• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Pharmaceutical Quality and Syringeabilityof Pre-filled Syringes : An explorative study on the effect of different syringe barrel andplunger combinations on a proteinaceous pharmaceutical.

Sevegran, Emma January 2020 (has links)
4AbstractA pre-filled syringe consists of a number of different components and materials e.g. glass, polymer and silicone oil, which will, in various degrees, interact with the pharmaceutical protein and excipients contained within. In addition to soluble protein loss due to adsorption to silicone droplets, silicone oil (SO) have also been reported to form complexes with pharmaceutical proteins that potentially provoke early and late-stage immune responses. The objective of this project was to investigate the impact of 10 different syringe barrel and plunger combination on the quality on pharmaceutical X and the performance of the syringe (syringeability). This is an explorative study and the purpose of this study was to investigate what options there were rather than to make firm recommendations. pH measurements indicated all chosen combinations were within acceptance criteria. Similarly, subvisible particle with reference standards and USP <788> tests indicated that all chosen combinations were within acceptance criteria. Analysis of visible particles without reference standards indicated that all combinations except 1B and 1C were within acceptance criteria. In terms of syringeability, functional testing revealed that combination 8A was a very poor choice and combination 1B a very good choice. In all of the tests, the currently used combination 1A was within the acceptance criteria. With respect to both the pharmaceutical quality and syringeability, it was considered to be equally preferred as many other combinations. Therefore, there is no real urgency to exchange the currently used syringe. Further investigation of plunger B, and possible other plunger combinations is recommended as they might play a bigger role than the syringe barrel with regard to the syringeability. Additionally, placebo suspension can only be used as a representative alternative for testing pH. / En förfylld spruta består av många olika komponenter och material så som glas, polymer, silikon olja, vilka, till olika grad, kommer reagera med proteiner och hjälpämnen i läkemedlet. Utöver förlust av protein (som följd av adsorption till silikon droppar), har det även rapporterats att silikon olja (SO) bildar komplex med proteinerna i läkemedlet vilka kan framkalla en immunologisk reaktion. Syftet med detta projekt var att undersöka effekten av 10 olika kombinationer av sprut-höljen samt kolvar på kvalitén på läkemedel X samt sprutans prestationsförmåga. Detta är en explorativ studie och syftet var att undersöka vilka alternativ som finns samt få en indikation för hur de uppför sig snarare än att ge tydliga rekommendationer. pH mätningar indikerade att alla valda kombinationer var inom acceptanskriterier. Liknande, både mätning av synliga och mikroskopiska partiklar med hjälp av referenslösningar samt metod USP 788 indikerade att alla valda kombinationer var inom acceptanskriterier. Mätning av synliga och mikroskopiska partiklar utan referenslösningar indikerade att alla kombinationer utom 1B och 1C var inom acceptanskriterier. Gällande sprutkombinationernas funktionalitet (prestationsförmåga) visade det sig att kombination 8A var ett dåligt val och kombination 1B ett attraktivt val. I alla tester, den nuvarande använda kombinationen (1A) var inom acceptanskriterier. Med avseende på både läkemedlets kvalité samt funktionalitet visade sig 1A vara ett likvärdigt alternativ till de andra kombinationerna. Detta innebär att det i dagsläget inte finns ett akut behov av att byta ut det nuvarande sprutkombinationen. Fortsatt utredning av kolv B, samt andra kolvar, är att rekommendera då de kan ha större påverkan funktionaliteten än höljet. Vidare kan placebolösning enbart användas som ett representativt alternativ för att testa pH.

Page generated in 0.0327 seconds