• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The rates of acid hydrolysis of the beta-D-glucopyranosiduronic acids and beta-D-glucopyranosides of phenol, para-cresol, and para-chlorophenol.

Semke, Leon K. 01 January 1963 (has links)
No description available.
2

Oxidation of phenol and cresol by electrochemical advanced oxidation method in homogeneous medium : application to treatment of a real effluent of aeronautical industry

Pimentel, Marcio 24 September 2008 (has links) (PDF)
The present work verified the efficiency of electro-Fenton to destroy phenolic compounds present in Stripping Aircraft Wastewater. This research aimed to elucidate the influence of the catalyst nature, its concentration and of electric current density in efficiency of electro-Fenton process using an indivisible cell with a carbon felt cathode and platinum or borod doped diamond anodes. The experiments compared the effect of these variables to destroy phenol, cresols and their intermediates. The compounds and many intermediates formed were identified in High Perfomance Liquid Chromatograph and allowed obtaining apparent and/or absolute constants and simplified degradation mechanisms. In optimum conditions, measures of Total Organic Carbon showed high mineralization rates. At the end, the application of electro-Fenton process to high organics loads of real Stripping Aircraft wastewater allowed obtaining almost complete mineralization replacing Pt anode by Boron Doped Diamond.
3

Oxidation of phenol and cresol by electrochemical advanced oxidation method in homogeneous medium : application to treatment of a real effluent of aeronautical industry / Études de l'oxydation du phénol et du crésol par l'oxydation électrochimique avancée en milieu homogène : application au traitement d'un effluent réel de l'industrie aéronautique

Pimentel, Marcio 24 September 2008 (has links)
L'oxydation du phenol et des cresols en milieu aqueux par le procédé électro-Fenton en utilisant une cathode en feutre de carbone a été étudiée. 10?4 M de sulfate de fer (II) a été la concentration optimale de catalyseur, permettant d'éliminer 100% du carbone organique total (Cot) de solutions aqueuses de phenol. Les principaux intermédiaires formés (70%) au cours de la destruction du phenol ont été identifiés comme l'hydroquinone, p-benzoquinone et le catechol. Au cours de l'électrolyse de l'o-cresol, les intermédiaires identifiés (58%) ont été le 3-méthyl-catechol et le méthyl-hydroquinone. Pendant l'oxydation de phenols, les acides prédominants ont été identifiés. Ces expériences ont permis de proposer un mécanisme complet de minéralisation pour le phenol et l'o-cresol. Au cours du traitement des rejets de décapage d'avions, le remplacement des anodes de PT par diamant dope bore a augmenté l'efficacité, en supprimant environ 98% de TOC en 20 heures / The present work verified the efficiency of electro-Fenton to destroy phenolic compounds present in Stripping Aircraft Wastewater. This research aimed to elucidate the influence of the catalyst nature, its concentration and of electric current density in efficiency of electro-Fenton process using an indivisible cell with a carbon felt cathode and platinum or borod doped diamond anodes. The experiments compared the effect of these variables to destroy phenol, cresols and their intermediates. The compounds and many intermediates formed were identified in High Perfomance Liquid Chromatograph and allowed obtaining apparent and/or absolute constants and simplified degradation mechanisms. In optimum conditions, measures of Total Organic Carbon showed high mineralization rates. At the end, the application of electro-Fenton process to high organics loads of real Stripping Aircraft wastewater allowed obtaining almost complete mineralization replacing Pt anode by Boron Doped Diamond.
4

Caracterizacao de compostos quimicos para dosimetria das radiacoes em processos industriais

GALANTE, ANA M.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:45Z (GMT). No. of bitstreams: 1 06646.pdf: 4877971 bytes, checksum: e62f747f9cf9d486a0b537873504da8e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
5

Caracterizacao de compostos quimicos para dosimetria das radiacoes em processos industriais

GALANTE, ANA M.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:45Z (GMT). No. of bitstreams: 1 06646.pdf: 4877971 bytes, checksum: e62f747f9cf9d486a0b537873504da8e (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
6

Desenvolvimento e validação de método para a extração e quantificação de compostos fenólicos em sedimento. Estudo de caso: Reservatório Guarapiranga, SP / Development and validation method for extraction and quantification of phenolics compounds in sediment. Case study: Reservoir Guarapiranga, SP

ADAME, GISELE 21 December 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-12-21T15:41:03Z No. of bitstreams: 0 / Made available in DSpace on 2016-12-21T15:41:03Z (GMT). No. of bitstreams: 0 / Compostos fenólicos vêm despertando preocupação nos últimos anos e incitando grande atenção em todo o mundo ao desenvolvimento de métodos de determinação e monitoramento contínuo no ambiente devido a sua elevada toxicidade e persistência no meio ambiente, principalmente no sedimento, que devido sua característica em acumular compostos faz desse um dos compartimentos mais importantes na avaliação do nível de contaminação de ecossistemas aquáticos continentais. Neste estudo foi desenvolvido um método analítico utilizando cromatografia a gás acoplada ao detector de espectrometria de massas (GC/MS) para a determinação de seis compostos fenólicos e foi avaliada a presença dos mesmos em amostras de sedimento do Reservatório Guarapiranga, um reservatório de usos múltiplos da água, destinado principalmente para abastecimento público de água potável da Região Metropolitana de São Paulo. Para garantir a reprodutibilidade do método de forma confiável atendendo aos objetivos e qualidade propostos, a metodologia desenvolvida foi submetida ao processo de validação, em que os parâmetros seletividade, linearidade, faixa de trabalho, limite de detecção, limite de quantificação, tendência/recuperação, precisão (repetitividade, precisão intermediária e reprodutibilidade) e robustez foram avaliados. A metodologia aqui proposta mostrou ser adequada para alcançar o objetivo de avaliar os compostos em estudo, e pela sua aplicação foi constatada a presença dos compostos fenol e 3-metilfenol no sedimento do reservatório. Nas amostras de sedimento coletadas em 2011, o fenol foi o composto encontrado com maior frequência, com alguns resultados acima do LQ, principalmente em pontos com maior influência urbana, em concentrações de 0,09 a 0,19 μg g-1. Também foi encontrado o 3-metilfenol com resultados acima do LQ em dois pontos de coleta, G-11 e G-13, nas concentrações de 0,10 e 0,19 μg g-1 respectivamente. Já na coleta realizada em outubro de 2014, o composto 3-metilfenol foi quantificado em dois pontos de coleta, G-02 e G-07, nas concentrações de 0,07 e 0,08 μg g-1 respectivamente, sendo detectado abaixo do LQ em diversos pontos ao longo do reservatório. A presença destes compostos mesmo em baixas concentrações pode indicar uma contaminação decorrente de atividades industriais nas margens do reservatório e considerando-se que os compostos em sedimento com o tempo podem ser liberados na coluna dágua e causar contaminação na água de abastecimento este estudo fornece subsídios para revisão da legislação vigente que não estabelece limites para os compostos fenólicos na matriz de estudo. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1441 seconds