Spelling suggestions: "subject:"blood back"" "subject:"blood band""
21 |
Avaliação da viabilidade financeira do banco do sangue de cordão umbilical do Hemocentro de Ribeirão Preto / Evaluation of financial viability of the umbilical cord blood bank of the Hemocentro de Ribeirão PretoAna Paula Rocha Diniz Zanelli 02 March 2017 (has links)
Introdução. As células progenitoras hematopoéticas (CPH) têm sido utilizadas no tratamento de algumas doenças malignas hematológicas e de desordens hematopoéticas. Dentre estas células estão as CPHs provenientes de cordão umbilical e placentário (SCUP). Para coleta e armazenamento destas células foram criados os Bancos de Sangue de Cordão Umbilical e Placentário (BSCUP). No Brasil existe a rede BrasilCord e o BSCUP do Hemocentro de Ribeirão Preto é um dos que compõem esta rede. Objetivo. Avaliar a viabilidade financeira de um banco de sangue de cordão umbilical e placentário público comparando os custos de seus procedimentos com os valores ressarcidos definidos pela tabela SUS. Metodologia: Este estudo utilizou a metodologia de Custeio Baseado em Atividades (Activity-Based Costing - ABC), que procura reduzir as distorções provocadas pelo rateio arbitrário dos custos indiretos utilizando direcionadores de custos. Foram avaliados os custos diretos e indiretos da coleta, transporte, processamento, testagem e criopreservação de CPH proveniente de SCUP no primeiro semestre de 2015. Para os custos indiretos foram definidos os direcionadores de custo. Resultados Os resultados mostram que o BSCUP do Hemocentro de Ribeirão Preto foi deficitário no primeiro semestre de 2015. O déficit apurado por unidade foi de R$1.155,69 para o processamento semiautomatizado e R$1.703,78 para o processamento automatizado. O déficit total no período foi de R$ 100.376,50 quando 50 unidades foram processadas utilizando o método semiautomatizado e 25 pelo método automatizado. Conclusão. O valor ressarcido pelo SUS não cobre os gastos do BSCUP do Hemocentro de Ribeirão Preto. Isso pode ser atribuído a várias causas como: sistemática de pagamento pelo SUS apenas pelo produto criopreservado, elevados índices de rejeição das doadoras na maternidade e de descarte das unidades coletadas, embora este último seja menor que o descrito na literatura, e o custo do armazenamento em longo prazo. Os custos do BSCUP são menores que os descritos na literatura e poderiam ser reduzidos com melhorias de processos de gestão e aumento do número de unidades criopreservadas, bem como, por meio de descentralização de coletas para processamento centralizado. / Introduction. Hematopoietic progenitor cells (HPC) are being used in some hematologic malignancies and hematopoietic disorders treatment. Among these cells are the HPCs from umbilical blood cord (UCB). Umbilical cord blood banks were created to collect and store these cells. In Brazil there is a net called Brasilcord and the umbilical cord blood bank (UCBB)of the Hemocentro de Ribeirão Preto belongs to this net. Objective. To evaluate the financial viability of a public umbilical cord blood bank and compare the costs from its procedure with the values reimbursed defined by the SUS table. Methodology.This study used the ActivityBased Costing, which tries to reduce distortions caused by arbitrary apportionment of indirect costs using cost drivers. Direct and indirect costs of collection, transport, processing, testing and cryopreservation of HPCs from umbilical cord blood were evaluated. Cost drivers were defined for indirect costs. Results. The results showed that there was a deficit in the UCBB of the Hemocentro de Ribeirão Preto in the first semester of 2015. The deficit was R$1.155,69 when the unit was processed by the semi-automated method and R$1.703,78 when it was processed by an automated method. The total deficit in the period was R$100.376,50 as 50 units were processed by a semi-automated method and 25 by an automated method. Conclusion. The amount reimbursed by SUS does not cover the UCBB of Hemocentro de Ribeirão Preto expenses. This can be attributed to several causes such as: systematic of reimbursement used by SUS that only cryopreserved units are payed, high percentage of deferral in the maternity and of discard of collected units, although this latter is smaller than that described in the literature and the cost of storage of the units for long periods. The costs of UCBB are lower than that described in the literature and could be reduced with improvements in managing process and increase the number of cryopreserved units as well as decentralization of collections for centralizes processing.
|
22 |
Associação entre os níveis citoplasmáticos da enzima aldeído desidrogenase (ALDH) e a capacidade proliferativa \"in vitro\" das células progenitoras hematopoéticas de sangue de cordão umbilical e placentário / Association between the cytoplasmic levels of dehydrogenase aldehyde enzyme (ALDH) and the \"in vitro\" proliferative capacity of hematopoietic stem cells of umbilical cord bloodPaula Renata Machado Passos 22 June 2018 (has links)
A utilização das células progenitoras hematopoéticas (CPH) obtidas do sangue de cordão umbilical e placentário (SCUP) apresenta vários benefícios para o transplante de CPH em comparação às células provenientes de outras fontes. Dentre eles, a maior disponibilidade e a maior imaturidade imunológica das CPH, o que permite certa flexibilidade nos critérios de compatibilidade entre doador e receptor e uma menor taxa de reação do enxerto-versus-hospedeiro. A legislação brasileira e órgãos internacionais exigem a realização de vários testes para garantir a qualidade do produto hemoterápico contendo CPH a ser transplantado. O objetivo deste estudo foi confirmar que o teste para quantificação de CPH com elevada atividade da enzima ALDH1(ALDHbr) pode ser considerado um teste de adequado ou seja, é capaz de predizer quais produtos tem melhor capacidade de repopular a medula óssea do recipiente após o transplante. Para isso, foram utilizadas 40 unidades de SCUP coletadas e processadas pelo Banco de Sangue de Cordão Umbilical e Placentário do Cetebio / Fundação Hemominas. As unidades foram processadas por método automatizado e amostras do creme leucocitário (buffy coat) foram coletadas para a realização da quantificação de células ALDHbr, quantificação de células CD34+, ensaio clonogênico (CFU), hemograma e cálculo do total de células nucleadas (TCN). A citometria de fluxo foi utilizada para a quantificação das CPH ALDHbr e CD34+ e das subpopulações CD45dim e CD38+. Outras informações como idade materna, idade gestacional e sexo do recém-nascido também foram coletadas para descrição das unidades. Para verificar a viabilidade da utilização do teste de ALDH pelos BSCUP foi realizado o levantamento do seu custo. A capacidade funcional das CPH em proliferar e se diferenciar em tecido hematopoético foi avaliada por meio do ensaio clonogênico. Detectou-se correlação entre a quantidade de células ALDHbr e o número de colônias no ensaio clonogênico (p<0,001), entre o número de células ALDHbr e de células CD34+ (p=0,001) e entre o número de colônias no ensaio clonogênico e o número de células CD34+ (p<0,001). A imunofenotipagem mostrou que 46,25% das células ALDHbr eram CD45dimCD38+CD34+. Os dados sugerem que a quantificação de células ALDHbr em unidades de SCUP pode ser considerada teste adequado, de baixo custo, de execução simples, rápida e menos dependente do operador em relação ao ensaio clonogênico. / The use of the umbilical cord blood cells presents numberless benefits when compared to the cells from different sources. Among them, the ease of availability, the bigger immunological immaturity, which allows some flexibility in the compatibility between donor and receptor and less induction of reaction of graft-versus-host. The Brazilian legislation and international organizations demand the practice of various tests to guarantee the quality of the product to be transplanted. The aim of this research was to confirm that the test used to quantify ALDHbr cells can be considered a power test, meaning that it tests the ability to repopulate the bone marrow after transplant. For this study, it has been used 40 units of SCUP collected and processed by the Cetebio Umbilical Cord Blood Bank - Fundação Hemominas. The units were processed by the automatized method and the samples of the final product (buffy coat) were collected for the quantification of ALDHbr cells, quantification of CD34+ cells, clonogenic essay (CFU), hemogram and the total number of nucleated cells (TNC). It was used the flow cytometry to perform ALDH and CD34+ tests. Besides that, it was also performed the association of antibodies anti-CD34, anti-CD45 and anti-CD38 for the immunophenotyping of the units. Other information such as maternal age, fertilization age and the newborn gender were also collected for description of the units. In order to verify the viability of the use of the ALDH test by BSCUP its costs were calculated, as well as of the clonogenic essay. The results showed a significant correlation between ALDHbr cells and the clonogenic essay (p<0.001), between ALDHbr and CD34+ cells (p=0,001) and between the clonogenic essay and the quantification of CD34+ cells (p<0,001). The immunophenotyping revealed that 46,25% of ALDHbr cells were CD45dimCD38+CD34+. The data indicated that the quantification of ALDHbr cells in the SCUP units can be considered a powerful and low cost procedure, of easier and quicker execution and less operator dependent.
|
23 |
Factors determining the composition of a public cord blood stem cell bank including HLA diversityMellet, Juanita January 2013 (has links)
The human leukocyte antigen (HLA) is the most polymorphic region in the human genome and accounts for more than 10% of human diversity. This region plays an important role in matching donors and recipients for transplantation. The South African Bone Marrow Registry (SABMR) does not reflect the demographics of the South African population. The large number of polymorphisms resulting from HLA diversity in the Black South African population and their limited representation in the SABMR reduce the chances of finding adequate matches between donors and recipients in this group. Umbilical cord blood is an alternative to bone marrow for the treatment of fatal diseases. Less strict HLA matching is required due to the naive nature of the T cells in cord blood. A public umbilical cord blood bank is a necessity in trying to cater for the diverse population in South Africa. However, the ethnic diversity of the South African population poses a great challenge in constituting a public umbilical cord blood bank that is representative of the entire population. The Roche designed next generation sequencing (NGS) high resolution (HR) HLA typing kit enables sequencing of additional HLA exons and could improve the degree of matching between individuals to ultimately decrease adverse reactions. An extensive study of the literature was performed to establish the demographics, linguistics, and HLA diversity of the South African population to determine how a public cord blood bank should be constituted. In addition, HLA genotyping was performed by 454 NGS on 20 samples that had previously been HLA typed by conventional methods. The 454 NGS technique made use of a Roche designed medium and high resolution HLA typing kit to genotype the samples. It was possible to assign accurate genotypes to 95.5% of the loci of interest for the total number of 20 samples using the MR kit, compared with 98.5% using the HR kit. In conclusion, the present study indicates the extreme HLA diversity in the South African population, and therefore, recommends constituting the first public umbilical cord blood bank in Gauteng on the basis of race or major ethnic groupings. A minimum number of 10 000 cord blood units is needed to initiate the bank. Furthermore, the 454 NGS platform together with the HR HLA typing kit display potential as an alternative method to be used in a public cord blood bank, as well as routine clinical and diagnostic laboratories, to ultimately improve HLA matching between donors and recipients. / Dissertation (MSc)--University of Pretoria, 2013. / gm2014 / Immunology / unrestricted
|
24 |
Qualificação das unidades de SCUP criopreservadas no banco de sangue de cordão umbilical e placentário da Fundação HEMOPE no período de dezembro de 2014 a junho de 2017 / Qualification of cryopreserved SCUP units in the umbilical cord and placental blood bank of the HEMOPE Foundation from December 2014 to June 2017Costa, Ana Maria do Nascimento 07 November 2018 (has links)
Qualificar as primeiras unidades de Sangue de Cordão Umbilical e Placentá- rio (SCUP) criopreservadas no Banco de Sangue Umbilical e placentário da Fundação de Hematologia e Hemoterapia de Pernambuco (BSCUP/HEMOPE), no período de dezembro de 2014 a junho de 2017. Justificativa: O sangue do cordão é rico em células progenitoras hematopoéticas (CPH), utilizado para transplante e tratamento de patologias benignas e malignas. Avaliar as primeiras unidades coletadas no BSCUP/ HEMOPE será de grande valia para sua caracterização, planejamento de ações de melhoria do processo, contribuindo para o aumento da eficácia dos transplantes. Métodos: Foram triadas gestantes sem histórico de diagnóstico para doenças transmissíveis pelo sangue, com gestação terminada em recém-nascido (RN) vivo; caracterizadas através das variáveis sociodemográficas: idade, idade gestacional, antecedentes obstétricos e cor da pele dos RN foram caracterizados pelas variáveis explicativas: Gênero e Peso; as amostras das mães foram coletadas no dia do parto ou em até 48h após. O tempo entre o término da coleta e o início da criopreservação da unidade das CPH não excedeu 48 horas. As unidades de SCUP foram avaliadas quanto ao volume, total de células nucleadas (TCN), quantificação de células CD 34+, contagem de eritroblastos viabilidade celular e contaminação microbiológica. Neste estudo foi avaliada a variável \"unidades adequadas ao uso em relação ao peso do receptor, tomando com o base o TCN e o peso de um provável receptor, assim categorizados: unidades <12,5 x10e8 para peso 12,5 para peso >50kg; Resultados: Volume Inicial (ml):(min.50,0; max.166,80); Volume final(mL): (min.19,07;max.21,75); TCN pré (x108): (min.6,0;max.27,80);TCN pós(x108): (min.5,0; max.22,6); Recuperação Celular (%): (min.0,67; max.39,50); CD34+(x106):(min.0,67;max.39,50);Viabilidade(%): (min.71,35max.100); Conclusão: Das 113 unidades armazenadas, 89 (78,76%) atendem a receptores < 50kg (crianças) e 24 (21,24%) atendem a receptores >50k (adultos). O inventário apresentou resultados em conformidades com o especificado na legislação vigente, portanto, qualificadas para atender à demanda transfusional de transplantes de CPH. / To qualify the first units of cryopreserved Umbilical Cord and Placental Blood (SCUP) in the Umbilical and Placental Blood Bank of the Hematology and Hemotherapy Foundation of the State of Pernambuco (BSCUP / HEMOPE), from December 2014 to June 2017 Rationale: Cord blood is rich in hematopoietic progenitor cells (HPC), used for transplantation and treatment of benign and malignant pathologies. Evaluating the first units collected in the BSCUP / HEMOPE will be of great value for its characterization, planning of actions to improve the process, contributing to increase the efficiency of transplants. Methods: Pregnant women with no history of diagnosis for blood-borne diseases were screened, with gestation terminated in live newborn (NB); characterized by the sociodemographic variables: age, gestational age, obstetric history and skin color, NB were characterized by the explanatory variables: Gender and Weight; the samples of the mothers were collected on the day of delivery or within 48 hours after delivery. The time between the end of the collection and the beginning of the cryopreservation of the MHC unit did not exceed 48 hours. SCUP units were evaluated for volume, total nucleated cells (TNC), CD34 + cell count, cell viability erythroblast counts, and microbiological contamination. In this study, the variable \"units suitable for use in relation to the weight of the receptor\" was evaluated, taking as base the TNC and the weight of a probable receiver, as follows: units <12.5 x10e8 for weight 12 , 5 for weight> 50 kg; Results: Initial volume (ml): (min.50.0, max.166.80); Final volume (mL): (min.19.07, max.21.75); TCN pre (x108): (min.6,0; max.27,80); TCN post (x108): (min.5,0; max.22,6); Cellular Recovery (%): (min.0.67, max.39,50); CD34 + (x106): (min.0.67, max.39.50); Viability (%): (min.71,35max.100); : Of the 113 stored units, 89 (78.76%) attend to receptors <50kg (children) and 24 (21.24%) attend receptors> 50k (adults). Conclusion: The inventory presented results in compliance with that specified in current legislation, therefore, qualified to meet the transfusional demand for HPC transplants.
|
Page generated in 0.0535 seconds