DESIGN AND CONSTRUCTION OF HEAT EXCHANGER TEST STAND WITH INITIAL TEST RESULTS

Albrecht, Daniel David 01 December 2009 (has links)
Continual development of internal combustion engines requires greater performance from liquid coolants and heat exchangers to maintain optimal temperature. For the purpose of experimental testing of traditional, compact, and microchannel heat exchangers, a test facility has been designed, constructed, and utilized. The facility includes equipment and instrumentation necessary to create operating conditions and record data primarily for testing plate-fin brazed aluminum heat exchanger where heat is being transferred from liquid to air. Other arrangements of heat exchangers could be tested as well with some modifications. Initial tests were performed at several specified operating conditions for three liquids: water, a traditional glycol based Extended Life Coolant (ELC), and a new Glycol Free Coolant (GFC) in an attempt to characterize their heat transfer ability. Results of the tests found that the product of overall heat transfer coefficient and heat exchanger area (UA) was very similar for GFC and water, and it was less for ELC by a narrow margin of 1.3% difference on average. Uncertainty due to instrumentation accuracy was calculated to be 1.8% on average making the results overall UA unverifiable. Measured pressure drop across the heat exchanger which is proportional to required pumping power was found to be 13.5% higher for GFC than ELC at nominal conditions. The GFC offers similar heat transfer performance and marginally increased pumping power requirements compared to the traditional ELC. Due to similar heat transfer performance and the small effect of pressure drop, GFC would be good alternative to ELC due to its less toxic composition.
2

Design and performance of a small scale waste heat recovery unit

Ward, Christopher 05 December 2011 (has links)
A microchannel heat exchanger was designed for diesel waste heat recovery and its performance was evaluated. The 21x15x8 cm unit was constructed from diffusion brazed stainless steel lamina and weighed 11 kg. Operating from a 13.4 kW generator with an exhaust temperature of 500 °C the unit delivered 11.1 kW of thermal energy at the design point with an effectiveness of 0.87. If coupled with an organic Rankine bottoming cycle this has the potential of boosting system power output by 35%. Performance was found to be insensitive to cold side flow conditions. Soot accumulation was found to be problematic, which caused a steady exhaust pressure rise at the device but did not affect the thermal performance. / Graduation date: 2012