• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 9
  • 9
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento e caracterizacao do cristal cintilador de CsI(TI) utilizado como detector de radiacao

PEREIRA, MARIA C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:08Z (GMT). No. of bitstreams: 1 06146.pdf: 4663857 bytes, checksum: db1a9347b09141dd274ecaacdb19b0be (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
2

Desenvolvimento e caracterizacao do cristal cintilador de CsI(TI) utilizado como detector de radiacao

PEREIRA, MARIA C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:08Z (GMT). No. of bitstreams: 1 06146.pdf: 4663857 bytes, checksum: db1a9347b09141dd274ecaacdb19b0be (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
3

The development of a CsI(TI)-photodiode array for remote geochemical sensing

Evans, Robert James January 1999 (has links)
No description available.
4

Desenvolvimento de sondas cirúrgicas radioguiadas com semicondutores de TlBr e com cristais cintiladores de CsI(Tl)

COSTA, FABIO E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:00Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
5

Desenvolvimento de sondas cirúrgicas radioguiadas com semicondutores de TlBr e com cristais cintiladores de CsI(Tl)

COSTA, FABIO E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:00Z (GMT). No. of bitstreams: 0 / As cirurgias radioguiadas, utilizando sondas com detectores de radiação, têm sido destaque na área médica na última década. Esta técnica consiste na marcação de lesões com uma substância radioativa, que injetada no paciente, concentra-se no tumor e auxilia a sua localização durante o ato cirúrgico. Entre as cirurgias radioguiadas, a identificação e exame do linfonodo sentinela, tem revolucionado a conduta de neoplasias em estádio inicial, quando estas estão sendo disseminadas pela via linfática. As condições impostas por uma cirurgia e a proximidade entre alguns linfonodos, exige das sondas, reduzidos diâmetros e capacidade de identificação individual destes linfonodos marcados com um radiofármaco. O mercado internacional fornece sondas adequadas com cristais cintiladores e com semicondutores de telureto de cádmio, CdTe, mas que algumas vezes carecem de uma pronta assistência técnica no mercado brasileiro devido a todo o conjunto ser importado. Este trabalho desenvolveu sondas com tecnologia nacional, utilizando cristais cintiladores de iodeto de césio dopado com tálio, CsI(Tl) e, em substituição aos cristais semicondutores de CdTe, o cristal de brometo de tálio, TlBr que é um meio semicondutor detector em desenvolvimento mundialmente, com vantagens em relação ao CdTe. Ambos os cristais utilizados foram crescidos no IPEN. Toda a eletrônica necessária, e em especial, o pré-amplificador, que constituía também um fator limitante para desenvolvimento destes tipos de sonda no país, foram desenvolvidos com componentes encontrados no mercado nacional. Medidas sistemáticas de resolução espacial, seletividade espacial, sensibilidade máxima e qualidade da blindagem foram realizadas para as sondas desenvolvidas. Os resultados mostraram que dois modelos de sonda, uma com o cristal de CsI(Tl) e outra com o semicondutor de TlBr atenderam as qualidades sugeridas pela literatura internacional para sondas cirúrgicas radioguiadas. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
6

Desenvolvimento de cristais baseados em iodeto de Césio para aplicação como detectores de radiação / Development of crystals based in cesium iodide for application as radiation detectors

Pereira, Maria da Conceição Costa 07 June 2006 (has links)
Cintiladores inorgânicos com tempo de decaimento de luminescência rápido, densidade alta e boa produção de luz têm sido objeto de estudos para aplicações em física nuclear, física de energias altas, tomografia nuclear e outros campos da ciência e da engenharia. Cristais de cintilação baseados em iodeto de césio (Csl) são materiais que apresentam higroscopia relativamente baixa, número atômico alto, fácil manuseio e custo baixo, características que favorecem o seu uso como detectores de radiação. Neste trabalho descreve-se a obtenção de cristais Csl puro, Csl:Br e Csl:Pb, utilizando-se a técnica de Bridgman. A concentração do elemento dopante bromo (Br) foi estudada no intervalo de 1,5x10-1 M a 10-2 M e o elemento chumbo (Pb) no intervalo de 10-2 M a 5x10-4 M. Para avaliar os cintiladores desenvolvidos foram efetuadas medidas sistemáticas de emissão de luminescência e tempo de decaimento de luminescência para a radiação gama, ensaios de transmitância óptica, ensaios de microdureza Vickers, determinações da distribuição dos dopantes ao longo dos cristais crescidos e análise da resposta dos cristais à radiação gama no intervalo de energia de 350 keV a 1330 keV e partículas alfa provenientes de fonte de 241Am com energia de 5,54 MeV. Os resultados obtidos de tempo de decaimento de luminescência para os cristais CsI:Br e CsI:Pb, no intervalo de 13 ns a 19 ns, mostraram-se promissores para medidas de alta energia. O estudo de microdureza mostrou um aumento significativo em função da concentração dos elementos dopantes, quando comparado ao cristal Csl puro, melhorando desta forma a resistência mecânica dos cristais crescidos. A validade de utilização desses cristais como sensores de radiação para medidas de radiação gama e partículas alfa, pode ser demonstrada pelos resultados da resposta à radiação. / Inorganic scintillators with fast luminescence decay time, high density and high light output have been the object of studies for application in nuclear physics, high energy physics, nuclear tomography and other fields of science and engineering. Scintillation crystals based on cesium iodide (CsI) are matters with relatively low higroscopy, high atomic number, easy handling and low cost, characteristics that favor their use as radiation detectors. In this work, the growth of pure CsI crystals, CsI:Br and CsI:Pb, using the Bridgman technique, is described. The concentration of the bromine doping element (Br) was studied in the range of 1,5x10-1 M to 10-2 M and the lead (Pb) in the range of 10-2 M to 5x10-4 M. To evaluate the scintillators developed, systematic measurements were carried out for luminescence emission and luminescence decay time for gamma radiation, optical transmittance assays, Vickers micro-hardness assays, determination of the doping elements distribution along the grown crystals and analysis of crystals response to the gamma radiation in the energy range of 350 keV to 1330 keV and alpha particles from a 241Am source, with energy of 5.54 MeV. It was obtained 13 ns to 19 ns for luminescence decay time for CsI:Br and CsI:Pb crystals. These results were very promising. The results obtained for micro-hardness showed a significant increase in function of the doping elements concentration, when compared to the pure CsI crystal, increasing consequently the mechanical resistance of the grown crystals. The validity of using these crystals as radiation sensors may be seen from the results of their response to gamma radiation and alpha particles.
7

Desenvolvimento de cristais baseados em iodeto de Césio para aplicação como detectores de radiação / Development of crystals based in cesium iodide for application as radiation detectors

Maria da Conceição Costa Pereira 07 June 2006 (has links)
Cintiladores inorgânicos com tempo de decaimento de luminescência rápido, densidade alta e boa produção de luz têm sido objeto de estudos para aplicações em física nuclear, física de energias altas, tomografia nuclear e outros campos da ciência e da engenharia. Cristais de cintilação baseados em iodeto de césio (Csl) são materiais que apresentam higroscopia relativamente baixa, número atômico alto, fácil manuseio e custo baixo, características que favorecem o seu uso como detectores de radiação. Neste trabalho descreve-se a obtenção de cristais Csl puro, Csl:Br e Csl:Pb, utilizando-se a técnica de Bridgman. A concentração do elemento dopante bromo (Br) foi estudada no intervalo de 1,5x10-1 M a 10-2 M e o elemento chumbo (Pb) no intervalo de 10-2 M a 5x10-4 M. Para avaliar os cintiladores desenvolvidos foram efetuadas medidas sistemáticas de emissão de luminescência e tempo de decaimento de luminescência para a radiação gama, ensaios de transmitância óptica, ensaios de microdureza Vickers, determinações da distribuição dos dopantes ao longo dos cristais crescidos e análise da resposta dos cristais à radiação gama no intervalo de energia de 350 keV a 1330 keV e partículas alfa provenientes de fonte de 241Am com energia de 5,54 MeV. Os resultados obtidos de tempo de decaimento de luminescência para os cristais CsI:Br e CsI:Pb, no intervalo de 13 ns a 19 ns, mostraram-se promissores para medidas de alta energia. O estudo de microdureza mostrou um aumento significativo em função da concentração dos elementos dopantes, quando comparado ao cristal Csl puro, melhorando desta forma a resistência mecânica dos cristais crescidos. A validade de utilização desses cristais como sensores de radiação para medidas de radiação gama e partículas alfa, pode ser demonstrada pelos resultados da resposta à radiação. / Inorganic scintillators with fast luminescence decay time, high density and high light output have been the object of studies for application in nuclear physics, high energy physics, nuclear tomography and other fields of science and engineering. Scintillation crystals based on cesium iodide (CsI) are matters with relatively low higroscopy, high atomic number, easy handling and low cost, characteristics that favor their use as radiation detectors. In this work, the growth of pure CsI crystals, CsI:Br and CsI:Pb, using the Bridgman technique, is described. The concentration of the bromine doping element (Br) was studied in the range of 1,5x10-1 M to 10-2 M and the lead (Pb) in the range of 10-2 M to 5x10-4 M. To evaluate the scintillators developed, systematic measurements were carried out for luminescence emission and luminescence decay time for gamma radiation, optical transmittance assays, Vickers micro-hardness assays, determination of the doping elements distribution along the grown crystals and analysis of crystals response to the gamma radiation in the energy range of 350 keV to 1330 keV and alpha particles from a 241Am source, with energy of 5.54 MeV. It was obtained 13 ns to 19 ns for luminescence decay time for CsI:Br and CsI:Pb crystals. These results were very promising. The results obtained for micro-hardness showed a significant increase in function of the doping elements concentration, when compared to the pure CsI crystal, increasing consequently the mechanical resistance of the grown crystals. The validity of using these crystals as radiation sensors may be seen from the results of their response to gamma radiation and alpha particles.
8

Desenvolvimento de cristais baseados em iodeto de césio para aplicação como detectores de radiação

PEREIRA, MARIA da C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:37Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
9

Desenvolvimento de cristais baseados em iodeto de césio para aplicação como detectores de radiação

PEREIRA, MARIA da C.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:37Z (GMT). No. of bitstreams: 0 / Cintiladores inorgânicos com tempo de decaimento de luminescência rápido, densidade alta e boa produção de luz têm sido objeto de estudos para aplicações em física nuclear, física de energias altas, tomografia nuclear e outros campos da ciência e da engenharia. Cristais de cintilação baseados em iodeto de césio (Csl) são materiais que apresentam higroscopia relativamente baixa, número atômico alto, fácil manuseio e custo baixo, características que favorecem o seu uso como detectores de radiação. Neste trabalho descreve-se a obtenção de cristais Csl puro, Csl:Br e Csl:Pb, utilizando-se a técnica de Bridgman. A concentração do elemento dopante bromo (Br) foi estudada no intervalo de 1,5x10-1 M a 10-2 M e o elemento chumbo (Pb) no intervalo de 10-2 M a 5x10-4 M. Para avaliar os cintiladores desenvolvidos foram efetuadas medidas sistemáticas de emissão de luminescência e tempo de decaimento de luminescência para a radiação gama, ensaios de transmitância óptica, ensaios de microdureza Vickers, determinações da distribuição dos dopantes ao longo dos cristais crescidos e análise da resposta dos cristais à radiação gama no intervalo de energia de 350 keV a 1330 keV e partículas alfa provenientes de fonte de 241Am com energia de 5,54 MeV. Os resultados obtidos de tempo de decaimento de luminescência para os cristais CsI:Br e CsI:Pb, no intervalo de 13 ns a 19 ns, mostraram-se promissores para medidas de alta energia. O estudo de microdureza mostrou um aumento significativo em função da concentração dos elementos dopantes, quando comparado ao cristal Csl puro, melhorando desta forma a resistência mecânica dos cristais crescidos. A validade de utilização desses cristais como sensores de radiação para medidas de radiação gama e partículas alfa, pode ser demonstrada pelos resultados da resposta à radiação. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0431 seconds