• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise da resistência ao fogo de blocos de alvenaria cerâmica de vedação utilizando proteção de tinta intumescente

Carlos Alexandre Santos Sales 30 March 2016 (has links)
Os incêndios estão presentes na história de várias cidades do mundo e, em algumas delas, chegaram a protagonizar mudanças significativas no desenho urbano e nas características construtivas de suas edificações. No Brasil, o conhecimento sobre segurança contra incêndio em edificações só se tornou assunto de importância após duas grandes tragédias nacionais: os incêndios nos edifícios Andraus (em 1972, com dezesseis mortos) e Joelma (em 1974, com cento e oitenta e nove mortos), ambos na cidade de São Paulo. Atualmente, após a tragédia ocorrida na boate Kiss em Santa Maria - RS em 2013, que culminou com a morte de 242 jovens, muitas alterações nas legislações estaduais de proteção contra incêndio estão sendo sugeridas no Congresso Nacional e nas Assembleias Legislativas Estaduais, porém, em sua maioria, sem respaldo científico e normativo. Juntamente com as mudanças legislativas, muitos produtos e equipamentos surgem diariamente com o objetivo de proteger a vida humana e o patrimônio histórico e cultural. Nesse sentido, surgem as proteções passivas por tintas intumescentes que, conforme se verifica com os resultados desse trabalho, possuem a propriedade de manter o conforto e isolamento térmico adequados, além de manter a resistência a compressão e capacidade máxima de carga dos blocos cerâmicos de vedação em níveis aceitáveis pela norma brasileira, após a exposição direta a chama durante um período de 60 minutos. / Fires are present in the history of cities around the world, and some of them came to star in significant changes in urban design and the construction characteristics of their buildings. In Brazil, the knowledge Fire Safety in buildings only became a matter of importance after two great national tragedies: fires in Andraus buildings (in 1972, with sixteen dead) and Joelma (in 1974 with one hundred eighty-nine dead) both in São Paulo. Currently, after the tragedy at Kiss nightclub in Santa Maria - RS in 2013, which culminated in the death of 242 young people, many changes in state laws fire protection are being suggested in Congress and in State Legislative Assemblies, however, in mostly without scientific and regulatory support. Along with legislative changes, many products and equipment appear daily in order to protect human life and the historical and cultural heritage. In this sense, there are passive protections for intumescent coatings that, as evidenced by the results of this work, have the property to maintain comfort and thermal insulation appropriate, while maintaining resistance to compression and maximum load capacity of sealing ceramic blocks at acceptable levels by the Brazilian standard, after direct exposure to flame for a period of 60 minutes.
2

Análise da resistência ao fogo de blocos de alvenaria cerâmica de vedação utilizando proteção de tinta intumescente

Sales, Carlos Alexandre Santos 30 March 2016 (has links)
Made available in DSpace on 2017-06-01T17:57:36Z (GMT). No. of bitstreams: 1 carlos_alexandre_santos_sales.pdf: 4056461 bytes, checksum: 353a15499589396f6deff6860ff0459e (MD5) Previous issue date: 2016-03-30 / Fires are present in the history of cities around the world, and some of them came to star in significant changes in urban design and the construction characteristics of their buildings. In Brazil, the knowledge Fire Safety in buildings only became a matter of importance after two great national tragedies: fires in Andraus buildings (in 1972, with sixteen dead) and Joelma (in 1974 with one hundred eighty-nine dead) both in São Paulo. Currently, after the tragedy at Kiss nightclub in Santa Maria - RS in 2013, which culminated in the death of 242 young people, many changes in state laws fire protection are being suggested in Congress and in State Legislative Assemblies, however, in mostly without scientific and regulatory support. Along with legislative changes, many products and equipment appear daily in order to protect human life and the historical and cultural heritage. In this sense, there are passive protections for intumescent coatings that, as evidenced by the results of this work, have the property to maintain comfort and thermal insulation appropriate, while maintaining resistance to compression and maximum load capacity of sealing ceramic blocks at acceptable levels by the Brazilian standard, after direct exposure to flame for a period of 60 minutes. / Os incêndios estão presentes na história de várias cidades do mundo e, em algumas delas, chegaram a protagonizar mudanças significativas no desenho urbano e nas características construtivas de suas edificações. No Brasil, o conhecimento sobre segurança contra incêndio em edificações só se tornou assunto de importância após duas grandes tragédias nacionais: os incêndios nos edifícios Andraus (em 1972, com dezesseis mortos) e Joelma (em 1974, com cento e oitenta e nove mortos), ambos na cidade de São Paulo. Atualmente, após a tragédia ocorrida na boate Kiss em Santa Maria - RS em 2013, que culminou com a morte de 242 jovens, muitas alterações nas legislações estaduais de proteção contra incêndio estão sendo sugeridas no Congresso Nacional e nas Assembleias Legislativas Estaduais, porém, em sua maioria, sem respaldo científico e normativo. Juntamente com as mudanças legislativas, muitos produtos e equipamentos surgem diariamente com o objetivo de proteger a vida humana e o patrimônio histórico e cultural. Nesse sentido, surgem as proteções passivas por tintas intumescentes que, conforme se verifica com os resultados desse trabalho, possuem a propriedade de manter o conforto e isolamento térmico adequados, além de manter a resistência a compressão e capacidade máxima de carga dos blocos cerâmicos de vedação em níveis aceitáveis pela norma brasileira, após a exposição direta a chama durante um período de 60 minutos.

Page generated in 0.2137 seconds