Spelling suggestions: "subject:"airconditioning"" "subject:"matriconditioning""
71 |
A feasibility study of setting up a manufacturing arrangement in China for air-conditioning equipment with respect to the market within China and other South-east Asia countries /Lau, Chun-kay. January 1982 (has links)
Thesis (M.B.A.)--University of Hong Kong, 1982.
|
72 |
Design of an air conditioning system for a nuclear fallout shelterBhatal, Iqbal Singh, 1936- January 1961 (has links)
No description available.
|
73 |
The design and construction of an operating solar heating and cooling system at the School of Mechanical Engineering, Georgia Institute of TechnologyLeonaitis, Lance Leo 12 1900 (has links)
No description available.
|
74 |
Modeling and analysis of chilled water systemsKlawunder, Shawn Eric 05 1900 (has links)
No description available.
|
75 |
Cooling tower temperature setpoint optimization based on field dataGreene, Jeff Isom 12 1900 (has links)
No description available.
|
76 |
Air conditioner condenser optimizationPropst, James Lawson 08 1900 (has links)
No description available.
|
77 |
Nocturnal radiant cooling in hot, humid climatesMcCathren, James Robert 08 1900 (has links)
No description available.
|
78 |
Neuro-fuzzy predictive control of an information-poor systemThompson, Richard January 2002 (has links)
While modern engineering systems have become increasingly integrated and complex over the years, interest in the application of control techniques which specifically attempt to formulate and solve the control problem in its inherently uncertain environment has been moderate, at best. More specifically, although many control schemes targeted at Heating, Ventilating and Air-Conditioning (HVAC) systems have been reported in the literature, most seem to rely on conventional techniques which assume that a detailed, precise model of the HVAC plant exists, and that the control objectives of the controller are clearly defined. Experience with HVAC systems shows that these assumptions are not always justifiable, and that, in practice, these systems are usually characterized by a lack of detailed design data and a lack of a robust understanding of the processes involved. Motivated by the need to more efficiently control complex, uncertain systems, this thesis focuses on the development and evaluation of a new neuro-fuzzy model-based predictive control scheme, where certain variables used in the optimization remain in the fuzzy domain. The method requires no training data from the actual plant under consideration, since detailed knowledge of the plant is unavailable. Results of the application of the control scheme to the control of thermal comfort in a simulated zone and to the control of the supply air temperature of an air-handling unit in the laboratory are presented. It is concluded that precious resources (as measured by actuator activity, for example) need not be wasted when controlling these systems. In addition, it is also shown that a very precise (and sometimes not necessarily accurate) control value computed at each sample is unnecessary. Rather, by defining the system and its environment in the fuzzy domain, the fuzzy decision algorithms developed here may be employed to get an "acceptable" control performance.
|
79 |
The potential of building-integrated photovoltaic systems in Zimbabwe and their application to thermal environmental controlMunyati, Edmund January 1999 (has links)
No description available.
|
80 |
Fault detection and diagnosis in HVAC systems using analytical modelsSalsbury, Timothy I. January 1996 (has links)
Faults that develop in the heat exchanger subsystems in air-conditioning installations can lead to increased energy costs and jeopardise thermal comfort. The sensor and control signals associated with these systems contain potentially valuable information about the condition of the system, and energy management and control systems are able to monitor and store these signals. In practice, the only checks made are to verify set-points are being maintained and that certain critical variables remain within predetermined limits. This approach may allow the detection of certain abrupt or catastrophic faults, but degradation faults often remain undetected until their effects become quite severe. This thesis investigates the appropriateness of using mathematical models to track the development of degradation faults. An approach is developed, which is based on the use of analytical models in conjunction with a recursive parameter estimation algorithm. A subset of the parameters of the models, which are closely related to faults, is estimated recursively. Significant deviations in the values of the estimated parameters from nominal values, which represent `correct operation', are used as an indication that the system has developed a fault. The extent of the deviation from the nominal values is used as an estimate of the degree of fault. This thesis develops the theory and examines the robustness of the parameter estimator using simulation-based testing. Results are also presented from testing the fault detection and diagnosis scheme with data obtained from a simulated air-conditioning system and from a full size test installation.
|