Análise do desempenho de equipamentos nacionais operando em sistemas de bombeamento fotovoltaico

CRUZ, Tito Ângelo Lobão January 2006 (has links)
Made available in DSpace on 2014-06-12T23:17:07Z (GMT). No. of bitstreams: 2 arquivo9121_1.pdf: 2152523 bytes, checksum: 4b5de0abfff912674f9a41abf609c71f (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / A utilização da energia solar para o bombeamento de água é uma atividade interessante do ponto de vista social, produtivo e ecológico. Porém, o alto custo, a baixa eficiência dos sistemas e os projetos inadequados restringem sua aplicação. Este trabalho apresenta uma proposta de uso de equipamentos nacionais em sistemas de bombeamento fotovoltaico em substituição aos equipamentos importados dedicados a essa aplicação. Com o objetivo de se ter uma utilização mais eficiente de seus equipamentos é necessário conhecer o comportamento operacional dos componentes do SBFV e dos acoplamentos entre eles. Assim, através de procedimentos experimentais, foi realizado um levantamento das características operacionais do sistema instalado com diferentes configurações. Após a caracterização dos componentes do sistema foi realizada uma comparação técnica experimental entre os sistemas importado dedicado e o convencional nacional de mercado. O inversor dedicado conta com um controle que leva o gerador FV a operar em seu ponto de máxima potência, enquanto o conversor convencional é programado para fazer o sistema operar em uma tensão fixa. O resultado desse experimento mostrou que o conversor convencional tem desempenho semelhante ao inversor especial, desde que opere em um valor de tensão adequado. Uma análise dos resultados obtidos mostra que somente a consideração do comportamento do gerador não é suficiente para obter a melhor tensão fixa de operação do sistema. Verificou-se que 270V é a melhor tensão de operação para o gerador, mas a operação em 285V apresentou o maior volume de água bombeado dentre os valores ensaiados. Neste trabalho também é feita uma análise econômica preliminar dos sistemas estudados. Os resultados dessa análise mostram que o custo do volume de água bombeado é menor para o sistema nacional, sobretudo pelo fato de que este sistema conta com equipamentos mais baratos, robustos e de manutenção barata e facilmente encontrada no mercado. Também são levantadas as curvas características das motobombas utilizadas para várias freqüências de operação. Este resultado é muito importante para projetos de sistemas de bombeamento FV, uma vez que estes dados não são fornecidos pelos fabricantes
2

Operação do conjunto bomba centrífuga, motor de indução trifásico e conversor de freqüência visando a eficiência no uso da energia elétrica / Operation set centrifugal pump, three-phase induction motor and frequency converter aimed at efficient use of electricity

Schmidlin Júnior, Celso Rogério 03 November 2006 (has links)
SCHMIDLIN JÚNIOR, C. R. Operação do conjunto bomba centrífuga, motor de indução trifásico e conversor de freqüência visando a eficiência no uso da energia elétrica. 2006. 119 f. Dissertação (Mestrado em Engenharia Elétrica) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-08T14:38:00Z No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-20T18:52:42Z (GMT) No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) / Made available in DSpace on 2016-07-20T18:52:42Z (GMT). No. of bitstreams: 1 2006_dis_crschmidlinjúnior.pdf: 1842220 bytes, checksum: 6a20ad6bd1195abf59a5536f6c9d4c0c (MD5) Previous issue date: 2006-11-03 / This work aims to experimentally quantify, in LAMOTRIZ, the reduction of the active power required by the drive of a centrifugal pump that opts for the operation according to the outflow reduction method by speed variation instead the one that uses strangulation valve. Moreover, aims to develop a mathematical model that is capable to previously determine the consumption of electric energy of a pumping system that operates according to any one of these two methods of outflow reduction. / Este trabalho visa, por meio de ensaios realizados no LAMOTRIZ, quantificar a redução da potência ativa requerida pelo elemento acionador de uma bomba centrífuga que opta pela operação segundo o método de redução de vazão via variação de velocidade ao invés do que usa válvula de estrangulamento. Ainda, objetiva desenvolver um modelo matemático que seja capaz de determinar previamente o consumo de energia elétrica de um sistema de bombeamento que opere segundo qualquer um desses dois métodos de redução de vazão.
3

Aplicação da lógica fuzzy no controle da cristalização de um sistema de refrigeração por absorção com par brometo de lítio / Appication of fuzzy logic in control the crystallization of an absorption refrigeration system with pair water lithium bromide

Marques, João Erivando Soares 01 December 2010 (has links)
Made available in DSpace on 2015-05-08T15:00:02Z (GMT). No. of bitstreams: 1 parte1.pdf: 2575179 bytes, checksum: 8796ecfea1de6030d7f2f9efa941e491 (MD5) Previous issue date: 2010-12-01 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This work presents theoretical and experimental study of a system of control for a steam generator. This system was developed to control the crystallization of a cooling system for absorption. The control system maintains the pressure generator above the zone of crystallization of diagram temperature pressure-saturated solution concentration of LiBr-water. The control is accomplished through simultaneous use of the relay and the frequency converter. The frequency converter acts in engine speed of pump firing of condenser cooling tower, while the relay operates directly into the burner of the generator, consecutively in thermal power of combustion. The control system can act in any pressure reference values above the zone of crystallization of absorption cooling system. In the control flow control techniques were used and fuzzy Modeling and control power thermal combustion, on-off control. Ten different experiments were conducted, which proved the efficiency of the system of control. / Neste trabalho apresenta-se o estudo teórico e experimental de um sistema de controle para um gerador de vapor. Este sistema foi desenvolvido para controlar a cristalização de um sistema de refrigeração por absorção. O sistema de controle mantém a pressão do gerador acima da zona de cristalização do diagrama temperatura-pressãoconcentração de solução saturadas do LiBr-água. O controle é realizado por meio do uso simultâneo do relé e o conversor de freqüência. O conversor de freqüência atua na velocidade do motor de acionamento da bomba da torre de resfriamento do condensador, enquanto o relé opera no queimador do gerador, consecutivamente na potência térmica de combustão. O sistema de controle pode atuar em quaisquer valores de referência de pressão acima da zona de cristalização do sistema de refrigeração por absorção. No controle da vazão foram utilizados técnicas de controle e modelagem Fuzzy e para controlar a potência térmica combustão, o controle on-off. Foram realizados dez experimentos diferentes, que comprovam a eficiência do sistema de controle.