• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 23
  • 11
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 98
  • 98
  • 48
  • 41
  • 36
  • 34
  • 28
  • 26
  • 25
  • 25
  • 22
  • 20
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Comportamento de chumbadores grauteados de ligações viga-pilar parcialmente resistentes a momento fletor / Behavior of grouted dowel of partial moment resistant beam-to-column connections

Aguiar, Eduardo Aurélio Barros 05 May 2010 (has links)
Neste trabalho estudou-se o comportamento dos chumbadores grauteados, usados em ligações viga-pilar parcialmente resistentes a momento fletor. O foco da pesquisa foi a análise teórica e experimental do mecanismo resistente do chumbador inclinado. O programa experimental englobou 15 modelos, sendo que as variáveis analisados foram: a) diâmetros dos chumbadores, de 16 mm, 20 mm e 25 mm; b) inclinações dos chumbadores, de 0º (chumbador normal à interface), 45º e 60º; c) resistência à compressão do concreto adjacente ao chumbador, sendo usado concreto das classes C35 e C50; d) aplicação de força de compressão normal à interface. Os resultados experimentais indicaram aumentos significativos tanto na capacidade última quanto na rigidez a cisalhamento do chumbador. Foram realizadas simulações numéricas, onde foi verificada a sensibilidade dos resultados aos parâmetros inerentes à interface concreto - almofada de apoio, sendo desenvolvidas expressões para estimar tais parâmetros. Com base na análise experimental e em análises numéricas, foram propostos modelos analíticos que conseguiram representar de forma satisfatória a influência da inclinação e demais parâmetros analisados no mecanismo resistente do chumbador. / This research deals with the behavior of grouted dowels, used in partial moment resistant beam-to-column connections. The focus of the research was the theoretical and experimental analysis of dowels resistant mechanism. The experimental program include 15 models, and its variables analyzed were: a) the dowel diameter of 16 mm, 20 mm and 25 mm; b) the dowel inclination of 0° (dowels perpendicular to the interface), 45° and 60°; c) compressive strength of concrete adjacent to the dowels of classes C35 and C50, d) application of compression load, normal to the interface. Experimental results indicated significant increases in ultimate capacity and the shear stiffness of the dowels. Numerical simulations were carried out which identified the sensitivity of results to the parameters of the interface concrete bearing pad, and developed expressions to estimate such parameters are given. Based on experimental and numerical analysis analytical models have been proposed that could adequately represent the influence of inclination and other parameters in the mechanism resistant dowels.
52

Análise do comportamento estrutural de ligações em aço entre viga de seção I e pilar de seção tubular circular / Structural behavior of steel connections between I-beam and circular hollow section column

Pereira, Daniel Henrique Fidelis 08 November 2013 (has links)
Esta pesquisa consiste de uma investigação acerca do comportamento estrutural de ligações entre viga de seção I e pilar de seção tubular circular em situações de pilar de canto e de pilar solicitado por quatro vigas simultaneamente (pilar central). A associação entre a viga de seção I e o pilar de seção tubular circular remete à análise de ligações com comportamento complexo. A partir da análise numérica, via Método dos Elementos Finitos com os softwares ANSYS® e TrueGrid® foi avaliado o comportamento momento-rotação e parâmetros como resistência, rigidez inicial e ductilidade das ligações. Foram analisadas as tipologias de ligação soldada e ligação com a presença do diafragma externo como mecanismo de enrijecimento. Avaliou-se a influência de 6 variáveis, sendo o comprimento da viga, a espessura do pilar, a força aplicada nas vigas dispostas ortogonalmente, a compressão axial do pilar, a espessura do diafragma e o diâmetro dos parafusos do diafragma totalizando 20 modelos numéricos. O aumento da espessura da seção do pilar e a força aplicada simultaneamente nas 4 vigas representou uma melhoria na resistência e rigidez inicial das ligações soldadas. A redução do diâmetro dos parafusos do diafragma foi a principal variável capaz de influenciar negativamente as propriedades de rigidez inicial e resistência das ligações com o diafragma. Todos os modelos analisados apresentaram comportamento semi-rígido segundo o Eurocode 3 (2005). O dimensionamento analítico pelo Eurocode 3 (2005) e por Winkel (1998) apresentou boa aproximação com os resultados da análise numérica. A obtenção da resistência das ligações com diafragma pelo método das componentes apresentou resultados, em média, 20% inferiores ao verificado na modelagem numérica. A utilização do diafragma como mecanismo de enrijecimento das ligações mostrou-se eficiente. As ligações soldadas apresentaram maior ductilidade comparada às com diafragma. O aumento da espessura do pilar nas ligações soldadas demonstrou-se uma alternativa eficaz no enrijecimento das ligações. / This research consists of an investigation above the structural behavior of connections between I-beam and circular hollow section (CHS) columns in situation of corner columns and column loaded by 4 beams simultaneously (inside columns). The association between the I-beam and the CHS column presupposes the analysis of connections with a complex structural behavior. Based on a numerical analysis, using the Finite Element Method with ANSYS® and TrueGrid® softwares, the connection parameters like strength, stiffness and ductility was evaluated. The typologies of welded connections and connections with an external diaphragm was analyzed. An amount of 6 variables (beam length, column thickness, force applied on the beams, compression of the column, diaphragm thickness and bolt diameter) was analyzed in a total of 20 numerical specimens. The increase of the column thickness and the force applied simultaneously on the 4 beam ends culminated on a substantial improvement on strength and stiffness of the welded connections. The reduction of the diaphragm bolts diameter was the main reason for the negatively influence on strength and stiffness properties of the diaphragm connections. All specimens presented a semirigid behavior according to the Eurocode 3 (2005). The analytical design, based on the Eurocode 3 (2005) and Winkel (1998), obtained good results in terms of connections strength compared with the numerical analysis. The obtainment of the connections strength with the component method demonstrated results 20% less than numerical analysis. The external diaphragm as a stiffening mechanism showed effective. The welded connections presented more ductility than the diaphragm ones. The increase on the column thickness demonstrated an effective alternative for the connection stiffening.
53

Análise numérica da ancoragem em ligações do tipo viga-pilar de extremidade / Numerical analysis of the anchorage in the exterior beam-column connections

Edson Costa de Assis Júnior 14 October 2005 (has links)
Este trabalho é uma contribuição ao estudo da ancoragem de barras de aço da armadura longitudinal em ligações de elementos fletidos de concreto armado em edifícios usuais. São investigadas importantes pesquisas que mostram os avanços em relação ao entendimento do tema nas últimas décadas. É proposto um método de aferição dos modelos constitutivos dos materiais, concreto e aço, no programa de elementos finitos ADINA para verificações de projeto seguindo recomendações da NBR 6118:2003 e MC CEB-FIP 1990. São realizadas análises numéricas de modelos bidimensionais em ligações viga-pilar de extremidade os quais são comparados a modelos experimentais e retirados de projetos já existentes. Os parâmetros de análise são o momento de fissuração e a força de tração a ancorar na seção mais solicitada da viga, conferidos com valores calculados por métodos analíticos e/ou expressões normativas, as tensões e deformações máximas em pontos ao longo do trecho ancorado das armaduras de longitudinais da viga e a influência da força normal. Os resultados revelam que as simplificações e hipóteses assumidas para a concepção dos modelos numéricos são consistentes / This work contributes to the study of anchorage of longitudinal reinforcement steel bars in connections of flexural elements in reinforced concrete buildings. Some important researches are investigated showing the advances of the subject in the last decades. An evaluation method of material’s constitutive models, steel and concrete, using the Finite Element Analysis in the software ADINA is proposed, to project verifications according to NBR 6118:2003 and MC CEB-FIP 1990 recommendations. Comparisons between numerical analysis by using a two-dimensional model of exterior beam-column connections and experimental analysis and using existing projects are made. The analysis parameters are the cracking moment and the anchored steel bar tension force in the most requested beam section, compared to the values calculated by analytical methods and/or design expressions, the maximum stresses and strains in points along to anchored steel bar of the beam longitudinal reinforcement and the influence of the normal force. The results show that the assumed simplifications and hypothesis for the numerical model conception are consistent
54

Ligações mistas viga-pilar - análise teórica e experimental / Composite beam-column connection – Theoretical and experimental analysis

Luciana Maria Bonvino Figueiredo 19 August 2004 (has links)
Uma ligação em estruturas de aço é denominada mista quando considera-se a contribuição da laje no seu comportamento. Assim, além do detalhe da ligação em aço, outros parâmetros interferem no comportamento da ligação mista, como a taxa de armadura e o nível de interação entre a laje e a viga de aço. Os métodos de cálculo de ligações mistas derivam do Método dos Componentes proposto pelo Eurocode 3 para cálculo de ligações em aço. Apresenta-se uma adaptação de um destes métodos para cálculo de ligações mistas que representam a realidade brasileira em termos de perfis e detalhes de ligação. Foi elaborado um programa experimental de caráter exploratório envolvendo ligações mistas com chapa de topo estendida. Foram ensaiados modelos simulando pilares internos e pilares de canto. Um modelo numérico foi desenvolvido utilizando o programa Ansys, que permite a análise destas ligações de maneira simples e satisfatória. Os resultados experimentais foram confrontados com os resultados da análise numérica e com os valores obtidos a partir do modelo analítico. / A composite joint is a joint between a composite beam and a steel or composite column in which reinforced concrete slab is take into account. The moment-rotation relationship of composite joints depends on a significant number of parameters besides the type and configuration of the steel connection, as for example: the amount of steel reinforcement of the slab and the degree of interaction between the slab and the steel beam section. Based on the Eurocode 3 method for bare steel connection (Components Method), some methods have been developed for prediction the moment capacities of composite connections. I this work, an adaptation of one of these methods has been developed in which steel sections and connections details common in Brazil are considered. A short experimental program was planed in order to understand the composite behaviour of extended end-plate composite beam-column connection. The test specimens were configured as cruciform type and cantilever type. Finally, a Finite Element model was built in Ansys software. The numerical modeling was found to have good approach with experimental results. Some analyses are done involving experimental, numerical and analytical results.
55

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

Trotta, André Marcon 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.
56

Ligações mistas viga-pilar - análise teórica e experimental / Composite beam-column connection – Theoretical and experimental analysis

Figueiredo, Luciana Maria Bonvino 19 August 2004 (has links)
Uma ligação em estruturas de aço é denominada mista quando considera-se a contribuição da laje no seu comportamento. Assim, além do detalhe da ligação em aço, outros parâmetros interferem no comportamento da ligação mista, como a taxa de armadura e o nível de interação entre a laje e a viga de aço. Os métodos de cálculo de ligações mistas derivam do Método dos Componentes proposto pelo Eurocode 3 para cálculo de ligações em aço. Apresenta-se uma adaptação de um destes métodos para cálculo de ligações mistas que representam a realidade brasileira em termos de perfis e detalhes de ligação. Foi elaborado um programa experimental de caráter exploratório envolvendo ligações mistas com chapa de topo estendida. Foram ensaiados modelos simulando pilares internos e pilares de canto. Um modelo numérico foi desenvolvido utilizando o programa Ansys, que permite a análise destas ligações de maneira simples e satisfatória. Os resultados experimentais foram confrontados com os resultados da análise numérica e com os valores obtidos a partir do modelo analítico. / A composite joint is a joint between a composite beam and a steel or composite column in which reinforced concrete slab is take into account. The moment-rotation relationship of composite joints depends on a significant number of parameters besides the type and configuration of the steel connection, as for example: the amount of steel reinforcement of the slab and the degree of interaction between the slab and the steel beam section. Based on the Eurocode 3 method for bare steel connection (Components Method), some methods have been developed for prediction the moment capacities of composite connections. I this work, an adaptation of one of these methods has been developed in which steel sections and connections details common in Brazil are considered. A short experimental program was planed in order to understand the composite behaviour of extended end-plate composite beam-column connection. The test specimens were configured as cruciform type and cantilever type. Finally, a Finite Element model was built in Ansys software. The numerical modeling was found to have good approach with experimental results. Some analyses are done involving experimental, numerical and analytical results.
57

Análise numérica da ancoragem em ligações do tipo viga-pilar de extremidade / Numerical analysis of the anchorage in the exterior beam-column connections

Assis Júnior, Edson Costa de 14 October 2005 (has links)
Este trabalho é uma contribuição ao estudo da ancoragem de barras de aço da armadura longitudinal em ligações de elementos fletidos de concreto armado em edifícios usuais. São investigadas importantes pesquisas que mostram os avanços em relação ao entendimento do tema nas últimas décadas. É proposto um método de aferição dos modelos constitutivos dos materiais, concreto e aço, no programa de elementos finitos ADINA para verificações de projeto seguindo recomendações da NBR 6118:2003 e MC CEB-FIP 1990. São realizadas análises numéricas de modelos bidimensionais em ligações viga-pilar de extremidade os quais são comparados a modelos experimentais e retirados de projetos já existentes. Os parâmetros de análise são o momento de fissuração e a força de tração a ancorar na seção mais solicitada da viga, conferidos com valores calculados por métodos analíticos e/ou expressões normativas, as tensões e deformações máximas em pontos ao longo do trecho ancorado das armaduras de longitudinais da viga e a influência da força normal. Os resultados revelam que as simplificações e hipóteses assumidas para a concepção dos modelos numéricos são consistentes / This work contributes to the study of anchorage of longitudinal reinforcement steel bars in connections of flexural elements in reinforced concrete buildings. Some important researches are investigated showing the advances of the subject in the last decades. An evaluation method of material’s constitutive models, steel and concrete, using the Finite Element Analysis in the software ADINA is proposed, to project verifications according to NBR 6118:2003 and MC CEB-FIP 1990 recommendations. Comparisons between numerical analysis by using a two-dimensional model of exterior beam-column connections and experimental analysis and using existing projects are made. The analysis parameters are the cracking moment and the anchored steel bar tension force in the most requested beam section, compared to the values calculated by analytical methods and/or design expressions, the maximum stresses and strains in points along to anchored steel bar of the beam longitudinal reinforcement and the influence of the normal force. The results show that the assumed simplifications and hypothesis for the numerical model conception are consistent
58

Repair and strengthening of Pre-1970 reinforced concrete corner beam-column joints using CFRP composites

Engindeniz, Murat 13 May 2008 (has links)
The results of an experimental investigation are presented which examine the seismic adequacy of pre-1970 reinforced concrete (RC) corner beam-column joints and the efficacy of carbon fiber-reinforced polymer (CFRP) composites for both pre- and post-earthquake retrofit of such joints. Four full-scale corner beam-column-slab subassemblages built with identical dimensions and pre-1970 reinforcement details were subjected to a reverse-cycle bidirectional displacement history consisting of alternate and simultaneous cycles in the two primary frame directions before and/or after retrofit. Two of the specimens were first subjected to severe and moderate levels of damage, respectively, then repaired by epoxy injection, and strengthened by adding a #7 reinforcing bar within the clear cover at the column inside corner and by externally bonding multiple layers of carbon fabric to form a carbon-epoxy retrofit system. Two other specimens, one of which had a significantly lower concrete compressive strength, were strengthened in their as-built condition. The CFRP scheme was improved in light of the findings as the experimental program progressed. Pre-1970 RC corner beam-column joints were found to be severely inadequate in meeting seismic demands because of column bar yielding, joint shear failure, loss of anchorage of beam bottom bars, failure of column lap-splices, and the resulting loss of stiffness and strength that dominate their behavior even at relatively low interstory drift levels. Bidirectional loading played a significant role in such response. It was shown, however, that such joints can be strengthened easily both before and after earthquake damage by using CFRP composite schemes. Regardless of the level of existing damage and concrete strength, a "rigid" joint behavior up to interstory drift ratios of at least 2.4% and joint shear strength factors ranging from 1.06 to 1.41√MPa were achieved; such shear strength factors are larger than the value of 1.00√MPa recommended for use with seismically designed, code-conforming corner beam-column joints. A ductile beam hinging mechanism was achieved and energy dissipation capacity was improved efficiently for joints with concrete strengths ranging from 26 to 34 MPa. The subassemblage with significantly low-strength concrete (15 MPa) had low overall lateral stiffness and reduced reinforcement anchorages which prevented the formation of beam hinging. In cases of such low-strength concrete, more invasive operations may be required so that the improved joint shear strength can be mobilized. It is recommended that bidirectional loading be always considered in both pre- and post-retrofit evaluation of corner joints.
59

Comportamento de elementos pré-moldados de concreto com ligações semi-rígidas. / Behaviour of concrete precast elements with semi-rigid connections.

Souza, Abner Soares de 01 September 2006 (has links)
Made available in DSpace on 2016-06-02T20:09:04Z (GMT). No. of bitstreams: 1 DissASS.pdf: 3030488 bytes, checksum: a4d23b016b1767d42942fdad295c0fe1 (MD5) Previous issue date: 2006-09-01 / Universidade Federal de Minas Gerais / The behaviour of reinforced concrete precast beams is strongly influenced by the flexural stiffness of its beam-column connections, wherein there is interdependence between the nonlinearity of the moment-curvature relationship along the beam and the non-linearity of the moment-rotation relationship of the beam-column connections. In most of the existing researches on semi-rigid connections in precast structures, the main focus lays on the characterization of the flexural stiffness by performing experimental tests on isolated models of beam-column connections instead of tests on sub-frames, comprising beam and connections. In this research an experimental procedure was developed, wherein different theoretical equations based on the fixity factor of the connections were combined, allowing the integration between the stiffness of the reinforced concrete beam with the flexural stiffness of the beam-column connections. Therefore, by using this procedure it was possible to evaluate the semi-rigid behaviour of the beam-column connection, highlighting the possibility of carrying out just one test for the precast beam with its connections. The analyses of the experimental results indicate that the studied connection was capable of absorbing around 53% of the elastic beam-end moment at the ULS, compared with the situation of a full restrained connector, implying the increase of 170% of the positive mid-span moment of the beam. This level of semi-rigid behaviour for the beam-column connection can affect the global stability of skeletal precast concrete structures with more than five storeys in height. For this reason, the present research shows the need for further studies with the purpose of enhancing the analysis and the design of precast concrete structures for multi-storey buildings. / O comportamento das vigas pré-moldadas de concreto armado é fortemente influenciado pela rigidez à flexão das ligações viga-pilar, existe uma interdependência entre a não linearidade da relação momento-curvatura ao longo da viga pré-moldada com a não linearidade da relação momento-rotação nas ligações viga-pilar. A maioria das investigações experimentais existentes sobre ligações semi-rígidas em estruturas pré-moldadas, tanto na literatura nacional quanto internacional, têm enfatizado seus estudos na caracterização da rigidez à flexão de maneira isolada, não realizando ensaios do comportamento conjunto das vigas pré-moldadas com as suas ligações. Desenvolve-se nesta pesquisa um procedimento experimental onde se procurou integrar diversos equacionamentos teóricos com base no fator de restrição aos giros na ligação, os quais permitiram integrar parâmetros de rigidez da ligação e da viga. Desta forma, com base nos resultados experimentais em um único ensaio de um modelo de viga com ligações viga-pilar, foi possível se estimar o engastamento parcial nas ligações viga-pilar. A partir dos resultados experimentais, a ligação viga-pilar foi capaz de absorver cerca de 53% dos momentos elásticos na extremidade da viga, havendo assim um acréscimo de 170% no momento positivo no centro da viga para a situação de projeto no ELU. Este engastamento parcial pode afetar sensivelmente a estabilidade global de estruturas pré-moldadas com mais de 5 pavimentos. Por esta razão, o presente estudo aponta para a necessidade de mais pesquisas nesta área, com o objetivo de possibilitar projetos mais adequados e seguros de estruturas pré-moldadas em esqueleto para múltiplos pavimentos.
60

Estudo teórico-experimental de ligação viga-pilar com consolo metálico embutido em estruturas pré-moldadas de concreto / Estudo Teórico-Experimental de Ligação Viga-Pilar com Consolo Metálico Embutido em Estruturas Pré-Moldadas de Concreto

Bachega, Luís Augusto 14 February 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:18Z (GMT). No. of bitstreams: 1 5038.pdf: 12517869 bytes, checksum: 373976ca3c8851e35a4dbd3dd53ff661 (MD5) Previous issue date: 2013-02-14 / Financiadora de Estudos e Projetos / This study aimed to analyze the structural behavior of a beam-column connection with embedded steel member for precast concrete with no current use still in Brazil. Based on the literature review about hidden corbels found in international technical references, a type of hidden corbel with embedded steel section (so called billet) was selected for this research. Although there are many different analytical models for the design of the billet within the available technical literature, the focus of this research was on the revised models found in the most recent design manuals PCI (2010) and FIB (2011). In addition to the analytical study an experimental investigation was conducted, wherein isolated column members with billet corbels were tested primarily to a full scale test of a sub-frame with two beams six meters long and with a central column assembled in cruciform shape. For the isolated model, named PI Model (Isolated steel corbel), the behavior of the steel corbel and its interaction with the column were evaluated. For the full scale test, named LI Model (connection zone model), the behavior of the connection zone and the behavior of the beam were studied interacting together. For both the theoretical and the experimental studies, the selected billet consisted of a rectangular hollow section of 200 mm x 100 mm x 10 mm in height, width and thickness, respectively. For the PI Model test, the billet showed a rigid behavior and it was capable of resist an applied load of 700 kN with no damage within the concrete of the column. For the case of LI Model, the experimental study analyzed the behavior of the whole connection zone, comprising both the steel corbel and the end of the beam near the corbel. For this case, the connection behaved as rigid until the applied shear force at the connection reached between 239,5 kN and 238,3 kN, for which the flexural stiffness of the connection acted as rigid, with fixity factors of 1.0 and 0.96, for the left and right connections, respectively. The failure of the model occurred at the cast in place topping of the composite beam when the shear force reached 473.5 kN. The comparison between the experimental results with the theoretical values demonstrated that the isolate billet showed compatible resistance with the expected but that the region of the beam top end showed premature failure due to lack of reinforcement in the region of the end of the beam. It is believed that this effect occurred because of the fact that the detailing followed from studies conducted in the UK is suitable for hinged connections while the connection analyzed in this research comprised of continuous negative reinforcing bars passing through the columns within the cast in place topping of the composite precast beam. Finally, this study presents further recommendations for improvements of the reinforcement detailing of the precast beam. / O estudo teve como objetivo principal analisar o comportamento estrutural de uma ligação viga-pilar com Consolo Metálico Embutido para estruturas pré-moldadas de concreto com uso ainda não corrente no Brasil. Após uma revisão bibliográfica sobre os principais consolos metálicos embutidos encontrados nas referências técnicas internacionais, escolheu-se um tipo de consolo metálico embutido que emprega um perfil metálico (chamado tarugo metálico). A revisão bibliográfica permitiu encontrar na literatura técnica e acadêmica vários modelos analíticos para o dimensionamento do perfil metálico, mas o estudo no presente trabalho se concentrou nos modelos revisados encontrados nos manuais do PCI (2010) e da FIB (2011). Além do estudo analítico, foram realizados ensaios exploratórios primeiramente em consolos no pilar isolado e em seguida foi ensaiado um modelo em escala real com duas vigas de seis metros e um pilar central. No primeiro modelo, denominado modelo de ensaio PI (Pilar Isolado), estudou-se o comportamento isolado do consolo e sua interação junto ao pilar. No segundo modelo, denominado modelo de ensaio LI (Ligação), estudou-se o comportamento da região da ligação e de interação com a viga. Para o estudo teórico-experimental, o tarugo metálico escolhido teve perfil retangular vazado de 200 mm x 100 mm x 10 mm de altura, largura e espessura respectivamente. No ensaio do modelo PI, o consolo metálico apresentou um comportamento rígido e foi capaz de suportar uma carga aplicada de 700 kN sem danos dentro do concreto do pilar. Já no caso do modelo LI, o estudo experimental analisou o comportamento conjunto da ligação, envolvendo tanto o consolo metálico quanto a extremidade da viga próximo ao consolo. Para este caso, a ligação se comportou como rígida para uma força cortante entre 239,5 kN e 238,3 kN, para a qual se estimou um momento de engastamento variando entre 1,0 e 0,96 para a ligação da esquerda e direita, respectivamente. Ocorreu ruptura por cisalhamento na capa de concreto na extremidade da viga quando a força cortante na seção atingiu 473,5 kN. A comparação dos resultados experimentais com os valores teóricos de cálculo demonstrou que o consolo isolado apresentou resistência compatível com o esperado, mas que a região da capa na extremidade da viga apresentou uma falha prematura devido à falta de armadura de costura na região da extremidade da viga. Acredita-se que este efeito tenha ocorrido em virtude do fato de que o detalhamento seguido a partir de estudos realizados no Reino Unido seja indicado para ligações articuladas, enquanto a ligação analisada consistiu de uma ligação com continuidade na armadura negativa. Por esta razão, este estudo apresenta recomendações para melhorias no detalhamento da viga.

Page generated in 0.0577 seconds