• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition

Muhammad Abdullah, Reza 2011 May 1900 (has links)
Biopotential signals are important to physicians for diagnosing medical conditions in patients. Traditionally, biopotentials are acquired using contact electrodes together with instrumentation amplifiers (INAs). The biopotentials are generally weak and in the presence of stronger common mode signals. The INA thus needs to have very good Common Mode Rejection Ratio (CMRR) to amplify the weak biopotential while rejecting the stronger common mode interferers. Opamp based INAs with a resistor-capacitor feedback are suitable for acquiring biopotentials with low power and low noise performance. However, CMRR of such INA topologies is typically very poor. In the presented research, a technique is proposed for improving the CMRR of opamp based INAs in RC feedback configurations by dynamically matching input and feedback capacitor pairs. Two instrumentation amplifiers (one fully differential and the other fully balanced fully symmetric) are designed with the proposed dynamic element matching scheme. Post layout simulation results show that with 1 percent mismatch between the limiting capacitor pairs, CMRR is improved to above 150dB when the proposed dynamic element matching scheme is used. The INAs draw about 10uA of quiescent current from a 1.5 dual power supply source. The input referred noise of the INAs is less than 3uV/sqrt(Hz).
2

Adaptive Suppression of Interfering Signals in Communication Systems

Pelteku, Altin E. 21 April 2013 (has links)
The growth in the number of wireless devices and applications underscores the need for characterizing and mitigating interference induced problems such as distortion and blocking. A typical interference scenario involves the detection of a small amplitude signal of interest (SOI) in the presence of a large amplitude interfering signal; it is desirable to attenuate the interfering signal while preserving the integrity of SOI and an appropriate dynamic range. If the frequency of the interfering signal varies or is unknown, an adaptive notch function must be applied in order to maintain adequate attenuation. This work explores the performance space of a phase cancellation technique used in implementing the desired notch function for communication systems in the 1-3 GHz frequency range. A system level model constructed with MATLAB and related simulation results assist in building the theoretical foundation for setting performance bounds on the implemented solution and deriving hardware specifications for the RF notch subsystem devices. Simulations and measurements are presented for a Low Noise Amplifer (LNA), voltage variable attenuators, bandpass filters and phase shifters. Ultimately, full system tests provide a measure of merit for this work as well as invaluable lessons learned. The emphasis of this project is the on-wafer LNA measurements, dependence of IC system performance on mismatches and overall system performance tests. Where possible, predictions are plotted alongside measured data. The reasonable match between the two validates system and component models and more than compensates for the painstaking modeling efforts. Most importantly, using the signal to interferer ratio (SIR) as a figure of merit, experimental results demonstrate up to 58 dB of SIR improvement. This number represents a remarkable advancement in interference rejection at RF or microwave frequencies.

Page generated in 0.1249 seconds