• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 41
  • 19
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 109
  • 109
  • 109
  • 44
  • 44
  • 43
  • 37
  • 37
  • 36
  • 32
  • 22
  • 19
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Korozní degradace hořčíkových slitin v SBF roztocích / Corrosion degradation of magnesium alloys in SBF solutions

Ročňáková, Ivana January 2012 (has links)
Nowadays, magnesium alloys are used in many sectors of human activity, particularly in the aerospace and automotive industries, due to a combination of good mechanical properties and low density of magnesium. Recently, however, the attention is paid to the possibility of using magnesium alloys in the medical field, mainly due to the chemical properties of magnesium. The diploma thesis is focused on evaluating of the corrosion behavior of AZ31alloy and AZ61 alloys in SBF solutions that are solutions simulating body fluids. The alloys were subjected to immersion test in Hank’s solutions for time span from 24 to 1008 hours. The corrosion process was evaluated based on several factors: alloy composition, time and pH changes. The thesis also describes in detail the methodology for establishing magnesium and zinc by method of flame absorption spektrometry (F AAS). The determination of aluminum was carried out by atomic absorption spectrometry with electrothermal atomization (ET AAS).
72

Stanovení obsahu platiny na území města Brna / Determination of platinum in Brno's agglomeration

Dvořák, Rostislav January 2014 (has links)
This thesis is focused on the determination of platinum in samples of road dust and soil by atomic absorption spectrometry. The theoretical part describes the basic physical and chemical properties of platinum, platinum function in automotive converters and its behavior in the environment. In the experimental section summarizes the methods used to decompositions samples, concentration of the analyte and the main results of the measurements.
73

Stanovení platinových kovů ve velkých městských aglomeracích / Determination of platinum group metals in great urban agglomerations

Ježek, Stanislav January 2016 (has links)
The aim of this thesis is the actual elaboration literature search concerning the issue of platinum group metals in the environment, determination of platinum and palladium in great urban agglomerations. It includes chemical and physical properties, occurrence and platinum and palladium cycle in the environment. It also contains methods for extraction and determination of platinum and palladium.
74

Stanovení selenu metodou HG-AAS s prekoncentrací a atomizací v plazmovém výboji s dielektrickou bariérou / Selenium determination by HG-AAS with preconcentration and atomization in a dielectric barrier plasma discharge

Duben, Ondřej January 2015 (has links)
The aim of this thesis was to optimize atomization conditions for selenium hydride in a novel plasma atomizer based on dielectric barrier discharge (DBD) using atomic absorption spectrometry as a detector. Analytical characteristics have been subsequently determined and compared to those reached in a conventional externally heated quartz tube atomizer which was replaced by a sofisticated design of a multiatomizer (MMQTA) in this work. The limit of detection reached in DBD (0,24 ng ml−1 Se) is slightly worse to that observed in MMQTA (0,15 ng ml−1 Se). On the contrary, slightly better resistance towards interferences of Sb, Bi and As was observed in DBD atomizer in comparison with MMQTA. Possibility of selenium preconcentration in a DBD atomizer was studied reaching an overall preconcentration efficiency of 75 ± 5%. The detection limit in a preconcentration mode employing preconcentration period of 300 s has reached 0,012 ng ml−1 Se. Key words: hydride generation atomic absorption spectrometry, dielectric barrier discharge, hydride atomization, hydride trapping, selenium
75

HG-AAS s atomizací v plazmovém výboji s dielektrickou bariérou: optimalizace metody a analytické aplikace / HG-AAS with atomization in a dielectric barrier plasma discharge: method optimization and analytical applications

Zurynková, Pavla January 2016 (has links)
The aim of this diploma thesis was to optimize in detail atomization conditions for antimony hydride in a novel plasma atomizer based on a dielectric barrier discharge (DBD) with atomic absorption spetrometric detection. Argon was found as the best DBD discharge gas employing a flow rate of 50 ml min-1 Ar while the DBD power was optimized at 30 W. Analytical figures of merit including interference study of As, Se and Bi have been subsequently investigated and the results compared to those found in an externally heated quartz tube atomizer (QTA). The limit of detection reached in DBD (0.15 ng ml-1 Sb) is comparable to that observed in QTA (0.14 ng ml-1 Sb). Finally, possibility of stibane preconcentration in a DBD atomizer was studied. Preconcentration efficiency of 102 ± 6 % was found under optimized conditions.
76

Stanovení arsenu v pivu a surovinách pro jeho výrobu / Arsenic determination in beer samples and raw materials for its preparation

Švadlenová, Veronika January 2017 (has links)
This thesis describes the optimization of the method for determination of arsenic by the chemical hydride generation coupled with AAS detection in beer samples and raw materials for its preparation. The beer usually contain arsenic at ultratrace level, however, it is necessary to monitor the concentration of this element in the beer. The routinely used method for determination of arsenic is determination by electrothermal atomization. This approach is time consuming, expensive and less sensitive. It has been developer suitable determination of arsenic as a faster and less expensive method. For this method there was optimized the flow rate of argon to 75 ml·min-1, the optimum flow rate for the reagents was 4.0 ml·min-1 and for the sample 5.0 ml·min-1 . 3 % NaBH4 in 0.5 % NaOH was used as the reducing agent for the determination of arsenic, and HCl diluted 1:1 with distilled water was used to acidify the sample. With this parameter LOD was 0.32 μg·l-1 and LOQ 1.05 μg·l-1 . It has been tested the arsenic determination in samples of barley, malt and potable water as beer raw materials. It has been found that the beer matrix is unsuitable for the hydride generation technique due to a stormy reaction in the gas/liquid phase separator. The effect of pretreatment, which is likely to enhance the effect of...
77

Analýza nanočásticových systémů atomovou spektrometrií / Analysis of nanopartical systems by atomic spectrometry

Jeníková, Eva January 2018 (has links)
EN The present diploma thesis is focused on optimization methods of titanium and phosphorus concentration for their use in the colloidal solution of TiO2 nanoparticles modified by bisphosphonates. For these analyses was used atomic absorption spectrometry with flame and electrothermal atomization. The characteristics of the two analytes were compared to two different spectrometers. Using the F-AAS technique on the GBC 933 AA spectrometer has been achieved a detection limit of 5,2 mg l-1 for titanium and a detection limit of 163 mg l-1 for the phosphorus. Using the ContrAA 700 spectrometer, F-AAS has been achieved an almost five times lower detection limit of 1,1 mg l-1 for titanium determination. For determination of phosphorus using this spectrometer, was obtained a similar value of 151 mg l-1 , as using the GBC 933 AA spectrometer. The determination of phosphorus by the ET-AAS technique using the ContrAA 700 spectrometer resulted in a detection limit of 1,23 mg l-1 , which is a significant difference compared to the flame system. It has been proved that optimized methods are consistent with the intention, which was confirmed by the analysis of real titanium and phosphorus samples in the colloidal solution of TiO2 nanoparticles modified bisphosphonates.
78

Stanovení Te(IV) pomocí fotochemického generování těkavých sloučenin ve spojení s atomovými spektrálními metodami / Determination of Te(IV) by photochemical generation of volatile compounds with atomic spectrometric detection

Ruxová, Helena January 2020 (has links)
This thesis deals with the development of a method suitable for determination Te(IV) by UV-photochemical generation of volatile compounds (UV-PVG) in liquid samples. Atomic absorption spectrometry (AAS) and atomic fluorescent spectrometry (AFS) were used as detection methods. The basis of the apparatus for UV-PVG was a mercury lamp wrapped by PTFE capillary. Firstly, the experimental parameters were optimized for both methods. The optimized parameters were the type, concentration, pH and flow rate of the reaction medium, the length of the PTFE reaction coil, carrier gas flow rate (argon), supportive gas flow rate (hydrogen) and atomization temperature. The figures of merit with both detection methods were determined and compared after the method was optimized. Detection limits achieved for these two detection methods were 6,0 µg dm-3 for AFS and 1,50 µg dm-3 for AAS. Performed interference study confirmed a significant effect of many cations of transition metals and hydride forming elements on tellurium determination. The influence of nitric acid in the sample was studied separately. The suitability of the method for tellurium determination was confirmed by using a spiked certified reference material.
79

Studium vlastností UV-fotochemického generování těkavých sloučenin antimonu / Study of properties of UV-photochemical generation of volatile compounds od antimony

Adámková, Dominika January 2020 (has links)
The master thesis deals with comparison of atomic fluorescence spektrometry and high resolution continuum source atomic absorption spektrometry for three methods generation of volatile compounds Antimony. In both methods of atomic antimony detection, it compares the most common chemical generation of volatile compounds (hydrides) with two alternative methods - electrochemical and UV - photochemical. The values of performance parameters for the determination of Sb(III) and Sb(V) were determined for all the above combinations. In the case of chemical generation, a surprisingly almost four times higher limit of detection of Sb(III) was found in connection with AFS detection than AAS detection. The final part was devoted to UV - photochemical vapor generation, with AAS detection for Sb(III) reaching limit of detection 4,96 ppb, for Sb(V) 8,63 ppb. Although UV - photochemical generation of volatile antimony compounds did not reach such performance parameters as chemical or electrochemical generation, it was observed that the sensitivity of antimony determination increased greatly when introducing oxygen into the apparatus. The interference study also found a significant positive effect of Fe(II) on the generation efficiency, and this modification partially persisted without further introduction of these...
80

Speciační analýza sloučenin selenu / Speciation analysis of selenium compounds

Kramulová, Barbora January 2011 (has links)
Previously, selenium was known as an element with negative properties. However, in the last century, the significant positive effects on human health were detected. Currently, the function, behavior and toxicity of selenium are still not well known. The key to understand it is to do speciation analysis. The aim of this diploma thesis is to develop method for determination inorganic (sodium selenite and selenate) and organic (selenourea, selenocystine, selenomethionine) selenium compounds. Parameters of apparatus for electrochemical hydride generation with atomic absorption spectrometry detector were optimized, final conditions were set and optimal conditions for separation process using HPLC were investigated. Calibration dependences for selenium compounds were measured and analytical figures of merit were investigated. In conclusion, a coupled method HPLC- EcHG- QFAAS for determination of individual selenium compounds was proposed, and it was tested on urea samples. Calibrations for these measurements were investigated and analytic characteristics were calculated. Based on these comparisons it can be said that proposed method allows the determination of selected selenium compounds in both aqueous and urea matrices. Subject words: Spectroscopy, analytical chemistry Key words: Atomic absorption...

Page generated in 0.1405 seconds