• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 570
  • 336
  • 39
  • 21
  • 15
  • 12
  • 11
  • 8
  • 8
  • 8
  • 8
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 1191
  • 1191
  • 1191
  • 571
  • 556
  • 423
  • 157
  • 134
  • 129
  • 128
  • 120
  • 110
  • 94
  • 93
  • 92
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
971

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Alexandre Vinícius Festa 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.
972

Uma nova metodologia para análise da qualidade da energia elétrica sob condições de ocorrência de múltiplos distúrbios / A new methodology for power quality analysis under multiple disturbance occurrence

Marcelo Antonio Alves Lima 14 October 2013 (has links)
Um Sistema Elétrico de Potência (SEP) está susceptível à presença de diversas fontes de distúrbios que prejudicam a Qualidade da Energia Elétrica (QEE). Desta forma, as suas tensões e/ou correntes podem conter m´múltiplos distúrbios com ocorrência simultânea. Este trabalho apresenta uma metodologia para decomposição do sinal medido em componentes que estimem as formas de onda dos distúrbios individuais quando da ocorrência de m´múltiplos distúrbios, com o posterior reconhecimento de cada um deles. A Análise de Componentes Independentes (ICA) é utilizada como principal ferramenta na etapa de decomposição dos distúrbios. A ICA é originalmente uma t´técnica aplicada em análise multivariada de dados, o que significa que ela necessita de medições realizadas por múltiplos sensores dispostos em diferentes posições de um sistema. No entanto, este trabalho propõe a sua aplicação tendo disponível apenas um sinal medido. Para tanto, são propostos dois métodos para produzir a diversidade necessária para a t´técnica funcionar adequadamente. É demonstrado que ambos os métodos equivalem a um banco de filtros lineares adaptativos capaz de realizar a separação não-supervisionada de múltiplos distúrbios independentes e que sejam espectralmente disjuntos. Por fim, é proposto um sistema de classificação que utiliza Redes Neurais Artificiais (RNAs) para identificar os distúrbios decompostos pela etapa anterior. A metodologia completa é avaliada por meio de testes utilizando dados sintéticos e reais, alcançando resultados altamente satisfatórios para decomposição de sinais contendo múltiplos distúrbios e taxas de acerto globais dos classificadores superiores a 97% / The power system is susceptible to the presence of several sources of disturbances that harm the power quality. In this sense, its voltages and/or currents may contain multiple disturbances with simultaneous occurrence. This work presents a methodology that decomposes the measured signal in components which estimate the waveforms of the individual disturbances followed by their recognition when a multiple disturbance situation occurs. The Independent Component Analysis (ICA) is the main tool in the disturbance decomposition stage. The ICA is originally a technique applied in multivariate data analysis, which means that it requires measurements from multiple sensors allocated in different positions of the system. However, this work proposes its application for a single measured signal available. For this, two methods were developed in order to provide the required diversity to the ICA technique. It is demonstrated that both methods are equivalent to an adaptive linear filter bank capable to perform an unsupervised separation of multiple independent disturbances, if they are spectrally disjoint. A classification system based on artificial neural networks is proposed to identify the disturbances decomposed by the previous stage. The complete system is tested using synthetic and actual data, presenting highly satisfactory results for the decomposition of signals containing multiple disturbances, and precision for the classification task above 97%
973

Determinação de um parâmetro para monitoramento do desempenho de mensagens GOOSE do padrão IEC 61850 utilizadas em subestações de energia elétrica / Determination of a parameter for monitoring the performance of GOOSE messages used in electric power substations

Ulisses Chemin Netto 10 August 2012 (has links)
O desenvolvimento e utilização do padrão IEC 61850 alterou a concepção e operação das subestações de energia elétrica. O desempenho e confiabilidade do sistema de proteção depende da rede de comunicação de dados. Esta pesquisa propõe um parâmetro de dimensionamento e comparação de desempenho para o tempo de transferência das mensagens Generic Object Oriented Substation Event (GOOSE) entre Intelligent Electronic Devices (IEDs). Esse parâmetro foi obtido através do levantamento experimental da curva do tempo de transferência das mensagens GOOSE versus a ocupação percentual da largura de banda dos IEDs. Para a realização dos experimentos foram utilizados três IEDs, um switch Ethernet gerenciável, três microcomputadores do tipo PC, um relógio sincronizador Global Positioning System (GPS), cordões de fibra óptica, cabos do tipo par trançado sem blindagem e aplicativos de software. Os resultados mostraram que a partir de um limiar característico, o qual é distinto para cada IED ensaiado, o tempo de transferência excede o limite máximo permitido pelo padrão IEC 61850. A partir da análise destes dados, foi desenvolvido um sistema preditivo de monitoramento de banda para supervisionar a interface de rede dos IEDs. O sistema preditivo apresentou para a medição de banda um erro relativo médio igual a 0,55% em relação ao aplicativo comercial utilizado na comparação, já a predição feita pela rede neural artificial apresentou um erro de estimativa menor do que 3% para 91,30% das amostras utilizadas, além de modelar adequadamente o comportamento da série temporal que representa a ocupação de banda do IED monitorado. / The development and utilization of IEC 61850 standard changed the design and operation of electric power substations. The performance and reliability of the protection system depends on the data communication network. This research proposes a parameter for dimensioning and comparising the transfer time of Generic Object Oriented Substation Event (GOOSE) messages between different Intelligent Electronic Devices (IEDs). This parameter was obtained from experimental data related to the transfer time of GOOSE messages curve versus IEDs bandwidth percentage occupation. In this context, a laboratory structure was set up in order to carry out these experiments. This structure mainly consists of three IEDs, an Ethernet switch, three personal computers, a GPS Clock, fiber optic cables, unshielded twisted pair cables, as well as support software. The results show the existence of a characteristic threshold, different for each IED tested, after which the transfer time exceeded the total transmission time allowed for the IEC 61850 standard. Based on these results, a predictive bandwidth monitoring system was developed to supervise the IEDs bandwidth interface. The bandwidth measurement has a mean relative error of 0.55% regarding to the commercial software used for comparison. Finally, the forecasting made by the artificial neural network has a relative error of 3% for 91,30% of the samples used in test phase. In addition, that it was able to model the behaviour of the time series that represent the bandwidth occupation.
974

Redes neurais dinÃmicas para prediÃÃo e modelagem nÃo-linear de sÃries temporais / Dynamic neural networks for nonlinear tools for time series prediction and modeling

Josà Maria Pires de Menezes JÃnior 14 July 2006 (has links)
Neste trabalho, redes neurais dinÃmicas sÃo avaliadas como modelos nÃo-lineares eficientes para prediÃÃo de sÃries temporais complexas. Entre as arquiteturas avaliadas estÃo as redes FTDNN, Elman e NARX. A capacidade preditiva destas redes sÃo testadas em tarefas de prediÃÃo de um-passo-adiante e mÃltiplos-passos-adiante. Para este fim, sÃo usadas as seguintes sÃries temporais: sÃrie laser caÃtico, sÃrie caÃtica Mackey-Glass, alÃm de sÃries de trÃfego de rede de computadores com caracterÃsticas auto-similares. O uso da rede NARX em prediÃÃo de sÃries temporais à uma contribuiÃÃo desta dissertaÃÃo. Esta rede possui uma arquitetura neural recorrente usada originalmente para identificaÃÃo entrada-saÃda de sistemas nÃo-lineares. A entrada da rede NARX à formada por duas janelas deslizantes (sliding time window), uma que desliza sobre o sinal de entrada e outra que desliza sobre sinal de saÃda. Quando aplicada para prediÃÃo caÃtica de sÃries temporais, a rede NARX à projetada geralmente como um modelo autoregressivo nÃolinear (NAR), eliminando a janela de atraso da saÃda. Neste trabalho, à proposta uma estratÃgia simples, porÃm eficiente, para permitir que a rede NARX explore inteiramente as janelas de tempo da entrada e da saÃda, a fim de melhorar sua capacidade preditiva. Os resultados obtidos mostram que a abordagem proposta tem desempenho superior ao desempenho apresentado por preditores baseados nas redes FTDNN e Elman.
975

Tecnologias WEB aplicadas aos sistemas elétricos de potência / Web technologies applied to electrical power systems

Lazaro Eduardo da Silva 09 August 2010 (has links)
A utilização de equipamentos digitais e de meios de comunicação de dados, na conexão entre os dispositivos de uma subestação de energia elétrica oportunizam o uso de tecnologias para aprimorar e elevar as potencialidades de controle e supervisão do sistema elétrico de potência. As concessionárias de energia elétrica demandam altos investimentos na construção e implantação de sistemas de supervisão, controle e aquisição de dados. A partir destes sistemas é possível visualizar em um mapa da rede elétrica, os pontos de instalação dos relés e os status do seu funcionamento, possibilitando a concretização de um diagnóstico e o controle destes equipamentos. A World Wide Web se tornou um meio conveniente para acesso às informações devido ao fato dos browsers serem capazes de integrar diferentes serviços de rede em uma única e amigável interface com o usuário. A implementação de um sistema de supervisão e controle utilizando tecnologias web gratuitas pode, com custo competitivo, agregar dados que estejam dispostos geograficamente, em uma plataforma computacional ergonômica, coesa e flexível, provendo acesso aos mesmos a partir de qualquer dispositivo conectado a Internet. Como resultado deste trabalho, foi implementado um sistema Web de controle e supervisão de um bay típico de saída de linha com interface simples, geração de relatórios pertinentes e anunciação de eventos. Foi implementado um segundo sistema Web de supervisão de uma lógica de corte e restabelecimento de cargas conhecido como ERAC (Esquema Regional de Alívio de Carga) que, utilizando recursos distribuídos, exibe em uma interface intuitiva as regiões de atuação dos estágios de cortes, anunciando os eventos e gerando relatórios de interesse. Por fim, foi desenvolvido um sistema de aquisição de dados de frequência e tensão de um medidor de qualidade da energia elétrica, construção de gráficos com os dados variantes no tempo, exportação dos dados de acordo com um período selecionado e implementação de uma rede neural perceptron multicamadas Time Delay Neural Network para predição dos valores de frequência futuros. As aplicações de supervisão e controle do sistema elétrico foram desenvolvidas com tecnologias Web e testadas em uma rede Intranet, de forma a avaliar a pertinência da implementação de aplicações para o sistema elétrico de potência, que podem ser acessadas de um browser padrão. Cabe ressaltar que todo sistema desenvolvido foi testado em equipamentos reais que fazem parte de uma estrutura laboratorial disponível, aos alunos de pós-graduação da Universidade de São Paulo, Escola de Engenharia de São Carlos, Laboratório de Sistemas de Energia Elétrica onde duas subestações com relés digitais comerciais são simuladas em bastidores interligados por um backbone de fibra óptica, os quais estão conectados a rede local do laboratório, permitindo o acesso remoto aos equipamentos. Tais sistemas, por estarem em plataforma Web, podem agregar recursos, que estão distribuídos, na construção de interfaces amigáveis e intuitivas, além da disponibilidade de acesso a informação de qualquer ponto conectado à Internet que uma aplicação Web oportuniza. / The use of digital equipment and data communication for the connection of the devices in an electric power substation provides the implementation of new technologies to improve and upgrade the potentialities of control and supervision of an electrical power system. The utilities demand high investments in the establishment and implementation of supervision, control and data acquisition systems. Based on these systems, it is possible to visualize a map of the electrical network, the installation points of digital relays and the status of their functions, making it possible the diagnosis and control of such equipment. The World Wide Web started a convenient access to information due to the friendly interface with the user. The implementation of a supervising and control system using free web technologies can, in a competitive cost, join data which are geographically available to an ergonomic computational platform and also provides access to the users from any device connected to the web. As a result of this work, a supervision Web control System of a typical bay with a simple interface was set up, as well as the development of reports and announcement of events. A second network supervision system for cutting load and for power reestablishment, known as regional load relief scheme, was implemented. Finally, a voltage and frequency data acquisition system from a power quality equipment with time varying graphics was developed as well as a implementation of a multiple neural perception net (Time Delay Neural Network) in order to predict future values of the frequency. The supervision and control applications were developed with web technologies and tested using an intranet in order assure the application on the electrical power system, which can be accessed by a standard browser. It is relevant to mention that the whole system was tested in actual equipment which belongs to a laboratorial structure available to the post graduation students at the University of São Paulo, School of Engineering of São Carlos, Power Systems Laboratory where two substations with commercial digital relays are simulated and interconnected by a fiber optics backbone and also connected to the local laboratory network which allows remote access to the equipment. Such system as set up in a web platform that can add resources which are distributed in the development of a friendly and intuitive interface in addition to the availability of access to the information from any point connected to the web.
976

A methodology for improving computed individual regressions predictions. / Uma metodologia para melhorar predições individuais de regressões.

Élia Yathie Matsumoto 23 October 2015 (has links)
This research proposes a methodology to improve computed individual prediction values provided by an existing regression model without having to change either its parameters or its architecture. In other words, we are interested in achieving more accurate results by adjusting the calculated regression prediction values, without modifying or rebuilding the original regression model. Our proposition is to adjust the regression prediction values using individual reliability estimates that indicate if a single regression prediction is likely to produce an error considered critical by the user of the regression. The proposed method was tested in three sets of experiments using three different types of data. The first set of experiments worked with synthetically produced data, the second with cross sectional data from the public data source UCI Machine Learning Repository and the third with time series data from ISO-NE (Independent System Operator in New England). The experiments with synthetic data were performed to verify how the method behaves in controlled situations. In this case, the outcomes of the experiments produced superior results with respect to predictions improvement for artificially produced cleaner datasets with progressive worsening with the addition of increased random elements. The experiments with real data extracted from UCI and ISO-NE were done to investigate the applicability of the methodology in the real world. The proposed method was able to improve regression prediction values by about 95% of the experiments with real data. / Esta pesquisa propõe uma metodologia para melhorar previsões calculadas por um modelo de regressão, sem a necessidade de modificar seus parâmetros ou sua arquitetura. Em outras palavras, o objetivo é obter melhores resultados por meio de ajustes nos valores computados pela regressão, sem alterar ou reconstruir o modelo de previsão original. A proposta é ajustar os valores previstos pela regressão por meio do uso de estimadores de confiabilidade individuais capazes de indicar se um determinado valor estimado é propenso a produzir um erro considerado crítico pelo usuário da regressão. O método proposto foi testado em três conjuntos de experimentos utilizando três tipos de dados diferentes. O primeiro conjunto de experimentos trabalhou com dados produzidos artificialmente, o segundo, com dados transversais extraídos no repositório público de dados UCI Machine Learning Repository, e o terceiro, com dados do tipo séries de tempos extraídos do ISO-NE (Independent System Operator in New England). Os experimentos com dados artificiais foram executados para verificar o comportamento do método em situações controladas. Nesse caso, os experimentos alcançaram melhores resultados para dados limpos artificialmente produzidos e evidenciaram progressiva piora com a adição de elementos aleatórios. Os experimentos com dados reais extraído das bases de dados UCI e ISO-NE foram realizados para investigar a aplicabilidade da metodologia no mundo real. O método proposto foi capaz de melhorar os valores previstos por regressões em cerca de 95% dos experimentos realizados com dados reais.
977

Mapeamento e estimativa de área de cana-de-açúcar no estado do Paraná / Mapping and estimate of the sugarcane area in Paraná state, Brazil

Cechim Júnior, Clóvis 04 February 2016 (has links)
Made available in DSpace on 2017-07-10T19:24:19Z (GMT). No. of bitstreams: 1 Clovis_Cechim_MC.pdf: 6987482 bytes, checksum: c33db297dd7ec8aaf8bfde9e1e56c2cc (MD5) Previous issue date: 2016-02-04 / Sugarcane has been cropped and produced in Brazil for a long time, so, it deserves mention because it makes the country as the largest producer, with also representativeness in sugar and ethanol production. The knowledge of reliable estimates concerning their cropped areas is essential for Brazilian agribusiness, as they help in determining prices to producers by power plants as well as allow establishing logistics flow of production. The cropped areas estimates are made by official agencies. Therefore, in order to reduce this subjectivity, geotechnology use comes as an alternative since it has been widely used in mappings agricultural crops. Thus, this study aimed at developing a methodology for mapping sugarcane crop in Paraná State with satellite images as LANDSAT, IRS and spectrum-temporal series of vegetation indexes from MODIS sensor, for 2010/2011 to 2014/2015 harvesting season. The carried out mappings indicated a strong positive correlation concerning Canasat and official IBGE. The developed method was based on Fuzzy ARTMAP classification and was efficient to map and estimate the sugarcane cropped area using vegetation index in Paraná State. / A cana-de-açúcar como cultura cultivada e produzida no Brasil merece destaque, pois torna o País o maior produtor mundial, com representatividade também na produção de açúcar e etanol. O conhecimento de estimativas confiáveis de suas áreas cultivadas é imprescindível para o agronegócio brasileiro, por auxiliar na determinação dos preços aos produtores pelas usinas e permitir estabelecer a logística de escoamento da produção. As estimativas de área cultivada são realizadas de forma subjetiva pelos órgãos oficiais. Com a finalidade de diminuir tal subjetividade, surge como alternativa o uso de geotecnologias, as quais têm sido muito utilizadas em mapeamentos de culturas agrícolas. Diante disto, o objetivo deste trabalho foi o desenvolvimento de uma metodologia para o mapeamento da cultura de cana-de-açúcar para o Estado do Paraná usando imagens dos satélites LANDSAT, IRS e de séries espectro-temporais de índices de vegetação, provenientes do sensor MODIS, para as safras de 2010/2011 a 2014/2015. O mapeamento da cultura foi realizado a partir do modelo de classificação supervisionada Fuzzy ARTMAP, tendo como variáveis de entrada, termos harmônicos de amplitude e fase e as métricas fenológicas da cultura. Os mapeamentos realizados indicaram forte correlação positiva com relação aos dados do Canasat e oficiais IBGE. O método desenvolvido com base na classificação Fuzzy ARTMAP demonstrou ser eficiente para mapear e estimar a área cultivada da cultura de cana-de-açúcar utilizando índices de vegetação no Estado do Paraná.
978

Identificação de faltas de alta impedância em redes aéreas multiaterradas. / Identification of high impedance faults in overhead multi grounded networks.

Juan Camilo Garcia Arias 12 December 2014 (has links)
As faltas de alta impedância (FAI) ocorrem quando um condutor entra em contato com objetos com uma alta resistência, o que não resulta em incrementos significativos de corrente. Este tipo de falta não pode ser detectada por dispositivos de proteção tradicionais que atuam por sobrecorrente. Neste trabalho uma pesquisa do estado da arte das FAI é apresentada e são implementados alguns algoritmos de detecção presentes na literatura. Nesta pesquisa também são propostas duas metodologias de identificação de FAI as quais são baseadas na identificação de buildup e incrementos de energias na faixa de frequências 1920Hz a 3840Hz. Os algoritmos implementados e as metodologias propostas foram testados com simulações de eventos de FAI e de eventos comuns numa rede simulada de uma concessionária do Estado de São Paulo utilizando o software ATP. Estudos do funcionamento de um medidor de qualidade de energia foram feitos com o propósito de determinar as limitações de uma eventual implementação real das metodologias de identificação propostas neste trabalho. Resultados do desempenho das metodologias propostas utilizando os sinais simulados em ATP apresentaram percentagens de identificação superiores aos 80%. Análise das ocorrências de cabo rompido do circuito em estudo foram feitas com o propósito de identificar possíveis eventos de FAI. O desempenho apresentado pelas metodologias propostas na identificação de FAI em sinais reais pode ser melhorado com a disponibilidade de uma maior quantidade de eventos reais de FAI. / High impedance faults (HIF) occur when a conductor makes contact with high resistance objects, generally not resulting in significant current increases. This type of fault cannot be detected by traditional overcurrent protection devices. In this work, a research of the HIF state-of-art is presented and some detection algorithms in the literature are implemented. This research also proposes two HIF identification methods based on respectively the identification of buildup current and energy increments in the frequency range from 1920Hz to 3840Hz. The implemented algorithms and the proposed methodology have been tested with ATP simulations of FAI events and other common events in a simulated network from an electric utility in the State of Sao Paulo. Studies are carried out in order to assess the operation of a power quality meter to determine the limitations of real implementations of the proposed methodologies. Performance results of the proposed methodologies using simulated ATP signals show identifications rates greater than 80%. Broken conductor occurrences in the studied feeder are analyzed to identify possible HIF events. The performance shown by the proposed methodologies in identifying HIF in real situations can be improved with the availability of a larger number of HIF events.
979

Desenvolvimento de uma metodologia baseada em redes neurais artificiais para a identificação de anomalias em redes de comunicação Profinet / Development of a methodology based on artificial neural networks to identify abnormalities in Profinet communication networks

Afonso Celso Turcato 25 June 2015 (has links)
Este trabalho propôs o desenvolvimento e a avaliação de uma metodologia com o propósito de identificar anomalias em redes de comunicação Profinet, muito utilizadas na automação de plantas industriais. A metodologia desenvolvida está fundamentada na análise das características de comunicação do protocolo Profinet e na identificação e classificação de padrões, sendo esta, uma das principais aplicações do uso de Redes Neurais Artificiais (RNA). As anomalias são identificadas por meio da análise do tráfego de rede Profinet em sua fase de operação. Tais anomalias podem ser desde defeitos comuns apresentados pelos equipamentos da rede e/ou tentativas de ataques a esta, que por sua vez, podem gerar instabilidade e mau funcionamento da unidade industrial que fazem parte. Para o desenvolvimento deste trabalho foram apresentados: o detalhamento do protocolo Profinet, os mecanismos de segurança mais utilizados atualmente, os tipos de sistemas de detecção de anomalias existentes e os principais tipos de ataques em redes de comunicação conhecidos na literatura. Alguns ensaios para a validação da metodologia foram realizados, utilizando-se uma infraestrutura de rede instalada em laboratório. Ensaios com diferentes tipos de equipamentos interligados em rede foram realizados e os resultados apresentados. Como resultado final, demonstrou-se que a metodologia utilizada obteve êxito na identificação da presença ou ausência de anomalias na rede, sendo que os resultados obtidos podem ser considerados satisfatórios e condizentes às expectativas desta dissertação. Concluiu-se então que a metodologia apresentada é factível e aplicável no meio industrial, podendo ser incorporada a uma ferramenta mais abrangente, como os analisadores de redes Profinet. / This work proposed the development and evaluation of a methodology in order to identify anomalies in Profinet communication networks, widely used in the automation of industrial plants. The methodology is based on an analysis of the communication features of the Profinet protocol and identifying and pattern classification, which is one of the main applications of the use of Artificial Neural Networks (ANN). The anomalies are identified by analyzing the Profinet network traffic in its operation phase. Such anomalies can be provided by common defects in equipment in the network and / or attempted attacks to this, which in turn can cause instability and malfunction of the plant forming part. In development of this work were presented: the details of the Profinet protocol, the security mechanisms most widely used, the types of anomalies detection systems and the main types of attacks on communication networks known in the literature. Some assays to validate the method were performed, using a network infrastructure installed in the laboratory. Tests with different types of networked equipment were performed and the results presented. The final result showed that the methodology was successful in identifying the presence or absence of anomalies in the network, and the obtained results can be considered satisfactory and consistent with expectations of this paper. It was therefore concluded that this methodology is feasible and applicable in industrial environment and can be incorporated into a more comprehensive tool, such as analyzers Profinet networks.
980

Mapeamento e estimativa de área de cana-de-açúcar no estado do Paraná / Mapping and estimate of the sugarcane area in Paraná state, Brazil

Cechim Júnior, Clóvis 04 February 2016 (has links)
Made available in DSpace on 2017-05-12T14:47:35Z (GMT). No. of bitstreams: 1 Clovis_Cechim_MC.pdf: 6987482 bytes, checksum: c33db297dd7ec8aaf8bfde9e1e56c2cc (MD5) Previous issue date: 2016-02-04 / Sugarcane has been cropped and produced in Brazil for a long time, so, it deserves mention because it makes the country as the largest producer, with also representativeness in sugar and ethanol production. The knowledge of reliable estimates concerning their cropped areas is essential for Brazilian agribusiness, as they help in determining prices to producers by power plants as well as allow establishing logistics flow of production. The cropped areas estimates are made by official agencies. Therefore, in order to reduce this subjectivity, geotechnology use comes as an alternative since it has been widely used in mappings agricultural crops. Thus, this study aimed at developing a methodology for mapping sugarcane crop in Paraná State with satellite images as LANDSAT, IRS and spectrum-temporal series of vegetation indexes from MODIS sensor, for 2010/2011 to 2014/2015 harvesting season. The carried out mappings indicated a strong positive correlation concerning Canasat and official IBGE. The developed method was based on Fuzzy ARTMAP classification and was efficient to map and estimate the sugarcane cropped area using vegetation index in Paraná State. / A cana-de-açúcar como cultura cultivada e produzida no Brasil merece destaque, pois torna o País o maior produtor mundial, com representatividade também na produção de açúcar e etanol. O conhecimento de estimativas confiáveis de suas áreas cultivadas é imprescindível para o agronegócio brasileiro, por auxiliar na determinação dos preços aos produtores pelas usinas e permitir estabelecer a logística de escoamento da produção. As estimativas de área cultivada são realizadas de forma subjetiva pelos órgãos oficiais. Com a finalidade de diminuir tal subjetividade, surge como alternativa o uso de geotecnologias, as quais têm sido muito utilizadas em mapeamentos de culturas agrícolas. Diante disto, o objetivo deste trabalho foi o desenvolvimento de uma metodologia para o mapeamento da cultura de cana-de-açúcar para o Estado do Paraná usando imagens dos satélites LANDSAT, IRS e de séries espectro-temporais de índices de vegetação, provenientes do sensor MODIS, para as safras de 2010/2011 a 2014/2015. O mapeamento da cultura foi realizado a partir do modelo de classificação supervisionada Fuzzy ARTMAP, tendo como variáveis de entrada, termos harmônicos de amplitude e fase e as métricas fenológicas da cultura. Os mapeamentos realizados indicaram forte correlação positiva com relação aos dados do Canasat e oficiais IBGE. O método desenvolvido com base na classificação Fuzzy ARTMAP demonstrou ser eficiente para mapear e estimar a área cultivada da cultura de cana-de-açúcar utilizando índices de vegetação no Estado do Paraná.

Page generated in 0.4749 seconds