451

Implantacao de um servico de radioterapia com acelerador linear (fotons): testes de aceitacao, dosimetria e controle de qualidade

BERDAKY, MAFALDA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:41Z (GMT). No. of bitstreams: 1 07002.pdf: 4288573 bytes, checksum: c18927c21f315b4f8c58d377e6d345ca (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
452

Estudo de viabilidade técnica e econômica para implementação de uma unidade móvel para tratamento de efluentes industriais com feixe de elétrons

RELA, CAROLINA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:47Z (GMT). No. of bitstreams: 0 / O tratamento de efluentes industriais é uma prática que vem se disseminando em ritmo acelerado, porque além de contribuir para reforçar a imagem pública, através do combate à poluição, ela traz vantagens econômicas para as empresas que podem reutilizar a água tratada do efluente em seus próprios processos. A técnica de tratamento estudada no presente trabalho é a que utiliza a oxidação/redução química destacando-se a utilização da radiação ionizante por meio de feixes de elétrons. Esta técnica utiliza um processo oxidativo avançado, gerando radicais altamente reativos que provocam a oxidação, redução, dissociação e degradação em compostos orgânicos e exercendo efeito letal nos microorganismos, protozoários e parasitas em geral. Neste trabalho desenvolveu-se um projeto conceituai e básico de uma unidade móvel de tratamento de efluentes utilizando radiação ionizante, fazendo com que a unidade se desloque até o ponto de tratamento, facilitando assim a logística. Em seguida, elaborou-se um estudo de viabilidade técnica e econômica permitindo dados consistentes sobre a capacidade e custo de processamento de efluentes e valores consolidados dos investimentos necessários para serem apresentados a órgãos financiadores para a construção de uma unidade móvel. Os resultados dos estudos demonstram que é viável tecnicamente a construção de uma unidade móvel, pois atende a legislação pertinente do Brasil, nos aspectos de Radioproteção e limite de transporte de carga. O custo unitário do processamento mostrou-se superior ao de uma unidade fixa em razão da diminuição da eficiência da interação da radiação incidente no efluente processado, devido à redução de energia do acelerador de elétrons e da disponibilidade de operação da unidade. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
453

Projeto e construcao de uma estrutura aceleradora de eletrons de onda continua

TAKAHASHI, JIRO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:48Z (GMT). No. of bitstreams: 1 05030.pdf: 6618082 bytes, checksum: b37bbbe1087da50e0aecf20762c5f711 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
454

Tratamento de esgoto sanitario com o uso de acelerador de eletrons

BORRELY, SUELI I. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:05Z (GMT). No. of bitstreams: 1 06048.pdf: 4286403 bytes, checksum: 125c0216eea47b9a749977ad0ec8b66a (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
455

Projeto e implementacao do sistema de controle do acelerador microtron / Project and implementation of the control system for the microtron accelerator

MALAFRONTE, ALEXANDRE A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:12Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:01Z (GMT). No. of bitstreams: 0 / O acelerador de elétrons recirculado do tipo microtron, que está sendo construído no Instituto de Física da Universidade de São Paulo, possui algumas centenas de parâmetros a serem monitorados e controlados. Estes parâmetros pertencem a vários subsistemas, tais como: transporte; vácuo; RF; e diagnóstico. Para diminuir a carga cognitiva do operador e auxiliá-lo no controle da máquina, foi construído um sistema de controle computadorizado, capaz de permear os diversos subsistemas e que permite ao operador medir e alterar os parâmetros de interesse, além de alertá-lo quando algum destes parâmetros exceder um valor pré-determinado. Este sistema de controle foi construído usando-se a metodologia do modelo das três camadas lógicas, a saber: camada dos dispositivos de entrada e saída; camada dos servidores de dispositivos; e camada da interface com o usuário. Na camada dos dispositivos de entrada e saída foram utilizados vários equipamentos, comerciais ou construídos no Laboratório do Acelerador Linear (LAL), possuindo interfaces de comunicação diversas. Na camada dos servidores de dispositivos foram utilizados PCs industriais. A camada da interface com o usuário utiliza um PC convencional executando uma interface humano-computador construída com o auxílio do software LabWindows/CVI (National Instruments). O sistema de controle deve apresentar características associadas à flexibilidade, escalabilidade e custo, para que seja passível de utilização durante todo o tempo de vida útil do acelerador e suporte manutenção pela equipe do próprio LAL. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
456

Processo de oxidacao avancada por radiacao ionizante na degradacao do herbicida ametrina em embalagens de pead descartadas / Study of herbicide ametryne degradation in HDPE packaging using the advanced oxidation process by ionizing radiation

ANDRADE, DEBORA C. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:01Z (GMT). No. of bitstreams: 0 / Este trabalho é parte do projeto cujo objetivo é a descontaminação de embalagens comerciais de polietileno de alta densidade, PEAD, usadas na agricultura. Foi estudado o herbicida ametrina (nome comercial Gesapax 500), por sua ampla aplicação no Brasil principalmente em plantações de cana e milho. A ametrina é comercializada desde 1975 e, dependendo da formulação e do tipo de aplicação, pode permanecer em água e solos por meses e anos. Para avaliar a eficiência do processo de radiação na remoção de contaminação por pesticidas, embalagens PEAD foram irradiadas usando um Acelerador de Elétrons da Radiation Dynamics com energia de 1,5 MeV e 37 kW, no sistema batelada. A ametrina foi analisada por cromatografia gasosa (GC Shimadzu 17 A), após a extração com solução de hexano/diclorometano (1:1 v/v). A curva de calibração foi obtida com um coeficiente de regressão de 0,986 e o desvio padrão relativo foi menor que 10%. A eficiência do processamento por irradiação foi avaliado pela degradação da ametrina e pelo grau de destruição (Gd). O processamento por feixe de elétrons mostrou alta eficiência em degradar moléculas de ametrina em embalagens PEAD quando as amostras foram irradiadas na presença de pequenas quantidades de água. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
457

Dosimetria aplicada na irradiacao de toda a pele utilizando feixes de eletrons com energia nominal de 4 MeV

POLI, MARIA E.R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:24Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
458

Obtencao da blenda polimerica PET/PP/PE/EVA a partir de 'garrafas PET' e estudo das modificacoes provocadas pela radiacao ionizante

ROSSINI, EDVALDO L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:13Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:38Z (GMT). No. of bitstreams: 1 11256.pdf: 8935213 bytes, checksum: f4e37ab5ffb1e214eed65095f6f82563 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
459

Estudo do efeito da radiação ionizante em compósitos de polipropileno/pó de madeira usando titanato de bário como agente de acoplagem

ULLOA, MARITZA E.P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:34Z (GMT). No. of bitstreams: 0 / Este trabalho teve por objetivo o estudo dos efeitos da radiação ionizante nas propriedades de compósitos de pó de madeira em matriz de polipropileno, utilizando o titanato de bário como agente de acoplagem e o monômero reativo diacrilato de tripropileno glicol (TPDGA). Foi utilizado como fonte de radiação o acelerador de elétrons. Foram investigadas as propriedades físicas dos compostos virgens, bem como do compósito polipropileno/pó de madeira, com e sem a adição de titanato de bário e do monômero TPDGA. Os compósitos desenvolvidos foram preparados a partir do tratamento da carga, incorporando os aditivos ao reforço pó de madeira, seguindo-se a fusão do polipropileno e a mistura dos materiais do compósito na calandra. Posteriormente foram moldados corposde- prova por injeção para serem irradiados e utilizados nos ensaios mecânicos e térmicos. Foram determinadas as propriedades mecânicas dos compostos desenvolvidos (tração, dureza, impacto e índice de fluidez), bem como as propriedades térmicas (HDT e Vicat). As composições investigadas foram polipropileno/pó de madeira, polipropileno/pó de madeira com titanato de bário, polipropileno/pó de madeira com titanato de bário e TPDGA, utilizando concentrações de 10%, 15% e 20% de pó de madeira no polipropileno. As amostras foram separadas em grupos para serem irradiadas com doses de 10kGy e 20kGy nas amostras do ensaio de tração além dessas doses foram utilizadas doses de 15kGy e 25kGy para ser observado o comportamento da amostra frente ao aumento da radiação. Estas doses foram escolhidas para mostrar que com baixas doses o material compósito apresenta reticulação, o que representa uma opção viável comercialmente. Houve uma redução do índice de fluidez para os compostos contendo pó de madeira, sendo esta redução mais efetiva na presença de TiBa. O tratamento superficial utilizando o monômero TPDGA influenciou nas amostras dos compósitos, pois este agiu como plastificante tornando as amostras mais fáceis de processar aumentando a mobilidade entre as macromoléculas, diminuindo assim a viscosidade e aumentando o índice de fluidez tanto nas amostras irradiadas como as não irradiadas. Os resultados obtidos para ensaio de resistência à tração indicam um acréscimo da propriedade, o aumento ocorreu tanto nas amostras WF/PP quanto nas amostras com TiBa e TPDGA, devido à formação de ligações cruzadas (reticulação) em decorrência da radiação. A incorporação de pó de madeira no polipropileno resultou na diminuição da resistência ao impacto. O decréscimo desta propriedade pode ter acontecido devido à presença de reforço pó de madeira que pode atuar como concentrador de tensão e como conseqüência a redução de resistência ao impacto. Houve um acréscimo na dureza dos compósitos contendo pó de madeira. O acréscimo na dureza foi significativo nos compósitos WF/PP que não foram irradiados. O acréscimo se deu principalmente nas composições de 20%WF/PP, isso porque quanto maior a quantidade de carga maior o módulo de dureza. Nas amostras irradiadas a dureza aumentou devido à oxidação da madeira frente à radiação. Observou-se que em alguns casos o aumento na dose de radiação não influenciou significativamente na variação da temperatura de deflexão térmica dos compósitos indicando que houve reticulação entre as moléculas promovido pelo TPDGA, e uma melhoria na adesão entre interfaces promovido pelo titanato. No ensaio de temperatura de amolecimento Vicat os resultados apresentados foram muito próximos ao PP puro, como os resultados não mostraram diferenças significativas, pode-se considerar a temperatura dos compósitos a mesma do PP puro. A radiação ionizante interagiu no material compósito reticulando o PP e oxidando a madeira, observando-se assim um acréscimo em algumas propriedades e o decréscimo em outras. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
460

Projeto, construção e caracterização de sistemas de referência para feixes de elétrons de aceleradores clínicos / Design, construction and characterization of reference systems for electron beams of clinical accelerators

NONATO, FERNANDA B.C. 07 January 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-01-07T16:00:13Z No. of bitstreams: 0 / Made available in DSpace on 2015-01-07T16:00:14Z (GMT). No. of bitstreams: 0 / Os aceleradores lineares vêm substituindo gradativamente os irradiadores de fontes gama nos Serviços de Radioterapia no Brasil. Consequentemente, existe a necessidade de aquisição de câmaras de ionização para uso em dosimetria dos feixes de radiação X e de elétrons dos aceleradores lineares. Entretanto, as câmaras de ionização comerciais para radioterapia apresentam alto custo e todas são importadas. Este trabalho teve como objetivo principal projetar, construir e caracterizar câmaras de ionização de placas paralelas em dosimetria de feixes de elétrons de aceleradores clínicos. Foram desenvolvidas cinco câmaras de ionização utilizando-se acrílico como material principal e tintas de grafite e de prata para a confecção dos eletrodos coletores. Uma das câmaras de ionização é a prova dágua. Todas as câmaras de ionização foram submetidas a feixes de radiação no Laboratório de Calibração de Instrumentos do IPEN e em três Serviços de Radioterapia na cidade de São Paulo onde foram realizados testes, como: tempo de estabilização, repetibilidade da resposta, estabilidade a médio prazo, corrente de fuga, corrente de saturação, eficiência de coleção de íons, linearidade de resposta, variação da resposta com a distância fonte-detector, efeito de polaridade, efeito cabo, simetria das câmaras de ionização, dependência angular. Além disso, as cinco câmaras de ionização foram calibradas em feixes padronizados de radiação gama, para aplicação em aceleradores clínicos de radioterapia. Os resultados foram satisfatórios para todos os testes realizados, mesmo para o efeito de polaridade no qual o resultado não foi menor que 1%; está de acordo com as câmaras comerciais reportadas na literatura. Assim, as câmaras de ionização desenvolvidas neste trabalho representam a possibilidade de uso em dosimetria de feixes de elétrons de aceleradores lineares em Serviços de Radioterapia. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0582 seconds