  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Brises thermiques et risque de pollution dans la région de Beyrouth

Sakr, Samar 17 December 2012 (has links)
Située sur la rive Est de la mer méditerranéenne, la région de Beyrouth est soumise aux brises de mer et de terre en période estivale. En présence de ces circulations, la pollution atmosphérique devient complexe en raison des interrelations entre les phénomènes se produisant à plusieurs niveaux scalaires. Notre étude s'est appuyée sur des documents et données existant (dans le service de météorologie de l'aéroport de Beyrouth) et de notre propre base de données issues de nos propre campagnes de mesures. Les bases théoriques de ces types de circulation et la diversité géographique de notre milieu d'étude étaient l'objet de la première partie. La deuxième partie présente la démarche adoptée pour prendre en compte la relation entre l'atmosphère, les brises, la pollution et le milieu. Une troisième partie analyse les conditions favorables à l'apparition des brises aux échelles synoptique et régionale. Et une quatrième partie traite les variabilités spatio-temporelles des brises en relation avec la topographie et l'occupation du sol et leurs incidences sur le transport etles concentrations des polluants aux échelles fines. / Situated on the East the Mediterranean Sea, the region of Beirut is subjected to the sea and land breezes in summer. In the presence of these circulations, the atmospheric pollution becomes complex because of the interrelations between the phenomena occurring at several scalar levels. We used existing documents in our study and existing data (in the service department of meteorology of the airport of Beirut) and of our own base of data acquired during previous campaigns of measures.The theoretical bases of these types of circulation and the geographical diversity of our environment were the object of the first part. The second part presents the approach adopted to account the relation between the atmosphere, the breezes, the pollution and the environment. The third part analyzes the favorable conditions for the appearance of the breezes on synoptic and regional scales. And the fourth part treats the variability in space and in time of the breezes in relation of the topography and the land-use as well as their incidences on the pollutants concentrations and transportation on micro local scale.
2

Une approche numérique pour la conception d'ouvrages de protection côtière au tombolo oriental de la presqu'île de Giens / A numerical Approach for the design of coastal protection works in the oriental Tombolo of the Giens Peninsula

Vu, Minh Tuan 28 February 2018 (has links)
Le double tombolo de Giens, situé dans la ville de Hyères, dans le sud-est de la France, est une formation géomorphologique unique et rare dans le monde, qui relie l'île de Giens au continent. Il a été principalement formé en raison de la diffraction d'onde et de la réfraction par les îles. Il se compose de deux parties : la branche ouest (plage de l'Almanarre) directement en face du golfe de Giens et la branche orientale située sur la côte ouest de la baie d'Hyères. Ces parties sont séparées par l'étang salé des Pesquiers. La partie orientale du tombolo de Giens s'étend sur plus de dix kilomètres de l'embouchure de la rivière Gapeau au nord jusqu'à la plage de La Badine au sud. Les plages le long du tombolo oriental, en particulier les plages de Ceinturon et de Bona, sont sujettes à l'érosion et au rétrécissement en raison de causes naturelles et d'interférences humaines, mais les interventions anthropiques dominent.Afin d'atténuer ou d'empêcher l'érosion côtière, diverses structures côtières ont été utilisées le long du tombolo oriental de Giens. Elles ne peuvent résoudre l'érosion locale que dans certains cas, mais peuvent aussi engendrer des effets indésirables. Les structures côtières qui interfèrent avec le transport des sédiments le long des côtes, non seulement entraînent un déficit de sédiments et l'érosion dans la dérive en aval, mais aussi effacent le paysage environnant des plages.Les principaux objectifs de cette thèse étaient de mieux comprendre les processus physiques sous-jacents à la morpho-dynamique et d'anticiper l'évolution future du tombolo oriental de Giens en réponse aux différentes actions et interventions le long de la côte. La mesure structurelle la plus appropriée a été proposée non seulement pour protéger les plages de Ceinturon et Bona et pour stabiliser le rivage à long terme, mais aussi pour maintenir l'accessibilité ou l'esthétique des plages. Les modèles numériques MIKE 21 et LITPACK de DHI sont utilisés pour atteindre ces objectifs. L'évolution historique et future à long terme du rivage est également évaluée et prédite en utilisant la combinaison de techniques de télédétection, de système d'information géographique (SIG) et de régression linéaire. Ces modèles numériques ont été testés de manière satisfaisante sur des données historiques disponibles, car ils pouvaient reproduire l'hydrodynamique observée et l'évolution côtière.En particulier, une nouvelle approche suggérée pour simuler la présence de posidonies et divers types de fonds marins est présentée dans ce travail. Les résultats numériques interprètent le rôle ainsi que l'impact du changement de vent, la variation saisonnière, les événements extrêmes, les herbiers de posidonies, l'élévation du niveau de la mer et le ré-ensablement de la plage sur l'évolution morphologique du tombolo oriental de Giens. De plus, les résultats obtenus démontrent que les digues sous-marines jouent un rôle très important dans la protection des plages de Ceinturon et Bona, elles permettent de réduire efficacement la hauteur des vagues, la vitesse du courant et le transport des sédiments ainsi que contrecarrer le retrait du rivage dans toutes les conditions des vagues, à l'exception des tempêtes semi-centenaires et centennales pour lesquelles une certaine érosion persiste. Combinées à des ré-ensablements périodiques mais limités en espace et en temps, elles semblent constituer le meilleur compromis de protection à moyen et long terme. / The double tombolo of Giens, located in the town of Hyères, South East of France, is a unique and rare geomorphological formation in the world, which links Giens Island to the continent. It was mainly formed due to the wave diffraction and refraction by the islands. It consists of two parts: the western branch (Almanarre beach) directly facing the Gulf of Giens and the eastern branch lying on the western coast of Hyères bay. These parts are distinctly separated by the salt pond of Pesquiers. The eastern part of Giens tombolo extends over more than ten kilometers from the mouth of Gapeau river in the north to La Badine beach in the south. The beaches along the eastern tombolo, especially Ceinturon and Bona beaches are subject to beach erosion and beach narrowing due to both natural causes and human interference, but anthropogenic interventions are still dominant. In order to mitigate or prevent coastal erosion, various coastal structures have been used along the eastern Giens tombolo. They can only solve local erosion in some cases, but may also trigger some undesirable effects as well as disadvantages. Even the shore-normal structures that interfere with longshore sediment transport, not only result in the deficit of sediment and erosion in the downstream drift, but also blot out surrounding landscape of the beaches.The main objectives of this study was to better understand the physical processes underlying the morphodynamics, and also anticipate future evolution of the eastern Giens tombolo in response to different actions and interventions taking place along the coast. Thereof, the submerged breakwater (SBW) was proposed to not only protect the Ceinturon and Bona beaches and stabilize the shoreline in the long term, but also maintain beach amenity or aesthetics. DHI’s MIKE 21 and LITPACK numerical models are used in order to achieve these above-mentioned objectives. Additionally, the historical and future medium-term shoreline evolution along the eastern Giens tombolo is also evaluated and predicted by using the combination of remote sensing, geographic information system (GIS) techniques coupled with the Digital Shoreline Analysis System (DSAS) along with linear regression method. These numerical models were satisfactorily tested available historical data, as they could reproduce the observed hydrodynamics and coastal evolution. Especially, a novel approach suggested to simulate the presence of Posidonia seagrass and various types of seabed is presented in this work. The numerical results interpret the role as well as impact of wind change, seasonal variation, extreme events, Posidonia seagrass, sea level rise, and beach nourishment on the morphological evolution of the eastern Giens tombolo. Moreover, the results obtained strongly demonstrate that the SBWs play a very important in protecting Ceinturon and Bona beaches to a certain degree, viz. effectively reducing the nearshore wave heights, current speed and sediment transport as well as counteracting the retreat of the shoreline under the wave conditions apart from the semi-centennial and centennial storms.
3

Eficiência e forma do brise-soleil na arquitetura de Campo Grande-MS

Maragno, Gogliardo Vieira January 2000 (has links)
O objetivo deste trabalho é estudar a utilização de brise-soleil na arquitetura, analisando as relações entre sua eficiência ambiental e participação no resultado plástico e formal dos edifícios, a partir da análise de exemplares da arquitetura de Campo Grande – MS. O trabalho examina os aspectos relevantes da aplicação do brise-soleil para obtenção do conforto térmico e racionalização do uso de energia nas edificações de clima quente e como resposta à intensiva utilização de superfícies envidraçadas nas edificações. Aborda os fatores que levaram ao desenvolvimento dos brises por Le Corbusier, sua incorporação e difusão no repertório da arquitetura moderna brasileira, especialmente em Campo Grande – MS. Analisa também o período posterior de predomínio dos fechamentos envidraçados com condicionamento térmico artificial e o período recente de nova consciência ambiental com revalorização dos sistemas passivos de condicionamento. A pesquisa parte da hipótese de que os brise-soleils, quando utilizados criteriosamente, além de contribuírem de maneira acentuada na proteção contra os ganhos térmicos advindos da radiação solar, constituem importante elemento arquitetônico para a definição formal, acentuando ou, muitas vezes, constituindo o próprio caráter arquitetônico dos edifícios. Procura demonstrar esta hipótese analisando trinta exemplares significativos da arquitetura de Campo Grande – MS.
4

Eficiência e forma do brise-soleil na arquitetura de Campo Grande-MS

Maragno, Gogliardo Vieira January 2000 (has links)
O objetivo deste trabalho é estudar a utilização de brise-soleil na arquitetura, analisando as relações entre sua eficiência ambiental e participação no resultado plástico e formal dos edifícios, a partir da análise de exemplares da arquitetura de Campo Grande – MS. O trabalho examina os aspectos relevantes da aplicação do brise-soleil para obtenção do conforto térmico e racionalização do uso de energia nas edificações de clima quente e como resposta à intensiva utilização de superfícies envidraçadas nas edificações. Aborda os fatores que levaram ao desenvolvimento dos brises por Le Corbusier, sua incorporação e difusão no repertório da arquitetura moderna brasileira, especialmente em Campo Grande – MS. Analisa também o período posterior de predomínio dos fechamentos envidraçados com condicionamento térmico artificial e o período recente de nova consciência ambiental com revalorização dos sistemas passivos de condicionamento. A pesquisa parte da hipótese de que os brise-soleils, quando utilizados criteriosamente, além de contribuírem de maneira acentuada na proteção contra os ganhos térmicos advindos da radiação solar, constituem importante elemento arquitetônico para a definição formal, acentuando ou, muitas vezes, constituindo o próprio caráter arquitetônico dos edifícios. Procura demonstrar esta hipótese analisando trinta exemplares significativos da arquitetura de Campo Grande – MS.
5

Eficiência e forma do brise-soleil na arquitetura de Campo Grande-MS

Maragno, Gogliardo Vieira January 2000 (has links)
O objetivo deste trabalho é estudar a utilização de brise-soleil na arquitetura, analisando as relações entre sua eficiência ambiental e participação no resultado plástico e formal dos edifícios, a partir da análise de exemplares da arquitetura de Campo Grande – MS. O trabalho examina os aspectos relevantes da aplicação do brise-soleil para obtenção do conforto térmico e racionalização do uso de energia nas edificações de clima quente e como resposta à intensiva utilização de superfícies envidraçadas nas edificações. Aborda os fatores que levaram ao desenvolvimento dos brises por Le Corbusier, sua incorporação e difusão no repertório da arquitetura moderna brasileira, especialmente em Campo Grande – MS. Analisa também o período posterior de predomínio dos fechamentos envidraçados com condicionamento térmico artificial e o período recente de nova consciência ambiental com revalorização dos sistemas passivos de condicionamento. A pesquisa parte da hipótese de que os brise-soleils, quando utilizados criteriosamente, além de contribuírem de maneira acentuada na proteção contra os ganhos térmicos advindos da radiação solar, constituem importante elemento arquitetônico para a definição formal, acentuando ou, muitas vezes, constituindo o próprio caráter arquitetônico dos edifícios. Procura demonstrar esta hipótese analisando trinta exemplares significativos da arquitetura de Campo Grande – MS.
6

Avaliação de sistemas de janela para suporte a decisões de projeto quanto à iluminação e uso de energia / Window systems evaluation for design decision support on daylight and energy use.

Lima, Kamila Mendonça de 16 February 2016 (has links)
Projetar sistemas de janela considerando a adequação climática envolve lidar com os efeitos do meio externo, que são dinâmicos, e com estratégias que podem ser conflitantes, tais como o controle do ganho de calor solar e aproveitamento da iluminação natural, ambos elementos provenientes da radiação do Sol. Parte-se do princípio de que isso é feito considerando o impacto de diferentes variáveis de projeto em diferentes indicadores de desempenho simultaneamente, para suporte a decisão. O estudo do efeito dessas variáveis de projeto da janela quando combinadas ainda não é consolidado, especialmente no caso de localidades de baixa latitude. O objetivo geral desta pesquisa de doutorado é avaliar sistemas de janela estáticos e dinâmicos para suporte a decisões de projeto arquitetônico, quanto a diferentes critérios de desempenho relacionados à iluminação natural e uso de energia, de forma integrada. São estudados sistemas de janela compostos por uma abertura envidraçada e proteções solares de aletas horizontais externas, fixas e móveis. O recorte engloba edificações com uso de escritório no contexto do clima quente e úmido da cidade de Maceió-AL. Para isso, simulações computacionais integradas utilizando os softwares Daysim e EnergyPlus foram realizadas, considerando o acionamento das lâmpadas apenas quando a luz natural não fosse suficiente para atender ao uso do ambiente. As variáveis de projeto analisadas foram: percentual de área de abertura, tipo de vidro, ângulo de sombreamento, quantidade de aletas, tipo de acionamento do sistema de proteção solar e orientação da abertura. As soluções arquitetônicas resultantes das combinações de todas as variáveis entre si foram avaliadas com relação à disponibilidade e distribuição da luz natural e demanda de energia elétrica para condicionamento do ar e iluminação artificial no ambiente interno, e classificadas segundo dois indicadores principais. Foram identificadas as variáveis de projeto dentre as analisadas com maior potencial de impacto no desempenho obtido em diferentes situações. Os resultados mostraram que é possível uma alternativa se encontrar em uma faixa de 10% melhores cenários nos dois indicadores ao mesmo tempo. Observou-se ainda que, apesar de a demanda de energia para condicionamento do ar ser frequentemente maior do que a demanda para iluminação, o desempenho da abertura quanto à iluminação pode ter um peso decisivo na escolha de projeto, pois este indicador de desempenho é mais sensível às variáveis da janela estudadas do que o primeiro. Por fim, observou-se que os protetores solares dinâmicos não são garantia de melhoria de desempenho em relação a sistemas estáticos. / Designing window systems in a climate responsive way involves dealing with the effects of the external environment, which are dynamic, and strategies that may conflict, such as daylight and control of solar heat gains, both elements related to the sun. This research assumes that this is done considering the impact of different design variables in different performance indicators simultaneously, for decision support. The study of the effect of window design variables when combined is not yet consolidated, especially in case of low latitude locations. The general objective of this doctoral research is to evaluate static and dynamic window systems to support architectural design decisions regarding different performance criteria related to daylight and energy use, in an integrated manner. The studied window system consists of a glazed opening and external horizontal slat-type shading devices, fixed and mobile, in offices in the hot and humid climate of the city of Maceió-AL. For this, computer integrated simulations using Daysim and EnergyPlus software were carried out, considering the activation of the lighting system only when daylight is not sufficient to meet the usage requirements. The design variables analyzed were window-to-wall ratio, glazing type, cut-off angle, number of slats, type of shading control and orientation. Architectural solutions resulting from combinations of all variables were evaluated regarding the availability and distribution of daylight and electricity demand for air conditioning and artificial lighting in the indoor environment. The solutions were then rated and ranked according to two main indicators. The design variables among the analyzed with potential of high impact in the obtained performance in different situations were identified. The results showed that it is possible an alternative be in a range of 10% best scenarios in the two criteria at the same time. It was also observed that, although the energy demand for conditioning air often be greater than the lighting energy demand, the performance of the window on daylight can have a decisive weight on the design choice, because this performance indicator is more sensitive to the window variables than the first. Finally, it was observed that the dynamic shading systems are not performance-enhancing guarantee compared to static systems.
7

Avaliação do desempenho térmico de brises transparentes: ensaio em células-teste / Evaluation thermal performance of transparent solar protections: measurements in test-cells

Miana, Anna Christina 09 December 2005 (has links)
O objetivo desta pesquisa foi avaliar o desempenho térmico de brises transparentes, por meio de medidas em células-teste construídas em escala 1:1, na cidade de Campinas, São Paulo. Trata-se de um estudo que faz avaliação comparativa das temperaturas internas e superficiais dos brises e do vidro da janela em seis células-teste, quatro delas protegidas com brises transparentes horizontais e verticais combinados, constituídos por vidros, outra protegida com brise-soleil metálico horizontal e uma sem dispositivo de proteção solar, sendo esta considerada de referência. Foram selecionados quatro tipos de vidro com diferentes características ópticas: vidro float comum incolor, vidro impresso mini-boreal, vidro float comum azul e vidro refletivo metalizado a vácuo prata médio. Foi possível concluir que os brises de vidro refletivo prata, float azul e impresso possuem um desempenho térmico similar entre si e ao brise metálico estudado, e que o brise de vidro float incolor não apresenta um resultado de desempenho térmico satisfatório. Com relação aos procedimentos de medidas de campo, foram verificadas as modificações necessárias, para trabalhos futuros que tenham o mesmo objetivo dessa pesquisa, ou similares a esse. Além da avaliação do desempenho térmico, foi também iniciada uma avaliação do desempenho luminoso dos brises. Por meio das medidas dos níveis de iluminação natural dentro das células-teste constatou-se que o brise de vidro impresso apresentou um ótimo desempenho luminoso e que o brise de vidro refletivo prata reduziu significativamente a iluminância dentro da célula-teste, obtendo um desempenho luminoso inferior até mesmo ao brise metálico / This research intended to evaluate thermal performance of transparent solar protections using measurements in full scale test cells, located in the city of Campinas, São Paulo, Brazil. Surface (window and shading device) and internal air temperatures were compared for six test cells. One of them was unprotected, for reference purposes, another was obstructed with a metallic shading device and the other four had transparent glass horizontal and vertical shades installed. Four different types of glass with different optical properties were selected: float clear glass, mini-boreal printed glass, float blue glass and metallic silver reflective glass. The results of the thermal appraisal showed that silver reflective glass, float blue and printed glass shadings achieved similar performance, not very different to the ones obtained for the metallic shading device. Therefore the float clear glass shading did not attain a satisfactory result. The field measurements procedures were also evaluated and test cells characteristics problems were identified, in order to suggest changes for future research in this area. This research began to evaluate light performance of the same solar protections. For light performance evaluation were measured the daylight in the center of each test cell and outside. It was concluded that printed glass shadings presented very good results and silver reflective glass reduced the daylight inside the test cell
8

Desempenho térmico e luminoso de brises externos em escritórios em Maceió AL / Thermal and luminous performance of shading devices in offices in Maceió AL

Lima, Kamila Mendonça de 24 February 2012 (has links)
Solar control has been used as a bioclimatic strategy in buildings located in hot climates. It is used to block direct solar radiation and to reduce the admission of light and heat through windows. Such effects occur simultaneously, so that a given device configuration that meet the criterion of thermal performance may reduce natural light and vice versa, depending on the shading device configuration. This conflict can cause visual and thermal discomfort that can lead to the need of artificial lighting and air conditioning systems. The goal of this dissertation is comparatively evaluate the luminous and thermal performance of different external shading devices configuration in office buildings located in the city of Maceió-AL. The methodology is based on several parametric analysis, regarding to illuminance, light uniformity and solar heat gains. Computer simulation has been carried out using Troplux 5 and DesignBuilder 3 softwares. A typical office room model was used, where louver parameters has been examined (slat spacing, slope and reflectance), considering windows oriented to North, South, East and West. The annual performance variation has also been studied, such as and the unshaded condition. The effect of each configuration has been analyzed concerning lighting and thermal performance as well its integrated performance. Shading devices produced an average reduction of 34% varying to 92% in comparison to the unshaded condition, for the illuminance, and 29% varying to 51% for the solar gains. Configurations with more favorable combined thermal and luminous results were identified for each orientation analyzed. Finally, it was observed that the choice between different configurations of shading devices, even with the same shadow-mask, changes the luminous and thermal performance. The information here produced can help to architect and design shading devices in practice. In addition, the work produced an important knowledge concerning integrated performance of openings of buildings in hot climates. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O sombreamento de aberturas é uma estratégia bioclimática adequada para edificações em regiões de clima quente e úmido. Seu uso diminui a admissão de luz e de calor no ambiente. Tais efeitos ocorrem simultaneamente, de forma que uma determinada configuração de dispositivos que atenda ao critério do desempenho térmico pode afetar negativamente a iluminação natural e vice-versa, a depender das características formais do brise utilizado. Esse conflito pode ocasionar desconforto (visual e/ou térmico) e dependência de sistemas artificiais de condicionamento e iluminação. Diante de tais aspectos, o objetivo desta dissertação de mestrado é avaliar comparativamente o desempenho luminoso e térmico de diferentes configurações de brises externos, em edificações de escritório, na cidade de Maceió-AL. A metodologia utilizada consistiu de análises paramétricas, com base em dados referentes à iluminância interna, uniformidade da luz e ganhos térmicos solares, obtidos por simulação computacional nos softwares TropLux 5 e DesignBuilder 3. Foi elaborado um modelo de ambiente representativo da tipologia de escritórios em Maceió, a partir do qual foram analisados os parâmetros referentes à configuração do brise (espaçamento, inclinação e refletância das aletas), considerando a janela orientada a Norte, Sul, Leste e Oeste e a variação anual dos índices registrados, bem como as situações de janela exposta. As comparações foram feitas em dois níveis: entre os diferentes parâmetros e entre os desempenhos (térmico e luminoso). As diferentes configurações de brise foram classificadas, sendo identificadas aquelas mais favoráveis em relação ao desempenho térmico, luminoso e ao desempenho conjunto, para cada uma das fachadas analisadas. Os resultados obtidos permitiram a descrição do efeito do espaçamento, inclinação e refletância para cada fachada. Também foram quantificados os percentuais de redução dos índices analisados, em relação aos modelos com janela exposta. Obteve-se redução média de 34% a 92% para a iluminância, e de 29% a 51% para os ganhos solares. Quanto aos resultados conjuntos: na orientação Norte, todas as configurações de brise analisadas apresentaram desempenho conjunto equilibrado. Com a janela orientada a Sul, apresentaram-se restrições para as configurações que combinem cor clara e pouca inclinação, que resultariam em excessos de luz e calor. Já nas orientações Leste e Oeste, os brises de desempenho conjunto mais favorável foram aqueles com aletas de cor clara e pouco inclinadas ou aletas de cor de refletância média e maior inclinação em relação à horizontal. A alteração do espaçamento não apresentou influência significativa na variação da quantidade de luz e calor, mas alterou a uniformidade da iluminação. Por fim, observou-se que a escolha entre diferentes configurações de brise, mesmo com máscaras de sombra iguais, modifica o desempenho térmico e luminoso resultante. Esse conhecimento pode auxiliar o projeto arquitetônico. Além disso, o trabalho apresentado caracteriza um passo no conhecimento acerca do desempenho integrado de sistemas de abertura em localidades de clima quente e úmido.
9

Avaliação do desempenho térmico de brises transparentes: ensaio em células-teste / Evaluation thermal performance of transparent solar protections: measurements in test-cells

Anna Christina Miana 09 December 2005 (has links)
O objetivo desta pesquisa foi avaliar o desempenho térmico de brises transparentes, por meio de medidas em células-teste construídas em escala 1:1, na cidade de Campinas, São Paulo. Trata-se de um estudo que faz avaliação comparativa das temperaturas internas e superficiais dos brises e do vidro da janela em seis células-teste, quatro delas protegidas com brises transparentes horizontais e verticais combinados, constituídos por vidros, outra protegida com brise-soleil metálico horizontal e uma sem dispositivo de proteção solar, sendo esta considerada de referência. Foram selecionados quatro tipos de vidro com diferentes características ópticas: vidro float comum incolor, vidro impresso mini-boreal, vidro float comum azul e vidro refletivo metalizado a vácuo prata médio. Foi possível concluir que os brises de vidro refletivo prata, float azul e impresso possuem um desempenho térmico similar entre si e ao brise metálico estudado, e que o brise de vidro float incolor não apresenta um resultado de desempenho térmico satisfatório. Com relação aos procedimentos de medidas de campo, foram verificadas as modificações necessárias, para trabalhos futuros que tenham o mesmo objetivo dessa pesquisa, ou similares a esse. Além da avaliação do desempenho térmico, foi também iniciada uma avaliação do desempenho luminoso dos brises. Por meio das medidas dos níveis de iluminação natural dentro das células-teste constatou-se que o brise de vidro impresso apresentou um ótimo desempenho luminoso e que o brise de vidro refletivo prata reduziu significativamente a iluminância dentro da célula-teste, obtendo um desempenho luminoso inferior até mesmo ao brise metálico / This research intended to evaluate thermal performance of transparent solar protections using measurements in full scale test cells, located in the city of Campinas, São Paulo, Brazil. Surface (window and shading device) and internal air temperatures were compared for six test cells. One of them was unprotected, for reference purposes, another was obstructed with a metallic shading device and the other four had transparent glass horizontal and vertical shades installed. Four different types of glass with different optical properties were selected: float clear glass, mini-boreal printed glass, float blue glass and metallic silver reflective glass. The results of the thermal appraisal showed that silver reflective glass, float blue and printed glass shadings achieved similar performance, not very different to the ones obtained for the metallic shading device. Therefore the float clear glass shading did not attain a satisfactory result. The field measurements procedures were also evaluated and test cells characteristics problems were identified, in order to suggest changes for future research in this area. This research began to evaluate light performance of the same solar protections. For light performance evaluation were measured the daylight in the center of each test cell and outside. It was concluded that printed glass shadings presented very good results and silver reflective glass reduced the daylight inside the test cell
10

Avaliação de sistemas de janela para suporte a decisões de projeto quanto à iluminação e uso de energia / Window systems evaluation for design decision support on daylight and energy use.

Kamila Mendonça de Lima 16 February 2016 (has links)
Projetar sistemas de janela considerando a adequação climática envolve lidar com os efeitos do meio externo, que são dinâmicos, e com estratégias que podem ser conflitantes, tais como o controle do ganho de calor solar e aproveitamento da iluminação natural, ambos elementos provenientes da radiação do Sol. Parte-se do princípio de que isso é feito considerando o impacto de diferentes variáveis de projeto em diferentes indicadores de desempenho simultaneamente, para suporte a decisão. O estudo do efeito dessas variáveis de projeto da janela quando combinadas ainda não é consolidado, especialmente no caso de localidades de baixa latitude. O objetivo geral desta pesquisa de doutorado é avaliar sistemas de janela estáticos e dinâmicos para suporte a decisões de projeto arquitetônico, quanto a diferentes critérios de desempenho relacionados à iluminação natural e uso de energia, de forma integrada. São estudados sistemas de janela compostos por uma abertura envidraçada e proteções solares de aletas horizontais externas, fixas e móveis. O recorte engloba edificações com uso de escritório no contexto do clima quente e úmido da cidade de Maceió-AL. Para isso, simulações computacionais integradas utilizando os softwares Daysim e EnergyPlus foram realizadas, considerando o acionamento das lâmpadas apenas quando a luz natural não fosse suficiente para atender ao uso do ambiente. As variáveis de projeto analisadas foram: percentual de área de abertura, tipo de vidro, ângulo de sombreamento, quantidade de aletas, tipo de acionamento do sistema de proteção solar e orientação da abertura. As soluções arquitetônicas resultantes das combinações de todas as variáveis entre si foram avaliadas com relação à disponibilidade e distribuição da luz natural e demanda de energia elétrica para condicionamento do ar e iluminação artificial no ambiente interno, e classificadas segundo dois indicadores principais. Foram identificadas as variáveis de projeto dentre as analisadas com maior potencial de impacto no desempenho obtido em diferentes situações. Os resultados mostraram que é possível uma alternativa se encontrar em uma faixa de 10% melhores cenários nos dois indicadores ao mesmo tempo. Observou-se ainda que, apesar de a demanda de energia para condicionamento do ar ser frequentemente maior do que a demanda para iluminação, o desempenho da abertura quanto à iluminação pode ter um peso decisivo na escolha de projeto, pois este indicador de desempenho é mais sensível às variáveis da janela estudadas do que o primeiro. Por fim, observou-se que os protetores solares dinâmicos não são garantia de melhoria de desempenho em relação a sistemas estáticos. / Designing window systems in a climate responsive way involves dealing with the effects of the external environment, which are dynamic, and strategies that may conflict, such as daylight and control of solar heat gains, both elements related to the sun. This research assumes that this is done considering the impact of different design variables in different performance indicators simultaneously, for decision support. The study of the effect of window design variables when combined is not yet consolidated, especially in case of low latitude locations. The general objective of this doctoral research is to evaluate static and dynamic window systems to support architectural design decisions regarding different performance criteria related to daylight and energy use, in an integrated manner. The studied window system consists of a glazed opening and external horizontal slat-type shading devices, fixed and mobile, in offices in the hot and humid climate of the city of Maceió-AL. For this, computer integrated simulations using Daysim and EnergyPlus software were carried out, considering the activation of the lighting system only when daylight is not sufficient to meet the usage requirements. The design variables analyzed were window-to-wall ratio, glazing type, cut-off angle, number of slats, type of shading control and orientation. Architectural solutions resulting from combinations of all variables were evaluated regarding the availability and distribution of daylight and electricity demand for air conditioning and artificial lighting in the indoor environment. The solutions were then rated and ranked according to two main indicators. The design variables among the analyzed with potential of high impact in the obtained performance in different situations were identified. The results showed that it is possible an alternative be in a range of 10% best scenarios in the two criteria at the same time. It was also observed that, although the energy demand for conditioning air often be greater than the lighting energy demand, the performance of the window on daylight can have a decisive weight on the design choice, because this performance indicator is more sensitive to the window variables than the first. Finally, it was observed that the dynamic shading systems are not performance-enhancing guarantee compared to static systems.