1 |
Submission to shelterPage, Patrick J. January 1999 (has links)
The goal of this project was to create a mobile structure in which a suite of paintings could be transported and viewed. When the structure and paintings are arranged as an "installation," they will create a more active role for a "viewer" who could then be defined as a "participant." The participant would be involved in the assembly of the environment and would find more opportunities for interaction in the assembled environment than he or she would in a traditional gallery or museum setting. A description and explanation of the processes involved in the creation of this project is preceded by a discussion of different historical, cultural, and methodological ways by which artwork is or has been presented. Also referenced are different artists and philosophies that informed this project. / Department of Art
|
2 |
[en] METROLOGICAL CONTROL OF LIGHTING IN STANDARDS BOOTHS FOR VISUAL APPRAISAL / [pt] CONTROLE METROLÓGICO DA ILUMINAÇÃO EM CABINES PADRONIZADAS DE AVALIAÇÃO VISUALMIGUEL DE FREITAS CHRISTINO 19 October 2004 (has links)
[pt] Não obstante os sofisticados avanços em tecnologias
ópticas, ainda não existem fontes de luz artificial
capazes de simular de forma adequada a luz do dia
natural. Alcançar um padrão de iluminação como este
representará uma redução nos custos de produção, em
função de retrabalhos gerados por avaliações visuais
pouco confiáveis, e nas divergências comerciais
relacionadas a produtos que têm como característica de
controle a cor, tais como artigos têxteis, gráficos, de
merchandising etc. A presente pesquisa de mestrado em
metrologia relaciona-se à avaliação metrológica das fontes
luminosas e cabines de iluminação disponíveis no mercado
e à sua adequação às normas que definem especificações
técnicas, com o propósito de estimular introdução de
inovação tecnológica em novos desenvolvimentos industriais
capazes de melhorar o desempenho desses aparatos. A
pesquisa contribui, também, com o desenvolvimento de um
diagnóstico do acervo de normas técnicas disponíveis
aplicáveis à padronização de sistemas de iluminação;
investigação de lâmpadas fluorescentes usualmente
utilizadas como simuladores de luz do dia e avaliação
metrológica de cabines de iluminação disponíveis no
mercado. Em particular, medições foram realizadas em um
sistema espectroradiométrico de alta definição, que
utiliza um monocromador duplo com capacidade de dispersão
do feixe de 2 nm/mm. Ensaios e análises de repetitividade
e reprodutibilidade conduzidas no sistema de medição
espectroradiométrico permitiu quantificar a variabilidade
associada a cada lote de fabricação dos simuladores de
luz do dia, comercializados na forma de lâmpadas
fluorescentes disponíveis no mercado nacional.
Caracterizada a variação da distribuição espectral ao
longo do eixo das fontes luminosas investigadas
(lâmpadas) foi possível desenvolver uma análise do impacto
induzido na uniformidade da iluminação obtida em cabines
industrializadas, assim definindo um fator de
diferenciação de interesse técnico e comercial. A
pesquisa revelou que nenhum dos simuladores de luz do dia
testados atingiu os requisitos mínimos estabelecidos para
a comparação visual de cores, quando avaliados com base
em normas e práticas internacionais. Foram ainda
realizadas medições para se verificar a influência dos
elementos construtivos das cabines na distribuição
espectral de potência na área de avaliação. Fundamentado
nas 1578 medições realizadas em condições laboratoriais
que simulam ambientes industriais, a pesquisa comprova
que alterações nas características construtivas das
cabines possuem impacto no resultado da classificação das
distribuições espectrais de potência, criando assim uma
condição facilitadora para que as especificações
normativas sejam atingidas, mesmo com a utilização de
lâmpadas fluorescentes disponíveis no mercado e de preço
reduzido. / [en] Notwithstanding the complex advances in optical
technologies, there are still no artificial light sources
capable of adequately simulating the natural daylight.
Reaching such a lighting standard will represent a
reduction of the production costs, in view of the rework
caused by not so reliable visual evaluations, and of the
commercial conflicts related to products that have colour
as one of their control characteristics, such as textile,
graphics and merchandising articles. The present Master
degree metrology research is related to the metrological
evaluation of the lighting sources and light booths
available in the market (commercially available), and to
their conformity to the technical specifications standards,
aiming to stimulate the introduction of technological
innovation to new industrial developments eligible to
enhance the performance of these apparatus. The research
has also contributed to the development of a diagnosis of
the collection of the existing technical standards applied
to the standardisation of lighting systems; to the
investigation of fluorescent lamps generally used as
daylight simulators, and to the metrological evaluation of
light booths available in the market (commercially
available). Particularly, analyses were done with a highly
precise spectroradiometric system that uses a double
monochromator with capacity for beam dispersion of 2 nm/mm.
Tests and analyses on repeatability and reproducibility
made with the spectroradiometric measurement system let to
quantify the variety associated with each manufactured set
of daylight simulators, commercialised as fluorescent lamps
available at the local market. Having the spectral
distribution determined throughout the axis of the studied
lighting sources (lamps) it was possible to develop an
analysis of the impact caused at the lighting uniformity
obtained for industrial light booths, and so, specifying a
distinctive factor technically and commercially
interesting. The research revealed that, when evaluated
considering the international practices and standards, none
of the daylight simulators tested achieved the minimum
requirement indicated for the visual comparison of colours.
In addition, measurements were done to verify the influence
of the light booths building pieces at the power spectral
distribution within the evaluation area. Based on 1578
measurements done at laboratorial conditions simulating
industrial environment, the research proves that changes
in the building characteristics of the light booths produce
an impact at the result of the power spectral distribution
classification, creating, thus, a smooth condition for the
attendance of the standards specifications, even when using
low-cost fluorescents lamps available in the market.
|
3 |
[en] METROLOGICAL CONFIDENCE AND VALIDATION OF SPECTRORADIOMETRIC PROCEDURES FOR THE MEASUREMENT OF LIGHT SOURCES / [pt] CONFIABILIDADE METROLÓGICA E VALIDAÇÃO DE PROCEDIMENTOS ESPECTRORADIOMÉTRICOS PARA MEDIÇÃO DE FONTES LUMINOSASDANIELLE FERREIRA DE OLIVEIRA 22 November 2006 (has links)
[pt] A avaliação e a caracterização da cor constituem fatores
críticos do
processo de controle de qualidade de produtos, que também
devem atender
exigências dos clientes e consumidores finais. A cor de um
objeto depende
fortemente das características da iluminação. Nesse
contexto, a presente
pesquisa analisou e comparou os diferentes métodos
especificados em normas
internacionais, que qualificam o desempenho dos
simuladores de luz do dia
utilizados em avaliações visuais (cabines de luz) e
instrumentais
(espectrofotômetros). Para alcançar tais objetivos, foram
verificadas as
condições de medição estabelecidas pela CIE (intervalo de
medição e largura de
banda espectral) e elaborados e validados procedimentos de
medição de
diferentes fontes luminosas. Com base nestes
procedimentos, foram realizadas
medições de simuladores de luz do dia para adquirir as
suas distribuições
espectrais de potência, as quais foram utilizadas para
avaliá-los e para comparar
os métodos especificados em normas. Como principais
resultados da pesquisa
destacam-se: (i) a constatação de que, de fato, as
recomendações da CIE para
medição de fontes luminosas devem ser incorporadas ao
processo de medição;
(ii) o aumento da confiabilidade metrológica através da
validação dos
procedimentos espectroradiométricos com base em análises
de repetitividade
das medições; e (iii) a comparação realizada entre os
diferentes métodos de
avaliação de simuladores de luz do dia, o que permitiu
documentar para os
casos estudados a presença ou a falta de correlação entre
os mesmos. O
trabalho contribuiu também ao introduzir uma sistemática
normalizada de rotinas
para se expressar a incerteza associada à medição
espectroradiométrica. / [en] The evaluation and the characterization of the colour
constitute critical
factors of the process of quality control of products,
that also must take care of
requirements imposed by customers and final consumers. The
colour of an object
depends greatly on the characteristics of the
illumination. In this context, this
research is aimed at discussing the different
international standards that
characterize the performance of the daylight simulators
used in instrumental
(spectrophotometers) and visual (light booths) evaluations
and also at analysing
the differences between the various methods specified in
these standards. To
reach these objectives the measurement conditions
established by the CIE
(interval and spectral band-width) were verified and
elaborated and validated
procedures for the measurement of different luminous
sources. Based on these
procedures, measurements of daylight simulators were
carried out to acquire
their spectral power distributions. The measurement
results were then used to
analyze the evaluations methods specified in standards.
The following main
results have been accomplished: (i) the CIE
recommendations for the
measurement of luminous sources must, in fact, be
incorporated into the
measurement process; (ii) the increase in the metrological
reliability through the
validation of the spectroradiometric procedures based on
the analyses of the
repeatability of the measurements; and (iii) the
comparison established among
the different evaluation methods of daylight simulators,
leading to the distinction
between the presence or the lack of correlation present in
the different methods
investigated. The work also contributed by the
introduction of standard routines to
express the uncertainty associated with spectroradiometric
measurements.
|
Page generated in 0.0263 seconds