1 |
Chirped-pulse interferometry: Classical dispersion cancellation and analogues of two-photon quantum interferenceLavoie, Jonathan 11 September 2009 (has links)
Interference has long been used for precision measurement of path-length changes. Since the advent of the laser, interference has become one of the most versatile tools in metrology. Specifically, ultra-short laser pulses allow unprecedented resolution in absolute length measurements. While ultra-short laser pulses lead to high resolution, for example in white-light interferometry, they are very susceptible to dispersion.
Quantum resources have been proposed to overcome some of the problems related to distortions in the interferometric signal. For example, the Hong-Ou-Mandel (HOM) interferometer relies on frequency-entangled photon pairs and features automatic even-order dispersion cancellation and high interference visibility resilient to unbalanced loss. Quantum-OCT is a technique based on HOM interferometry, that promises to overcome Optical Coherence Tomography (OCT) a classical imaging technique based on low coherence light. Furthermore, straightforward modifications of the HOM interferometer can display several different interferometric signals, including the HOM peak, quantum beating, and phase super-resolution. However, the quantum resources required are hard to produce and dim, leading to long integration times and single-photon counting.
In this thesis, we introduce the theory behind Chirped-Pulse Interferometry (CPI), a new technique that combines all the advantages of Q-OCT, including even-order dispersion cancellation, but without the need for any quantum resources. We then experimentally implement CPI and demonstrate all the important characteristics shared by the HOM interferometer, but at dramatically larger signal levels. We show how CPI can be used to measure dispersion cancelled axial profiles of an optical sample and show the improvement in resolution over white-light interferometry. Finally, we show that by modifying CPI in analogous ways to HOM, CPI can also be made to produce interferometric signal identical to the HOM peak, quantum beating, and phase super-resolution.
|
2 |
Chirped-pulse interferometry: Classical dispersion cancellation and analogues of two-photon quantum interferenceLavoie, Jonathan 11 September 2009 (has links)
Interference has long been used for precision measurement of path-length changes. Since the advent of the laser, interference has become one of the most versatile tools in metrology. Specifically, ultra-short laser pulses allow unprecedented resolution in absolute length measurements. While ultra-short laser pulses lead to high resolution, for example in white-light interferometry, they are very susceptible to dispersion.
Quantum resources have been proposed to overcome some of the problems related to distortions in the interferometric signal. For example, the Hong-Ou-Mandel (HOM) interferometer relies on frequency-entangled photon pairs and features automatic even-order dispersion cancellation and high interference visibility resilient to unbalanced loss. Quantum-OCT is a technique based on HOM interferometry, that promises to overcome Optical Coherence Tomography (OCT) a classical imaging technique based on low coherence light. Furthermore, straightforward modifications of the HOM interferometer can display several different interferometric signals, including the HOM peak, quantum beating, and phase super-resolution. However, the quantum resources required are hard to produce and dim, leading to long integration times and single-photon counting.
In this thesis, we introduce the theory behind Chirped-Pulse Interferometry (CPI), a new technique that combines all the advantages of Q-OCT, including even-order dispersion cancellation, but without the need for any quantum resources. We then experimentally implement CPI and demonstrate all the important characteristics shared by the HOM interferometer, but at dramatically larger signal levels. We show how CPI can be used to measure dispersion cancelled axial profiles of an optical sample and show the improvement in resolution over white-light interferometry. Finally, we show that by modifying CPI in analogous ways to HOM, CPI can also be made to produce interferometric signal identical to the HOM peak, quantum beating, and phase super-resolution.
|
3 |
The monitoring and multiplexing of fiber optic sensors using chirped laser sourcesWan, Xiaoke 30 September 2004 (has links)
A wide band linearly chirped erbium-doped fiber laser has been developed. The erbium-doped fiber laser using a rotating mirror/grating combination as one of the reflectors in a Fabry-Perot laser cavity has been tuned over a 46 nm spectral range. Linearization of the chirp rate has been achieved using feedback from a fiber Fabry-Perot interferometer (FFPI) to adjust the voltage ramp which drives the rotating mirror. In a demonstration of monitoring an array of two fiber Bragg grating (FBG) sensors, a wavelength resolution of 1.7 pm has been achieved.
The linearly chirped fiber laser has been used in measuring the optical path difference (OPD) of interferometric fiber optic sensors by performing a Fourier transform of the optical signal. Multiplexing of an array of three FFPI sensors of different lengths has been demonstrated, with an OPD resolution ranging from 3.6 nm to 6.3 nm. Temperature was measured with one of the sensors over the range from 20°C to 610°C with a resolution of 0.02°C.
Short FBGs are used to form the two mirrors of a fiber Bragg grating pair interferometer (FBGPI) sensor, so that the mirror reflectances change gradually as a function of temperature. Modulating the drive current of a DFB laser produces chirping of the laser frequency to scan over ~2.5 fringes of the FBGPI reflectance spectrum. Because the fringes are distinguished due to the FBG reflectance change, the ambient temperature can be determined over the range from 24 oC to 367 oC with a resolution of 0.004 oC.
Multiplexing of FBGPI sensors of different lengths with a linearly chirped fiber laser has demonstrated improved sensitivity and multiplexing capacity over a conventional FBG WDM system. The FBG spectral peak position and the phase shift of an FBGPI are determined through the convolution of the sensor reflected signal with an appropriately matched reference waveform, even though the reflectance spectra for the FBGs from different sensors overlap over a wide temperature range. A spectral resolution for the FBG reflectance peak of 0.045 GHz (0.36 pm), corresponding to a temperature resolution of 0.035 oC, has been achieved.
|
Page generated in 0.0792 seconds