1 |
Numerical modelling of mantle convection and the geoidCraig, C. H. January 1985 (has links)
No description available.
|
2 |
Density-Dependent Convective Flow in Closed BasinsMcCleary, Kim L. 01 May 1989 (has links)
The Great Basin is a region of the Basin and Range Physiographic Province, which is completely isolated hydrologically from the sea. All precipitation that falls within the Great Basin is lost from the land surface or from the surf ace of closed inland lakes through evapotranspiration. Playas are often found at the base of these undrained basins. This study focuses on subsurface groundwater flow patterns in closed basins. Because all discharge from the basins occurs via evapotranspiration on and near the playa, the water table of the aquifer beneath the playa is often just below the ground surface. Fluctuations of the water table due to climatic events cause the water table to rise and dissolve the salts on the playa surface. This mass transfer can produce density gradients that in turn cause flow.
This study is an extension of the work performed by Duffy and Al-Hassan (Duffy and Al-Hassan 1988) in which numerical experiments were used to show that the free convection, caused by the variation in density of the bulk fluid propenies, appears to play an important role in determining the patterns of groundwater flow beneath the playa. Their work considered only homogeneous, isotropic porous media in symmetric basins. The effects of anisotropy, periodic stratification, and asymmetric basins on the groundwater flow and transport patterns was studied here. Dimensionless parameters, the Rayleigh number and the salt nose length, L0*, were defined for each of the systems incorporated and were shown to be linearly related. The implication of this relationship is that the Rayleigh number can be used to predict basin-scale circulation patterns in the hypothetical closed basins studied. It was also determined that an equivalent anisotropic system could be defined for a horizontally stratified aquifer in order to predict basin-scale circulation patterns. An equivalent isotropic system was defined for each anisotropic system in a similar manner.
|
3 |
NEW DEVELOPMENTS OF BIOTRICKLING FILTERS: EXPERIMENTS AND THEORIESFANG, YUANXIANG 22 May 2002 (has links)
No description available.
|
4 |
Convective Flow Patterns of a Three Generation Bifurcation ModelShupe, Andrew C. January 2012 (has links)
No description available.
|
5 |
Um estudo experimental da ebulição convectiva de refrigerantes no interior de tubos lisos e internamente ranhurados / An experimental study of convective flow boiling of refrigerants inside smooth and microfin tubesBandarra Filho, Enio Pedone 29 April 2002 (has links)
A presente pesquisa trata de um estudo experimental da transferência de calor e da perda de carga de fluidos refrigerantes puros e suas misturas em mudança de fase convectiva no interior de tubos lisos e aqueles dotados de ranhuras internas. Para tanto, foi desenvolvido um equipamento experimental cujo componente básico é composto por um tubo horizontal, aquecido por intermédio de uma resistência elétrica do tipo fita, aderida à superfície externa do tubo. As condições de ensaio variaram numa ampla faixa, permitindo cobrir as condições verificadas na maioria das instalações frigoríficas. Os resultados experimentais foram agrupados em duas faixas de velocidades mássicas: elevadas (G > ou = 200 kg/s.m2), onde prepondera o padrão anular de escoamento, e reduzidas (G < 200 kg/s.m2), predominando o padrão estratificado. Os principais parâmetros que afetam o coeficiente de transferência de calor, tais como, velocidade mássica, fluxo de calor, tipo de refrigerante, temperatura de evaporação e diâmetro do tubo foram analisados. O desempenho termo-hidráulico, relativo ao efeito combinado da transferência de calor e da perda de carga dos tubos ranhurados, foi sensivelmente superior quando comparados aos tubos lisos. A análise dos resultados experimentais permitiu a proposição de correlações para a perda da carga, avaliada através do multiplicador bifásico, φL, e para coeficiente de transferência de calor, em tubos lisos e ranhurados. As correlações propostas se mostraram adequadas para aplicações práticas, proporcionando desvios reduzidos em relação aos resultados experimentais. Destacam-se as correlações obtidas para o multiplicador bifásico para tubos microaletados e para o coeficiente de transferência de calor para vazões reduzidas em tubos lisos. Diversos registros fotográficos dos principais padrões de escoamento foram levantados, tendo sido importante na análise e entendimento da mudança de fase. / Present research deals with an experimental study of the heat transfer and pressure drop of pure and mixtures of refrigerants undergoing convective boiling inside horizontal smooth and microfin tubes. An experimental apparatus has been developed and constructed whose main component is a horizontal tube electrically heated. Experimental results have been grouped into two mass velocity ranges: the one corresponding to mass velocities lower than 200 kg/s.m2, where the stratified flow pattern is dominant, and that for mass velocities higher than 200 kg/s.m2, where typically the annular flow pattern can be found. Effects over the heat transfer coefficient of physical parameters such as mass velocity, heat flux, diameter, saturation temperature, and refrigerant have been investigated and analyzed. It has been found out that the thermo-hydraulic performance of microfin tubes is better than that of the smooth ones. Empirical correlations have been proposed for both the two-phase flow multiplier and the heat transfer coefficient for different ranges of operating conditions as well as for smooth and microfin tubes. Results from the proposed correlations can be deemed adequate for practical applications given the limited dispersion obtained with respect to their experimental counterpart. Noteworthy are the results obtained from correlations for both the two phase flow multiplier for microfin tubes and the heat transfer coefficient for the lower range of mass velocities in smooth tubes. Finally, worth mentioning is the photographic essay developed in present research involving the flow patterns that occur under convective boiling of refrigerants in horizontal tubes.
|
6 |
Um estudo experimental da ebulição convectiva de refrigerantes no interior de tubos lisos e internamente ranhurados / An experimental study of convective flow boiling of refrigerants inside smooth and microfin tubesEnio Pedone Bandarra Filho 29 April 2002 (has links)
A presente pesquisa trata de um estudo experimental da transferência de calor e da perda de carga de fluidos refrigerantes puros e suas misturas em mudança de fase convectiva no interior de tubos lisos e aqueles dotados de ranhuras internas. Para tanto, foi desenvolvido um equipamento experimental cujo componente básico é composto por um tubo horizontal, aquecido por intermédio de uma resistência elétrica do tipo fita, aderida à superfície externa do tubo. As condições de ensaio variaram numa ampla faixa, permitindo cobrir as condições verificadas na maioria das instalações frigoríficas. Os resultados experimentais foram agrupados em duas faixas de velocidades mássicas: elevadas (G > ou = 200 kg/s.m2), onde prepondera o padrão anular de escoamento, e reduzidas (G < 200 kg/s.m2), predominando o padrão estratificado. Os principais parâmetros que afetam o coeficiente de transferência de calor, tais como, velocidade mássica, fluxo de calor, tipo de refrigerante, temperatura de evaporação e diâmetro do tubo foram analisados. O desempenho termo-hidráulico, relativo ao efeito combinado da transferência de calor e da perda de carga dos tubos ranhurados, foi sensivelmente superior quando comparados aos tubos lisos. A análise dos resultados experimentais permitiu a proposição de correlações para a perda da carga, avaliada através do multiplicador bifásico, φL, e para coeficiente de transferência de calor, em tubos lisos e ranhurados. As correlações propostas se mostraram adequadas para aplicações práticas, proporcionando desvios reduzidos em relação aos resultados experimentais. Destacam-se as correlações obtidas para o multiplicador bifásico para tubos microaletados e para o coeficiente de transferência de calor para vazões reduzidas em tubos lisos. Diversos registros fotográficos dos principais padrões de escoamento foram levantados, tendo sido importante na análise e entendimento da mudança de fase. / Present research deals with an experimental study of the heat transfer and pressure drop of pure and mixtures of refrigerants undergoing convective boiling inside horizontal smooth and microfin tubes. An experimental apparatus has been developed and constructed whose main component is a horizontal tube electrically heated. Experimental results have been grouped into two mass velocity ranges: the one corresponding to mass velocities lower than 200 kg/s.m2, where the stratified flow pattern is dominant, and that for mass velocities higher than 200 kg/s.m2, where typically the annular flow pattern can be found. Effects over the heat transfer coefficient of physical parameters such as mass velocity, heat flux, diameter, saturation temperature, and refrigerant have been investigated and analyzed. It has been found out that the thermo-hydraulic performance of microfin tubes is better than that of the smooth ones. Empirical correlations have been proposed for both the two-phase flow multiplier and the heat transfer coefficient for different ranges of operating conditions as well as for smooth and microfin tubes. Results from the proposed correlations can be deemed adequate for practical applications given the limited dispersion obtained with respect to their experimental counterpart. Noteworthy are the results obtained from correlations for both the two phase flow multiplier for microfin tubes and the heat transfer coefficient for the lower range of mass velocities in smooth tubes. Finally, worth mentioning is the photographic essay developed in present research involving the flow patterns that occur under convective boiling of refrigerants in horizontal tubes.
|
Page generated in 0.0481 seconds