ser determinadas e comparadas com os níveis de referência já existentes na literatura. Neste trabalho foi desenvolvido um simulador pediátrico craniano, já que no Brasil os níveis de referência para diagnósticos (NRDs) disponíveis foram determinados baseados em um simulador padrão adulto. O simulador desenvolvido inovou em sua construção apresentando materiais que simulam a calota craniana em osso cortical (alumínio) e osso esponjoso (PVC). O seu interior foi preenchido com água destilada. As dimensões foram escolhidas de acordo com as recomendações da Organização Mundial da Saúde e do International Commission on Radiation Units, para o tamanho da cabeça de uma criança de 0 a 5 anos: 160 mm de diâmetro e 155 mm de altura. A calota craniana tem uma espessura de 4 mm e diâmetro interno de 111,9 mm. Para avaliar seu comportamento foram realizados testes em laboratórios e em feixes clínicos. Os resultados apresentaram uma atenuação de até 23% na utilização dos materiais que simulam a calota craniana evidenciando que os valores adotados para os cálculos de NRD podem estar superestimando a dose recebida por pacientes pediátricos. Percebe-se que a dose recebida em exames de crânio apresenta uma distribuição diferente por ser parcialmente atenuada e/ou retroespalhada pela calota craniana, o que não é considerado ao se utilizar o simulador constituído apenas de PMMA. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0324 seconds