• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • 3
  • Tagged with
  • 91
  • 89
  • 29
  • 21
  • 18
  • 18
  • 18
  • 18
  • 16
  • 13
  • 13
  • 12
  • 12
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Estudo da resistência, condutividade hidráulica e lixiviação de um solo argiloso cimentado e contaminado / Estúdio de la resistencia, condutividade hidráulica y lixiviacion de un suelo arcilloso cimentado y contaminado / Study of resistence, hydraulic conductivity and leaching of cemented and contaminated a clay soil

Jiménez Rojas, José Waldomiro January 2012 (has links)
Cada vez mais freqüente, a utilização de técnicas tradicionais da engenharia geotécnica depara-se com obstáculos de caráter econômico e ambiental. A técnica do solo-cimento tornase atrativa quando o melhoramento das propriedades do solo do local constitui-se em uma alternativa de projeto. A técnica de tratamento de solos com cimento encontra aplicação, por exemplo, na construção de bases para pavimentos, na proteção de taludes em barragens de terra, como camada de suporte para fundações superficiais, como remediação de solos contaminados e como barreiras de contenção de contaminantes. Desta forma, esta tese tem por objetivo analisar a influência da quantidade de cimento, da porosidade e da umidade de moldagem sobre o comportamento físico e químico de um solo argiloso artificialmente cimentado e contaminado. O programa experimental consiste em caracterizar os materiais utilizados, analisar fisicamente as misturas solo-cimento e solo-cimento-contaminante, através de ensaios de resistência à compressão simples, medidas de sucção e condutividade hidráulica. Quimicamente serão realizados ensaios de lixiviação em coluna e análises químicas e físico-químicas do lixiviado. Os resultados, quanto à caracterização, apresentam um material argiloso, oriundo de rochas riodacitos (riolito/dacito); quanto à resistência à compressão simples houve um aumento de resistência com o aumento da quantidade de cimento e com o aumento do peso especifico de compactação; quanto ao solo contaminado e cimentado ocorreu o mesmo comportamento, porém, com queda de resistência. A condutividade hidráulica obteve um decréscimo quando aumentado o peso especifico de moldagem, tanto para solo-cimento como para solo-cimento-contaminante. Para as análises químicas, a partir do ensaio de lixiviação, contatou-se redução de parâmetros de contaminação com a adição de cimento, principalmente com o aumento significativo do pH, devido ao aumento da quantidade de cimento. Concluiu-se que a quantidade de cimento e a diminuição da porosidade ocorrida pela maior densificação influenciam em ganho de resistência, à uma baixa permeabilidade e à uma baixa concentração de contaminante no lixiviado. / More and more the use of traditional techniques of the geotechnical engineering comes across obstacles of economic and environmental character. The technique of the soil-cement becomes attractive when the improvement of the properties of the local soil constituted in a project alternative. The technique of treatment of soils with cement finds application, for instance, in the construction of bases for pavements, in the protection of talus in land dams, as support layer for superficial foundations, as remediation of polluted soils and as barriers of contention of pollutants. This way, this theory has as objective to analyze the influence of the amount of cement, of the porosity and of the molding humidity over the physical and chemical behavior of a loamy soil artificially cemented and polluted. The experimental program consists of characterizing the used materials, to analyze the mixtures soil-cement and soil-cement-pollutant physically, through resistance samples to the simple compression, suction measures and hydraulic conductivity. The lixiviation samples will be chemically accomplished in column and chemical and physiochemical analyses of the lixiviated. The results, according to the characterization, present a loamy material, originating from rocks rhyodacite (rhyolite/dacite); according to the resistance to the simple compression there was a resistance increase with the rise of the amount of cement and with the increase of the weight specific of compaction; as for the polluted soil and cemented happened the same behavior, however, with resistance fall. The hydraulic conductivity suffered a decrease when increased the specific weight of molding, for soil-cement and for soil-cement-pollutant. (Continue For the chemical analyses, starting from the lixiviation samples, it was reached a reduction of parameters of contamination with the cement addition, mainly with the significant increase of the pH, due to the increase of the amount of cement. It was concluded that the amount of cement and the decrease of the porosity happened by the largest densification influence in resistance adding, as well as they provide a low permeability and a low pollutant concentration in the lixiviated. / Cada vez más la utilización de técnicas tradicionales de la ingeniería geotécnica se depara con obstáculos de carácter económico y ambiental. La técnica del suelo-cemento se vuelve atractiva cuando el mejoramiento de las propiedades del suelo local se constituye en una alternativa de proyecto. La técnica de tratamiento de suelos con cemento encuentra aplicación, por ejemplo, en la construcción de bases para pavimentos, en la protección de taludes, en presas de tierra, como camada de soporte para fundaciones superficiales, como remediación de suelos contaminados y como barreras de contención de contaminantes. Esta tesis tiene por objetivo analizar la influencia de la cantidad de cemento, de la porosidad y de la humedad del molde, sobre el comportamiento físico y químico de un suelo arcilloso artificialmente cementado y contaminado. El programa experimental consiste en caracterizar los materiales utilizados, analizar físicamente las mezclas suelo-cemento y suelo-cementocontaminante a través de ensayos de resistencia a compresión simple, medidas de succión y conductividad hidráulica. Químicamente serán realizados ensayos de lixiviación en columna y análisis químicos y físico-químicos del lixiviado. Los resultados, con respecto a la caracterización, presentan un material arcilloso, oriundo de rocas riodacitos (riolito/dacito). En cuanto a la resistencia el aumento de la misma es directamente proporcional al aumento de la cantidad de cemento y del peso especifico de compactación, referente al suelo contaminado y cementado ocurrió el mismo comportamiento, pero con disminución de resistencia. La conductividad hidráulica obtuvo una reducción cuando se produjo el aumento del peso específico, tanto para suelo-cemento como para suelo-cemento-contaminante. Para los análisis químicos, a partir del ensayo de lixiviación, se constato reducción de parámetros de contaminación con la adición de cemento, principalmente con el aumento significativo del pH. Se concluyó que la cantidad de cemento y la disminución de la porosidad ocurrida por l mayor compampactacion influencio en el aumento de resistencia, asi como porporciono baja permeabilidad y baja concentración de contaminante en el lixiviado.
82

Estimativa da resistência não drenada (Su) mediante o cálculo da energia de cravação do SPT / Estimating the undrained shear strength (Su) by calculating the energy of pile driving of the SPT / Estimativa de la resistencia no drenada (Su) mediante el cálculo de la energía de penetración del SPT

Muñoz Rodriguez, Camilo Andrés January 2012 (has links)
A presente dissertação tem por objetivo desenvolver um método para o cálculo da resistência não drenada (Su) através de uma metodologia que considera o cálculo da energia do ensaio SPT, partindo dos conceitos inicialmente propostos por Odebrecht (2003). Através de uma pesquisa bibliográfica foi gerado um banco de dados de estudos de casos executados em solos argilosos, em locais nos quais foram realizadas investigações geotécnicas extensivas, incluindo resultados de ensaios SPT e valores de Su obtidos através de outros ensaios de campo ou laboratório. Estes dados subsidiam a análise e formulação da proposta baseada em uma equação que combina o cálculo da energia desenvolvida durante o ensaio SPT à capacidade de carga estática por equilíbrio limite para uma estaca individual (proposta por Poulos e Davis, 1980). Foram definidas duas formas de calcular Su, diferenciadas pelo coeficiente de ajuste da força de atrito na capacidade de carga: α segundo proposta de Tomlinson (1969) e λ proposto por Vijayvergiya e Focht (1972). As formulações não produziram estimativas de Su compatíveis com valores medidos em outros ensaios e, por esta razão, foi proposta uma formulação alternativa para calcular α e λ como função direta do NSPT. Esta função é empírica e baseada em ajustes estatísticos. Dos processos de cálculo e avaliações conclui-se que o método proposto para a estimativa de α oferece resultados coerentes com os observados em ensaios de campo (piezocone e palheta). As estimativas de resistência não drenada apresentam considerável dispersão de resultados, com coeficiente de correlação médio r2 de 0,65. A dispersão é inerente a estimativas baseadas em ensaios SPT devido à diversidade de procedimentos usados na sua execução e, por este motivo, recomenda-se o uso destas correlações somente em nível de anteprojeto. / The present dissertation aims at developing a method for calculating the undrained shear strength Su using the methodology developed by Odebrecht’s (2003) based on the energy transmited by the SPT test. Through a bibliographic research, a database was created showing different case studies in clays in places where comprehensive geotechnical information is available. As a minimum requirement for selecting a case, the results of both the SPT test and the estimative of Su (from field or laboratory test) have to be registered. These results subsidized an analysis and the formulation of the proposed method, based on the equation that combines the theory for energy conservation to the static load capacity of a pile with the methodology of limit equilibrium analysis, suggested by Poulos and Davis (1980). Two different ways of calculating Su were defined. They were differentiated by the coefficient of adjustment of the frictional force: α as proposed by Tomlinson (1969) and λ by Vijayvergiya and Focht (1972). The formulations did not produce compatible estimates of Su with measureable values in other tests. For this reason a proposal was made to calculate both α and λ as a direct function of NSPT. This function is empirical and is based on statistical analysis. From the calculations, the proposed method of α is recommended based on the fact that it produces results that are comparable to those obtained from other field tests (piezocone and vane). The predicted values of undrained shear strength exhibit considerable dispersion of results, with an r2 correlation coefficient medium of 0.65. The dispersion is inherent to the estimates based on the tests of SPT due to the diversity of procedures/processes used in its execution and, for this motive, the use of these correlations are recommended only in preliminary projects. / La presente disertación tiene por objetivo desarrollar un método para el cálculo de la resistencia no drenada (Su) mediante una metodología que considera el cálculo de la energía del ensayo SPT, partiendo de los conceptos inicialmente propuestos por Odebrecht (2003). Mediante una investigación bibliográfica se generó un banco de datos de estudios realizados en suelos arcillosos, en locales donde fueron realizados investigaciones geotécnicas extensivas, incluyendo resultados de ensayos SPT y valores de Su obtenidos a través de otros ensayos de campo o laboratorio. Estos datos apoyan el análisis y la formulación de la propuesta basada en la ecuación que combina el cálculo de la energía desarrollada durante el ensayo SPT y la capacidad de carga estática por equilibrio límite para pilotes unitarios (propuesta por Poulos y Davis, 1980). Fueron definidas dos formas de calcular Su, diferenciadas por el coeficiente de ajuste de la fuerza de fricción en la capacidad de carga: α según propuesta de Tomlinson, 1969 y λ propuesto por Vijayvergiya y Focht, 1972. Estas formulaciones no produjeron estimativas de Su compatibles con valores medidos en otros ensayos y, es por esta razón que se propone una formulación alternativa para calcular α y λ como función directa del NSPT. Se trata de una función empírica basada en ajustes estadísticos. De los procesos de cálculo y evaluaciones realizados se concluye que el método propuesto para la estimativa de α ofrece resultados coherentes con los observados en ensayos de campo (piezocono y veleta). Las estimaciones de resistencia no drenada presentan una considerable dispersión de resultados, con coeficiente de correlación r2 del orden de 0,65. La dispersión es inherente a estimativas basadas en ensayos SPT debido a la diversidad de procedimientos usados para su ejecución, por este motivo se recomienda el uso de estas correlaciones solamente al nivel de anteproyecto.
83

Processos, fácies e geometria do sistema turbidítico da formação Taciba/Membro Rio Segredo, faixa aflorante norte catarinense

Andrade, Lygia Rodrigues de Moraes de [UNESP] 17 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:12Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-17Bitstream added on 2014-06-13T19:06:23Z : No. of bitstreams: 1 andrade_lrm_me_rcla.pdf: 1854084 bytes, checksum: 37c55097ff800285da56aac3723135e2 (MD5) / Os membros Lontras (Formação Campo Mourão) e Rio Segredo (Formação Taciba) constituem uma sucessão marinha de folhelhos e arenitos turbidíticos, que está encaixada entre diamictitos glaciais daquelas formações. O folhelho Lontras tem uma centena de metros na faixa aflorante norte catarinense, contendo em sua porção superior a fácies “folhelho várvico”, na verdade um estrato com gradação de siltito a folhelho (Tde) em escala milimétrica e que é considerado como sendo o turbidito distal da sucessão. O turbidito Rio Segredo tem de 15 a 25 m e consiste de estratos gradacionais portando sequência Bouma em diversas escalas: muito delgado (1 a 3 cm; Tde e Tcde), delgado (3 a 10 cm; Tcde e Tbcde), médio (10 a 30 cm; Tbcde e Tabcde), espesso (30 a 100 cm; Tabc) e muito espesso (acima de 1,0 m; Tabc). Há ainda uma divisão “superior” do Membro Rio Segredo normalmente com 10 a 20 m de espessura, que contém turbiditos areno-argilosos muito delgados (Tcde e Tde). Foram levantados sete perfis faciológicos de detalhe, escala 1:50, de modo a registrar turbiditos com até 5 cm de espessura (1 mm no perfil). Posteriormente, quatro desses perfis foram cronocorrelacionados em uma seção norte-sul: Forcação, Wiegand, Laeisz e Dona Emma, numa extensão de 28 km. A esta seção foi acrescido o perfil Taiózinho, localizado 30 km a oeste do Forcação, entre os dois últimos (semelhança faciológica com o Laeisz). Identificaram-se sete sistemas deposicionais, com uma média de 3 m de espessura por sistema e contidos em três sequências de alta frequência. Os sistemas deposicionais são formados por ciclos turbidíticos de origem marinha, encontrados principalmente nos perfis Laeisz e Taiózinho, com uma organização ascendente de adelgaçamento e granodecrescência. Outros ciclos turbidíticos... / The Lontras shale and overlying Rio Segredo sandstone are members of Campo Mourão and Taciba formations, corresponding to shelf marine and turbidite deposits; they are encased in glacial diamictites of those formations. The Lontras shale is 100 m thick in northern Santa Catarina outcrop belt and it displays a “varved shale” facies in its upper portion. In reality, it represents many mm-scale beds with Bouma sequence Tde, and therefore distal, argillaceous turbidites. The Rio Segredo Member is 15 to 25 m thick and contain beds of different thicknesses: very thin (1 to 3 cm; Tde and Tcde), thin (3 to 10 cm; Tcde and Tbcde), and medium beds (10 to 30 cm; Tbcde and Tabcde). Also, thick (30 to 100 cm) and very thick beds (thicker than 1 m) displays massive or graded sandstones with disperse laminations and cross-laminations resembling Ta, Tb and Tc intervals of Bouma sequence. There is also a Rio Segredo “upper” division with 10 to 20 m thick, consisting of very thin turbidites (Tcde and Tde). Seven detailed facies logs were constructed at 1:50 scale, to represent even 5 cm thin beds (1 mm). Later, four of the logs were put in a north-south stratigraphic section (28 km in length): Forcação, Wiegand, Laeisz and Dona Emma, in a 28 km extension. A fifth log, Taiózinho (distant 30 km west of Forcação), was added to the section between the last two logs, because of its facies similarity with Laeisz log. Seven depositional systems are identified, averaging 3 m thick in, thickness, and they belong to high frequency sequences. The systems are composed of turbidite cycles of marine origin, found mainly in Laeisz and Taiózinho logs: they form thinning- and fining-upward cycles. Turbidite cycles of deltaic origin are observed in Forcação and Dona Emma logs as thickening-up and coarsening-up cycles. In the latter, are included... (Complete abstract click electronic access below)
84

Caracterização geotécnica da sensibilidade de um depósito sedimentar do Rio Grande do Sul com o uso de ensaios de laboratório

Bertuol, Fábio January 2009 (has links)
Um dos maiores problemas na utilização de ensaios geotécnicos de laboratório está na obtenção de amostras indeformadas. Os solos moles estão entre os mais difíceis de amostrar e há um grande trabalho de pesquisa no desenvolvimento de técnicas de amostragem. A fim de obter amostras de alta qualidade para o estudo do comportamento do material do depósito, foi desenvolvido nesta pesquisa uma modificação do Equipamento de Amostragem Japonês e foram adaptadas algumas das técnicas utilizadas para amostragem indeformada. O processo usual de extrusão de solo de dentro do tubo amostrador foi substituído pelo corte transversal do tubo, o que reduz a perturbação do solo. Para facilitar esta operação, os tubos foram construídos de latão (substituindo o aço inoxidável original). O depósito sedimentar objeto de estudo desta dissertação foi escolhido por ter apresentado em ensaios de campo um índice de sensibilidade (razão entre as resistências ao cisalhamento não drenadas indeformada e amolgada) bastante elevado, o que torna a sua amostragem cuidadosa ainda mais importante. A sensibilidade dos solos é um parâmetro importante em projetos de engenharia geotécnica, pois as deformações reduzem severamente a resistência ao cisalhamento não drenada nestes materiais. Foram utilizados diferentes ensaios de laboratório para permitir a determinação da resistência ao cisalhamento não-drenada do solo nas condições indeformada e amolgada, e para avaliação da sensibilidade (ensaio de cone de laboratório, ensaio de palheta de laboratório e ensaio triaxial), além de ensaios de caracterização do depósito. O depósito estudado apresenta lentes com dois materiais distintos (um argiloso e outro arenoso), entretanto apresentam ângulos de atrito interno semelhantes (~34°). Em ambos o solos as resistências ao cisalhamento não drenada foram baixas (Su ~10 kPa na condição indeformada e Su = 0,5 - 2,0 kPa na condição amolgada). A sensibilidade do material argiloso ficou em torno de 10 e no solo arenoso foi de aproximadamente 20. Análises qualitativas dos resultados indicam que as amostras coletadas pelo novo amostrador tiveram elevado grau de qualidade. Os resultados obtidos (a) confirmam o bom desempenho do novo equipamento amostrador; (b) permitiram determinar com precisão as resistências não-drenadas dos materiais; (c) comprovaram a grande sensibilidade das lentes arenosas; (d) ajudam a explicar o comportamento do depósito em campo. / One of the most difficult problems in the use of laboratory geotechnical tests is related to obtaining undisturbed samples. The soft soils are among the most difficult soils to sample and there is a great research effort in developing new sampling techniques. In order to obtain high quality samples for the study of the soil sensitivity, a modification of the Japanese thin-walled tube sampler has been build for this research and some modifications of the sampling techniques have been made. The conventional extrusion of the soil sample from the tube was substituted by a traverse cut of the tube in order to reduce the soil perturbation during its extraction. To make this operation easier, the material used for the tubes was brass (substituting the usual stainless steel). The sedimentary deposit studied on this research has been selected for having presented an high sensitivity on vane field tests (relation between peak and large deformation strengths) which gives even more importance to careful sampling. The sensitivity is an important parameter for geotechnical design as the deformations can severely reduce the undrained shear strength of these materials. Various laboratory testing techniques have been used to determine the undrained shear strength of these soils both in undisturbed and disturbed conditions (fall cone tests, lab vane tests and triaxial tests), besides characterization tests of the deposit. The studied deposit presents lenses of two distinct materials (clayey and sandy lenses), however they present similar internal angles of friction (~34°). In both soils the undrained shear strength are quite low (Su ~10 kPa in undisturbed condition and Su = 0,5 - 2,0 kPa in disturbed condition). The sensitivity of the clayey material is around 10 and around 20 in the sandy soil. Qualitative analyses of the results indicate that the samples taken with the new sampler have an high quality level. The results obtained (a) confirm the good performance of the sampler built; (b) allowed the undrained shear strength to be determined with precision; (c) showed the great sensitivity of the sandy lenses; (d) helped to explain the field behaviour of the soil.
85

Estudo em Escala Piloto de Parâmetros de Monitoramento e Operação de Biopilhas no Tratamento de Solos Contaminados por Hidrocarbonetos de Petróleo / Operational parameters of biopiles sistems for the treatment of soils contaminated by petroleum hydrocarbons

Jorge Antônio Lopes 12 December 2012 (has links)
O objetivo do trabalho foi identificar ferramentas e indicadores adequados ao monitoramento e à otimização de processos de biorremediação, incluindo parâmetros físicos, químicos e microbiológicos definidos em estudos de tratabilidade de solos contaminados por óleo cru em escala de laboratório e comparar estratégias de biorremediação, tais como bioestímulo e bioaumento conduzidas em simulações de biopilhas dinâmicas ou estáticas. Quando três métodos de extração de hidrocarbonetos de petróleo de solo arenoso e franco-argiloso para análise cromatográfica (Soxhlet-SOX, microondas-MARS e extração acelerada por solvente-ASE) foram comparados entre si, concluiu-se que a técnica que promove a melhor recuperação depende da fração de interesse (n-alcanos, HRP, MCNR, HPA), das características texturais do solo (teores de areia, silte e argila) e da idade da contaminação. Dentre os indicadores de densidade populacional microbiana (microrganismos heterotróficos totais-PHT, população de fungos-PF e população microbiana degradadora de óleo (PDO) passíveis de utilização para indicar a taxa de degradação de compostos orgânicos presentes no solo tais como os hidrocarbonetos de petróleo, o PDO mostrou-se o mais adequado em conjunto com a produção de CO2 aferida pelo método respirométrico. Quando a estratégia de biorremediação de solo franco-argiloso contaminado com óleo cru a 3% (m m-1) utilizando bioestímulo (ajuste de pH, umidade e taxa C:N:P) foi comparada ao bioaumento (bioestímulo e adição de inóculo de microrganismos extraídos, enriquecidos e aclimatizados ao óleo cru como fonte de carbono), em sistemas de bancada simulando biopilha dinâmica (microcosmo M) e biopilha estática com aeração forçada (reator B), o tratamento que apresentou melhor remoção (32%) de HTP após 121 dias foi o bioaumento em biopilha estática. Para HPA, o tratamento que alcançou a melhor remoção (33%) foi com bioestímulo também em biopilha estática. A avaliação da taxa de mortalidade (%) de Eisenia andrei exposta tanto a solos recém-contaminados por óleo cru e preparados para bioestímulo (BIOS) e bioaumento (BIOA) a serem tratados em biopilhas dinâmicas e estáticas em escala de laboratório mostrou que após 56 dias de exposição da E. andrei, todos os solos produziram letalidade de 100%, quer fossem os solos recém-contaminados e preparados para os diferentes tratamentos (BIOS M, BIOS B, BIOA M, BIOA B) ou após 121 dias de tratamento. Tal resultado confirma que a biorremediação foi incipiente também do ponto de vista de remoção da ecotoxicidade. Em linhas gerais, a biorremediação de solo franco-argiloso contaminado por óleo cru, contendo tanto contaminação antiga quanto recente, reúne os maiores desafios à biorremediação, tanto do ponto de vista da composição textural do solo quanto da natureza do contaminante. Os processos são aparentemente lentos e requerem ferramentas auxiliares para aceleração dos mesmos. Recomenda-se no futuro, condução de experimentos com o uso de diferentes surfactantes, com ênfase em biosurfactantes / The objective of this investigation was to identify tools and indicators suitable for monitoring and optimizing bioremediation processes, including physical, chemical and microbiological variables defined in treatability studies of crude oil contaminated clayey soils in lab-scale and to compare bioremediation strategies, such as biostimulation and bioaugmentation carried out in lab scale dynamics and static biopiles. When three methods for extraction of petroleum hydrocarbon for chromatography analysis (Soxhlet-SOX, microwaves-MARS and accelerated solvent extraction-ASE) were compared, it was concluded that the most appropriate extraction method depends on the hydrocarbon fraction of interest (n-alkanes, RPH, UCM or PAH), the textural soil characteristics (sand, silt and clay content) and the contamination age. Among the microbiological indicators investigated (total heterotrophic microorganisms-PHT, fungi population-PF and; oil-degrading microorganism population-PDO, the last one was the best indicator for degradation of organic carbon compounds such as petroleum hydrocarbon, together with CO2 generation measured through respirometric method. Bioremediation strategies for oil-contaminated clayey soil (3% m m-1) were compared, including biostimulation (adjustment of pH, C:N:P rate and moisture) and bioaugmentation (biostimulation plus a consortium inoculum extracted from the original aged-contaminated soil, enriched and acclimatized with the crude oil as carbon source) in lab scale system simulating dynamic (microcosms) and static (bioreactors with forced aeration). The treatment which presented the highest TPH removal (32%) after 121 days was the bioaugmented static biopile (BIOA B). For PAH, the most efficient treatment method that removed 33% of PAH was the biostimulated static biopile (BIOS B). The mortality rate (%) for Eisenia andrei exposed to newly contaminated soil prepared for biostimulation (BIOS) and bioaugmentation (BIOA) treatments at day 0 as well as the treated soil in static and dynamic biopiles at different treatment times (after 24, 59 and 121 days) revealed that after 56 of E. andreis exposition, all soils produced mortality of 100%, no matter if newly contaminated or treated (BIOS M, BIOS B, BIOA M, BIOA B). The ecotoxicity tests confirmed that bioremediation as such was incipient also from the toxicity removal viewpoint. In general terms, bioremediation of clayey soils with a complex contaminant such as crude oil raise considerable challenges, both from the soil characteristics as well as the nature of the contaminant. The processes are apparently slow and require auxiliary tools to speed up the process. In the future, it is recommended to test the use of different surfactants, particularly bio-surfactants.
86

Estudo da resistência, condutividade hidráulica e lixiviação de um solo argiloso cimentado e contaminado / Estúdio de la resistencia, condutividade hidráulica y lixiviacion de un suelo arcilloso cimentado y contaminado / Study of resistence, hydraulic conductivity and leaching of cemented and contaminated a clay soil

Jiménez Rojas, José Waldomiro January 2012 (has links)
Cada vez mais freqüente, a utilização de técnicas tradicionais da engenharia geotécnica depara-se com obstáculos de caráter econômico e ambiental. A técnica do solo-cimento tornase atrativa quando o melhoramento das propriedades do solo do local constitui-se em uma alternativa de projeto. A técnica de tratamento de solos com cimento encontra aplicação, por exemplo, na construção de bases para pavimentos, na proteção de taludes em barragens de terra, como camada de suporte para fundações superficiais, como remediação de solos contaminados e como barreiras de contenção de contaminantes. Desta forma, esta tese tem por objetivo analisar a influência da quantidade de cimento, da porosidade e da umidade de moldagem sobre o comportamento físico e químico de um solo argiloso artificialmente cimentado e contaminado. O programa experimental consiste em caracterizar os materiais utilizados, analisar fisicamente as misturas solo-cimento e solo-cimento-contaminante, através de ensaios de resistência à compressão simples, medidas de sucção e condutividade hidráulica. Quimicamente serão realizados ensaios de lixiviação em coluna e análises químicas e físico-químicas do lixiviado. Os resultados, quanto à caracterização, apresentam um material argiloso, oriundo de rochas riodacitos (riolito/dacito); quanto à resistência à compressão simples houve um aumento de resistência com o aumento da quantidade de cimento e com o aumento do peso especifico de compactação; quanto ao solo contaminado e cimentado ocorreu o mesmo comportamento, porém, com queda de resistência. A condutividade hidráulica obteve um decréscimo quando aumentado o peso especifico de moldagem, tanto para solo-cimento como para solo-cimento-contaminante. Para as análises químicas, a partir do ensaio de lixiviação, contatou-se redução de parâmetros de contaminação com a adição de cimento, principalmente com o aumento significativo do pH, devido ao aumento da quantidade de cimento. Concluiu-se que a quantidade de cimento e a diminuição da porosidade ocorrida pela maior densificação influenciam em ganho de resistência, à uma baixa permeabilidade e à uma baixa concentração de contaminante no lixiviado. / More and more the use of traditional techniques of the geotechnical engineering comes across obstacles of economic and environmental character. The technique of the soil-cement becomes attractive when the improvement of the properties of the local soil constituted in a project alternative. The technique of treatment of soils with cement finds application, for instance, in the construction of bases for pavements, in the protection of talus in land dams, as support layer for superficial foundations, as remediation of polluted soils and as barriers of contention of pollutants. This way, this theory has as objective to analyze the influence of the amount of cement, of the porosity and of the molding humidity over the physical and chemical behavior of a loamy soil artificially cemented and polluted. The experimental program consists of characterizing the used materials, to analyze the mixtures soil-cement and soil-cement-pollutant physically, through resistance samples to the simple compression, suction measures and hydraulic conductivity. The lixiviation samples will be chemically accomplished in column and chemical and physiochemical analyses of the lixiviated. The results, according to the characterization, present a loamy material, originating from rocks rhyodacite (rhyolite/dacite); according to the resistance to the simple compression there was a resistance increase with the rise of the amount of cement and with the increase of the weight specific of compaction; as for the polluted soil and cemented happened the same behavior, however, with resistance fall. The hydraulic conductivity suffered a decrease when increased the specific weight of molding, for soil-cement and for soil-cement-pollutant. (Continue For the chemical analyses, starting from the lixiviation samples, it was reached a reduction of parameters of contamination with the cement addition, mainly with the significant increase of the pH, due to the increase of the amount of cement. It was concluded that the amount of cement and the decrease of the porosity happened by the largest densification influence in resistance adding, as well as they provide a low permeability and a low pollutant concentration in the lixiviated. / Cada vez más la utilización de técnicas tradicionales de la ingeniería geotécnica se depara con obstáculos de carácter económico y ambiental. La técnica del suelo-cemento se vuelve atractiva cuando el mejoramiento de las propiedades del suelo local se constituye en una alternativa de proyecto. La técnica de tratamiento de suelos con cemento encuentra aplicación, por ejemplo, en la construcción de bases para pavimentos, en la protección de taludes, en presas de tierra, como camada de soporte para fundaciones superficiales, como remediación de suelos contaminados y como barreras de contención de contaminantes. Esta tesis tiene por objetivo analizar la influencia de la cantidad de cemento, de la porosidad y de la humedad del molde, sobre el comportamiento físico y químico de un suelo arcilloso artificialmente cementado y contaminado. El programa experimental consiste en caracterizar los materiales utilizados, analizar físicamente las mezclas suelo-cemento y suelo-cementocontaminante a través de ensayos de resistencia a compresión simple, medidas de succión y conductividad hidráulica. Químicamente serán realizados ensayos de lixiviación en columna y análisis químicos y físico-químicos del lixiviado. Los resultados, con respecto a la caracterización, presentan un material arcilloso, oriundo de rocas riodacitos (riolito/dacito). En cuanto a la resistencia el aumento de la misma es directamente proporcional al aumento de la cantidad de cemento y del peso especifico de compactación, referente al suelo contaminado y cementado ocurrió el mismo comportamiento, pero con disminución de resistencia. La conductividad hidráulica obtuvo una reducción cuando se produjo el aumento del peso específico, tanto para suelo-cemento como para suelo-cemento-contaminante. Para los análisis químicos, a partir del ensayo de lixiviación, se constato reducción de parámetros de contaminación con la adición de cemento, principalmente con el aumento significativo del pH. Se concluyó que la cantidad de cemento y la disminución de la porosidad ocurrida por l mayor compampactacion influencio en el aumento de resistencia, asi como porporciono baja permeabilidad y baja concentración de contaminante en el lixiviado.
87

Estimativa da resistência não drenada (Su) mediante o cálculo da energia de cravação do SPT / Estimating the undrained shear strength (Su) by calculating the energy of pile driving of the SPT / Estimativa de la resistencia no drenada (Su) mediante el cálculo de la energía de penetración del SPT

Muñoz Rodriguez, Camilo Andrés January 2012 (has links)
A presente dissertação tem por objetivo desenvolver um método para o cálculo da resistência não drenada (Su) através de uma metodologia que considera o cálculo da energia do ensaio SPT, partindo dos conceitos inicialmente propostos por Odebrecht (2003). Através de uma pesquisa bibliográfica foi gerado um banco de dados de estudos de casos executados em solos argilosos, em locais nos quais foram realizadas investigações geotécnicas extensivas, incluindo resultados de ensaios SPT e valores de Su obtidos através de outros ensaios de campo ou laboratório. Estes dados subsidiam a análise e formulação da proposta baseada em uma equação que combina o cálculo da energia desenvolvida durante o ensaio SPT à capacidade de carga estática por equilíbrio limite para uma estaca individual (proposta por Poulos e Davis, 1980). Foram definidas duas formas de calcular Su, diferenciadas pelo coeficiente de ajuste da força de atrito na capacidade de carga: α segundo proposta de Tomlinson (1969) e λ proposto por Vijayvergiya e Focht (1972). As formulações não produziram estimativas de Su compatíveis com valores medidos em outros ensaios e, por esta razão, foi proposta uma formulação alternativa para calcular α e λ como função direta do NSPT. Esta função é empírica e baseada em ajustes estatísticos. Dos processos de cálculo e avaliações conclui-se que o método proposto para a estimativa de α oferece resultados coerentes com os observados em ensaios de campo (piezocone e palheta). As estimativas de resistência não drenada apresentam considerável dispersão de resultados, com coeficiente de correlação médio r2 de 0,65. A dispersão é inerente a estimativas baseadas em ensaios SPT devido à diversidade de procedimentos usados na sua execução e, por este motivo, recomenda-se o uso destas correlações somente em nível de anteprojeto. / The present dissertation aims at developing a method for calculating the undrained shear strength Su using the methodology developed by Odebrecht’s (2003) based on the energy transmited by the SPT test. Through a bibliographic research, a database was created showing different case studies in clays in places where comprehensive geotechnical information is available. As a minimum requirement for selecting a case, the results of both the SPT test and the estimative of Su (from field or laboratory test) have to be registered. These results subsidized an analysis and the formulation of the proposed method, based on the equation that combines the theory for energy conservation to the static load capacity of a pile with the methodology of limit equilibrium analysis, suggested by Poulos and Davis (1980). Two different ways of calculating Su were defined. They were differentiated by the coefficient of adjustment of the frictional force: α as proposed by Tomlinson (1969) and λ by Vijayvergiya and Focht (1972). The formulations did not produce compatible estimates of Su with measureable values in other tests. For this reason a proposal was made to calculate both α and λ as a direct function of NSPT. This function is empirical and is based on statistical analysis. From the calculations, the proposed method of α is recommended based on the fact that it produces results that are comparable to those obtained from other field tests (piezocone and vane). The predicted values of undrained shear strength exhibit considerable dispersion of results, with an r2 correlation coefficient medium of 0.65. The dispersion is inherent to the estimates based on the tests of SPT due to the diversity of procedures/processes used in its execution and, for this motive, the use of these correlations are recommended only in preliminary projects. / La presente disertación tiene por objetivo desarrollar un método para el cálculo de la resistencia no drenada (Su) mediante una metodología que considera el cálculo de la energía del ensayo SPT, partiendo de los conceptos inicialmente propuestos por Odebrecht (2003). Mediante una investigación bibliográfica se generó un banco de datos de estudios realizados en suelos arcillosos, en locales donde fueron realizados investigaciones geotécnicas extensivas, incluyendo resultados de ensayos SPT y valores de Su obtenidos a través de otros ensayos de campo o laboratorio. Estos datos apoyan el análisis y la formulación de la propuesta basada en la ecuación que combina el cálculo de la energía desarrollada durante el ensayo SPT y la capacidad de carga estática por equilibrio límite para pilotes unitarios (propuesta por Poulos y Davis, 1980). Fueron definidas dos formas de calcular Su, diferenciadas por el coeficiente de ajuste de la fuerza de fricción en la capacidad de carga: α según propuesta de Tomlinson, 1969 y λ propuesto por Vijayvergiya y Focht, 1972. Estas formulaciones no produjeron estimativas de Su compatibles con valores medidos en otros ensayos y, es por esta razón que se propone una formulación alternativa para calcular α y λ como función directa del NSPT. Se trata de una función empírica basada en ajustes estadísticos. De los procesos de cálculo y evaluaciones realizados se concluye que el método propuesto para la estimativa de α ofrece resultados coherentes con los observados en ensayos de campo (piezocono y veleta). Las estimaciones de resistencia no drenada presentan una considerable dispersión de resultados, con coeficiente de correlación r2 del orden de 0,65. La dispersión es inherente a estimativas basadas en ensayos SPT debido a la diversidad de procedimientos usados para su ejecución, por este motivo se recomienda el uso de estas correlaciones solamente al nivel de anteproyecto.
88

Caracterização geotécnica da sensibilidade de um depósito sedimentar do Rio Grande do Sul com o uso de ensaios de laboratório

Bertuol, Fábio January 2009 (has links)
Um dos maiores problemas na utilização de ensaios geotécnicos de laboratório está na obtenção de amostras indeformadas. Os solos moles estão entre os mais difíceis de amostrar e há um grande trabalho de pesquisa no desenvolvimento de técnicas de amostragem. A fim de obter amostras de alta qualidade para o estudo do comportamento do material do depósito, foi desenvolvido nesta pesquisa uma modificação do Equipamento de Amostragem Japonês e foram adaptadas algumas das técnicas utilizadas para amostragem indeformada. O processo usual de extrusão de solo de dentro do tubo amostrador foi substituído pelo corte transversal do tubo, o que reduz a perturbação do solo. Para facilitar esta operação, os tubos foram construídos de latão (substituindo o aço inoxidável original). O depósito sedimentar objeto de estudo desta dissertação foi escolhido por ter apresentado em ensaios de campo um índice de sensibilidade (razão entre as resistências ao cisalhamento não drenadas indeformada e amolgada) bastante elevado, o que torna a sua amostragem cuidadosa ainda mais importante. A sensibilidade dos solos é um parâmetro importante em projetos de engenharia geotécnica, pois as deformações reduzem severamente a resistência ao cisalhamento não drenada nestes materiais. Foram utilizados diferentes ensaios de laboratório para permitir a determinação da resistência ao cisalhamento não-drenada do solo nas condições indeformada e amolgada, e para avaliação da sensibilidade (ensaio de cone de laboratório, ensaio de palheta de laboratório e ensaio triaxial), além de ensaios de caracterização do depósito. O depósito estudado apresenta lentes com dois materiais distintos (um argiloso e outro arenoso), entretanto apresentam ângulos de atrito interno semelhantes (~34°). Em ambos o solos as resistências ao cisalhamento não drenada foram baixas (Su ~10 kPa na condição indeformada e Su = 0,5 - 2,0 kPa na condição amolgada). A sensibilidade do material argiloso ficou em torno de 10 e no solo arenoso foi de aproximadamente 20. Análises qualitativas dos resultados indicam que as amostras coletadas pelo novo amostrador tiveram elevado grau de qualidade. Os resultados obtidos (a) confirmam o bom desempenho do novo equipamento amostrador; (b) permitiram determinar com precisão as resistências não-drenadas dos materiais; (c) comprovaram a grande sensibilidade das lentes arenosas; (d) ajudam a explicar o comportamento do depósito em campo. / One of the most difficult problems in the use of laboratory geotechnical tests is related to obtaining undisturbed samples. The soft soils are among the most difficult soils to sample and there is a great research effort in developing new sampling techniques. In order to obtain high quality samples for the study of the soil sensitivity, a modification of the Japanese thin-walled tube sampler has been build for this research and some modifications of the sampling techniques have been made. The conventional extrusion of the soil sample from the tube was substituted by a traverse cut of the tube in order to reduce the soil perturbation during its extraction. To make this operation easier, the material used for the tubes was brass (substituting the usual stainless steel). The sedimentary deposit studied on this research has been selected for having presented an high sensitivity on vane field tests (relation between peak and large deformation strengths) which gives even more importance to careful sampling. The sensitivity is an important parameter for geotechnical design as the deformations can severely reduce the undrained shear strength of these materials. Various laboratory testing techniques have been used to determine the undrained shear strength of these soils both in undisturbed and disturbed conditions (fall cone tests, lab vane tests and triaxial tests), besides characterization tests of the deposit. The studied deposit presents lenses of two distinct materials (clayey and sandy lenses), however they present similar internal angles of friction (~34°). In both soils the undrained shear strength are quite low (Su ~10 kPa in undisturbed condition and Su = 0,5 - 2,0 kPa in disturbed condition). The sensitivity of the clayey material is around 10 and around 20 in the sandy soil. Qualitative analyses of the results indicate that the samples taken with the new sampler have an high quality level. The results obtained (a) confirm the good performance of the sampler built; (b) allowed the undrained shear strength to be determined with precision; (c) showed the great sensitivity of the sandy lenses; (d) helped to explain the field behaviour of the soil.
89

Estimativa da resistência não drenada (Su) mediante o cálculo da energia de cravação do SPT / Estimating the undrained shear strength (Su) by calculating the energy of pile driving of the SPT / Estimativa de la resistencia no drenada (Su) mediante el cálculo de la energía de penetración del SPT

Muñoz Rodriguez, Camilo Andrés January 2012 (has links)
A presente dissertação tem por objetivo desenvolver um método para o cálculo da resistência não drenada (Su) através de uma metodologia que considera o cálculo da energia do ensaio SPT, partindo dos conceitos inicialmente propostos por Odebrecht (2003). Através de uma pesquisa bibliográfica foi gerado um banco de dados de estudos de casos executados em solos argilosos, em locais nos quais foram realizadas investigações geotécnicas extensivas, incluindo resultados de ensaios SPT e valores de Su obtidos através de outros ensaios de campo ou laboratório. Estes dados subsidiam a análise e formulação da proposta baseada em uma equação que combina o cálculo da energia desenvolvida durante o ensaio SPT à capacidade de carga estática por equilíbrio limite para uma estaca individual (proposta por Poulos e Davis, 1980). Foram definidas duas formas de calcular Su, diferenciadas pelo coeficiente de ajuste da força de atrito na capacidade de carga: α segundo proposta de Tomlinson (1969) e λ proposto por Vijayvergiya e Focht (1972). As formulações não produziram estimativas de Su compatíveis com valores medidos em outros ensaios e, por esta razão, foi proposta uma formulação alternativa para calcular α e λ como função direta do NSPT. Esta função é empírica e baseada em ajustes estatísticos. Dos processos de cálculo e avaliações conclui-se que o método proposto para a estimativa de α oferece resultados coerentes com os observados em ensaios de campo (piezocone e palheta). As estimativas de resistência não drenada apresentam considerável dispersão de resultados, com coeficiente de correlação médio r2 de 0,65. A dispersão é inerente a estimativas baseadas em ensaios SPT devido à diversidade de procedimentos usados na sua execução e, por este motivo, recomenda-se o uso destas correlações somente em nível de anteprojeto. / The present dissertation aims at developing a method for calculating the undrained shear strength Su using the methodology developed by Odebrecht’s (2003) based on the energy transmited by the SPT test. Through a bibliographic research, a database was created showing different case studies in clays in places where comprehensive geotechnical information is available. As a minimum requirement for selecting a case, the results of both the SPT test and the estimative of Su (from field or laboratory test) have to be registered. These results subsidized an analysis and the formulation of the proposed method, based on the equation that combines the theory for energy conservation to the static load capacity of a pile with the methodology of limit equilibrium analysis, suggested by Poulos and Davis (1980). Two different ways of calculating Su were defined. They were differentiated by the coefficient of adjustment of the frictional force: α as proposed by Tomlinson (1969) and λ by Vijayvergiya and Focht (1972). The formulations did not produce compatible estimates of Su with measureable values in other tests. For this reason a proposal was made to calculate both α and λ as a direct function of NSPT. This function is empirical and is based on statistical analysis. From the calculations, the proposed method of α is recommended based on the fact that it produces results that are comparable to those obtained from other field tests (piezocone and vane). The predicted values of undrained shear strength exhibit considerable dispersion of results, with an r2 correlation coefficient medium of 0.65. The dispersion is inherent to the estimates based on the tests of SPT due to the diversity of procedures/processes used in its execution and, for this motive, the use of these correlations are recommended only in preliminary projects. / La presente disertación tiene por objetivo desarrollar un método para el cálculo de la resistencia no drenada (Su) mediante una metodología que considera el cálculo de la energía del ensayo SPT, partiendo de los conceptos inicialmente propuestos por Odebrecht (2003). Mediante una investigación bibliográfica se generó un banco de datos de estudios realizados en suelos arcillosos, en locales donde fueron realizados investigaciones geotécnicas extensivas, incluyendo resultados de ensayos SPT y valores de Su obtenidos a través de otros ensayos de campo o laboratorio. Estos datos apoyan el análisis y la formulación de la propuesta basada en la ecuación que combina el cálculo de la energía desarrollada durante el ensayo SPT y la capacidad de carga estática por equilibrio límite para pilotes unitarios (propuesta por Poulos y Davis, 1980). Fueron definidas dos formas de calcular Su, diferenciadas por el coeficiente de ajuste de la fuerza de fricción en la capacidad de carga: α según propuesta de Tomlinson, 1969 y λ propuesto por Vijayvergiya y Focht, 1972. Estas formulaciones no produjeron estimativas de Su compatibles con valores medidos en otros ensayos y, es por esta razón que se propone una formulación alternativa para calcular α y λ como función directa del NSPT. Se trata de una función empírica basada en ajustes estadísticos. De los procesos de cálculo y evaluaciones realizados se concluye que el método propuesto para la estimativa de α ofrece resultados coherentes con los observados en ensayos de campo (piezocono y veleta). Las estimaciones de resistencia no drenada presentan una considerable dispersión de resultados, con coeficiente de correlación r2 del orden de 0,65. La dispersión es inherente a estimativas basadas en ensayos SPT debido a la diversidad de procedimientos usados para su ejecución, por este motivo se recomienda el uso de estas correlaciones solamente al nivel de anteproyecto.
90

Construção e avaliação de hidrociclone para pré-filtragem da água de irrigação. / Construction and evaluation of hydrocyclone for pre-filtering irrigation water.

Olivio José Soccol 28 February 2003 (has links)
Na agricultura irrigada, a qualidade da água utilizada é de fundamental importância para o perfeito funcionamento dos sistemas de irrigação e de seus componentes. A utilização de água contendo sedimentos em suspensão tem sido a causa de sérios problemas em sistemas de irrigação, reduzindo a vida útil de seus componentes, promovendo o entupimento de tubulações e emissores, ocasionando como conseqüência, irrigações não uniformes e queda na eficiência dos mesmos. A escolha do tipo e capacidade do sistema de filtragem é de fundamental importância, evitando-se assim, aumento nos custos de operação e manutenção do sistema de irrigação, devido a necessidade de limpeza e trocas freqüentes de seus componentes. Pré-filtros, como os hidrociclones, desempenham importante papel, pois se caracterizam por significativo poder de separação de partículas, maiores do que 100 mm, presentes na água; mantendo constante a perda de carga ao longo do tempo, o que não ocorre com os outros tipos de filtros normalmente utilizados nos sistemas de irrigação. Apesar de algumas referências feitas aos hidrociclones em literatura internacional, não se dispõe, no Brasil, de dados do desempenho dos hidrociclones, quando empregados em pré-filtragem da água utilizada nos sistemas de irrigação. Assim, um experimento conduzido no Laboratório de Hidráulica do Departamento de Engenharia Rural da ESALQ/USP, compreendeu a construção de quatro hidrociclones do tipo Rietema, com diâmetro de 50 mm, um com bocal de alimentação circular e os demais com bocais de seção retangular, cujas seções foram decrescentes. A avaliação do desempenho dos mesmos foi realizada utilizando-se suspensões de areia fina e solo argiloso, sob diferentes diferenciais de pressão, adotando-se como critério de comparação, a capacidade de vazão e o poder de separação, medido pela eficiência total e eficiência total reduzida. Os resultados obtidos mostraram que o hidrociclone dotado com bocal de alimentação circular apresentou os maiores índices nos critérios de comparação, tanto para a suspensão de areia, quanto para a de solo. / Good water quality is uppermost in irrigated agriculture for the perfect functioning of irrigation systems and their components. The use of water containing suspended sediments has caused serious problems to irrigation systems, reducing the useful life of their components, clogging pipes and emitters, consequently causing non-uniform irrigations and low efficiency. Choosing the right filtering system type and capacity is essential to avoid increases in operational and maintenance costs of irrigation systems due to the need for cleaning and frequent replacing of their components. Pre-filters, such as hydrocyclones, are important for their significant capability to retain particles larger than 100 mm present in water, keeping the head loss constant with the time, unlike other filters normally used in irrigation systems. Despite being present in the international literature, data on the performance of hydrocyclones used for pre-filtering irrigation water in Brazil are not available. Therefore, four Rietema type hydrocyclones (50 mm diameter) were construction in the Hydraulics Laboratory of the Rural Engineering Department – ESALQ/USP- one presenting circular-end feeding tube and the other three presenting rectangular-end feeding tubes with decreasing sections. The evaluation of the hydrocyclones performance was conducted by using suspensions of fine sand and clay soil under various pressure differentials. The comparison criteria used were the discharge and the separation capability, given by total efficiency and reduced total efficiency. Results showed that the hydrocyclone with circular-end feeding tube presented the highest indexes for the comparison criteria adopted, considering sand and soil suspensions.

Page generated in 0.0569 seconds