• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Radiografia com partículas alfa induzida por nêutrons / Neutron-Induced alpha radiography

Pereira, Marco Antônio Stanojev 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma técnica radiográfica para a inspeção de amostras finas, que emprega feixes de partículas - ? como radiação penetrante e, detectores de traços nucleares de estado sólido para o registro da imagem. O feixe é gerado em uma tela de boro natural quando irradiada com nêutrons térmicos e o detector utilizado foi o CR-39. A interação das partículas - ? com o detector geram danos, os quais sob a ação de uma solução química adequada transformam-se em traços, as unidades básicas formadoras da imagem. Foi desenvolvido um sistema digital próprio para a aquisição, análise e processamento dos dados e das imagens registradas nos detectores. As condições ótimas de irradiação e de revelação para a obtenção de uma radiografia são 1,3 horas e 25 minutos a 70°C, respectivamente. Nestas condições a técnica é capaz de analisar amostras com até 10?m de espessura, com uma resolução espacial de 32?m. O emprego do sistema digital permitiu uma redução significativa no tempo despendido para a aquisição e análise de dados e, uma melhoria na visualização das imagens radiográficas registradas. Além disto permitiu acesso a novos dados referentes aos traços registrados, o que abriu novas perspectivas de pesquisa pois, tem-se acesso aos parâmetros fundamentais que norteiam a teoria da formação da imagem em detectores de traços nucleares utilizada neste trabalho. São apresentadas algumas radiografias que demonstram a potencialidade da técnica desenvolvida. Quando comparada com as outras técnicas radiográficas usuais, empregadas para inspecionar amostras finas, a desenvolvida no presente trabalho permite um menor tempo para a obtenção da imagem, não é necessário a manipulação de materiais radioativos líquidos e, o filme empregado é praticamente insensível às radiações ?, ?, raios - X e luz visível. / A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the ? - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70°C respectively. For such conditions samples having 10?m in thickness can be inspected with a spatial resolution of 32?m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to ?, ?, X-ray and visible light.
2

Radiografia com partículas alfa induzida por nêutrons / Neutron-Induced alpha radiography

Marco Antônio Stanojev Pereira 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma técnica radiográfica para a inspeção de amostras finas, que emprega feixes de partículas - ? como radiação penetrante e, detectores de traços nucleares de estado sólido para o registro da imagem. O feixe é gerado em uma tela de boro natural quando irradiada com nêutrons térmicos e o detector utilizado foi o CR-39. A interação das partículas - ? com o detector geram danos, os quais sob a ação de uma solução química adequada transformam-se em traços, as unidades básicas formadoras da imagem. Foi desenvolvido um sistema digital próprio para a aquisição, análise e processamento dos dados e das imagens registradas nos detectores. As condições ótimas de irradiação e de revelação para a obtenção de uma radiografia são 1,3 horas e 25 minutos a 70°C, respectivamente. Nestas condições a técnica é capaz de analisar amostras com até 10?m de espessura, com uma resolução espacial de 32?m. O emprego do sistema digital permitiu uma redução significativa no tempo despendido para a aquisição e análise de dados e, uma melhoria na visualização das imagens radiográficas registradas. Além disto permitiu acesso a novos dados referentes aos traços registrados, o que abriu novas perspectivas de pesquisa pois, tem-se acesso aos parâmetros fundamentais que norteiam a teoria da formação da imagem em detectores de traços nucleares utilizada neste trabalho. São apresentadas algumas radiografias que demonstram a potencialidade da técnica desenvolvida. Quando comparada com as outras técnicas radiográficas usuais, empregadas para inspecionar amostras finas, a desenvolvida no presente trabalho permite um menor tempo para a obtenção da imagem, não é necessário a manipulação de materiais radioativos líquidos e, o filme empregado é praticamente insensível às radiações ?, ?, raios - X e luz visível. / A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the ? - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70°C respectively. For such conditions samples having 10?m in thickness can be inspected with a spatial resolution of 32?m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to ?, ?, X-ray and visible light.
3

Radiografia com elétrons induzida por nêutrons / NEUTRON INDUCED ELETRON RADIGRAPHY

Andrade, Marcos Leandro Garcia 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma nova técnica radiográfica que utiliza feixes de elétrons de baixa energia como radiação penetrante para inspecionar amostras finas com espessuras da ordem de micra. Esta técnica é denominada, radiografia com elétrons induzida por nêutrons e os feixes são obtidos mediante a irradiação de uma tela de gadolínio com nêutrons térmicos. Foram determinadas as condições ótimas para a obtenção de radiografias no filme convencional para raios - X, Kodak Industrex AA, utilizando um sistema digital para análise do grau de enegrecimento dos filmes. Todas as irradiações foram realizadas em um equipamento radiográfico instalado no canal de irradiação 08 do reator nuclear de pesquisas IEA-R1 do IPEN-CNEN/SP. O tempo de irradiação necessário para se obter a radiografia com o melhor contraste foi de 100 segundos e nesta condição foi possível discernir 1 ?m em 24 ?m de alumínio com uma resolução máxima de 32 ?m. As imagens radiográficas obtidas no IPENCNEN/ SP por esta técnica apresentam visualmente uma qualidade superior quando comparadas as obtidas pelas outras técnicas radiográficas usuais que utilizam elétrons como radiação penetrante e filmes para o registro da imagem. Além disto, o sistema digital propiciou uma maior praticidade referente à aquisição e a análise dos dados e uma melhor visualização das imagens radiográficas. / In the present paper a new radiography technique, the \"Neutron Induced Electron Radiography - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole #8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 ?m in 24 ?m of aluminum at a resolution of 32 ?m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization.
4

Radiografia com elétrons induzida por nêutrons / NEUTRON INDUCED ELETRON RADIGRAPHY

Marcos Leandro Garcia Andrade 25 February 2008 (has links)
No presente trabalho foi desenvolvida uma nova técnica radiográfica que utiliza feixes de elétrons de baixa energia como radiação penetrante para inspecionar amostras finas com espessuras da ordem de micra. Esta técnica é denominada, radiografia com elétrons induzida por nêutrons e os feixes são obtidos mediante a irradiação de uma tela de gadolínio com nêutrons térmicos. Foram determinadas as condições ótimas para a obtenção de radiografias no filme convencional para raios - X, Kodak Industrex AA, utilizando um sistema digital para análise do grau de enegrecimento dos filmes. Todas as irradiações foram realizadas em um equipamento radiográfico instalado no canal de irradiação 08 do reator nuclear de pesquisas IEA-R1 do IPEN-CNEN/SP. O tempo de irradiação necessário para se obter a radiografia com o melhor contraste foi de 100 segundos e nesta condição foi possível discernir 1 ?m em 24 ?m de alumínio com uma resolução máxima de 32 ?m. As imagens radiográficas obtidas no IPENCNEN/ SP por esta técnica apresentam visualmente uma qualidade superior quando comparadas as obtidas pelas outras técnicas radiográficas usuais que utilizam elétrons como radiação penetrante e filmes para o registro da imagem. Além disto, o sistema digital propiciou uma maior praticidade referente à aquisição e a análise dos dados e uma melhor visualização das imagens radiográficas. / In the present paper a new radiography technique, the \"Neutron Induced Electron Radiography - NIER, to inspect low thickness samples on the order of micra, has been developed. This technique makes use of low energy electrons as penetrating radiation generated from metallic gadolinium screens when irradiated by thermal neutrons. The conditions to obtain the best image for the conventional X-ray film Kodak-AA were determined by using a digital system to quantify the darkening level of the film. The irradiations have been performed at a radiography equipment installed at the beam-hole #8 of the 5 MW IEA-R1 nuclear research reactor of IPEN-CNEN/SP. The irradiation time to obtain the best radiography was 100 seconds and for such condition the technique was able to discern 1 ?m in 24 ?m of aluminum at a resolution of 32 ?m. By visual comparison the images obtained by the NIER shown a higher quality when compared with the ones from other usual techniques the make use of electrons a penetrating radiation and films for image registration. Furthermore the use of the digital system has provided a smaller time for data acquisition and data analysis as well as an improvement in the image visualization.

Page generated in 0.1376 seconds