• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 112
  • 32
  • 4
  • 1
  • Tagged with
  • 149
  • 85
  • 71
  • 48
  • 20
  • 19
  • 17
  • 16
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Stimulation ultrasonore en thermographie infrarouge : intégration des appareillages et développement de procédures expérimentales

Piau, Jean-Marc 12 April 2018 (has links)
Ce mémoire présente l'intégration des appareillages et le développement de procédures expérimentales pour la réalisation d'inspection non destructive effectuée par vibrothermographie stimulée par ultrasons. Le laboratoire de vision et systèmes numériques (LVSN) de l'Université Laval s'est doté, en 2005, de deux sources ultrasonores destinées à l'étude et le développement d'une technique non destructive manquante au laboratoire. Cette technique s'appelle la vibrothermographie stimulée par ultrasons du fait que l'on utilise une caméra infrarouge pour cartographier thermiquement, sans contact, la surface d'un matériau stimulé mécaniquement par ondes mécaniques de fréquences ultrasoniques. Après avoir lu ce mémoire, le lecteur devrait être capable de réaliser une inspection non destructive efficace par vibrothermographie stimulée par ultrasons. Ce dispositif intégré au cours de ma maîtrise est maintenant opérationnel au sein du laboratoire pour des fins d'élargissement des techniques d'inspection non destructive de matériaux.
72

Banc de caractérisation pour lentilles panoramiques

Poulin-Girard, Anne-Sophie 18 April 2018 (has links)
Les particularités des lentilles panoramiques font de leur caractérisation un défi. Pour les applications de vision, une connaissance de la distorsion est essentielle pour produire des vues naturelles. Aussi, toutes les directions étant importantes, la qualité de l'image doit être uniforme sur tout le champ de vue. Nous avons donc développé un banc de caractérisation pour lentilles panoramiques. Avec des cibles référencées, nous avons obtenu avec rapidité et facilité les profils de distorsion, ce qui a permis de calculer la résolution instantanée linéaire sur tout le champ de vue. Également, des cibles inclinées ont été utilisées pour déterminer la fréquence spatiale où la MTF est de 50% en fonction de l'angle dans le champ de vue. À l'aide de deux caméras, nous avons testé deux lentilles panomorphes et deux lentilles fisheyes pour lesquelles nous avons calculé la résolution instantanée et les courbes de MTF et comparé certains résultats à des simulations.
73

Réalisation d'une preuve de concept pour un spectromètre imageur à caméra plénoptique

Côté, Alex 23 April 2018 (has links)
Ce mémoire présente l’utilisation d’une caméra plénoptique comme détecteur d’un interféromètre à transformée de Fourier. Des algorithmes d’acquisition, de variation numérique du foyer et de télémétrie ont été développées pour le traitement des données de deux montages. Un interféromètre fixe a été utilisé pour étudier l’interaction entre les franges d’interférence dues au désalignement de l’instrument et une caméra plénoptique. Un interféromètre à transformée de Fourier a ensuite été utilisé pour obtenir des mesures télémétriques d’une scène en transmission et en réflexion dans différentes bandes spectrales. Une estimation de distance à pu être obtenue à partir de chaque bande spectrale. / This master thesis present the usage of a light field camera as a detector for a Fourier transform interferometer. An algorithm for data acquisition, numerical refocus and ranging has been develloped to process the data from two experimental setups. A fixed interferometer has been used to study the interaction between misalignement fringes from the instrument and the light field camera. A Fourier transform interferometer was then used to obtain hyperspectral ranging data from a transmissive and reflective scene. It was possible to obtain a distance estimation in each spectral band.
74

Wearable electronic sensors for vital sign monitoring

Besrour, Marouen 01 May 2018 (has links)
On propose dans ce mémoire un nouveau type de capteur pour la mesure des fonctions respiratoires et cardiaques à des fins médicales. Le système offre la possibilité de mesurer le rythme respiratoire et la profondeur de respiration et de transmettre les données vers une station locale pour une analyse plus poussé et un diagnostic. Le capteur proposé est basé sur une approche électromagnétique où on utilise deux antennes posées sur la cage thoracique du patient. Lorsque le patient inspire et expire l’air avec ses poumons, le diamètre de la cage thoracique de ce dernier va augmenter et par conséquent la distance entre les deux antennes aussi. Le système mesure l’écart relatif entre les deux pour extraire le rythme respiratoire. Le point clé du capteur est d’encoder le signal de respiration sous forme de différence de phase entre l’onde émise et l’onde reçue conférant au système une bonne immunité contre les bruits des signaux externes. Le design a été implémenté sur un PCB (46mm x 46mm) pour fournir une preuve de concept de la méthode proposée. Les tests ont été conduits sur trois sujets de deux sexes et d’âges distincts. Les données mesurées démontrent que le système fonctionne sur différentes morphologies physiques. Finalement, le capteur a été capable de recueillir avec grande précision le rythme respiratoire et même la fréquence cardiaque. / We propose in this project a wearable electronic Patch Radar sensor that can monitor respiration rate and respiration depth continuously in real-time and transmit data to a base station for analysis. The device relies on a two-antenna configuration. Both antennas are bent to the patient chest, and when the patient breathes, the mechanical movement of the chest wall changes the distance between them. The system measures the relative distance between the antennas to extract the respiration pattern. The key feature of the sensor is that it transduces respiration movements to phase shifts in RF wave signals which make it very robust against external interferences. The design was implemented on a PCB (46mm x 46mm) to demonstrate a proof of concept for the proposed device. The system was able to acquire respiration signals and even cardiac frequency. Experimental results are presented for three different subjects, an adult male and female and a child. The data gathered gives enough sensitivity and accuracy to state that the device can work with different physical morphologies.
75

Contrôleur évolutif et optimisé pour les miroirs déformables ferrofluidiques dans le cadre de l'optique adaptative

Libbrecht, Christophe 23 April 2018 (has links)
L’optique adaptative est une technologie s’intégrant de plus en plus à de nombreuses applications, de la capture d’images astronomiques à la transmission de données en télécommunication, tout en passant, par exemple, par l’amélioration des diagnostics en ophtalmologie. Son atout principal réside dans un miroir déformable lui permettant d’améliorer un signal dégradé par des perturbations. Il existe une grande variété de miroirs déformables. Certains ont une surface continue ; d’autres sont segmentés. Toute une batterie de techniques sont employées pour déformer et contrôler leur surface : des systèmes hydrauliques, piézoélectriques, électrostatiques et magnétiques ont été développés au fil des dernières années. Les derniers nés durant cette évolution technologique sont les miroirs ferrofluidiques. Les miroirs ferrofluidiques ont de nombreux points forts. Outre leur faible coût de conception, ils ont la capacité de fournir de grandes amplitudes (de l’ordre du millimètre) de déformation sous l’influence d’une combinaison de champs magnétiques. Ces miroirs sont développés et étudiés au sein des laboratoires du COPL à l’université Laval. Ils sont l’objet principal sur lequel s’appliquera le présent travail. Actuellement, le nombre sans cesse croissant des actionneurs oblige le développement de méthodes optimales de contrôle. Selon le domaine d’application, une image ou un signal capté nécessitera une dizaine, voire plusieurs centaines de corrections par seconde. Il est donc important que les calculs se fassent rapidement. D’autre part, ce nombre croissant d’actionneurs amène la question de la meilleure stratégie à suivre pour le contrôle optimal de la surface du miroir. Doit-on se restreindre à l’utilisation d’un unique contrôleur ou, au contraire, à en multiplier leur nombre au point que chaque actionneur possédera son propre contrôleur ? Quelle que soit la stratégie déployée, la phase de calibration est une étape clé. Pour un contrôleur en optique adaptative, elle est assez simple même si elle s’avère parfois longue lors de la recherche des paramètres optimaux. Quelle est la meilleure méthode pour calibrer le contrôleur ? Une calibration automatisée est-elle envisageable ? Peut-on espérer que le contrôleur évolue et s’adapte si les conditions ambiantes changent et cela sans intervention humaine ? Plus en avant, les questions suivantes concernent la mise en application de la stratégie : est-elle aisément applicable ? Sous quelles conditions ? Y aura-t-il des limitations ? Si oui, sont-elles significatives ? Sont-elles insurmontables ? Le présent travail tente de répondre à ces questions dans le cadre du contrôle de miroirs ferrofluidiques, quel que soit le contexte de l’utilisation d’un tel miroir. L’objectif final est de développer un contrôleur évolutif et optimal capable de gérer un système équipé aussi bien de quelques dizaines d’actionneurs que de plusieurs centaines, et s’ajustant de lui-même aux conditions environnementales sans cesse en évolution. / Adaptive optics is an evolving technology and integrated part of many applications. Its contributions extend from the astronomical imaging to the data transmission in telecommunications domain including the improvement of ophthalmologic diagnostics. Its main asset consists of its deformable mirrors and, thus, its ability to correct a signal degraded by random perturbations. There are many kinds of deformable mirrors. These with a continuous surface and also with several segments. A great variety of methods exists to control the surface geometry: hydraulics, piezoelectric, electrostatic and magnetic systems have been developed in the last years. The most recent creation in adaptive optics is the ferrofluidic mirror. The ferrofluidic mirrors have many advantages. First, their manufacturing cost is very low. Moreover, a simple combination of magnetic fields is required to modify the shape of their surface and can give strong amplitudes of deformation (about millimeter). These mirrors are developed and studied in the COPL laboratory of Université Laval where they are the main target of the actual work. Nowadays the constant increasing number of actuators decrees the development of optimized methods to control deformable mirrors. A captured image or signal can require from some tens to several hundreds of Hertz to be corrected. The calculations must be at their fastest. On other hand, the increasing number of actuators raises a question about what strategy to deploy for getting the best control on the surface of deformable mirrors. Do we use a single controller for all the actuators? Or on the contrary do we need to equip each actuator with a dedicated controller? For any chosen strategy, the most important step is the calibration phase. In adaptive optics, this procedure is quite simple even though it sometimes takes a long time for finding the optimized parameters. What is the best method to calibrate a controller? Is an automatic calibration possible? Can we develop an evolving controller able to adapt to environmental variations without human action. There is some interrogation about the best way to apply th strategy. Can it be more efficient? Are there any limitations? If so, can we solve them? The subject of this document is to answer the previous questions regarding ferrofluidic mirrors. The final purpose of this work is to develop an evolving and optimized controller able to manage systems with several tens as well as several hundreds of actuators and, also, adapt itself to variations of surrounding conditions.
76

Study and design of a small kerosene burner

Béland, Mathieu 13 February 2020 (has links)
L’objectif principal de ce travail est de concevoir un petit brûleur au kérosène pour étudier la propriété ignifuge de matériaux composites sous attaque de flamme. Les normes AC20-135 et ISO 2685 décrivent de quelle manière les tests pour démontrer la capacité ignifuge d’un matériau doivent se dérouler. Ces normes sont utilisées pour dresser les requis pour la conception de ce petit brûleur au kérosène. Des gouttelettes liquides de jet-A sont pulvérisées pour alimenter la flamme en carburant tandis que l’air est amené via une conduite annulaire autour de l’injecteur. La combustion génère une flamme non-confinée. L’injecteur sélectionné est un atomiseur à pression avec ligne de retour de la compagnie Delavan. Un swirler en impression 3D de plastique est placé dans le brûleur près de la sortie d’air pour augmenter le mélange entre les gouttelettes de jet-A et l’air. Une analyse de mécanique des fluides numériques (MFNou CFDen anglais) est présentée pour mieux comprendre l’aérodynamique dans un brûleur et pour concevoir le swirler. Le brûleur est conçu pour permettre de facilement changer le swirler pour tester différents angles d’aubes. Un banc d’essai a été mis en place pour tester l’effet de ces swirlers sur le flux thermique de la flamme. Les effets de la puissance du brûleur, du rapport d’équivalence et de la distance entre le brûleur et la position de la mesure ont été investigués avec des essais expérimentaux. Un swirler de15 aubes avec un angle d’aube de 25°a été choisi. Parmi toutes les distances axiales testées expérimentalement avec le swriler choisi, il est possible d’atteindre le flux thermique requis de 116 kW/m2 avec le plus de configurations de flamme possible lorsque cette distance est de 7.6 cm (3 po.) du brûleur. Il est possible de générer une flamme avec un diamètre inférieur à 6.4 cm (2.5 po.) tout en atteignant le flux thermique requis de 116 kW/m2. Ceci permet d’effectuer des tests sur des petits échantillons et de réduire les coûts des tests de pré-certification. Pour atteindre cette configuration de flamme, il faut ajuster la puissance du brûleur entre 10 kW et 20 kW avec un rapport d’équivalence entre 0.7 et 0.9. / The main objective of this work is to design a small kerosene burner to study the fireproofing capacity of composite material under flame attack. The standards AC20-135 and ISO-2685 described how the fireproofing tests have to be performed and are used to set the requirements for the design of the small kerosene burner. The burner sprays liquid jet-A droplets and air is flowing around the injector in an annular chamber. The combustion generates an unconfined flame. The fuel injector selected is a Delavan spill-return pressure atomizer. There is a custom 3D printed plastic swirler at the air exit near the combustion area to increase the mixing between air and jet-A droplets. A computational fluid dynamic analysis (CFD) is presented to better understand the aerodynamic of the burner and to design the swirler. The design of the burner allows to easily change the swirler to test different vane angles. An experimental test bench is designed to test the effect of these swirlerson the heat flux under multiple combinations of burner power and equivalence ratio at four axial measurement locations. The experimental investigation allows selecting the final configuration and parameters for the burner. The chosen swirler has 15 vanes that are oriented 25° to the burner axis. The best axial location for the measurements is at 7.6 cm (3 in.). It is possible to generate a flame with a diameter smaller than 6.4 cm (2.5 in.) while reaching the required heat flux of 116 kW/m2. This accommodates smaller coupon sizes and reduces cost for pre-certification testing. To achieve this flame configuration, the burner power should be set between 10 kW to 20 kW with an equivalence ratio between 0.7 and 0.9.
77

Mise au point d'un système de multi-minibioréacteurs pour la culture de cellules animales

Sánchez-Aguilar, Ricardo 11 April 2018 (has links)
Le développement de bioprocédés pour la culture des cellules animales est d'une grande importance pour la biotechnologie, dû aux nombreuses applications biomédicales de ces cellules. Dans ce travail, la mise au point d'un système de contrôle ainsi que la conception, la caractérisation et l'utilisation de minibioréacteurs à échelle réduite (30-100 mL), entièrement équipés et automatisés pour la culture cellulaire, sont présentées. Les paramètres des contrôleurs ont de plus été optimisés pour des bioréacteurs de différentes tailles (500 mL et 15 L) avec différents volumes de travail (0,3, 0,5, 5, 10 et 15 L). Les temps de réponse de chaque sonde ainsi que le kLa dans les bioréacteurs ont aussi été évalués. Un système de contrôle en langage LABVIEW National Instruments, incluant une interface-usager numérique a été finalisé. Ce programme est capable de saisir, contrôler et surveiller les paramètres d'opération (pH, DO, pCO2, T) de huit bioréacteurs de façon simultanée et indépendante par le biais des modules de conversion Numériques/Analogues Field Point National Instruments. Finalement, le système a été testé par trois cultures de cellules HEK 293S dans les minibioréacteurs (100 et 300 mL). Les résultats ont été comparés à une culture statique dans un T-Flask de 25 cm2 . On a ainsi démontré que le système développé est robuste, précis et efficace.
78

Conditionnement de tiges de saule à l'aide d'un broyeur à marteaux

Gagnon-Bouchard, Michaël 16 April 2018 (has links)
Récemment, une récolteuse de plantes arbustives a été développée pour couper, broyer et mettre en balles rondes la biomasse, arbustive à un coût abordable. Afin d'optimiser le processus de broyage, un montage expérimental a été fabriqué. La composante principale était un rotor mesurant 1020 mm de long et 210 mm de diamètre et équipé de huit marteaux de 1,7 kg. Plusieurs paramètres pouvaient être ajustés, notamment la vitesse de rotation (de 1320 à 2390 TPM), la position du capot, celle du contre-couteau, le débit et la vitesse d'alimentation. Les résultats ont montré une demande d'énergie moyenne de broyage de 3,1 kJ/kg MS de saule. Une vitesse de rotation élevée (2390 TPM) a produit plus de particules inférieures à 250 mm (jusqu'à 580/0 de la masse totale) et aussi plus de perte (jusqu'à 17%). Une faible vitesse de rotation et un grand espacement entre les marteaux, le capot et le contre-couteau offraient un conditionnement acceptable pour la mise en balle, tout en réduisant les besoins en énergie et les pertes. / A recently developed cutter-shredder-baler successfully harvested willow over small areas at reasonable cost. To improve and optimize the shredding process, a laboratory-scale flail hammer type shredder was designed and built. The main rotor was 1020 mm in length and 210 mm in diameter. It was equipped with eight hammers of 1.7 kg. The rotary speed (from 1320 to 2390 rpm), the hood position, the counter-knife position, the crop fIow, and the feeding speed could be adjusted. Results indicated that shredding energy averaged 3.1 kJ/kg on a dry matter basis (DM) of processed willow. High rotary speed (2390 rpm) produced the largest quantity of small particles (up to 58% shorter than 250 mm) and also the highest level of loss during processing (up to 17%). A low flail rotary speed and a wide spacing between the flails, the hood and the counter-knife resulted in acceptable stem processing for subsequent baling while reducing energy requirement and DM loss.
79

Conception de préhenseurs sous-actionnés avec articulations déformables

Boudreault, Éric 11 April 2018 (has links)
En télémédecine aussi bien qu'en téléchirurgie, où les délais de communication entre l'opérateur et le patient sont trop importants pour percevoir le retour d'effort en temps réel, il est crucial de développer des outils intelligents autonomes capables de s'adapter aux changements locaux de géométrie et aux perturbations d'efforts. Dans ce mémoire, il est proposé de développer un nouveau préhenseur capable d'une prise autonome sur des objets de tout acabit. La pierre angulaire de ce nouveau préhenseur miniature est l'utilisation du sous-actionnement pour limiter le nombre d'actionneurs et l'utilisation d'articulations flexibles pour faciliter la miniaturisation du principe. Le bon fonctionnement du mécanisme repose sur une définition appropriée des critères de performance, sur un modèle mathématique juste et sur une optimisation adéquate.
80

Réduction de la Consommation Electrique du Contrôle-Commande des Machines Automatisées

Ligeret, Christophe 13 December 2010 (has links) (PDF)
Cette thèse présente une analyse de la consommation d'énergie des systèmes de contrôlecommande électriques des machines automatisées en vue de réduire leur consommation d'énergie. Il est notamment présenté les notions associées aux systèmes de contrôle-commande et il est développé des méthodes et un simulateur de consommation d'énergie destiné à l'analyse de la consommation d'énergie. A partir de ceci, il est réalisé une analyse selon 3 axes : consommation des composants de contrôlecommande pris individuellement, consommation des systèmes de contrôle-commande selon le type de machine et l'assemblage des composants et enfin, consommation dans le temps selon les modes de marche. Ces travaux mettent en évidence que la consommation des systèmes de contrôle-commande est souvent faible comparée à celle des actionneurs, mais qu'il est tout de même possible de réduire d'un facteur 2 la consommation d'énergie.

Page generated in 0.0369 seconds