• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Bench Top Study Of The Optimization Of Lvad Cannula Implantation To Reduce Risk Of Cerebral Embolism

Clark, William D 01 January 2012 (has links)
Physical bench top experiments are performed to validate and complement ongoing computational fluid dynamics (CFD) analyses of ventricular assist device (VAD) circulation. VADs are used in patients whose hearts do not function to their maximum potential due advanced stages of heart disease and, consequently, are unable to adequately supply blood to the systemic circulation. VADs are commonly utilized as a bridge-to-transplantation, meaning that they are implanted in patients while waiting for a heart transplant. In such cases of long term utilization of VADs, it has been reported in the literatures that thrombo-embolic cerebral events occur in 14-47% of patients over the period of 6 to 12 months. This is a result of thrombus forming despite the use of anticoagulants and advances in VAD design. Accepting current rates of thrombo-embolisms, the main objective of the project is to identify and propose an optimal surgical cannula implantation orientation aimed at reducing the rate of thrombi reaching the carotid and vertebral arteries and thus reduce the morbidity and mortality rate associated with the long term use of VADs to patients suffering from advanced heart failure. The main focus of the experiment is on the physical aspect using a synthetic anatomically correct model constructed by rapid prototyping of the human aortic arch and surrounding vessels. Three VAD cannula implantation configurations are studied with and without bypass to the left carotid artery or to the Innominate artery with ligation of the branch vessel at its root. A mixture of water and glycerin serves to match blood viscosity measured with a rotating cone-plate viscometer. The Reynolds number in the ascending aorta is matched in the flow model. A closed loop mock circulatory system is then realized. In order to match the Reynolds number in the ascending aorta and LVAD cannula with that of the CFD model, a volumetric flow rate of 2.7 liters per minute is supplied through the synthetic VAD cannula and 0.9 liter per minute is supplied to the ascending aorta. Flow rates are measured using rotary flow meters and a pressure sensor is used to ensure a mean operating pressure of 100 mmHg is maintained. Synthetic acrylic blood iv clots are injected at the inlet of the VAD cannula and they are captured and counted at the vertebral and carotid arteries. The sizes of the thrombi simulated are 2, 3.5 and 5 mm which are typical of the range of diameters encountered in practice. Nearly 300 particles are released over 5 separate runs for each diameter, and overall embolization rates as well as individual embolization rates are evaluated along with associated confidence levels. The experimental results show consistency between CFD and experiment. Means comparison of thromboembolization rates predicted by CFD and bench-top results using a Z-score statistic with a 95% confidence level results in 22 of 24 cases being statistically equal. This study provides confidence in the predictive capabilities of the bench-top model as a methodology that can be utilized in upcoming studies utilizing patient-specific aortic bed model.

Page generated in 0.0711 seconds