• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 161
  • 37
  • 10
  • 10
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 578
  • 373
  • 306
  • 287
  • 265
  • 250
  • 63
  • 57
  • 46
  • 42
  • 39
  • 29
  • 25
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

The development of a new measure of linear accelerator throughput in radiation oncology treatment delivery : the basic treatment equivalent (B.T.E.) /

Delaney, G. P. January 2001 (has links)
Thesis (M.D.)--University of New South Wales, 2001. / Also available online.
42

Accelerator systems and instrumentation for the NuMI neutrino beam

Zwaska, Robert Miles, January 1900 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2005. / Vita. Includes bibliographical references.
43

Frequency Domain Holography of laser wakefields

Matlis, Nicholas Hill, January 1900 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2006. / Vita. Includes bibliographical references.
44

A Multiloop Control System for Tandem Electrostatic Accelerators

Cairns, John Everett 05 1900 (has links)
<p> The limitations of the conventional control system due to the corona discharge are discussed. An improved system employing a parallel feedback loop to modulate the terminal stripper is described. Finally an experiment is described whereby the performance of this system is measured and compared with the original system performance.</p> / Thesis / Master of Science (MSc)
45

The imaging performance of multiwire proportional chambers

Gordon, John Stuart January 1985 (has links)
A simplified description is given of the operation of a multiwire proportional chamber (MWPC) in the soft X-ray imaging application. Expressions are developed to allow the calculation of the distribution of induced charge on the cathodes of an MWPC. With extensions to permit direct comparison, the calculations are subjected to detailed experimental verification. A generalised, approximate formulation of the distribution with one independent parameter is described. The prediction of cathode system position response using the theoretical distributions is demonstrated. The available MWPC position readout methods are reviewed, and where possible their differential non-linearity is measured experimentally. A new position-sensitive cathode of good linearity and spatial resolution is presented. The effect of the wires of an MWPC on its imaging performance is briefly considered. An attempt is made to assess the contribution to MWPC spatial resolution of the range of the electrons produced initially by an X-ray absorption event in argon-methane mixtures. In conclusion, the important causes of MWPC imaging imperfection are noted and classified.
46

Some nuclear physics aspects of the r-process nucleosynthesis

Goriely, Stephane January 1991 (has links)
No description available.
47

High power microwave window failures

Rimmer, R. A. January 1988 (has links)
No description available.
48

Polarization of the ground state neutrons from the 7Li(d,n)8Be reaction

Ghazarian, Ara M. January 1982 (has links)
No description available.
49

A measurement of the two gamma decays of neutral K-mesons

Shipsey, Ian Peter Joseph January 1986 (has links)
No description available.
50

The scattering of 3MeV neutrons from heavy nuclei

Annand, John R. M. January 1982 (has links)
No description available.

Page generated in 0.0681 seconds