Estudo de estratégias de rastreamento da corrente e da tensão de saída CA de um conversor do tipo fonte de tensão. / Output voltage and current tracking strategies of a voltage source converter.

Martinz, Fernando Ortiz 28 September 2007 (has links)
Este trabalho apresenta algumas estratégias de controle das malhas de rastreamento de tensão e corrente no lado CA de conversores do tipo fonte de tensão com filtro L ou LC. A topologia escolhida para o controle de tensão CA do inversor é a de duas malhas de controle em cascata: malha de tensão e malha de corrente, sendo esta última mais interna no sistema de controle. A metodologia de trabalho utilizada consiste na modelagem do sistema (sistema controlado e controladores), ajuste dos parâmetros do controlador, simulação computacional do sistema \"inversor + controlador\", implementação de alguns controladores propostos utilizando um DSP e testes em um sistema real com inversor. O estudo das técnicas de controle concentra-se inicialmente na estratégia de realimentação de dois estados no domínio de tempo contínuo, evoluindo para estratégias em tempo discreto que consideram o atraso na atuação do inversor devido ao tempo de cálculo do algoritmo de controle. Em tempo discreto, são analisados controladores preditivos para as malhas de tensão e corrente, bem como o emprego de controladores Proporcional-Integral (PI) na malha de tensão. Os dois últimos controladores são testados em um inversor PWM de baixa potência para diversos tipos de carga, com tensão de referência de inversor senoidal em 60Hz e referência contendo harmônicas. / This work presents some control strategies to achieve voltage and current tracking at the AC side of Voltage Source Converters with L or LC output filters. The topology of voltage control is the Multi-loop control with two loops: Voltage (outer loop) and Current Loop (inner loop). The proposed methodology consists in modeling the control system (plant and controllers), tuning of the controller parameters, simulating the complete system including inverter and controller, implementation of the proposed control strategies on a Digital Signal Processor (DSP) and tests in a power converter. The thesis is initially focused on a state variable continuous time controller with two states and then discrete-time strategies which consider the actuation delay due to the time required to evaluate the control algorithm are studied. In these discrete-time models, predictive controllers in voltage and current loops are analyzed, as well as the use of Proportional- Integral (PI) controllers in the Voltage Loop. These two last control topologies are tested in a low-power inverter for several load conditions with sinusoidal 60Hz inverter reference voltage and with harmonic distortion in the inverter reference voltage.
2

Estudo de estratégias de rastreamento da corrente e da tensão de saída CA de um conversor do tipo fonte de tensão. / Output voltage and current tracking strategies of a voltage source converter.

Fernando Ortiz Martinz 28 September 2007 (has links)
Este trabalho apresenta algumas estratégias de controle das malhas de rastreamento de tensão e corrente no lado CA de conversores do tipo fonte de tensão com filtro L ou LC. A topologia escolhida para o controle de tensão CA do inversor é a de duas malhas de controle em cascata: malha de tensão e malha de corrente, sendo esta última mais interna no sistema de controle. A metodologia de trabalho utilizada consiste na modelagem do sistema (sistema controlado e controladores), ajuste dos parâmetros do controlador, simulação computacional do sistema \"inversor + controlador\", implementação de alguns controladores propostos utilizando um DSP e testes em um sistema real com inversor. O estudo das técnicas de controle concentra-se inicialmente na estratégia de realimentação de dois estados no domínio de tempo contínuo, evoluindo para estratégias em tempo discreto que consideram o atraso na atuação do inversor devido ao tempo de cálculo do algoritmo de controle. Em tempo discreto, são analisados controladores preditivos para as malhas de tensão e corrente, bem como o emprego de controladores Proporcional-Integral (PI) na malha de tensão. Os dois últimos controladores são testados em um inversor PWM de baixa potência para diversos tipos de carga, com tensão de referência de inversor senoidal em 60Hz e referência contendo harmônicas. / This work presents some control strategies to achieve voltage and current tracking at the AC side of Voltage Source Converters with L or LC output filters. The topology of voltage control is the Multi-loop control with two loops: Voltage (outer loop) and Current Loop (inner loop). The proposed methodology consists in modeling the control system (plant and controllers), tuning of the controller parameters, simulating the complete system including inverter and controller, implementation of the proposed control strategies on a Digital Signal Processor (DSP) and tests in a power converter. The thesis is initially focused on a state variable continuous time controller with two states and then discrete-time strategies which consider the actuation delay due to the time required to evaluate the control algorithm are studied. In these discrete-time models, predictive controllers in voltage and current loops are analyzed, as well as the use of Proportional- Integral (PI) controllers in the Voltage Loop. These two last control topologies are tested in a low-power inverter for several load conditions with sinusoidal 60Hz inverter reference voltage and with harmonic distortion in the inverter reference voltage.
3

Synthetic testing of high voltage direct current circuit breakers

Cwikowski, Oliver January 2016 (has links)
The UK is facing two major challenges in the development of its electricity network. First, two thirds of the existing power stations are expected to close by 2030. Second, is the requirement to reduce its CO2 emissions by 80% by 2050. Both of these challenges are significant in their own right. The fact that they are occurring at the same time, generates a significant amount of threats to the existing power system, but also provides many new opportunities. In order to meet both these challenges, significant amounts of offshore wind generation has been installed in the UK. For the wind generation with the longest connections to land, Voltage Source Converter (VSC) based High Voltage Direct Current (HVDC) transmission has to be used. Due to the high power rating of the offshore wind farms, compared to the limited transmission capacity of the links, a large number of point-to-point connections are required. This has lead to the concept of HVDC grids being proposed, in order to reduce the amount of installed assets required. HVDC grids are a new transmission environment and the fundamental question of how they will protect themselves must be answered. Several new technologies are under consideration to provide this protection, one of which is the HVDC circuit breaker. As HVDC circuit breakers are a new technology, they must be tested in a laboratory environment to prove their operation and improve their Technology Readiness Level (TRL). This thesis is concerned with how such HVDC circuit breakers are operated, rated, and tested in a laboratory environment. A review of the existing circuit breaker technologies is given, along with descriptions of several novel circuit breakers developed in this thesis. A standardized method of rating DC circuit breaker and their associated test circuit is developed. Mathematical analysis of several circuit breakers is derived from first principles and low power prototypes are developed to validate these design concepts. A high power test circuit is then constructed and a semiconductor circuit breaker is tested. The key learning outcomes from this testing are provided.
4

Modelagem e controle de um reator eletrônico para lâmpadas HPS baseado na conexão diferencial de conversores CC / Modeling and control of an electronic ballast for HPS lamps based on differential connection of DC converters

Hansen, Jacson 28 February 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This paper presents the development of an electronic ballast for high intensity discharge lamps, using the differential connection technique applied to Flyback converters. The power factor correction stage was implemented by a Buck-Boost converter operating in discontinuous conduction mode. Subsequently, the integrating converters technique was used to simplify the power circuit, making the power factor correction stage and Flyback converters share the same active switches. The proposed circuit was dynamically modeled, in order to obtain the mathematical parameters that govern the behavior of the ballast, obtaining the differential equations relating the voltage and current in the lamp, due to the variation of both the input voltage as the duty cycle. Digital control of the output current provided the use of a low cost microcontroller, the compensating system was designed in discrete time from the use of an integrator and a low frequency bandwidth. For effective control of lamp power, an external loop that regulates the circuit current reference was implemented. The practical implementation of the electronic ballast was performed, in order to verify the proposed control performance. / Este trabalho apresenta o desenvolvimento de um reator eletrônico para alimentar lâmpadas de descarga em alta pressão, utilizando a técnica de conexão diferencial aplicada aos conversores Flyback. A etapa de correção de fator de potencia foi implementada através de um conversor Buck-Boost operando em modo de condução descontinuo. Posteriormente, foi utilizada a técnica de integração de conversores para simplificar o circuito de potência, fazendo com que a etapa de correção do fator de potencia e os conversores Flyback compartilhassem os mesmos interruptores ativos. O circuito proposto foi modelado dinamicamente a fim de obter os parâmetros matemáticos que regem o comportamento do reator, obtendo as equações diferenciais referentes à tensão e corrente na lâmpada, em função da variação, tanto da tensão de entrada como da razão cíclica. O controle digital da corrente de saída proporcionou a utilização de um dispositivo microcontrolado de baixo custo, sendo o compensador do sistema projetado em tempo discreto a partir da utilização de um integrador e uma banda passante de baixa frequência. Para o efetivo controle da potência na lâmpada foi adicionada uma malha externa que regula a referência de corrente do circuito. Foi realizada a implementação prática do reator eletrônico a fim de verificar a performance do controle proposto.