• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A systematic approach to fireside boiler tube investigations

Broodryk, Gideon Jacobus 31 August 2016 (has links)
Submitted for t he MASTERS OF SCIENCE Chemistry in the Department of Chemistry UNIVERSITY of the Witwatersrand December 1995
2

Recovery boiler superheater corrosion - solubility of metal oxides in molten salt

Meyer, Joseph Freeman 15 April 2013 (has links)
The recovery boiler in a pulp and paper mill plays a dual role of recovering pulping chemicals and generating steam for either chemical processes or producing electricity. The efficiency of producing steam in the recovery boiler is limited by the first melting temperature of ash deposits that accumulate on the superheater tubes. Above the first melting temperature, the molten salt reacts with the protective oxide film that develops and dissolves it. The most protective oxide is determined by evaluating how little it dissolves and how its solubility changes in the molten salt. Solubility tests were done on several protective oxides in a known salt composition from a recovery boiler that burns hardwood derived fuel. ICP-OES was used to measure concentration of dissolved metal in the exposure tests while EDS and XRD were used to verify chemical compositions in exposure tests. NiO was found to be the least soluble oxide while Cr₂O₃ and Al₂O₃ had similar solubility with Fe₂O₃ being less soluble than Cr₂O₃ but more soluble than NiO. Exposure tests with pure metals and selected alloys indicated that even though Fe₂O₃ has little solubility, it is not a protective oxide and causes severe corrosion in stainless steels. The change in performance of iron based alloys was due to the development of a negative solubility gradient for Fe₂O₃ where Fe₂O₃ precipitated out of solution and created a continuous leaching of oxide. Manganese was found to be beneficial in stainless steels but its role is still unknown. Nickel based alloys were found to be least corroded due to nickel's low solubility and because it did not form a negative solubility gradient.
3

Effect of different types of coal in thermal performance of economisers in power stations.

Aphane, Manthulane Hezekiel. January 2014 (has links)
M. Tech. Mechanical Engineering. / Discusses the economiser design to absorb as much heat as possible within the flue gases. Fly ash particles, a product of combustion, entrained in the flue gas of the furnace part of the boiler in coal fired boilers, affect economiser thermal performance by causing erosive wear and scale on the outer surface of the economiser tubes along the flow path, which in turn increases the thermal resistance characterisation of coals in relation to combustion behaviour traditionally relies on staged quenching of the reaction and subsequent gravimetric analysis of the remaining sample. Three typical steam-raising coals are compared with regard to reactivity and broadly examined relative to their petro-graphic constituents and other standard laboratory tested samples. A significant correlation was found between the ignition temperature and the hydrogen or carbon ratio determined by the ultimate analysis, inter alia, the erosion rate and the heat transfer rate.
4

Formation and Quantification of Corrosion Deposits in the Power Industry

Namduri, Haritha 05 1900 (has links)
The presence of deposits on the secondary side of pressurized water reactor (PWR) steam generator systems is one of the main contributors to the high maintenance costs of these generators. Formation and transport of corrosion products formed due to the presence of impurities, metals and metallic oxides in the secondary side of the steam generator units result in formation of deposits. This research deals with understanding the deposit formation and characterization of deposits by studying the samples collected from different units in secondary side system at Comanche Peak Steam Electric Station (CPSES). Fourier transform infrared spectrophotometry (FTIR), scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) have been used for studying the phases, morphologies and compositions of the iron oxides formed at Unit 1 and Unit 2 of secondary side of steamgenerator systems. Hematite and magnetite were found to be the dominant phases of iron oxides present in the units. Fe, Cr, O, Ni, Si, Cl and Cu were found in samples collected from both the units. A qualitative method was developed to differentiate iron oxides using laser induced breakdown spectroscopy (LIBS) based on temporal response of iron oxides to a high power laser beam. A quantitative FTIR technique was developed to identify and quantify iron oxides present in the different components of the secondary side of the steam generator of CPSES. Amines are used in water treatment to control corrosion and fouling in pressurized water reactors. CPSES presently uses an amine combination of dimethylamine (DMA), hydrazine and morpholine to control the water chemistry. Along with the abovementioned amines, this study also focuses on corrosion inhibition mechanismsof a new amine DBU (1, 8-diazabicyclo [5.4.0] undec-7-ene). Electrochemical impedance spectroscopy and polarization curves were used to study the interaction mechanism between DBU solution and inconel alloys 600 and 690 at steamgenerator operating temperatures and pressures. Of all the amines used in this study (DMA, DBU, ETA, and morpholine), DMA was more effective at keeping the passive film formed on the alloy 600 surface from failing at both ambient and high temperatures. Morpholine was found result in higher corrosion resistance compared to the other amines in case of alloy 690.
5

Characterization of Iron Oxide Deposits Formed at Comanche Peak Steam Electric Station

Namduri, Haritha 05 1900 (has links)
The presence of deposits leading to corrosion of the steam generator (SG) systems is a major contributor to operation and maintenance cost of pressurized water reactor (PWR) plants. Formation and transport of corrosion products formed due to the presence of impurities, metallic oxides and cations in the secondary side of the SG units result in formation of deposits. This research deals with the characterization of deposit samples collected from the two SG units (unit 1 and unit 2) at Comanche Peak Steam Electric Station (CPSES). X-ray diffraction (XRD), Fourier transform infrared spectrophotometry (FTIR), scanning electron microscopy (SEM), and energy dispersive spectroscopy (EDS) techniques have been used for studying the compositional and structural properties of iron oxides formed in the secondary side of unit 1 and unit 2. Magnetite (Fe3O4) was found to be predominant in samples from unit 1 and maghemite (g-Fe2O3) was found to be the dominant phase in case of unit 2. An attempt has been made to customize FTIR technique for analyzing different iron oxide phases present in the deposits of PWR-SG systems.
6

Flow Accelerated Corrosion Experience at Comanche Peak Steam Electric Station

Nakka, Ravi Kumar 05 1900 (has links)
Flow accelerated corrosion (FAC) is a major concern in the power industry as it causes thinning of the pipes by the dissolution of the passive oxide layer formed on the pipe surface. Present research deals with comparing the protection offered by the magnetite (Fe3O4) versus maghemite (γ-Fe2O3) phases thickness loss measurements. Fourier transform infrared spectroscopy (FTIR) is used in distinguishing these two elusive phases of iron oxides. Representative pipes are collected from high pressure steam extraction line of the secondary cycle of unit 2 of Comanche Peak Steam Electric Station (CPSES). Environmental scanning electron microscopy (ESEM) is used for morphological analysis. FTIR and X-ray diffraction (XRD) are used for phase analysis. Morphological analysis showed the presence of porous oxide surfaces with octahedral crystals, scallops and "chimney" like vents. FTIR revealed the predominance of maghemite at the most of the pipe sections. Results of thickness measurements indicate severe thickness loss at the bend areas (extrados) of the pipes.

Page generated in 0.0762 seconds