1 |
Experimental studies of elliptical concrete-filled tube columnsJamaluddin, N., Lam, Dennis, Ye, J. January 2010 (has links)
No
|
2 |
Desempeño sísmico de marcos especiales a momento compuestos (C-SMF) con columnas tubulares cuadradas de acero rellenas de hormigónAñazco Campoverde, Gilbert Adrián January 2018 (has links)
Tesis para optar al grado de Magíster en Ciencias de la Ingeniería, Mención Ingeniería Estructural, Sísmica y Geotécnica / En el presente trabajo de investigación se evalúa el desempeño sísmico y el riesgo de colapso de marcos especiales a momento compuestos (C-SMF), utilizando la metodología de FEMA P695 [24]. Para llevar a cabo este planteamiento como primer punto se realizó el diseño de varias configuraciones de edificios prototipo en 2D de 3, 6, 8, 12 y 16 pisos de altura tomados de una planta típica, ubicados en diferente zonificación sísmica y tipo de suelo, aplicando la norma chilena NCh 433 [25]. Se incluye la no linealidad geométrica (efecto P-Delta) y la no linealidad del material al implementar modelos de plasticidad concentrada basados en fibras utilizando las curvas efectivas de esfuerzo-deformación para dicho fin. Se utilizó el software SAP2000 versión 19.1.1 para llevar a cabo todo el trabajo de investigación.
Como segundo punto se realizaron análisis no lineales estáticos (Pushover) y no lineales dinámicos incrementales (Time History) para obtener el factor de sobreresistencia Ω, la ductilidad 𝜇���𝑇���, la intensidad media de colapso 𝑆���̂𝐶���𝑇���, la razón del margen de colapso CMR y así poder evaluar el desempeño sísmico comparando la razón del margen de colapso ajustado calculada ACMR con los valores admisibles propuestos por FEMA P695 [24]. El propósito de esta metodología es determinar los parámetros de respuesta (𝑅���,𝐶���𝑑���,𝛺���𝑜���) para que cuando sean propiamente implementados en los procesos de diseño, las edificaciones resulten con una seguridad equivalente contra el colapso durante un terremoto de manera similar a la seguridad que brindan los actuales códigos de diseño sísmico. Además, busca afirmar que el sistema estructural analizado asegure la protección de vida cuando posea una baja probabilidad de colapso (<10%) al ser sometida al sismo máximo considerado (MCE) con la finalidad de incluir el sistema C-SMF en normativa nacional para resistir fuerzas laterales inducidas por sismos.
Un total de 30 diseños y 1373 análisis no lineales efectivos repartidos en 18 modelos seleccionados fueron los que se llevaron a cabo. Acorde a los resultados obtenidos, los factores de desempeño sísmico para uso normativo en C-SMF que se recomiendan son: Ωo=3.0, R*=6.0 y Cd=5.5; esto aplicando las limitaciones impuestas por FEMA P695 [24] y ASCE/SEI 7-16 [20]. La evaluación del desempeño fue satisfactoria para todos los casos individuales y grupales; sin embargo, se debe remarcar que los valores de CMR obtenidos disminuirán (aproximadamente en un 50%) si se realiza un Full IDA, lo que provocaría que el valor de CMR para las edificaciones de 16 pisos no cumpla con el criterio de aceptación. Con este antecedente, a criterio del autor, el sistema estructural C-SMF asegura la protección de vida y puede ser incluido en normativa nacional colocando una limitación en altura de 12 pisos.
|
3 |
An experimental study on elliptical concrete filled columns under axial compression.Jamaluddin, N., Lam, Dennis, Dai, Xianghe, Ye, J. January 2013 (has links)
This paper presents the experimental results and observation of elliptical concrete filled tube (CFT) columns subjected to axial compressive load. A total of twenty-six elliptical CFT specimens including both stub and slender composite columns are tested to failure to investigate the axial compressive behaviour. Various column lengths, sectional sizes and infill concrete strength are used to quantify the influence of member geometry and constituent material properties on the structural behaviour of elliptical CFT columns. As there is no design guidance currently available in any Code of Practice, this study provides a review of the current design rules for concrete filled circular hollow sections in Eurocode 4 (EC4). New equations based on the Eurocode 4 provisions for concrete filled circular hollow sections were proposed and used to predict the capacities of elliptical CFT columns.
|
4 |
Estudo do comportamento de ligações viga-pilar preenchido submetidas a ações cíclicas / Study on behavior of steel beam to CFT column connection subjected to cyclic loadingKataoka, Marcela Novischi 28 June 2011 (has links)
No presente trabalho foi analisado o comportamento de ligações viga-pilar em estruturas mistas de aço e concreto com o auxílio de simulação numérica e experimentação. A simulação numérica foi realizada no programa DIANA, baseado no método dos Elementos Finitos. Os modelos de ligações analisados são compostos por ligações com parafusos passantes entre pilares metálicos preenchidos com concreto e vigas metálicas. A laje utilizada foi do tipo com fôrma de aço incorporada, com a utilização de conectores de cisalhamento para resistir aos esforços em conjunto com a viga. Para simular a situação de pilar intermediário, foram utilizados modelos com formato cruciforme, os quais foram submetidos à força cíclica reversível com a finalidade de submeter à estrutura a esforços semelhantes aos provocados por vento e sismo. Além do efeito da força cíclica, este trabalho avaliou também a influência na rigidez da ligação causada pela taxa de armadura da laje e pelo detalhe de ancoragem da armadura de continuidade ao pilar misto. Para isso foram ensaiados quatro modelos. Dentro da metodologia proposta, obteve-se numérica e experimentalmente, dados que permitiram a construção de curvas momento versus rotação e força versus deslocamento para a quantificação da rigidez e determinação da ductilidade da ligação. Como resultado das análises concluiu-se que a laje contribui mais na rigidez da ligação quando ela está submetida a momento fletor positivo e com relação ao método de ancoragem não houve diferença significativa nas rigidezes. / This research studied the behavior of beam-column connection in composite steel-concrete structures and was developed with the use of numerical simulation and experimentation. The numerical simulation was performed using the program DIANA which is based on the finite element method. The models are composed of connections with bolts passing through the concrete filled tube (CFT) column and steel beams with a steel deck. It was used shear connectors for the slab works together with the beam to resist the bend. To simulate the situation of the middle column, they are used models with cruciform form, which were subjected to reversible cyclic loading in order to bring structure the efforts similar to those caused by wind and earthquake. Besides the effect of cyclic loading, this research also evaluated the influence on the connection stiffness caused by the slab reinforcement ratio and anchors detail to the column of some bars. To obtain this information four models were tested. Within the proposed methodology numerical and experimental data were obtained which made possible the construction of moment versus rotation curves and loading versus displacement for the quantification of stiffness and ductility of the connections. The result of this research shows that the slab contributes more on the increase of stiffness when the connection is subjected to sagging moment and about the method of anchoring, there is no significant difference on stiffness between the two methods.
|
5 |
Estudo do comportamento de ligações viga-pilar preenchido submetidas a ações cíclicas / Study on behavior of steel beam to CFT column connection subjected to cyclic loadingMarcela Novischi Kataoka 28 June 2011 (has links)
No presente trabalho foi analisado o comportamento de ligações viga-pilar em estruturas mistas de aço e concreto com o auxílio de simulação numérica e experimentação. A simulação numérica foi realizada no programa DIANA, baseado no método dos Elementos Finitos. Os modelos de ligações analisados são compostos por ligações com parafusos passantes entre pilares metálicos preenchidos com concreto e vigas metálicas. A laje utilizada foi do tipo com fôrma de aço incorporada, com a utilização de conectores de cisalhamento para resistir aos esforços em conjunto com a viga. Para simular a situação de pilar intermediário, foram utilizados modelos com formato cruciforme, os quais foram submetidos à força cíclica reversível com a finalidade de submeter à estrutura a esforços semelhantes aos provocados por vento e sismo. Além do efeito da força cíclica, este trabalho avaliou também a influência na rigidez da ligação causada pela taxa de armadura da laje e pelo detalhe de ancoragem da armadura de continuidade ao pilar misto. Para isso foram ensaiados quatro modelos. Dentro da metodologia proposta, obteve-se numérica e experimentalmente, dados que permitiram a construção de curvas momento versus rotação e força versus deslocamento para a quantificação da rigidez e determinação da ductilidade da ligação. Como resultado das análises concluiu-se que a laje contribui mais na rigidez da ligação quando ela está submetida a momento fletor positivo e com relação ao método de ancoragem não houve diferença significativa nas rigidezes. / This research studied the behavior of beam-column connection in composite steel-concrete structures and was developed with the use of numerical simulation and experimentation. The numerical simulation was performed using the program DIANA which is based on the finite element method. The models are composed of connections with bolts passing through the concrete filled tube (CFT) column and steel beams with a steel deck. It was used shear connectors for the slab works together with the beam to resist the bend. To simulate the situation of the middle column, they are used models with cruciform form, which were subjected to reversible cyclic loading in order to bring structure the efforts similar to those caused by wind and earthquake. Besides the effect of cyclic loading, this research also evaluated the influence on the connection stiffness caused by the slab reinforcement ratio and anchors detail to the column of some bars. To obtain this information four models were tested. Within the proposed methodology numerical and experimental data were obtained which made possible the construction of moment versus rotation curves and loading versus displacement for the quantification of stiffness and ductility of the connections. The result of this research shows that the slab contributes more on the increase of stiffness when the connection is subjected to sagging moment and about the method of anchoring, there is no significant difference on stiffness between the two methods.
|
6 |
Estudio experimental del pandeo de perfiles tubulares rectangulares de acero, rellenos de hormigón de alta resistencia, bajo carga axial y diagrama de momentos variablesHernández Figueirido, David 17 February 2012 (has links)
El empleo de estructuras mixtas de acero-hormigón ha experimentado un aumento creciente en las últimas décadas, dado qu permiten un mejor aprovechamiento de las características de los materiales empleados, en comparación con estructuras de hormigón armado y acero trabajando de forma independiente.
Este trabajo de investigación se centra en el estudio y análisis de pilares mixtos de tipo perfil tubular de acero, CFT (Concrete Filled Tube), rectangular o cuadrado, rellenos de hormigón de alta resistencia. Este tipo de pilares cuenta con ventajas respecto a otros pilares mixtos como el hecho de que el perfil de acero sirve de enconfrado para el núcleo de hormigón y a su vez, cuenta con suficiente capacidad resistente como para soportar las cargas exixtentes en fase de construcción. Todo ello permite un importante ahorro, tanto económico, como en las plazos de ejecución. Otras ventajas de estos pilares es que el perfil tubular confina el núcleo de hormigón y este a su vez evita que se produzca el pandeo local del tubo de acero, permitiendo así su plastificación y máximo aprovechamiento. Estas ventajas, proporcionan a los soportes ductibilidad característica muy importante frente a la acción sísima, de ahí que el uso de este tipo de pilares se haya extendido en países como Japón, Estados Unidos y China. Es importante, también, destacar el aumento de resistencia al fuego del sistema en comparación con un perfil de acero hueco.
A partir del análisis del estado actual del conocimiento se ha planteado una campaña experiemental que cubre los aspectos no estudiados hasta el momento, y que constituyen los casos más habituales en la práctica real: soportes esbeltos o semiesbeltos sometidos a carga axial y diagrama de momentos no constante. En total se han efectuado 78 ensayos sobre pilares mixtos. Los resultados experimentales se comparan con las previsiones de las normativas de referencia más importantes para el cálculo de pilares mixtos: EC4, AISC 2010, BS5-400:2005, AS5100-6, DBJ13-51, etc, comprobando su validez para el tipo de pilar estudiado.
Finalmente se ha planteado un modelo de cálculo simplificado basado en el
método de amplificación de momentos y se ha ajustado el factor de rigidez a
flexión de los pilares, así como un factor de conversión a diagrama de momentos
constantes. / Hernández Figueirido, D. (2012). Estudio experimental del pandeo de perfiles tubulares rectangulares de acero, rellenos de hormigón de alta resistencia, bajo carga axial y diagrama de momentos variables [Tesis doctoral]. Editorial Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/14724
|