Spelling suggestions: "subject:"biosusceptometria."" "subject:"biosusceptometry.""
1 |
Otimização e aperfeiçoamento BAC pra estudos envolvendo o trato gastrintestinalAgostinho, Marcelo Rodrigues [UNESP] 27 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:26Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-27Bitstream added on 2014-06-13T20:13:53Z : No. of bitstreams: 1
agostinho_mr_me_botib.pdf: 487460 bytes, checksum: e3edd62113cd3612c5b439f526eb253b (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A utilização de técnicas não invasivas, de baixo custo e inócuas ao indi-víduo proporcionam um grande desafio para o estudo do trato gastrintestinal. Métodos biomagnéticos como a BAC trazem todas essas vantagens e incluem a possibilidade de expansão para novos estudos, arranjos instrumentais e mo-delos biológicos. A consolidação dessa técnica nos últimos anos permitiu a ampliação dos estudos na área farmacêutica, avaliações após alterações nas condições fisiológicas e mesmo após administração de drogas, fornecendo subsídios para uma melhor interpretação dos parâmetros motores do trato gas-trintestinal. As imagens de traçadores e marcadores magnéticos no trato gas-trintestinal proporcionadas pela BAC foi um importante aspecto explorado, no entanto, houve a necessidade de aperfeiçoar a instrumentação para obter me-lhores e também novos resultados. A proposta de implementação de algumas melhorias nesta instrumentação através de implementação de novo arranjo de bobina excitadora, cancelamento de ruído respiratório e nova eletrônica de de-tecção permitiram que os dados in vitro e in vivo refletiram numa melhor quali-dade de sinais e imagens obtidos por este técnica. A BAC multi-sensores é uma ferramenta valiosa com vasta aplicabilidade para aplicação em tecnologia farmacêutica e em fisiologia do trato gastrintestinal / The use of non-invasive techniques, at low cost and harmless to the indi-vidual, provides a great challenge for the study of the gastrointestinal tract. Biomagnetic methods such as the BAC have all these advantages and also include the possibility of expanding to new studies, to instrumental ar-rangements and to biological models. The consolidation of this technique in re-cent years allowed the extension of studies in the pharmaceutical field, after rating changes in physiological conditions and even after drug administration, supporting a better interpretation of the motor parameters of the gastrointestinal tract. The images of tracers and magnetic markers in the gastrointestinal tract offered by the BAC was an important aspect explored. However, there was a necessity of improving the equipment in order to obtain new and better re-sults. The proposal to implement some improvements in this equipment through implementation of the new exciter coil arrangement, the cancellation of the noise of breathing, and the new electronics of detection have allowed that the data in vitro and in vivo reflected a better quality of signals and images obtained by this technique. The BAC multi-sensors is a valuable tool with wide applica-bility to pharmaceutical technology and physiology of the gastrointestinal tract
|
2 |
Otimização e aperfeiçoamento BAC pra estudos envolvendo o trato gastrintestinal /Agostinho, Marcelo Rodrigues. January 2011 (has links)
Orientador: José Ricardo de Arruda Miranda / Banca: Eder Rezende / Banca: Fabiano Carlos Paixão / Resumo: A utilização de técnicas não invasivas, de baixo custo e inócuas ao indi-víduo proporcionam um grande desafio para o estudo do trato gastrintestinal. Métodos biomagnéticos como a BAC trazem todas essas vantagens e incluem a possibilidade de expansão para novos estudos, arranjos instrumentais e mo-delos biológicos. A consolidação dessa técnica nos últimos anos permitiu a ampliação dos estudos na área farmacêutica, avaliações após alterações nas condições fisiológicas e mesmo após administração de drogas, fornecendo subsídios para uma melhor interpretação dos parâmetros motores do trato gas-trintestinal. As imagens de traçadores e marcadores magnéticos no trato gas-trintestinal proporcionadas pela BAC foi um importante aspecto explorado, no entanto, houve a necessidade de aperfeiçoar a instrumentação para obter me-lhores e também novos resultados. A proposta de implementação de algumas melhorias nesta instrumentação através de implementação de novo arranjo de bobina excitadora, cancelamento de ruído respiratório e nova eletrônica de de-tecção permitiram que os dados in vitro e in vivo refletiram numa melhor quali-dade de sinais e imagens obtidos por este técnica. A BAC multi-sensores é uma ferramenta valiosa com vasta aplicabilidade para aplicação em tecnologia farmacêutica e em fisiologia do trato gastrintestinal / Abstract: The use of non-invasive techniques, at low cost and harmless to the indi-vidual, provides a great challenge for the study of the gastrointestinal tract. Biomagnetic methods such as the BAC have all these advantages and also include the possibility of expanding to new studies, to instrumental ar-rangements and to biological models. The consolidation of this technique in re-cent years allowed the extension of studies in the pharmaceutical field, after rating changes in physiological conditions and even after drug administration, supporting a better interpretation of the motor parameters of the gastrointestinal tract. The images of tracers and magnetic markers in the gastrointestinal tract offered by the BAC was an important aspect explored. However, there was a necessity of improving the equipment in order to obtain new and better re-sults. The proposal to implement some improvements in this equipment through implementation of the new exciter coil arrangement, the cancellation of the noise of breathing, and the new electronics of detection have allowed that the data in vitro and in vivo reflected a better quality of signals and images obtained by this technique. The BAC multi-sensors is a valuable tool with wide applica-bility to pharmaceutical technology and physiology of the gastrointestinal tract / Mestre
|
3 |
Sistema multiparticulado magnético: desenvolvimento e avaliação In Vivo através da biossusceptometria ACOliveira, Giselle Faria [UNESP] 25 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-02-25Bitstream added on 2014-06-13T20:05:27Z : No. of bitstreams: 1
oliveira_gf_dr_arafcf.pdf: 1597111 bytes, checksum: 8e048dc196c11ce687d14ea7159987ad (MD5) / Universidade Estadual Paulista (UNESP) / Neste estudo foi desenvolvido um sistema multiparticulado magnético (SMM) à base de quitosana (QS), pectina (PC) e acetoftalato de celulose (CAP), pelo método da coacervação complexa. O sistema contém um glicocorticóide, a triancinolona (TC), e, como material magnético, a ferrita (F). Em estudos anteriores, este SMM mostrou-se promissor para conduzir a liberação modificada de fármacos para a região colônica. Segundo análises in vitro, ele associou a liberação pH-dependente à liberação enzimática, típica do ambiente colônico. Entretanto, devido à complexidade do trato gastrintestinal (TGI), torna-se essencial que formas farmacêuticas desenvolvidas para liberação alvo-específica sejam avaliadas in vivo, para que se possa estabelecer uma correlação in vitro/in vivo adequada. Baseado nesses fatos, o objetivo deste trabalho foi o monitoramento do trânsito gastrintestinal (TG) do sistema proposto até sua chegada ao cólon, através de uma técnica não invasiva, livre de radiação, a Biosusceptometria de Corrente Alternada (BAC), que pudesse avaliar o trânsito gastrintestinal (TG) do SMM em voluntários saudáveis em jejum e no estado alimentado. Foram também realizadas análises do perfil de liberação in vivo da TC. Os resultados obtidos mostraram que o sistema desenvolvido foi capaz de produzir campo magnético de intensidade suficiente para ser detectado e que a BAC foi capaz de monitorar o trânsito gastrintestinal do SMM até sua chegada ao cólon. O estado pós-prandial influenciou significativamente o esvaziamento gástrico, sendo o tempo médio de 107,5 min ± 43,37 min no estado de jejum e de 260min ± 67,64 min no estado alimentado. Além do esvaziamento gástrico mais demorado no estado alimentado, o trânsito pelo intestino delgado e a chegada ao cólon também foram influenciados pelo estado pós-prandial. Não foi possível estabelecer correlação... / In this study a magnetic multiparticulate system (MMS) based on chitosan (CS), pectin (PC) and cellulose acetophtalate (CAP) was developed by means of a complex coacervation method. The system contains a glucocorticoid, triamcinolone (TC), and ferrite (F) as magnetic material. In earlier studies, this MMS showed to be a promising system for modified drug release to target the colonic region. As in vitro analyses proved, it was able to associate pHdependent and enzymatic controlled, typical from the colonic environment, drug releases. However, due to the complexity of the gastrointestinal tract (GIT), it is essential that pharmaceutical dosage forms developed to perform target specific drug release may be evaluated also in vivo, in order to establish an adequate in vitro/in vivo correlation. Based on these issues, the aim of this work was the monitoring of the gastrointestinal transit (GT) of the proposed system until it reaches the colon, by means of a non-invasive, radiation free technique, namely the Alternate Current Biosusceptometry (ACB), which could evaluate the MMS transit in healthy volunteers both in fasting and fed states. Analyses of the in vivo TC release profile were also carried out. The results showed that the developed system was able to generate magnetic field strong enough to be detected and that ACB was efficient to monitoring the MMS transit until its arrival in the colon. The postprandial state influenced significantly the gastric emptying, being 260.0 min ± 67.64 min the mean time for the fed state and 107.5 min ± 43.37 min for the fasting state. Additionally to a longer gastric emptying time, the transit within the small intestine and the arrival in the colon were also influenced by the postprandial state. It was not possible to establish a valid in vivo/in vitro correlation between the drug released profiles... (Complete abstract click electronic access below)
|
Page generated in 0.0618 seconds