• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 2
  • Tagged with
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analytical techniques for quality assessment of separated and commingled recycled polymer fractions

Camacho, Walker January 2002 (has links)
Different methods for quality assessment of separated andcommingled plastics from household and electronic waste havebeen developed. Especial attention has been given tospectroscopic methods since they are non-destructive andrequire little or no sample preparation at all. A wide variety of low molecular weight compounds have beenidentified in recycled polyethylene (HDPE) and polypropylenefrom hard packaging waste by gas chromatography- massspectroscopy (GC-MS) after microwave assisted extraction (MAE).Low molecular weight substances such as alcohols, esters,ketones and fragrance and flavour compounds were detected inthe recycled resins. The major category of compounds identifiedin the virgin resins is conformed by aliphatic hydrocarbonssuch as alkanes and alkenes. It was found that theconcentration of aromatic hydrocarbons without functionalgroups, e.g. ethylbenzene and xylenes in recycled HDPE wasapprox. 5 times higher and equal to 120 and 35 ppb,respectively. The potential of near infrared (NIR) and Fourier transformRaman (FT-Raman) spectroscopy in combination with multivariateanalysis as a rapid, non-destructive and accurate analyticalmethod has been studied and the feasibility of these methodsfor at/in line characterisation of several properties ofrecyclates has also been explored. NIR in diffuse reflectance mode has been successfully usedfor quantification of antioxidants in polyethylene, thestandard error of prediction is almost comparable to the errorof wet methods, i.e., extraction plus liquid chromatography.The error of prediction of this method is 35 ppm for Irganox1010 and 68 ppm for Irgafos 168. The inaccuracy in thequantification of Irgafos 168 is due to the fact that thisantioxidant degrades during polymer processing. NIR and Mid-infrared (Mid-IR) worked well for fastdetermination of molecular weight and crystallinity of therecycled HDPE and acceptable errors of prediction, comparableto that of the reference methods, i.e. size exclusionchromatography (SEC) and differential scanning calorimetry(DSC) have been obtained. The present thesis also shows that NIR and Raman are goodcandidates for in/on line compositional analysis of mixedpolymer fractions from recycled plastic waste. Diffusereflectance NIR allows a rapid and reliable measurement ofpellets and requires no previous sample preparation. Thecomposition of binary blends can be determined with highaccuracy. The PP content in the PP/HDPE blends was predictedwith a RMSEP equal to 0.46 %w in the 0-15 %wt region and theRMSEP for PP in the PP/ABS blends was 0.3 %wt. The thermal and thermoxidative stability of recycled PP,HDPE and a 20/80 PP/HDPE blend subjected to multiple extrusionhave been studied by DSC, thermal analysis (TGA) andchemiluminiscence (CL). A decrease in Toxand OIT was observed after each extrusion step.The drop in OIT was sharper after the first two extrusions. TheOIT values produced by DSC and CL were in good agreement.However, CL provided more information about the oxidationprocess taking place in the blends. The moisture content in recycled polyamide 6,6 was readilydetermined by NIR in transmission mode and it could bepredicted with a RMSEP = 0.05 %wt. The accuracy of the methodappeared to be as good as that of the more time consumingthermal methods such as TGA, DSC and loss on dry (LOD), whichwere used as reference methods. The influence of differentamounts of water on the viscoelastic properties of nylon hasbeen investigated. <b>Keywords:</b>Recycling, HDPE, PP, blends, nylon 6,6, ABS,water content, MAE, GC-MS, NIR, FT-Raman, chemiluminiscence,low molecular weight compounds, antioxidant content,crystallinity, molecular weight, thermal stability,characterisation methods, analysis of polymers, blends.
2

Analytical techniques for quality assessment of separated and commingled recycled polymer fractions

Camacho, Walker January 2002 (has links)
<p>Different methods for quality assessment of separated andcommingled plastics from household and electronic waste havebeen developed. Especial attention has been given tospectroscopic methods since they are non-destructive andrequire little or no sample preparation at all.</p><p>A wide variety of low molecular weight compounds have beenidentified in recycled polyethylene (HDPE) and polypropylenefrom hard packaging waste by gas chromatography- massspectroscopy (GC-MS) after microwave assisted extraction (MAE).Low molecular weight substances such as alcohols, esters,ketones and fragrance and flavour compounds were detected inthe recycled resins. The major category of compounds identifiedin the virgin resins is conformed by aliphatic hydrocarbonssuch as alkanes and alkenes. It was found that theconcentration of aromatic hydrocarbons without functionalgroups, e.g. ethylbenzene and xylenes in recycled HDPE wasapprox. 5 times higher and equal to 120 and 35 ppb,respectively.</p><p>The potential of near infrared (NIR) and Fourier transformRaman (FT-Raman) spectroscopy in combination with multivariateanalysis as a rapid, non-destructive and accurate analyticalmethod has been studied and the feasibility of these methodsfor at/in line characterisation of several properties ofrecyclates has also been explored.</p><p>NIR in diffuse reflectance mode has been successfully usedfor quantification of antioxidants in polyethylene, thestandard error of prediction is almost comparable to the errorof wet methods, i.e., extraction plus liquid chromatography.The error of prediction of this method is 35 ppm for Irganox1010 and 68 ppm for Irgafos 168. The inaccuracy in thequantification of Irgafos 168 is due to the fact that thisantioxidant degrades during polymer processing.</p><p>NIR and Mid-infrared (Mid-IR) worked well for fastdetermination of molecular weight and crystallinity of therecycled HDPE and acceptable errors of prediction, comparableto that of the reference methods, i.e. size exclusionchromatography (SEC) and differential scanning calorimetry(DSC) have been obtained.</p><p>The present thesis also shows that NIR and Raman are goodcandidates for in/on line compositional analysis of mixedpolymer fractions from recycled plastic waste. Diffusereflectance NIR allows a rapid and reliable measurement ofpellets and requires no previous sample preparation. Thecomposition of binary blends can be determined with highaccuracy. The PP content in the PP/HDPE blends was predictedwith a RMSEP equal to 0.46 %w in the 0-15 %wt region and theRMSEP for PP in the PP/ABS blends was 0.3 %wt.</p><p>The thermal and thermoxidative stability of recycled PP,HDPE and a 20/80 PP/HDPE blend subjected to multiple extrusionhave been studied by DSC, thermal analysis (TGA) andchemiluminiscence (CL). A decrease in T<sub>ox</sub>and OIT was observed after each extrusion step.The drop in OIT was sharper after the first two extrusions. TheOIT values produced by DSC and CL were in good agreement.However, CL provided more information about the oxidationprocess taking place in the blends.</p><p>The moisture content in recycled polyamide 6,6 was readilydetermined by NIR in transmission mode and it could bepredicted with a RMSEP = 0.05 %wt. The accuracy of the methodappeared to be as good as that of the more time consumingthermal methods such as TGA, DSC and loss on dry (LOD), whichwere used as reference methods. The influence of differentamounts of water on the viscoelastic properties of nylon hasbeen investigated.</p><p><b>Keywords:</b>Recycling, HDPE, PP, blends, nylon 6,6, ABS,water content, MAE, GC-MS, NIR, FT-Raman, chemiluminiscence,low molecular weight compounds, antioxidant content,crystallinity, molecular weight, thermal stability,characterisation methods, analysis of polymers, blends.</p>
3

Vybrané mikrobiální procesy v bioreaktoru / Selected microbial processes in a bioreactor

Klinková, Lucie January 2014 (has links)
This thesis focuses on the study of the influence of selected parameters on the course of microbial cultivation and evaluation of bioprocess. It is divided into two parts. The first part deals with the production of mutant forms of the protein cryptogein yeast Pichia pastoris. The theoretical part summarizes the findings of the yeast P. pastoris and its expression. It also deals with cryptogein that induces defense reactions in plants. In the experimental part was produced mutant cryptogein X24, in which the concentration of each fraction and the ability to transfer sterols. The second part of this thesis is focused on aerobic and anaerobic oxidation of elemental sulfur by Acidithiobacillus ferrooxidans. In the theoretical section, our knowledge on A. ferrooxidans, its metabolism and the importance of ATP in cell metabolism was summarized. In the experimental part, the above bioprocess was monitored using pH, biomass concentration, the rate of oxidation of elemental sulfur the cellular ATP content.
4

Vývoj miniaturizované extrakční metody pro screening netěkavých nitrososloučenin ve sladu pomocí GC-NCD / Development of miniaturized extraction method used for GC-NCD screening of non-volatile nitroso compounds in malt

Malečková, Michaela January 2018 (has links)
The aim of this diploma thesis was to develop a miniaturized extraction method for a fast screening of non-volatile nitroso compounds using gas chromatography with a nitroso specific chemiluminescence detection. According to a final methodology, the samples were prepared by extraction of grinded malt using a mixture of pyridine and acetonitrile in ratio 60:40 (v/v). To enhance volatility of the determined analytes, the two-step derivatization using hexamethyldisalazane and N,O-bis(trimethyl)-trifluoroacetamide was used. The total volume of the sample was 200 l and the preparation time after optimization was in total 80 min. The extraction method was connected to a classification method, which can divide chromatographic peaks into the groups of N-nitroso and C-nitroso compounds, and interfering substances. After application of the methods mentioned above to real malt samples, the specific chromatographic peaks of C-nitroso and N-nitroso compounds were selected. Description of their properties and structure suggestion will be a subject of the following study. Keywords Nitroso compounds, malt, extraction, derivatization, gas chromatography, chemiluminescence detector
5

Metody stanovení nádorových markerů v krevní plazmě a jejich klinický význam při diagnostice / Methods for determination of tumor markers in the blood plasma and their clinical significance in diagnosing

Toman, Karel January 2014 (has links)
The thesis discusses the methods of determination of tumor markers and their clinical importance in medical diagnostics. The theoretical part describes clinically important tumor markers and also the chemiluminescent immunoassay methods used for their determination. The practical part of the thesis describes the introduction of new chemiluminescent methods for the determination of tumor markers in routine operation, evaluates its basic analytical parameters and compares it with the existing immunoturbidimetric method. The practical part also presents results of monitoring of cancer patients with various tumors, which is performed by evaluation of the values of tumor markers. Comparison of our method with other methods within the context of System of external quality control is also documented.
6

Stanovení netěkavých N-nitrosaminů ve sladu / Determination of non-volatile N-nitrosamines in malt

Vavrová, Dominika January 2016 (has links)
The aim of diploma thesis has been development and optimization of method determination of N- nitrososarcosine and N-nitrosoproline in malt by gas chromatography with chemiluminiscence detector. Optimization of extraction method has been performed by response surface method. Quantification has been performed by internal standard method (N-nitrosopipecolic acid, in which matrix effects has been studied. These has been verified in münchen and pilsen malt, therefore matrix-matched calibration has been constructed. The developed method has been aplicated on wheat, münchen and pilsen malt. N- nitrosoproline was detected only in münchen malt and in other cases has been under limit of detection (LOD=4,0 µg/kg). N-nitrososarcosine was in all cases under limit of detection (LOD=3,7 µg/kg). The matrix-matched calibration has been constructed for experimental münchen malt with N-nitrosoproline concentration at 13,2 ± 2,9 µg/kg. Powered by TCPDF (www.tcpdf.org)
7

Stanovení celkové antioxidační aktivity čajových nálevů vybraných druhů čajů / Determination of total antioxidation activity of tea pickles in selected sorts of tea

Bartošová, Jitka January 2009 (has links)
This thesis deals with the total antioxidant activity (TAA) evaluation of various sorts of tea (green, black, half-fermented, white, mate, rooibos and herbal) depending on the process and time of their treatment. The main emphasis is put on testing a new method of measuring the total antioxidant activity by flow coulometry. The results acquired by this method are compared to the results of the chemiluminescent Trolox equivalent antioxidant capacity (TEAC) method which is a standard for measuring the total antioxidant capacity in various materials and raw materials. The work discusses the reasons for the differences in the values found by both methods.

Page generated in 0.0687 seconds