• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Associations macromoléculaires en solution et aux interfaces : stimulation et ciblage par le pH et la température

Siband, Elodie 15 December 2009 (has links) (PDF)
Nous étudions les propriétés associatives de polymères stimulables en solution et aux interfaces. Les associations sont contrôlées par la température et le pH en utilisant des unités complémentaires. Les associations sont induites par une séparation de phase de type LCST. L'introduction de motifs ionisables dans ces chaînes de PNIPAM permet de rendre le polymère également sensible au pH. Deux séries de copolymères sont ainsi préparées : l'une comportant des motifs acides faibles dans la chaîne à LCST (unités d'Acide Acrylique (AA)), l'autre possédant des unités bases faibles ((N,N - methacrylamide de [(diméthyl amino) propyle] (MADAP). Alors que les polymères précurseurs PNIPAM-AA et PNIPAM-MADAP sous forme ionisée ne présentent pas individuellement de comportement thermo-associatif, leur mélange permet de générer une agrégation originale faisant intervenir une complexation électrostatique induite par chauffage. Le greffage de ces moteurs macromoléculaires sur un squelette hydrosoluble de poly(acrylamide) permet d'envisager la formation de gels réversibles en solution semi-diluée étudiée par DSC, rhéologie et diffusion de neutrons aux petits angles. Le choix des paramètres environnementaux (pH, température, force ionique) ainsi que l'addition de polymères précurseurs de charge opposée aux greffons permet de piloter l'association de manière très spécifique. De manière originale, les connaissances issues des propriétés associatives en solution sont appliquées aux interfaces pour rendre les surfaces adaptatives. Les interactions spécifiques entre des brosses de polymères et des solutions macromoléculaires sont caractérisées par ellipsométrie et par réflectivité de neutrons. Nous montrons que l'adsorption de polymères précurseurs et de copolymères en peigne sur des brosses d'homopolymère est contrôlée par les conditions environnementales (pH et température) et est complètement réversible.
2

Adhésion stimulable d'hydrogels

Sudre, Guillaume 18 January 2011 (has links) (PDF)
L'adhésion stimulable d'un hydrogel sur une surface a été étudiée de façon systématique par le jeu d'interactions spécifiques réversibles entre polymères. A cette fin, des surfaces modèles de brosses de poly(acide acrylique) (PAA) ont été obtenues par " grafting to " et leur structure, sensible au pH, a été caractérisée par réflectivité de neutrons. Parallèlement, des hydrogels neutres de poly(N,N-diméthylacrylamide) (PDMA) et de poly(acrylamide) (PAM) ont été synthétisés par polymérisation radicalaire conventionnelle ; leurs propriétés mécaniques, leur structure et leur gonflement ont été étudiés et variés au moyen de deux paramètres : le gonflement initial et le taux de réticulant. En solution aqueuse, les couples de polymères PAA et PDMA ou PAA et PAM forment des complexes inter polymères dont l'apparition dépend du pH et de la température. Les associations se produisent à pH faible dans les deux cas ; et quoique relativement similaire d'un point de vue chimique, ces couples de polymères s'associent par une séparation de phase de type UCST lorsque l'accepteur de proton est le PAM, mais par une transition de type LCST avec le PDMA. La formation de ces complexes en solution a aussi été étudiée aux interfaces entre la brosse de PAA et les hydrogels de PDMA et PAM. Une étude à l'échelle de la brosse a été menée par réflectivité de neutrons : en présence de gel, un gonflement additionnel de la brosse est observé en présence des interactions à faible pH alors que sa structure n'est pas perturbée à pH élevé. L'étude macroscopique de ces interactions aux interfaces correspond aux tests d'adhésion : un montage expérimental et des protocoles adaptés à la mesure quantitative de l'énergie d'adhésion entre matériaux immergés. Au moyen d'un contact plan-plan entre les brosses de PAA et les gels de PDMA et PAM attachés de façon covalente sur des substrats, une adhésion immergée stimulable par le pH de l'ordre de grandeur des adhésions thermodynamiques a été mise en évidence, de même que les cinétiques relativement lentes impliquées dans la formation et la rupture des complexes aux interfaces.
3

Déformation et agrégation sous écoulement de globules rouges et vésicules en microcanaux / Deformation and aggregation in flow of red blood cells and vesicles in microchannels

Lanotte, Luca 17 May 2013 (has links)
Les globules rouges (GR) jouent un rôle clé dans l’exercice de fonctions physiologiques du corps humain. Dans la microcirculation, par exemple, où ils s’écoulent dans des capillaires de diamètre comparable à leurs mêmes dimensions, les érythrocytes sont responsables de l’échange d’oxygène et nutriments avec les tissus. Il a été montré dans de nombreux articles scientifiques que des dysfonctionnements dans les propriétés des GRs et des dommages du tissu endothélial, en particulier au niveau de la couche de glycoprotéines qui le recouvre (glycocalyx), sont la cause principale des maladies vasculaires telles que la thrombose, le diabète et l’athérosclérose. En conséquence, la connaissance des propriétés mécaniques et rhéologiques qui permettent aux érythrocytes de se déformer et de s’organiser en agrégats dans les vaisseaux sanguins permettrait de mieux comprendre les mécanismes qui gouvernent la circulation du sang et, par conséquent, de faciliter le diagnostic des états pathologiques.Dans cette thèse l’attention s’est concentrée sur deux thèmes principaux : l’agrégation des GRs pendant l’écoulement dans les microcapillaires et la fonction du glycocalyx dans la microcirculation. Même si le sujet est à la fois essentiel et d’intérêt scientifique considérable, une analyse quantitative de la formation d’agrégats de GRs (cluster) n’avait pas encore été réalisée. Dans une première phase de ce projet de thèse des expériences in vitro ont été réalisées sur des suspensions de GRs avec un hématocrite d’environ 10%, afin d’observer leur tendance à s’agréger au cours du déplacement dans des tubes en verre de diamètre égal à 10 µm. Ce comportement a été évalué en fonction de la pression imposée et du temps de résidence dans de microcanaux, en mesurant la longueur des clusters et leur composition numérique. Le but principal a été comprendre le type d’interaction entre les cellules composantes un cluster : il s’agit d’une interaction purement hydrodynamique ou des autres forces sont également impliquées ? Les résultats expérimentaux présentés dans cette thèse clairement montrent que la véritable force motrice du phénomène est la pression imposée dans les capillaires. Cette approche microfluidique permet de jeter les bases pour le développement de dispositifs cliniques et diagnostiques.Dans la deuxième partie du projet, une campagne expérimentale a été réalisée sur microcapillaires en verre revêtus de brosses de polymères, afin de simuler les conditions in vivo dans la microcirculation. Il a été établi avec certitude que le lumen des vaisseaux sanguins est recouvert d’une couche de glyco-polymères (glycocalyx) liés à la membrane des cellules endothéliales qui tapissent leurs parois. La compréhension du rôle hydrodynamique du glycocalyx est essentielle pour expliquer le lien entre le dysfonctionnement cette couche et le maladies vasculaires et pour développer des tests basés sur la microfluidique, capable de représenter correctement les interactions entre les parois et le composants sanguins. Des couches nanométriques de poly-hydroxyéthylméthacrylate (pHEMA) ont été produites par ce qu’on appelle la technique grafting-from et, après une caractérisation approfondie, utilisées pour revêtir les surfaces internes de canaux en verre de 10 µm de diamètre. Dans cette thèse, nous présentons les profils de vitesse obtenus en étudiant la circulation dans des tubes recouverts avec brosses de différentes épaisseurs. On montre que il y a une augmentation de la résistance à l’écoulement dans les canaux recouverts et que la réduction de la vitesse est significativement plus grande par rapport à ce qui se produirait à la suite d’une simple réduction géométrique du lumen disponible. De plus, à partir de l’observation de l’écoulement de GRs à l’intérieur des microcapillaires recouverts par les brosses de polymère, il a été constaté que la vitesse et la déformabilité des GRs dépendent strictement de la présence de la bio-couche sur les parois des microtubes. / The investigation of red blood cells (RBCs) dynamics in blood circulation is one of the most innovative and intriguing challenge of science nowadays since erythrocytes are involved in fundamental physiological functions of human body. In particular, RBCs play a key role in microcirculation where narrow dimensions of vessels (comparable to cell size) promote a close contact between cells and capillary walls and, as a consequence, the exchange of oxygen between blood and tissues. It is well established in scientific literature that disorders in RBCs properties and damages of endothelium are the main causes of common vascular diseases, such as thrombosis, diabetes and atherosclerosis. Thus, the full understanding of mechanical and rheological properties of RBCs would allow not only to shed light on the mechanisms leading blood circulation, but also to develop increasingly reliable diagnostic devices. In this thesis, the attention is mainly focused on two topics: RBCs aggregation in microcapillaries and the role of glycocalyx in microcirculation. As regards the first theme, despite the considerable scientific importance, a quantitative analysis of RBCs aggregates formation (clustering) in microvessels is still lacking. In a first phase of the project, experimental investigations in vitro have been performed on RBCs suspensions with hematocrit almost equal to 10% to observe their tendency to aggregate during the flow in glass microtubes (diameter equal to 10 µm). RBCs aggregation has been evaluated as a function of the fixed pressure drop (Δp) and the residence time in microchannels by measuring clusters length and their statistical composition. The main aim of the experiments was to clarify the nature of the force acting on consecutive cells in a cluster: is it a pure hydrodynamic interaction or are other kinds of forces involved too? The experimental results presented in this thesis clearly show that the driving force of the phenomenon is the imposed Δp in the microtubes. The outcomes of these investigations suggest that microfluidics can represent an efficient means to develop clinical and diagnostic tests on healthy and pathological blood.In the second part of the thesis, an experimental campaign was performed on glass capillaries lined with polymer brushes to mimic in vivo conditions in microvascularity. Several scientific papers show that the lumen of vascular vessels is coated by a layer of glycopolymers linked to the endothelial cells. The full understanding of the hydrodynamic role of glycocalyx is essential to elucidate the link between its dysfunctions and vascular diseases. Moreover, it would be helpful to develop innovative clinical tests by microfluidics that could take in account the interactions between “hairy” walls and blood components. Nanometric brushes of poly-hydroxyethylmethacrylate (p-HEMA) have been produced by a grafting-from technique and, after characterization, they have been used to line internal surfaces of silica capillaries with 10 µm diameter. Here, we present the experimental results obtained by measuring velocity profiles in glass channels bearing polymer brushes of different thickness. An increasing flow resistance is observed in hairy channels as a function of brush thickness. The measured velocity decrease is significantly higher than expected from a simply geometrical reduction of the available capillary lumen. Furthermore, the observation of RBCs flow in such brush-coated channels reveals that cells velocity and deformation are closely depending on the presence of the bio-layer on the internal walls of the capillaries.
4

Synthèse de brosses de polyélectrolytes par polymérisation initiée depuis une surface de mica et étude de leur réponse en fonction du pH et de la force ionique

Lego, Béatrice 11 1900 (has links)
Cette thèse rapporte le greffage chimique de brosses de polymères neutres de poly(acrylate de tert-butyle) (PtBA) et de brosses chargées d’acide polyacrylique (PAA) sur des substrats de mica afin d’étudier leur conformation en fonction de la densité de greffage, du pH et de la force ionique. Le greffage est réalisé par polymérisation contrôlée par transfert d’atome (ATRP) initiée depuis la surface de mica afin de contrôler la croissance du polymère et sa densité de greffage. L’étude de la conformation des brosses de PtBA et de PAA a été menée avec la technique AFM en mesurant les épaisseurs des films à sec et gonflés sous différentes conditions de solvant, de pH et de force ionique. Une monocouche d’amorceurs est tout d’abord greffée sur du mica porteur de groupes hydroxyles créés par plasma (Ar/H2O). Cette couche a été caractérisée par des mesures d’angle de contact et par la technique TOF-SIMS. L’amorceur greffé a ensuite permis d’initier l’ATRP directement depuis la surface pour former des brosses neutres de PtBA liés de façon covalente au mica. La croissance linéaire de l’épaisseur du film avec la masse molaire du polymère en solution et le taux de conversion montre que la polymérisation est contrôlée. De plus, la ré-initiation des chaînes greffées atteste du caractère vivant de la polymérisation. L’hydrolyse des brosses de PtBA, confirmée par des mesures d’angle de contact, d’épaisseur et par FT-IR, conduit à des brosses de PAA. Les différentes couches greffées sont stables à l’air, en milieu organique et en milieu aqueux et leur gonflement est réversible. Le degreffage de la couche de PAA est observé suite à une longue exposition à pH basique. Cette étude représente le premier exemple de brosses greffées chimiquement sur du mica par polymérisation initiée depuis la surface. La variation des paramètres de la réaction de greffage de l’amorceur, tels que la concentration et la durée de réaction, a permis de contrôler le taux de recouvrement de l’amorceur et la densité de greffage du polymère. Une grande gamme de taux de recouvrement de l’amorceur est accessible et se traduit par un intervalle de densités de greffage allant de faibles à élevées (e.g. 0,04 chaîne/nm2 à 0,5 chaîne/nm2). L’étude de la conformation des chaînes de PtBA dans le DMF montre que cet intervalle de densités recouvre le régime crêpe au régime brosse. Le gonflement de brosses de PAA et la variation de la hauteur de la brosse L ont été étudiés en fonction de la densité de greffage, du pH et du sel ajouté cs (NaCl). Une transition brusque de collapsée à étirée est observée avec l’augmentation du pH, indépendamment de la densité de greffage. A pH neutre, les brosses sont collapsées et se comportent comme des brosses neutres en mauvais solvant. A pH basique, les brosses sont gonflées et chargées et se trouvent dans un régime de Pincus caractéristique des polyélectrolytes forts. En présence de sel, les charges sont partiellement écrantées et les répulsions électrostatiques dominent toujours dans la brosse. Cette étude contribue à une meilleure compréhension du comportement complexe des brosses de polyélectrolytes faibles et apporte un soutien expérimental à la théorie sur le comportement de ces brosses. / Neutral polymer brushes of poly(tert-butyl acrylate) (PtBA) and polyelectrolyte brushes of poly(acrylic acid) (PAA) were chemically grafted on mica in order to study their conformation as a function of grafting density, pH and ionic strength. The brushes were prepared via surface-initiated atom-transfer radical polymerization (SI-ATRP). This approach allows the control of the polymer growth and of the polymer grafting density. The study of brush conformation was investigated by measuring the dry and the swollen film thicknesses by Atomic Force microscopy (AFM) under various environmental conditions. Mica substrates were activated by a plasma method leading to OH-functionalized surfaces to which a radical initiator was covalently bound using standard siloxane protocols. The initiator grafting on the mica substrate was confirmed by water contact angle measurements and time-of-flight secondary ion mass spectrometry (TOF-SIMS). The covalently immobilized initiator successfully underwent SI-ATRP with tert-butyl acrylate, yielding end-grafted PtBA brushes that are covalently linked to mica. A linear relationship of the polymer thickness with respect to the molecular weight of the free polymer and with respect to the monomer conversion is obtained confirming that SI-ATRP is well controlled. The PtBA brushes were then hydrolyzed to PAA as confirmed by water contact angle measurements, polymer thickness measurements and FT-IR. The grafted layers show a good stability in air, organic solvent and aqueous solution and a reversible swelling. Film cleavage is observed for long exposure time in basic solution. This study represents the first example of chemically grafted brushes on mica via SI-ATRP. The polymer grafting density of poly(tert-butyl acrylate) was controlled by tuning the initiator surface coverage. By adjusting parameters such as the immobilization reaction time and concentration of the initiator, a wide range of initiator surface coverages and hence polymer densities on mica were possible ranging from 0.04 chain/nm2 to 0.5 chain/nm2). The swelling behavior of PAA brushes was investigated as a function of the polymer grafting density, pH and ionic strength cs (NaCl). A sharp transition from collapsed to stretched conformation was found with increasing pH. At neutral pH, the brushes are collapsed and behave like neutral brushes in poor solvent. At high pH, the brushes are swollen and charged and belong to the Pincus regime. In the presence of salt, the Coulombic repulsions are screened. The observed behavior of PAA brushes resembles the one of strong polyelectrolyte brushes. This study contributes to a better understanding of the complex behaviour of weak polyelectrolyte brushes and brings experimental support to theoretical studies.
5

Synthèse de brosses de polyélectrolytes par polymérisation initiée depuis une surface de mica et étude de leur réponse en fonction du pH et de la force ionique

Lego, Béatrice 11 1900 (has links)
No description available.

Page generated in 0.0656 seconds