• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contribuição à caracterização nanoestrutural por saxs de sonogéis de sílica obtidos por processo sol-gel /

Vollet, Dimas Roberto. January 2005 (has links)
Resumo: As características estruturais de sonogéis obtidos a partir da hidrólise ácida do TEOS estimulada por ultrasom foram estudadas por espalhamento de raios-x a baixo ângulo (SAXS). O estudo inclui: i) o processo de agregação em diferentes temperaturas; ii) o envelhecimento dos géis úmidos na fase líquida de preparação e depois da troca da fase líquida por álcool e acetona; iii) a secagem dos géis; iv) a estrutural evolução de xerogéis e aerogéis com o tratamento térmico até 1100 oC; e v) um estudo comparativo usando SAXS e adsorção de nitrogênio na caracterização de aerogéis e xerogéis... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The structural characteristics of acid-catalyzed and ultrasound stimulated TEOS-derived sonogels were studied by small-angle x-ray scattering (SAXS). The study includes: i) the aggregation process at different temperatures; ii) the ageing of the wet gels in the liquid phase as prepared and after exchanging the liquid phase by alcohol and acetone; iii) the drying of the gels; iv) the structural evolution of xerogels and aerogels under heat treatment up to 1100 oC; and v) a comparative study using SAXS and nitrogen adsorption in the characterization of aerogels and xerogels... (Complete abstract, click electronic access below)
2

Avaliação comparativa de diferentes meios para o diagnóstico em endodontia /

Borges, Marco Aurélio Gagliardi. January 2002 (has links)
Resumo: O objetivo deste trabalho foi avaliar comparativamente três meios de diagnóstico em endodontia utilizando a radiografia convencional, radiografia digital indireta e a tomografia computadorizada helicoidal. Para tanto foram selecionados 20 casos clínicos onde já haviam realizado os exames radiográficos, tomográficos e exame macroscópico para a comprovação clínica. Foram selecionados três examinadores para a avaliação das radiografias convencionais e digitais com a finalidade de elaborarem um diagnóstico clínico. Após essa elaboração o diagnóstico somado ao diagnóstico tomográfico estes foi confrontado com o macroscópico para a comparação. A conclusão obtida foi em ordem decrescente, tomografia computadorizada helicoidal, radiografia digital e por último a radiografia convencional. / Abstract: The objective of this work was to evaluate comparativily three ways of diagnosis in endodontia using the conventional x-ray, indirect digital x-ray and the computerized cat scan helical. For 20 cases had been in such a way selected clinical where already they had carried through the radiográficos, tomographic examinations and macrocospic examination for the clinical evidence. Three examiners for the evaluation of the conventional and digital x-rays with the purpose had been selected to elaborate a clinical diagnosis. After this elaboration the diagnosis added to the tomographic diagnosis these was collated with the macrocospic one for the matching. The gotten conclusion was orderly decreasing, computerized cat scan helical, digital x-ray and finally the conventional x-ray. / Orientador: Renato de Toledo Leonardo / Coorientador: Idomeo Bonetti Filho / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Celso Kenji Nishiyama / Mestre
3

Implementação de um sistema detector piroelétrico para medição de intensidade de radiação X na faixa de ortovoltagem /

Pontes, Wesley. January 2006 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Walter Katsumi Sakamoto / Banca: Adelaide de Almeida / Resumo: Neste trabalho descreve-se um sistema detector piroelétrico de intensidade (taxa de fluência de energia) de raios X, para a faixa de ortovoltagem (80 a 300 kVp), constituído essencialmente por uma câmara piroelétrica, um circuito microcontrolado e um display de cristal líquido. A radiação foi produzida por um equipamento de ortovoltagem Siemens Stabilipan II. A câmara possui no seu interior um sensor piroelétrico e um conversor correntetensão de alta sensibilidade, que tem como principal componente um amplificador operacional OPA111 (Burr-Brown). Utilizou-se um osciloscópio digital e um circuito microcontrolado associado ao display para a medição da amplitude dos pulsos de sinal elétrico decorrentes dos pulsos de raios X incidentes no sensor. A resposta do sistema detector piroelétrico foi linear com a intensidade da radiação, em uma faixa de sua resposta, com alguns dos materiais utilizados. O sensor PZT Fe (zirconato titanato de chumbo com ferro) apresentou a melhor sensibilidade para uma grande faixa de tensão sendo assim o mais adequado para utilização em medições de intensidade de radiação X. Dos resultados obtidos, a precisão, resolução e sensibilidade do sistema detector, com os diferentes sensores piroelétricos, associados ao seu baixo custo, construção relativamente simples e facilidade de realização das medições, podem torná-lo muito útil no monitoramento de radiação produzida por equipamentos de ortovoltagem. / Abstract: In this work a pyroeletric detector system is described for measuring the energy fluence rate (intensity) of x-ray pulses in the ortovoltage range (from 80 to 300 kVp), consisting of a pyroeletric chamber, a microcontrolled circuit, and a liquid crystal display (LCD). The radiation was produced by an ortovoltage equipment Siemens Stabilipan II. The pyroeletric chamber consists essentially of a pyroeletric detector and a current-to-voltage converter that has an operational amplifier OPA 111 (Burr-Brown) as the main component. The electrical pulses produced by the radiation was measured with an oscilloscope and a microcontrolled circuit associated to a LCD. The pyroelectric detector response to a radiation pulse showed linear relationship between the peak electric signal produced by the detector and the intensity of the x-ray pulses in some materials used. The PZT fe showed the most sensibility for a bigger voltage range being thus the most adjusted for measuring the intensity of radiation X. The precision, resolution, and sensibilities of the pyroelectric detector system, with the different pyroeletric sensors, associated with his low cost, relatively simple construction, and easiness for using the device, can turn it very useful for measuring the intensity of radiation produced by ortovoltage equipments. / Mestre
4

Selênio em tilápia do Nilo utilizando eletroforese em gel e espectrometria atômica /

Silva, Fábio Arlindo. January 2009 (has links)
Resumo: O presente trabalho teve como objetivo investigar a presença de selênio em spots protéicos de amostras de plasma, músculo e fígado de tilápia do Nilo (Oreochromis niloticus) obtidos após separação das proteínas por eletroforese em gel de poliacrilamida em segunda dimensão (2D-PAGE) e posterior avaliação qualitativa por fluorescência de raios-X com radiação síncrotron (SR-XRF). A análise dos espectros de fluorescência obtidos indicaram a presença de selênio em oito proteínas do plasma, seis proteínas do músculo e cinco proteínas do fígado. Observou-se que o selênio está distribuído em sua maioria em proteínas com massa molar menor que 50 kDa. Proteínas acima de 50 kDa foram encontradas somente no plasma. / Abstract: An investigation was made into selenium in protein spots of samples of plasma, muscle and liver of Nile tilapia (Oreochromis niloticus) obtained after protein separation by two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) and subsequent qualitative evaluation by synchrotron radiation X-ray fluorescence (SR-XRF). An analysis of the fluorescence spectra indicated the presence of selenium in eight plasma proteins, six muscle proteins, and five liver proteins. Selenium was found to be distributed mainly in proteins with a molar mass smaller than 50 kDa. Proteins with a molar mass higher than 50 kDa was found only in the plasma. / Orientador: Pedro de Magalhães Padilha / Coorientador: Marco Aurélio Zezzi Arruda / Banca: Paulo Roberto Rdrigues Ramos / Banca: Ricardo de Oliveira Orsi / Banca: Gustavo Rocha de castro / Banca: Paulo dos Santos Roldan / Doutor
5

Implementação de um sistema eletrônico para medir taxa de fluência de energia de radiação na faixa de radioterapia com sensor piroelétrico /

Pontes, Wesley. January 2011 (has links)
Orientador: Aparecido Augusto de Carvalho / Banca: Cláudio Kitano / Banca: Walter Katsumi Sakamoto / Banca: Tony Inácio da Silva / Banca: Giuliano Pierre Estevam / Resumo: Sensores piroelétricos podem ser utilizados para medir a taxa de fluência de energia (intensidade) da radiação X na faixa de diagnóstico médico e de ortovoltagem. Neste trabalho, foi implementado um sistema eletrônico que pode medir taxa de fluência de energia de radiação gama de 1,25 MeV e fótons X de 6 MV e 15 MV. O sistema é constituído por um sensor piroelétrico, um conversor corrente-tensão de alta sensibilidade e um instrumento para registrar a forma de onda e medir o pulso do sinal produzido pelo sensor. Este instrumento pode ser um osciloscópio, um circuito microcontrolado associado a um display de cristal líquido, ou um módulo de aquisição de dados e um laptop. O sensor piroelétrico e o conversor corrente-tensão foram alojados em uma câmara piroelétrica blindada. Seis tipos de sensores piroelétricos foram avaliados, sendo três cerâmicas e três compósitos. Os resultados obtidos com o sistema eletrônico, utilizando os diferentes tipos de sensores, possibilitaram caracterizá-lo em termos de precisão, resolução e sensibilidade. O sistema apresentou resposta linear com a taxa de fluência de energia da radiação, precisão melhor que 3 % e resolução de 5,56 nW/m2. As constantes piezoelétricas d33 dos sensores utilizados não sofreram alteração após os mesmos terem sido irradiados com 45 Gy de radiação na faixa de radioterapia. Estas características, associadas à importância de se medir a taxa de fluência de energia de radiação ionizante, podem tornar o instrumento piroelétrico muito útil no monitoramento de radiação produzida por equipamentos de radioterapia / Abstract: Pyroelectric sensors have been be used to measure the energy fluence rate (intensity) of x-radiation in the range of medical diagnosis and orthovoltage. In this work, we implemented an electronic system that can measure the energy fluence rate of 1.25 MeV gamma radiation, 6 MV and 15 MV X-photons. The system consists of a pyroelectric sensor, a high sensitivity current-to-voltage converter and an instrument for measuring and recording the waveform of pulses produced by the pyroelectric sensor. This instrument may be an oscilloscope, a microcontrolled circuit associated with a liquid crystal display, or a data acquisition module connected to a laptop. The pyroelectric sensor and the current-tovoltage converter were placed in an shielded pyroelectric camera. Six types of pyroelectric sensors were evaluated, three ceramics and three composites. The results obtained with the electronic system, using different types of sensors, allowed us to characterize it in terms of precision, resolution and sensitivity. The system has linear response to the energy fluence rate of radiation, precision better than 3 % and resolution of 5,6 nW/m2. The piezoelectric constant d33 of the sensors used have not changed after these have been irradiated with 45 Gy of radiotherapy radiation. These characteristics, associated with the importance of measuring the ionizing radiation energy fluence rate may make the pyroelectric instrument very useful in monitoring radiation produced by radiotherapy equipments / Doutor

Page generated in 0.0334 seconds