• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 4
  • 2
  • Tagged with
  • 17
  • 17
  • 11
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Growth dynamics of the acoustic reflex

Sprague, Barbara Helene. January 1977 (has links)
Thesis--Wisconsin. / Includes bibliographical references (leaves 197-198).
2

Acoustic Reflex Threshold Measurements in Infants

Abahazi, Dennis A. January 1975 (has links)
No description available.
3

Neural centers and pathways involved in the startle, orienting, and middle-ear reflex responses to acoustic stimuli

Chan, Chi-Kong January 1983 (has links)
This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).
4

High frequency acoustic reflexes in cochlea-impaired and normal ears

Jones, Karen Elizabeth 01 January 1990 (has links)
The acoustic reflex refers to the contraction of a middle ear muscle in response to sound. The contraction causes a stiffening of the middle ear system and, consequently, the flow of acoustic energy to the cochlea is impeded. By measuring the change in admittance in the auditory system during sound stimulation it is possible to indirectly monitor the middle ear muscle contractions. Such measurements provide useful information regarding the integrity of the auditory system and the location of the auditory pathology.
5

Influence of choking and arm lock technique in judo on the acoustic reflex threshold (ART) in healthy well-trained male and female judoka

Raschka, Christoph, Koch, Horst Josef/, Rau, Rudiger 05 1900 (has links)
No description available.
6

Efeito da estimulação contralateral nas medidas de reflectância acústica / Effect of contralateral stimulation on acoustic reflectance measurements

Pichelli, Tathiany Silva 22 November 2013 (has links)
Introdução: A Reflectância acústica é um procedimento introduzido mais recentemente na clínica audiológica, cuja abrangência diagnóstica pode ainda ser explorada. Suas medidas têm sido citadas como uma importante ferramenta na avaliação das afecções da orelha média, sendo um método considerado vantajoso em relação à timpanometria. Tem havido crescente interesse no estudo da estimulação acústica contralateral e seu efeito na ativação da via eferente auditiva. Estudos têm demonstrado que a introdução de estímulo simultâneo na orelha contralateral gera mudanças no padrão de respostas auditivas, tanto em medidas de emissões otoacústicas como em imitância acústica. Desta forma, surgiu o interesse em investigar a ocorrência de mudanças no padrão de resposta da curva de reflectância, quando pesquisada com a aplicação de ruído de banda larga na orelha contralateral. Objetivo: Verificar a influência da estimulação contralateral nas medidas de reflectância acústica da orelha média em adultos jovens. Metodologia: A casuística foi composta por 30 participantes de ambos os gêneros, na faixa etária de 18 a 30 anos. Procedimentos: Inspeção do meato acústico externo; Imitanciometria; Audiometria tonal limiar; Pesquisa do limiar de ruído branco; Pesquisa da Reflectância Acústica em dois passos: (a) foi obtida a curva de reflectância no intervalo de frequência de 200 a 6000 Hz na intensidade de 60dB SPL utilizando-se os estímulos chirp e de tons puros, e (b) o procedimento foi repetido com os mesmos parâmetros e estímulos, com a presença de ruído contralateral simultâneo por meio de fones de inserção a 30 dBNS em relação ao limiar de ruído branco. Resultados: Os resultados apontaram que não existem diferenças quando comparados gêneros. Quando a análise foi realizada separadamente por orelha houve diferenças entre estímulos chirp e de tons puros nas frequências de 1,5 e 2 kHz em orelha direita. Entre as condições de teste e reteste as diferenças estatísticas foram nas frequências de 0,25 e 0,5 kHz em orelha direita para estímulo de tons puros. A análise entre as condições de teste, reteste e teste com ruído contralateral apresentou diferença estatística na frequência de 2 kHz (pvalor 0,011 em teste e 0,002 em reteste) para estímulo chirp em orelha direita. A comparação entre orelhas esquerda e direita identificou diferenças estatísticas nas frequências de 3 e 4 kHz para os dois tipos de estímulos utilizados. Conclusão: Este estudo permite concluir que a ativação da via auditiva eferente por meio da estimulação acústica contralateral com ruído branco produz mudanças nos padrões de respostas da reflectância acústica, aumentando suas respostas e modificando a transferência de energia sonora da orelha média / Introduction: The acoustic reflectance is a procedure introduced more recently in audiology, which diagnostic scope can be further explored. Its measurements have been cited as an important instrument in the evaluation of middle ear affections, as a method considered advantageous in relation to tympanometry. There has been growing interest in the study of contralateral acoustic stimulation and its effect on activation of the auditory efferent pathway. Studies have shown that the introduction of simultaneous stimulation in the contralateral ear generates changes in the pattern of auditory responses in both measures of otoacoustic emissions as in acoustic impedance. Therefore, emerged the interest in investigating the occurrence of changes in the response pattern of the reflectance curve when studied with the application of broadband noise in the contralateral ear. Objective: Investigate the influence of contralateral stimulation on acoustic reflectance measurements of the middle ear in young adults. Methods: The sample consisted of 30 participants of both genders, aged 18-30 years. Procedures: Inspection of the external acoustic meatus; imitanciometry; pure tone audiometry threshold; threshold research of White Noise; acoustics reflectance research in two steps: (a) obtaining of reflectance curve in the frequency range 200-6000 Hz in the intensity of 60dB SPL using chirp stimuli and pure tone, and (b) repeating the procedure with the same parameters and stimuli with contralateral noise simultaneously through insert earphones at 30 dBNS over the white noise threshold. Results: The results presented no difference compared genres. The analysis performed separately by ear presented differences between chirp stimuli and pure tone at frequencies of 1.5 and 2 kHz in the right ear. Between test and retest conditions the statistical differences in frequencies were at frequencies of 0.25 and of 0.5 kHz in the right ear for pure tone. Analysis of the conditions of test, retest and test with contralateral noise presented statistical difference at the frequency of 2 kHz (pvalue on test 0.011 and 0.002 on retest) for chirp stimulus in the right ear. The comparison between left and right ears identified statistical differences at the frequencies of 3 and 4 kHz for the two types of stimuli used. Conclusion: This study shows that the activation of the efferent auditory pathway by contralateral acoustic stimulation with white noise produces changes in response patterns of acoustic reflectance, increasing their responses and modifying the transfer of sound energy from the middle ear
7

Acoustic Reflex Measurement

Schairer, Kim S., Feeney, M. Patrick, Sanford, Chris A. 01 July 2013 (has links)
A standard clinical immittance test battery includes measurements of the acoustic reflex, or more specifically, the middle ear muscle reflex (MEMR). The MEMR is the contraction of the stapedius muscle in response to high-level acoustic stimulation. Clinical MEMR measurements are made according to the American National Standards Institute standard for immittance instruments (S3.39–2012) by use of a 226-Hz probe tone in conjunction with a reflex-activating stimulus presented to the ipsilateral or contralateral ear. The MEMR is a bilateral response, which means that presenting the activator to one ear will elicit the response in both ears. In traditional clinical measurements, the reflex activator stimulus is a pure tone (500, 1000, 2000, or 4000 Hz) or a broadband noise, and the MEMR is measured at tympanometric peak pressure (TPP) as measured on the tympanogram. If the admittance of the test ear decreases by a criterion amount in the presence of the activator, for example, 0.02 to 0.03 mmho, the reflex is considered to be present. The lowest level at which an activator is presented and reliably elicits at least the criterion change in admittance is considered the MEMR threshold. The MEMR is typically present in ears with pure-tone behavioral thresholds of ≤60 dB HL at the activator frequencies (Gelfand 2009).
8

Transfer function of the embryonic avian middle ear /

Kim, Young Seon, January 2002 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2002. / Typescript. Vita. Includes bibliographical references. Also available on the Internet.
9

Transfer function of the embryonic avian middle ear

Kim, Young Seon, January 2002 (has links)
Thesis (Ph. D.)--University of Missouri-Columbia, 2002. / Typescript. Vita. Includes bibliographical references. Also available on the Internet.
10

Efeito da estimulação contralateral nas medidas de reflectância acústica / Effect of contralateral stimulation on acoustic reflectance measurements

Tathiany Silva Pichelli 22 November 2013 (has links)
Introdução: A Reflectância acústica é um procedimento introduzido mais recentemente na clínica audiológica, cuja abrangência diagnóstica pode ainda ser explorada. Suas medidas têm sido citadas como uma importante ferramenta na avaliação das afecções da orelha média, sendo um método considerado vantajoso em relação à timpanometria. Tem havido crescente interesse no estudo da estimulação acústica contralateral e seu efeito na ativação da via eferente auditiva. Estudos têm demonstrado que a introdução de estímulo simultâneo na orelha contralateral gera mudanças no padrão de respostas auditivas, tanto em medidas de emissões otoacústicas como em imitância acústica. Desta forma, surgiu o interesse em investigar a ocorrência de mudanças no padrão de resposta da curva de reflectância, quando pesquisada com a aplicação de ruído de banda larga na orelha contralateral. Objetivo: Verificar a influência da estimulação contralateral nas medidas de reflectância acústica da orelha média em adultos jovens. Metodologia: A casuística foi composta por 30 participantes de ambos os gêneros, na faixa etária de 18 a 30 anos. Procedimentos: Inspeção do meato acústico externo; Imitanciometria; Audiometria tonal limiar; Pesquisa do limiar de ruído branco; Pesquisa da Reflectância Acústica em dois passos: (a) foi obtida a curva de reflectância no intervalo de frequência de 200 a 6000 Hz na intensidade de 60dB SPL utilizando-se os estímulos chirp e de tons puros, e (b) o procedimento foi repetido com os mesmos parâmetros e estímulos, com a presença de ruído contralateral simultâneo por meio de fones de inserção a 30 dBNS em relação ao limiar de ruído branco. Resultados: Os resultados apontaram que não existem diferenças quando comparados gêneros. Quando a análise foi realizada separadamente por orelha houve diferenças entre estímulos chirp e de tons puros nas frequências de 1,5 e 2 kHz em orelha direita. Entre as condições de teste e reteste as diferenças estatísticas foram nas frequências de 0,25 e 0,5 kHz em orelha direita para estímulo de tons puros. A análise entre as condições de teste, reteste e teste com ruído contralateral apresentou diferença estatística na frequência de 2 kHz (pvalor 0,011 em teste e 0,002 em reteste) para estímulo chirp em orelha direita. A comparação entre orelhas esquerda e direita identificou diferenças estatísticas nas frequências de 3 e 4 kHz para os dois tipos de estímulos utilizados. Conclusão: Este estudo permite concluir que a ativação da via auditiva eferente por meio da estimulação acústica contralateral com ruído branco produz mudanças nos padrões de respostas da reflectância acústica, aumentando suas respostas e modificando a transferência de energia sonora da orelha média / Introduction: The acoustic reflectance is a procedure introduced more recently in audiology, which diagnostic scope can be further explored. Its measurements have been cited as an important instrument in the evaluation of middle ear affections, as a method considered advantageous in relation to tympanometry. There has been growing interest in the study of contralateral acoustic stimulation and its effect on activation of the auditory efferent pathway. Studies have shown that the introduction of simultaneous stimulation in the contralateral ear generates changes in the pattern of auditory responses in both measures of otoacoustic emissions as in acoustic impedance. Therefore, emerged the interest in investigating the occurrence of changes in the response pattern of the reflectance curve when studied with the application of broadband noise in the contralateral ear. Objective: Investigate the influence of contralateral stimulation on acoustic reflectance measurements of the middle ear in young adults. Methods: The sample consisted of 30 participants of both genders, aged 18-30 years. Procedures: Inspection of the external acoustic meatus; imitanciometry; pure tone audiometry threshold; threshold research of White Noise; acoustics reflectance research in two steps: (a) obtaining of reflectance curve in the frequency range 200-6000 Hz in the intensity of 60dB SPL using chirp stimuli and pure tone, and (b) repeating the procedure with the same parameters and stimuli with contralateral noise simultaneously through insert earphones at 30 dBNS over the white noise threshold. Results: The results presented no difference compared genres. The analysis performed separately by ear presented differences between chirp stimuli and pure tone at frequencies of 1.5 and 2 kHz in the right ear. Between test and retest conditions the statistical differences in frequencies were at frequencies of 0.25 and of 0.5 kHz in the right ear for pure tone. Analysis of the conditions of test, retest and test with contralateral noise presented statistical difference at the frequency of 2 kHz (pvalue on test 0.011 and 0.002 on retest) for chirp stimulus in the right ear. The comparison between left and right ears identified statistical differences at the frequencies of 3 and 4 kHz for the two types of stimuli used. Conclusion: This study shows that the activation of the efferent auditory pathway by contralateral acoustic stimulation with white noise produces changes in response patterns of acoustic reflectance, increasing their responses and modifying the transfer of sound energy from the middle ear

Page generated in 0.0607 seconds