• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An integrated combined governor/AVR system

Lown, Mark January 1998 (has links)
No description available.
2

Estabilização de oscilações de potencia de linhas de intercambio atraves de um elo de corrente continua / Stabilization of power lines interchange oscillations through a direct-current link

Paccini, Rodrigo de Oliveira 09 April 2009 (has links)
Orientador: Vivaldo Fernando da Costa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-14T11:14:17Z (GMT). No. of bitstreams: 1 Paccini_RodrigodeOliveira_M.pdf: 1988341 bytes, checksum: 7be3a801c003202ec884c8313b60ac5f (MD5) Previous issue date: 2009 / Resumo: Quando um sistema interligado de corrente alternada sofre variações de carga, sua freqüência pode exibir um comportamento oscilatório. Se este mesmo sistema possuir um elo de corrente contínua em paralelo com as linhas de intercâmbio, esse efeito poderá ser atenuado devido à atuação do controlador de corrente do elo. Esta tese apresenta um estudo que avalia a eficiência de um elo de CC para o amortecimento de oscilações de freqüência de intercâmbio sob condições de pequenas perturbações, operando o sistema com Controle Automático de Geração (CAG). Um modelo de injeção de potência utilizado para representar o elo CC é implementado no Modelo de Sensibilidade de Potência (MSP). Uma das vantagens desse modelo é permitir o desacoplamento da rede em duas partes distintas: o balanço ativo e o balanço reativo, em que as duas podem ser tratadas juntas ou separadamente. Com a escolha desse modelo, tornou-se possível implementar toda a rede no formato de diagrama de blocos. Além disso, as barras de carga do sistema são acessíveis através do diagrama de blocos, o que torna possível variar também a característica da carga. Através dessa representação, tornou-se viável a inserção do elo de CC no diagrama de blocos, pois o mesmo foi modelado como uma injeção de potência nas barras terminais nos balanços ativo e reativo, fechando um novo balanço de potência. As análises no domínio do tempo foram realizadas no programa Matlab Simulink®. Também utilizando este software, um controlador de amortecimento de oscilações de potência (POD-Power Oscillation Damping Controller) foi projetado para a modulação da potência do elo de CC. Os resultados obtidos mostram que o elo de CC possui um grande potencial para a manutenção do amortecimento de oscilações de freqüência de modo inter-área, quando equipados com controladores POD. / Abstract: When an interconnected alternate-current power system suffers variations of loads, its frequency can exhibit an oscillatory behavior. If this system possesses a direct-current link in parallel with the inter-tie lines, this effect could be decreased, due to the link current controller action. This work presents a study that evaluates the efficiency of DC link for the damping of interarea frequency oscillations under small disturbances, operating the system with automatic generation control (AGC). A DC power injection model is implemented in the Power Sensitivity Model (PSM). One of the advantages of this model is to allow the detach of the network in two distinct parts: the active and reactive balances, where the two can be dealt together or separately. With the choice of this model, it's possible to implement the complete network in the block diagram format. Moreover, the network load bus are accessible through the block diagram, which this are possible to vary the load characteristic. Through this representation, the insertion of DC link in the block diagram became viable, therefore it was modeled as a power injection in the terminals bus in the active and reactive balances, closing a new power balance. The time domain analysis is carried out the software Matlab Simulink®. Also using this software, a POD controller (Power Oscillation Damping Controller) was designed for the DC power modulation. The results show that DC link comprises a great potential for the maintenance of frequency oscillations damping in interarea mode, when coupled to POD controllers. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
3

Analys av standarden IEC 61850 för styrning av elkraftsystem / Analysis of the standard IEC 61850 for control of electrical power system

Rigi, Aref, Jura, Bahnam January 2019 (has links)
På uppdrag av Trafikverket har denna rapport syftet att ge en rekommendation baserat på jämförelse av nuvarande standarden IEC 60870-5-104 och den alternativa standarden IEC 61850. Studien jämför IEC 61850 och IEC 60870-5-104 och skillnader mellan dessa två standarder utifrån olika områden som kommunikation, säkerhet samt ekonomiska aspekter. I arbetets teoridel behandlas elnätet och hur elstationer i allmänhet fungerar utifrån kommunikationsprotokollen och hur systemen kommunicerar med andra enheter. Resultatet av arbetet visar att standarden IEC 61850 erbjuder stora möjligheter och fördelar i samtliga aspekter, och har även en utvecklingspotential. Med kommunikationsprotokollet IEC 61850 erhålls mer information i form av feltyp, direkta mätningar och styrning på kontrollanläggningar. Dock finns det en komplexitet i IEC 61850 som kan kräva större anpassningar för att ersätta tidigare protokoll på anläggningar vid byte. Utifrån säkerhetsaspekten uppvisar IEC 61850 styrka bland annat gällande skydd av integritet och konfidentialitet. Sammantaget visar arbetet att det finns stor fördel att använda sig av IEC 61850 vid framtida tillämpningar utifrån examensarbetets resultat / On behalf of the Swedish Transport Administration (Trafikverket), this report aims to provide a recommendation based on a comparison of the current communication protocol standard IEC 60870-5-104 and the alternative standard IEC 61850. This study compares IEC 61850 and IEC 60870-5-104 and differences between these two standards based on different areas such as communication, security and economic aspects. In the theoretical part of this thesis, the electricity grid is treated and how electricity stations generally work based on the communication protocols and how the systems communicate with other devices. The result of the thesis shows that the standard IEC 61850 offers great opportunities and advantages in all aspects and has a potential for development. With the communication protocol IEC 61850, more information is obtained in form of error type, direct measurements and control at control plants. However, there is a complexity in IEC 61850 which may require major adaptations to replace previous protocols on plants when changes are needed. Based on the safety aspect, IEC 61850 shows strength among other things regarding protection of privacy and confidentiality. Overall, the work shows that there is a great advantage of applying IEC 61850 in future use based on this thesis results.

Page generated in 0.1125 seconds