• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Energieffektivisering av luftningssteget på Käppalaverket, Lidingö / Energy optimization of the aeration at Käppala wastewater treatment plant in Stockholm

Thunberg, Andreas January 2007 (has links)
<p>This master thesis in energy optimization was made during the autumn of 2006 at Käppala wastewater treatment plant in Lidingö, Stockholm. A preceding thesis, where all electricity consumption was mapped, showed that the aeration in the biological treatment is the single largest consumer in the plant, and it is therefore of interest to reduce this cost. The oxygen control strategy used at Käppala WWTP is working well from a nutrient removal point of view, but not from an economic one. The last aerobic zones have a very low oxygen consumption during low loading periods which give rise to enhanced dissolved oxygen concentrations with excessive costs and reduced denitrification as a result. But also during periods of normal loading unnecessary high oxygen concentration are sometimes given.</p><p>By modifying the aeration control strategy three full-scale experiments have been made, with the intention to reduce the air consumption. The experiments were carried out during week 37-50 in the autumn of 2006 and showed that savings could be made.</p><p>The regular oxygen control at Käppala WWTP controls the oxygen level in the aerobic compartment with two DO-setpoints; one in the first aerobic zone and one in the last. The zones in between are controlled by an airflow fractionation depending on the oxygen level in the first and last zone. In the first strategy to be evaluated, all four zones in the aerated part were individually controlled with its own setpoint. Two different setpoint combinations were tested. By using the fact that the efficiency in the oxygen transfer rate was higher at low airflows, savings of approximately 16 % were achieved. In the second strategy tested, an ammonia-feedback control combined with a DO-feedback controlled the DO-set point in the first aerobic zone. This strategy adjusted the DO- set points to the loading variations, and this gave a decreased airflow of approximately 9 %. Finally the two strategies were combined. All zones were then controlled individually with DO-set points set by an ammonium-feedback and a DO-feedback. The strategy gave savings in the airflow of approximately 18 %. In all three trials the aerated zones were more efficiently used, and the estimated savings are 550 000 SEK/year, and with a preserved nutrient removal efficiency.</p> / <p>Under hösten 2006 har ett examensarbete om energieffektivisering på Käppalaverket på Lidingö utförts. Ett föregående examensarbete där all elenergiförbrukning kartlades visade att blåsmaskinerna i biosteget står för den enskilt största förbrukningen i verket och det är därför av intresse att minska denna kostnad. Syrestyrningsstrategin som används på Käppalaverket fungerar mycket bra ur reningssynpunkt, men är inte optimal ur energisynpunkt. Dels luftas de första aeroba zonerna för mycket vid låg belastning vilket ger upphov till kraftigt förhöjda syrekoncentrationer i de sista aeroba zonerna med höga luftningskostnader och risk för försämrad denitrifikation, men även under normal belastning har det visat sig att onödigt höga syrekoncentrationer ibland ges.</p><p>Tre fullskaliga optimeringsförsök har utförts, med syfte att minska luftförbrukningen med bibehållen reningsgrad. Försöken pågick från vecka 37 till 50 hösten 2006, och visade att det finns möjlighet att spara energi genom att modifiera syrestyrningsstrategin.</p><p>Den reguljära syreregleringen i Käppalaverket styr syrehalten i den aeroba bassängen mot två syrebörvärden; ett i den första luftade zonen och ett i den sista. Luftflödet till de mellanliggande zonerna styrs av luftflödesandelar beroende på syrehalten i dessa två zoner. Den första strategin som utvärderades styrde istället samtliga zoner individuellt med egna börvärden, där två olika strukturer på de satta börvärdena användes. Genom att utnyttja en högre effektivitet i syreöverföringshastigheten vid låga luftflöden uppnåddes luftflödesbesparingar på ca 16 % i första försöket.</p><p>I den andra strategin styrdes syrebörvärdet i den första luftade zonen med hjälp av två återkopplingar, en från utgående ammoniumhalt och en från syrehalten i den sista luftade zonen.</p><p>Tack vare att strategin anpassade syrebörvärdena efter belastningen av syretärande ämnen erhölls luftflödesbesparingar på ca 9 %. Slutligen kombinerades de två strategierna; samtliga zoner styrdes individuellt med börvärden satta av en ammonium-återkoppling och en syre-återkoppling. Strategin medförde luftflödesbesparingar på ca 18 %. I samtliga försök utnyttjades de luftade zonerna bättre, och besparingspotentialen uträknad från 2005 års elpriser blev som mest 550 000 SEK/år, detta med en bibehållen reningsgrad.</p>
2

Energieffektivisering av luftningssteget på Käppalaverket, Lidingö / Energy optimization of the aeration at Käppala wastewater treatment plant in Stockholm

Thunberg, Andreas January 2007 (has links)
This master thesis in energy optimization was made during the autumn of 2006 at Käppala wastewater treatment plant in Lidingö, Stockholm. A preceding thesis, where all electricity consumption was mapped, showed that the aeration in the biological treatment is the single largest consumer in the plant, and it is therefore of interest to reduce this cost. The oxygen control strategy used at Käppala WWTP is working well from a nutrient removal point of view, but not from an economic one. The last aerobic zones have a very low oxygen consumption during low loading periods which give rise to enhanced dissolved oxygen concentrations with excessive costs and reduced denitrification as a result. But also during periods of normal loading unnecessary high oxygen concentration are sometimes given. By modifying the aeration control strategy three full-scale experiments have been made, with the intention to reduce the air consumption. The experiments were carried out during week 37-50 in the autumn of 2006 and showed that savings could be made. The regular oxygen control at Käppala WWTP controls the oxygen level in the aerobic compartment with two DO-setpoints; one in the first aerobic zone and one in the last. The zones in between are controlled by an airflow fractionation depending on the oxygen level in the first and last zone. In the first strategy to be evaluated, all four zones in the aerated part were individually controlled with its own setpoint. Two different setpoint combinations were tested. By using the fact that the efficiency in the oxygen transfer rate was higher at low airflows, savings of approximately 16 % were achieved. In the second strategy tested, an ammonia-feedback control combined with a DO-feedback controlled the DO-set point in the first aerobic zone. This strategy adjusted the DO- set points to the loading variations, and this gave a decreased airflow of approximately 9 %. Finally the two strategies were combined. All zones were then controlled individually with DO-set points set by an ammonium-feedback and a DO-feedback. The strategy gave savings in the airflow of approximately 18 %. In all three trials the aerated zones were more efficiently used, and the estimated savings are 550 000 SEK/year, and with a preserved nutrient removal efficiency. / Under hösten 2006 har ett examensarbete om energieffektivisering på Käppalaverket på Lidingö utförts. Ett föregående examensarbete där all elenergiförbrukning kartlades visade att blåsmaskinerna i biosteget står för den enskilt största förbrukningen i verket och det är därför av intresse att minska denna kostnad. Syrestyrningsstrategin som används på Käppalaverket fungerar mycket bra ur reningssynpunkt, men är inte optimal ur energisynpunkt. Dels luftas de första aeroba zonerna för mycket vid låg belastning vilket ger upphov till kraftigt förhöjda syrekoncentrationer i de sista aeroba zonerna med höga luftningskostnader och risk för försämrad denitrifikation, men även under normal belastning har det visat sig att onödigt höga syrekoncentrationer ibland ges. Tre fullskaliga optimeringsförsök har utförts, med syfte att minska luftförbrukningen med bibehållen reningsgrad. Försöken pågick från vecka 37 till 50 hösten 2006, och visade att det finns möjlighet att spara energi genom att modifiera syrestyrningsstrategin. Den reguljära syreregleringen i Käppalaverket styr syrehalten i den aeroba bassängen mot två syrebörvärden; ett i den första luftade zonen och ett i den sista. Luftflödet till de mellanliggande zonerna styrs av luftflödesandelar beroende på syrehalten i dessa två zoner. Den första strategin som utvärderades styrde istället samtliga zoner individuellt med egna börvärden, där två olika strukturer på de satta börvärdena användes. Genom att utnyttja en högre effektivitet i syreöverföringshastigheten vid låga luftflöden uppnåddes luftflödesbesparingar på ca 16 % i första försöket. I den andra strategin styrdes syrebörvärdet i den första luftade zonen med hjälp av två återkopplingar, en från utgående ammoniumhalt och en från syrehalten i den sista luftade zonen. Tack vare att strategin anpassade syrebörvärdena efter belastningen av syretärande ämnen erhölls luftflödesbesparingar på ca 9 %. Slutligen kombinerades de två strategierna; samtliga zoner styrdes individuellt med börvärden satta av en ammonium-återkoppling och en syre-återkoppling. Strategin medförde luftflödesbesparingar på ca 18 %. I samtliga försök utnyttjades de luftade zonerna bättre, och besparingspotentialen uträknad från 2005 års elpriser blev som mest 550 000 SEK/år, detta med en bibehållen reningsgrad.

Page generated in 0.1202 seconds