Spelling suggestions: "subject:"zugdehnung"" "subject:"ausdehnung""
1 |
Microstructure and mechanical properties of new composite structured Ti-based alloysOkulov, Ilya 09 March 2015 (has links) (PDF)
The demanding structural applications (e.g. aerospace, biomedical, etc.) require new materials with improved mechanical performance. The novel Ti-based dendrite + nano-/ultrafine-structured (Ti-based DNUS) composites exhibit an advantageous combination of high compressive strength (2000 – 2500 MPa) and large compressive ductility (10 – 30 %) already in the as-cast state [1,2] and, therefore, can be referred as high-performance materials. However, these Ti-based composites frequently exhibit very low or even lack of tensile ductility [3].
Therefore, the aim of this research work is to develop high strength Ti-based DNUS composites with pronounced tensile plasticity and to correlate the mechanical properties with their microstructure.
In order to reach the goal, the high-strength Ti66Nb13Cu8Ni6.8Al6.2 (at.%) alloy exhibiting large compressive ductility [4] was selected for the modification. The microstructure of Ti66Nb13Cu8Ni6.8Al6.2 is composed of two metallographic constituents including β-Ti dendrites and an interdendritic component. The β-Ti dendrites are enriched in Nb and, therefore, Nb is referred as “dendritic element” whereas the interdendritic component is enriched in Ni and Cu and, therefore, these are referred as “interdendritic elements”.
To perform a systematic study of the “interdendritic elements” (Ni, Cu and Co) effect on microstructure, a number of alloys with different concentration and types of alloying elements (Ti-Nb-Cu-Ni-Al, Ti-Nb-Co-Ni-Al, Ti-Nb-Cu-Co-Al and Ti-Nb-Ni(Co)-Al) were developed. It was shown that a higher concentration of the “interdendritic elements” in a composition within one alloy system corresponds to a higher volume fraction of the interdendritic component. Additionally, the crystal structure of the interdendritic phases is affected by type of the “interdendritic elements”.
Since the most advanced applications (e.g. aerospace) require materials with high specific strengths, the new ductile Ti-Nb-Cu-Ni-Al alloys were modified to reduce their density, i.e. the Nb was substituted by lighter V. As a result, a new family of Ti-V-Cu-Ni-Al alloys with improved specific strength compared to the Ti-Nb-Cu-Ni-Al alloys was developed. Additionally, moduli of resilience of the Ti-V-Ni-Cu-Al alloys are superior when compared with those of the commercial Ti-based spring materials.
The effect of microstructure on deformation of the newly developed alloys was studied through the in-situ microstructural analysis of samples at different strained states by means of scanning electron microscopy. To reveal the effect of the metallographic constituents on strength, the microhardness mapping of the new alloys was performed.
Using the obtained empirical principles of microstructure adjustment, a new Ti68.8Nb13.6Co6Cu5.1Al6.5 (at.%) alloy with a large static toughness (superior to those of the recently developed Ti-based metallic glass composites) was developed. This large static toughness is due to both high strength and significant tensile plasticity. To study the effect of microstructure on tensile plasticity of Ti68.8Nb13.6Co6Cu5.1Al6.5 the in-situ microstructural analysis of samples at different strained states in the scanning electron microscope as well as the transmission electron microscopy studies were performed. / Der erhöhte Anspruch an strukturelle Anwendungen (z.B. Luftfahrt, Biomedizin, etc.) verlangt neue Werkstoffe mit verbesserten mechanischen Leistungsfähigkeiten. Neuartige Ti-basierte dendritische nano-/ultrafeine Komposite (Ti-basierte DNUS Komposite) besitzen eine vorteilhafte Kombination von hoher Druckfestigkeit mit großer plastischer Verformbarkeit unter Druckbelastung bereits im Gusszustand [1,2] wodurch sie als hochleistungsfähige Werkstoffe angesehen werden. Jedoch besitzen diese Ti-basierte DNUS Komposite heufig eine stark verringerte oder gar keine Duktilität unter Zugbelastung [3].
Deswegen ist es das Ziel dieser Forschungsarbeit neue hochfeste Ti-basierte DNUS Komposite mit ausgeprägter Duktilität unter Zugbelastung zu entwickeln und die mechanischen Eingeschaften mit ihrer Mikrostruktur zu korrelieren.
Um dieses Ziel zu erreichen wurde die hochfeste Legierung Ti66Nb13Cu8Ni6.8Al6.2 (at.%) [4], die eine große plastische Verformbarkeit unter Druckbelastung aufweist, ausgewählt. Die Mikrostruktur von Ti66Nb13Cu8Ni6.8Al6.2 setzt sich aus zwei metallographischen Konstituenten, einschließlich β-Ti Dendriten und einer interdendritischen Komponente, zusammen. Die β-Ti Dendriten sind mit Nb angereichert, weswegen Nb als “dendritisches Element” bezeichnet wird, wohingegen die interdendritische Komponente mit Ni und Cu angereichert ist und deswegen diese als “interdendritische Elemente” bezeichnet werden.
Um den Einfluss der “interdendritischen Elemente” (Ni, Cu and Co) auf die Mikrostruktur zu untersuchen wurden Legierungen mit verschiedenen Konzentrationen unterschiedlicher Legierungselemente (Ti-Nb-Cu-Ni-Al, Ti-Nb-Co-Ni-Al, Ti-Nb-Cu-Co-Al and Ti-Nb-Ni(Co)-Al) entwickelt. Es wurde gezeigt, dass eine höhere Konzentration “interdendritischer Elemente” in einer bestimmten Zusammensetzung einem höheren Volumanteil der interdendritischen Komponente entspricht. Zusätzlich wird die Kristallstruktur der interdendritischen Phase sehr stark durch die “interdendritischen Elemente” beeinflusst. Da die meisten hoch entwickelten Anwendungen (z.B. Luftfahrt) gesteigerte spezifische Festigkeiten erforden, wurden die neuen duktilen Ti-Nb-Cu-Ni-Al Legierungen modifiziert um ihre Dichte zu reduzieren, indem Nb durch das leichtere V ersetzt wurde. Als Ergebniss wurde eine neue Familie von Ti-V-Cu-Ni-Al Legierungen, mit im Vergleich zu Ti-Nb-Cu-Ni-Al Legierungen verbesserten spezifischen Festigkeiten, entwickelt. Zusäzlich ist die elastische Formänderungsenergiedichte der neu entwickelten Legierungen höher verglichen mit kommerziellen Ti-basierten Federmaterialien.
Der Effekt der Mikrostruktur auf das Verformungsverhalten der Legierungen wurde mittels in-situ mikrostruktureller Analysen verschiedener Verformungszustände im Rasterelektronenmikroskop untersucht. Um ein Einfluss der metallographischen Konstituenten auf die Festigkeit zu bestimmen wurden Mikrohärtekarten erstellt.
Unter Verwendung der erhalten empirischen Prinzipen zur Einstellung der Mikrostruktur wurde eine neue Legierung Ti68.8Nb13.6Co6Cu5.1Al6.5 (at.%) mit hoher statischer Zähigkeit (besser als die der kürzlich entwickelten Ti-basierten gläsernen metallischen Kompositlegierungen) entwickelt. Diese hohe statische Zähigkeit wird sowohl durch die hohe Festigkeit als auch durch die ausgeprägte Plastizität unter Zugbelastung verursacht. Um den Einfluss der Mikrostruktur auf die Plastizität unter Zug zu untersuchen wurde Transmissionelektronmikroskopie sowie in-situ mikrostrukturelle Analysen verschiedener Verformungszustände im Rasterelektronmikroskop durchgefühlt.
|
2 |
Microstructure and mechanical properties of new composite structured Ti-based alloysOkulov, Ilya 05 February 2015 (has links)
The demanding structural applications (e.g. aerospace, biomedical, etc.) require new materials with improved mechanical performance. The novel Ti-based dendrite + nano-/ultrafine-structured (Ti-based DNUS) composites exhibit an advantageous combination of high compressive strength (2000 – 2500 MPa) and large compressive ductility (10 – 30 %) already in the as-cast state [1,2] and, therefore, can be referred as high-performance materials. However, these Ti-based composites frequently exhibit very low or even lack of tensile ductility [3].
Therefore, the aim of this research work is to develop high strength Ti-based DNUS composites with pronounced tensile plasticity and to correlate the mechanical properties with their microstructure.
In order to reach the goal, the high-strength Ti66Nb13Cu8Ni6.8Al6.2 (at.%) alloy exhibiting large compressive ductility [4] was selected for the modification. The microstructure of Ti66Nb13Cu8Ni6.8Al6.2 is composed of two metallographic constituents including β-Ti dendrites and an interdendritic component. The β-Ti dendrites are enriched in Nb and, therefore, Nb is referred as “dendritic element” whereas the interdendritic component is enriched in Ni and Cu and, therefore, these are referred as “interdendritic elements”.
To perform a systematic study of the “interdendritic elements” (Ni, Cu and Co) effect on microstructure, a number of alloys with different concentration and types of alloying elements (Ti-Nb-Cu-Ni-Al, Ti-Nb-Co-Ni-Al, Ti-Nb-Cu-Co-Al and Ti-Nb-Ni(Co)-Al) were developed. It was shown that a higher concentration of the “interdendritic elements” in a composition within one alloy system corresponds to a higher volume fraction of the interdendritic component. Additionally, the crystal structure of the interdendritic phases is affected by type of the “interdendritic elements”.
Since the most advanced applications (e.g. aerospace) require materials with high specific strengths, the new ductile Ti-Nb-Cu-Ni-Al alloys were modified to reduce their density, i.e. the Nb was substituted by lighter V. As a result, a new family of Ti-V-Cu-Ni-Al alloys with improved specific strength compared to the Ti-Nb-Cu-Ni-Al alloys was developed. Additionally, moduli of resilience of the Ti-V-Ni-Cu-Al alloys are superior when compared with those of the commercial Ti-based spring materials.
The effect of microstructure on deformation of the newly developed alloys was studied through the in-situ microstructural analysis of samples at different strained states by means of scanning electron microscopy. To reveal the effect of the metallographic constituents on strength, the microhardness mapping of the new alloys was performed.
Using the obtained empirical principles of microstructure adjustment, a new Ti68.8Nb13.6Co6Cu5.1Al6.5 (at.%) alloy with a large static toughness (superior to those of the recently developed Ti-based metallic glass composites) was developed. This large static toughness is due to both high strength and significant tensile plasticity. To study the effect of microstructure on tensile plasticity of Ti68.8Nb13.6Co6Cu5.1Al6.5 the in-situ microstructural analysis of samples at different strained states in the scanning electron microscope as well as the transmission electron microscopy studies were performed. / Der erhöhte Anspruch an strukturelle Anwendungen (z.B. Luftfahrt, Biomedizin, etc.) verlangt neue Werkstoffe mit verbesserten mechanischen Leistungsfähigkeiten. Neuartige Ti-basierte dendritische nano-/ultrafeine Komposite (Ti-basierte DNUS Komposite) besitzen eine vorteilhafte Kombination von hoher Druckfestigkeit mit großer plastischer Verformbarkeit unter Druckbelastung bereits im Gusszustand [1,2] wodurch sie als hochleistungsfähige Werkstoffe angesehen werden. Jedoch besitzen diese Ti-basierte DNUS Komposite heufig eine stark verringerte oder gar keine Duktilität unter Zugbelastung [3].
Deswegen ist es das Ziel dieser Forschungsarbeit neue hochfeste Ti-basierte DNUS Komposite mit ausgeprägter Duktilität unter Zugbelastung zu entwickeln und die mechanischen Eingeschaften mit ihrer Mikrostruktur zu korrelieren.
Um dieses Ziel zu erreichen wurde die hochfeste Legierung Ti66Nb13Cu8Ni6.8Al6.2 (at.%) [4], die eine große plastische Verformbarkeit unter Druckbelastung aufweist, ausgewählt. Die Mikrostruktur von Ti66Nb13Cu8Ni6.8Al6.2 setzt sich aus zwei metallographischen Konstituenten, einschließlich β-Ti Dendriten und einer interdendritischen Komponente, zusammen. Die β-Ti Dendriten sind mit Nb angereichert, weswegen Nb als “dendritisches Element” bezeichnet wird, wohingegen die interdendritische Komponente mit Ni und Cu angereichert ist und deswegen diese als “interdendritische Elemente” bezeichnet werden.
Um den Einfluss der “interdendritischen Elemente” (Ni, Cu and Co) auf die Mikrostruktur zu untersuchen wurden Legierungen mit verschiedenen Konzentrationen unterschiedlicher Legierungselemente (Ti-Nb-Cu-Ni-Al, Ti-Nb-Co-Ni-Al, Ti-Nb-Cu-Co-Al and Ti-Nb-Ni(Co)-Al) entwickelt. Es wurde gezeigt, dass eine höhere Konzentration “interdendritischer Elemente” in einer bestimmten Zusammensetzung einem höheren Volumanteil der interdendritischen Komponente entspricht. Zusätzlich wird die Kristallstruktur der interdendritischen Phase sehr stark durch die “interdendritischen Elemente” beeinflusst. Da die meisten hoch entwickelten Anwendungen (z.B. Luftfahrt) gesteigerte spezifische Festigkeiten erforden, wurden die neuen duktilen Ti-Nb-Cu-Ni-Al Legierungen modifiziert um ihre Dichte zu reduzieren, indem Nb durch das leichtere V ersetzt wurde. Als Ergebniss wurde eine neue Familie von Ti-V-Cu-Ni-Al Legierungen, mit im Vergleich zu Ti-Nb-Cu-Ni-Al Legierungen verbesserten spezifischen Festigkeiten, entwickelt. Zusäzlich ist die elastische Formänderungsenergiedichte der neu entwickelten Legierungen höher verglichen mit kommerziellen Ti-basierten Federmaterialien.
Der Effekt der Mikrostruktur auf das Verformungsverhalten der Legierungen wurde mittels in-situ mikrostruktureller Analysen verschiedener Verformungszustände im Rasterelektronenmikroskop untersucht. Um ein Einfluss der metallographischen Konstituenten auf die Festigkeit zu bestimmen wurden Mikrohärtekarten erstellt.
Unter Verwendung der erhalten empirischen Prinzipen zur Einstellung der Mikrostruktur wurde eine neue Legierung Ti68.8Nb13.6Co6Cu5.1Al6.5 (at.%) mit hoher statischer Zähigkeit (besser als die der kürzlich entwickelten Ti-basierten gläsernen metallischen Kompositlegierungen) entwickelt. Diese hohe statische Zähigkeit wird sowohl durch die hohe Festigkeit als auch durch die ausgeprägte Plastizität unter Zugbelastung verursacht. Um den Einfluss der Mikrostruktur auf die Plastizität unter Zug zu untersuchen wurde Transmissionelektronmikroskopie sowie in-situ mikrostrukturelle Analysen verschiedener Verformungszustände im Rasterelektronmikroskop durchgefühlt.
|
Page generated in 0.0234 seconds