Spelling suggestions: "subject:"dental implants"" "subject:"dental iomplants""
31 |
On immediate/early loading of implant-supported prostheses in the maxilla /Fischer, Kerstin, January 2008 (has links)
Diss. (sammanfattning) Göteborg : Univ. , 2008. / Härtill 5 uppsatser.
|
32 |
Factors affecting peri-implant tissue reactions /Hultin, Margareta, January 1900 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2001. / Härtill 5 uppsatser.
|
33 |
The development of a biological interface for transition metal implantsMelton, Kim R. January 1998 (has links)
Thesis (Ph. D.)--University of North Carolina at Chapel Hill, 1998. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
34 |
Comparison of spiral tomography (Scanora) with ridge mapping and plain film radiography for dental implant planning in partially dentate jaws /Cheung, Tak-sum, Thomas. January 2002 (has links)
Thesis (M.D.S.)--University of Hong Kong, 2002. / Includes bibliographical references (leaves 127-139).
|
35 |
Comparison of spiral tomography (Scanora) with ridge mapping and plain film radiography for dental implant planning in partially dentate jawsCheung, Tak-sum, Thomas. January 2002 (has links)
Thesis (M.D.S.)--University of Hong Kong, 2002. / Includes bibliographical references (leaves 127-139). Also available in print.
|
36 |
Plataforma regular versus switching: estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e internoFreitas Júnior, Amilcar Chagas [UNESP] 30 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-06-30Bitstream added on 2014-06-13T20:25:50Z : No. of bitstreams: 1
freitasjunior_ac_dr_araca.pdf: 626707 bytes, checksum: 01bcfeff181d77eb6eaa682b52483519 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... / Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below)
|
37 |
Analise histologica e histomorfometrica do reparo osseo perimplantar em cães submetidos a instalação de implantes endosseos com um modelo de carga precoce em dois diferentes desenhos de implantes / Histological and histomorphometric analysis of perimplant osseous repair in dogs submitted to endosseous implant installation with early load model in two different implant designOlate Morales, Sergio Adrian 02 December 2009 (has links)
Orientador: Jose Ricardo de Albergaria-Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:32:19Z (GMT). No. of bitstreams: 1
OlateMorales_SergioAdrian_M.pdf: 2518502 bytes, checksum: 379ec7fb825eca639d7e7c3aa4e052a8 (MD5)
Previous issue date: 2009 / Resumo: Diferentes protocolos para a reabilitação com prótese implanto assistida têm sido reportados. Deles, é possível que a carga imediata em implantes unitários sejam um dos mais controversos. O objetivo deste estudo foi estabelecer quantitativamente as características de reparo ósseo em implantes submetidos a um modelo de carga precoce. Foi desenvolvido um modelo experimental em cães para a avaliação de dois protocolos de instalação de implantes dentais com dois desenhos diferentes. Foi realizada a exodontia dos pré-molares bilaterais mandibulares dos animais e após de três meses foi realizada a instalação de dois implantes bilateriais. No implante mesial foi realizada a instalação do parafuso cicatrizador de 7 mm (modelo de carga imediata unitária sem contato oclusal) e no implante distal foi instalado o parafuso cobertor (técnica de implante submerso). Cada hemimandíbula recebeu um implante cilíndrico (Neodent Titamax CM®) e um implante cônico (Conexão Conect Ar®) com seu parafuso cicatrizador. Inicialmente os primariamente foram avaliados com microscopia eletrônica de varredura. Os sacrifícios dos animais foram após de três e seis semanas. Os blocos foram descalcificados e processados para análise com histológica descritiva e histomorfométrica. Foi aplicado o teste estatístico t teste para variáveis independentes com nível de significância de 5%. De forma geral, os implantes apresentaram maior formação óssea no nível cervical e menor no nível apical. Os resultados demonstram também maior formação óssea em implantes com o modelo de carga precoce que em aqueles sem carga, com ausência de diferença estatística. Por outra parte, os implantes cônicos apresentaram maior formação óssea que os cilíndricos, também sem significância estatística. Concluiu-se que os implantes com instalação do parafuso cicatrizador, como modelo de restauração imediata sem contato oclusal, apresenta maior quantidade óssea nos vales quando comparados aos implantes não submetidos a carga / Abstract: Several treatment types using prosthesis over implants have been reported, being the singles immediate loading therapy with more controversy. The meaning of the present study is established the characteristics of bone repair in dental implant submitted to immediate loading. It was performed a experimental model using dogs to value two different installations protocols of dental implants. It was done the extraction of the bilateral premolars of the jaw, installing the dental implants after 3 months of healing. The anterior implant was submitted to healing screw install of 7 mm (unitary immediate load model without oclusal contact) and the posterior ones were covered with cove screrw (immerse implant technique). Each hemi-jaw presented one cylindrical (Neodent Titamax CM®) or conical (Conexão Conect Ar®) with with anterior or posterior position, that was evaluated with scanning electron microscopy. The sacrifices were performed on three and six months. The specimens were decalcified and processed to begging its histological evaluation using descriptive and histomorphometric analyses. The statistical test T test was performed using significance index of 5%. In general, dental implants showed more bone formation on cervical region and less on apical area. The results demonstrated more bone formation on the immediate loading types, with no statistical significance. The conical ones presented more bone formation that cylindrical, but without statistical significance. This way it is possible to conclude that implants with immediate installation of healing screw, how immediately load model without oclusal contact (immediately restauration), have more osseous presence when compared to non load implant / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
|
38 |
Avaliação do comportamento mecanico de proteses fixas implantossuportadas por meio da tecnica de extensometria eletrica / Evaluation of mechanic behavior of fixed prosthesis implantsupported by means of electric extensometry technicPrado, Devanir Silva Vieira, 1951- 13 August 2018 (has links)
Orientador: Wilkens Aurelio Buarque e Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T01:38:34Z (GMT). No. of bitstreams: 1
Prado_DevanirSilvaVieira_M.pdf: 895028 bytes, checksum: fe09fdf9bad8a966f0302b161600791e (MD5)
Previous issue date: 2009 / Resumo: Muitas vezes, as tensões são causadas por alterações nas adaptações das estruturas protéticas ao implante, além dos desajustes marginais entre as fixações e as reabilitações protéticas. Este trabalho tem como objetivo, avaliar a distribuição de compressão e tração dos pilares protéticos e infra-estrutura metálica fundida em liga de cobalto-cromo, pela técnica de monobloco, simulando uma prótese fixa implantossuportadas sobre 06 implantes com distância de 10 mm entre implantes e com extremo livre (cantilever) bilateral com extensão de 20 mm, colocados através da curvatura da linha oclusal mandibular. Em cada pilar foram colados quatro extensômetros e um em cada cantilever, após o apertamento de todos pilares e a infra-estrutura aos implantes, foi submetido a um ensaio mecânico com cargas compressivas verticais de 150 N, analisando quantitativamente os resultados bem precisos através da extensometria. Os resultados foram obtidos usando os maiores valores de carga axial registrados em cada ponto de força aplicado, registrando deformação para infra-estrutura, pilares e os cantilevers. Com aplicação de carga nos pontos entre os pilares, foi obtido nos pilares mais próximos a aplicação da carga um maior grau de compressão e nos pilares mais distantes, em menor grau de acordo com a distribuição de carga deformação por compressão e ou/ tração. Com aplicação de carga vertical máxima no cantilever, o pilar adjacente foi o mais solicitado por compressão, independente do ponto de aplicação da carga e o último pilar do lado oposto em menor intensidade, também solicitado por compressão, formando um eixo de rotação, no qual os componentes anteriores foram solicitados em regime de tração (alavanca). O carregamento mecânico registrou deformação para a infraestrutura, pilares e cantilever. / Abstract: Frequently, stresses are caused by changes in adaptations of prosthetic structures to the implant besides marginal disajustment between prosthetic fixing and rehabilitations. This study aims to evaluate the distribution of compression and traction of the prosthetic sustainers and the methalic framework melted in cromocobalt alloy, through the monoblock technic simulating a fixed prosthesis implantsupported on 06 implants at the distance of 10mm between each other and with bilateral cantilever extending to 20mm, placed along the mandibular oclusal line curvature, with the extensometry technic. In each abutment there have been placed four strain guages and one in each cantilever, in configuration "Wheatstone Bridge", after all components having been fixed to the framework, it was submitted to a mechanic essay with vertical pressing charges of 150Ncm, checking quantitatively the accurate result through extensometry. Results have been obtained by using the greatest values of axial charge registered in each place of applied force,. On nearest pillars to the charge, It has been obtained a greater degree of compression (fulcrum), what corresponds to the amount of oclusal force applied to the equalizing stress force. And, therefore, the most distant pillars will assimilate a negative deformation ( compression) or a positive deformation (traction, seesaw), proportional to the lever arm. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
39 |
Avaliação da regeneração ossea em defeitos peri-implantares de deiscencia tratados com uma abordagem combinada associando celulas derivadas da medula ossea e regeneração ossea guiada : estudo histomorfometrico em cães / Evaluation of bone regeneration in dehiscence type peri-implant defects treated with a combined approach using bone marrow-derived cells and guided bone regeneration : a histomorphometrical study in dogsRibeiro, Fernanda Vieira 12 September 2009 (has links)
Orientadores: Marcio Zaffalon Casati, Karina Gonzales Silverio Ruiz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:45:21Z (GMT). No. of bitstreams: 1
Ribeiro_FernandaVieira_D.pdf: 8018060 bytes, checksum: 8fc3b530db926d929facce5cfd30fb4e (MD5)
Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar histometricamente o reparo ósseo em defeitos periimplantares do tipo deiscência, criados cirurgicamente em cães, tratados com a associação de células derivadas da medula óssea (CMs) e regeneração óssea guiada (ROG). A medula óssea foi obtida a partir da crista ilíaca de oito cães beagle adultos machos. Células derivadas da medula óssea (CMs) foram isoladas, cultivadas in vitro e fenotipicamente caracterizadas com relação as suas propriedades osteogênicas. Os mesmos animais foram submetidos à extração bilateral dos primeiros molares e terceiro e quarto pré-molares inferiores. Após três meses, três leitos para a colocação de implantes foram confeccionados em cada lado da mandíbula, deiscências ósseas vestibulares foram criadas e, então, implantes de titânio de superfície usinada foram colocados. As deiscências ósseas foram tratadas aleatoriamente, de acordo com um dos seguintes grupos: 1) ROG+CMs+C: membrana de PTFE-e com reforço de titânio associada às células derivadas da medula óssea semeadas no carreador, 2) ROG+C: membrana de PTFE-e com reforço de titânio associada ao uso do carreador sem células, 3) CMs+C: células derivadas da medula semeadas no carreador, 4) ROG: membrana de PTFE-e com reforço de titânio, 5) C: carreador sem células e 6) Controle: nenhum tratamento. Após três meses, os animais foram sacrificados e os implantes em conjunto com os tecidos adjacentes foram processados laboratorialmente para obtenção de secções não descalcificadas. Os parâmetros avaliados foram: Contato direto osso-implante (CO), Preenchimento ósseo dentro das roscas do implante (PR) e Área de tecido ósseo fora das roscas (AF). In vitro, a caracterização fenotípica demonstrou que células derivadas da medula óssea apresentaram potencial osteogênico identificado pela formação de nódulos minerais e expressão de marcadores ósseos (fosfatase alcalina, sialoproteína óssea e colágeno tipo I). As análises histométricas revelaram que todos os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) demonstraram resultados estatisticamente similares (p>0,05) com relação à área de novo osso formado fora das roscas do implante, apresentando, no entanto, maior quantidade de osso neoformado fora dos limites das roscas, quando comparados aos demais grupos (CMs+C, C e Controle) (p<0,05). Adicionalmente, foi observado que o preenchimento ósseo dentro das roscas foi estatisticamente semelhante entre os grupos que utilizaram membrana (ROG+CMs+C, ROG+C, ROG) e o grupo tratado com células sem barreira (CMs+C) (p>0,05), enquanto todos estes grupos mostraram um preenchimento ósseo significativamente superior ao grupo Controle (p<0,05). Com relação à porcentagem de contato osso-implante, embora os defeitos tratados com membrana (ROG+CMs+C, ROG+C e ROG) tenham apresentado valores estatisticamente maiores quando comparados aos defeitos dos grupos C e Controle (p<0,05), uma tendência para aumento da extensão de contato osso-implante foi observada nos defeitos tratados com células sem a associação da ROG (grupo CMs+C). Dentro dos limites do presente estudo, pôde-se concluir que embora as células derivadas da medula óssea, utilizadas isoladamente, tenham promovido bons resultados em relação à formação óssea dentro das roscas do implante, o seu uso, associado à ROG, não promoveu benefícios adicionais na formação óssea em defeitos peri-implantares de deiscência. / Abstract: The purpose of this investigation was to histometrically evaluate the bone healing in surgically created dehiscence-type defects around titanium implants treated with an association of bone marrow-derived cells (BMCs) and guided bone regeneration (GBR). Bone marrow cells were harvested from eight male adult beagle dogs, cultured in vitro and phenotypically characterized with regard to their osteogenic properties. Following, the same animals were subjected to bilaterally teeth extraction (lower premolars and the first molar) and three months later, three implant sites were drilled in each side of mandible, buccal bone dehiscences were created and titanium dental implants with machined surface were placed. Dehiscences were randomly assigned to one of the following groups: 1) GBR+BMCs+C: PTFE-e barrier placement associated with BMCs into the carrier, 2) GBR+C: PTFE-e barrier placement associated with carrier, 3) GBR: PTFE-e barrier placement, 4) BMCs+C: BMCs into the carrier, 5) C: carrier without cells e 6) Control: no treatment. After 3 months, the animals were sacrificed and the implants in conjunction with adjacent hard tissues were processed for undecalcified sections. Bone-to-implant contact (BIC), bone filling within the limits of implant threads (BF) and new bone area (BA) in a zone lateral to the implant surface were obtained. Results: In vitro, phenotypic characterization demonstrated that BMCs presented osteogenic potential identified by the mineral nodule formation and the expression of bone markers. Histometrically, inter-group analysis demonstrated that all defects treated with GBR (GBR+BMCs+C, GBR+C and GBR) were statistically similar in terms of BA (p>0.05), presenting significantly higher BA as compared with other groups (BMCs+C, C and Control) (p<0.05). With respect the BF, no differences were observed among GBR+BMCs+C, GBR+C, GBR and BMCs+C groups (p>0.05), whereas all these groups showed statistically superior BF as compared to Control group (p<0.05). Additionally, although the percentage of BIC has been significantly higher in the defects treated by barrier membrane (GBR+BMCs+C, GBR+C and GBR) as compared to C and Control groups (p<0.05), a trend towards to a greater extension of BIC has been observed for the defects treated with BMCs+C. Within the limits of this study, it was concluded that although the use of bone marrowderived cells has provided promising outcomes in terms of bone formation within the limits of implant threads, their use, in combination with GBR, has not promoted additional benefits on the bone regeneration in peri-implantar dehiscence type bone defects. / Doutorado / Periodontia / Doutor em Clínica Odontológica
|
40 |
Avaliação da perda de pre-carga e infiltração bacteriana em sistemas de implantes de encaixe conico e hexagono externo / Evaluation of reload loss and bacterial penetration on conical and external hexagon connection implant systemsRicomini Filho, Antônio Pedro, 1983- 12 April 2009 (has links)
Orientador: Altair Antoninha Del Bel Cury / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-14T23:43:34Z (GMT). No. of bitstreams: 1
RicominiFilho_AntonioPedro_M.pdf: 1929547 bytes, checksum: 3218196794c582fbd092c07948036e16 (MD5)
Previous issue date: 2009 / Resumo: A presença de microrganismos na interface implante e pilar é um dos fatores associado ao insucesso de implantes osseointegrados. Sistemas de implantes de encaixe cônico visam precisa adaptação entre o implante e o pilar, entretanto não se sabe o comportamento desses sistemas frente a condições de estresse da cavidade oral quanto à manutenção da pré-carga e capacidade de selamento bacteriano. Assim, o objetivo deste estudo foi avaliar a perda de précarga e a infiltração bacteriana na interface implante e pilar de sistemas de encaixe cônico e hexágono externo, submetidos à ciclagem térmica e fadiga mecânica (CF). Foram utilizados 48 implantes de quatro sistemas de implante-pilar divididos em 8 grupos (n=6): (1) hexágono externo e munhão universal; (2) hexágono externo e munhão universal com CF; (3) cone morse e munhão universal; (4) cone morse e munhão universal com CF; (5) cone morse e munhão universal parafuso passante; (6) cone morse e munhão universal parafuso passante com CF; (7) cônica justaposição e pilar padrão; (8) cônica justaposição e pilar padrão com CF. Os implantes foram fixados em resina epóxica e os pilares acoplados, realizando a pré-carga. Os espécimes (implante-pilar) foram submetidos à ciclagem térmica de 1.000 ciclos a 5°C e 55°C, com permanência de 60 s em cada banho, e à fadiga mecânica de 1,0 milhão de ciclos, 1,0 Hz e 120 N. O ensaio de infiltração bacteriana foi realizado com o microrganismo Streptococcus sanguinis (NCTC 10904). Os espécimes foram imersos em meio Tryptic Soy + Yeast Extract (TY) contendo S. sanguinis e incubados a 37°C e 10% CO2 por 72 h. Os valores de destorque foram registrados e os pilares foram desacoplados. Cone de papel estéril foi esfregado na parte interna do implante, inserido em um tubo contendo meio TY estéril e incubado. A presença de infiltração bacteriana foi avaliada por meio da turbidez do caldo. Implantes e pilares foram avaliados por meio de MEV. Os dados de perda de pré-carga foram submetidos à análise de variância a 2 critérios e ao teste de Tukey. Todos os sistemas apresentaram maiores valores de destorque quando submetidos à CF (p<0,05). O sistema cone morse com munhão universal apresentou os maiores valores de destorque quando comparado aos demais sistemas (p<0,01). Todos os sistemas cônicos apresentaram infiltração bacteriana. Dentro das condições experimentais, o sistema cone morse com munhão universal apresentou os maiores valores de destorque e não foi observado relação entre a perda da précarga e infiltração bacteriana. / Abstract: The presence of microorganisms in the implant and abutment interface is one of the factors associated to the osseointegrated implant failures. Conical junction implant systems have aimed a precise fit between implant and abutment, however, the behavior of these systems it is not known when submitted to the stress environment as found in the oral cavity, related to the preload maintenance and bacterial seal ability. Thus, the aim of this study was to evaluate the preload loss and the bacterial penetration through the implant-abutment interface of conical and external hexagon connection systems, submitted to thermal cycling and mechanical fatigue (TM). Forty eight implants of four different implant-abutment systems were divided in 8 groups (n=6): (1) external hexagon and universal post; (2) external hexagon and universal post with TM; (3) morse taper and universal post; (4) morse taper and universal post with TM; (5) morse taper and universal post two pieces; (6) morse taper and universal post two pieces with TM; (7) locking taper and standard abutment; (8) locking taper and standard abutment with TM. The implants were embedded in epoxy resin and the abutments were connected, setting the preload. The assemblies (implant-abutment) were submitted to thermal cycling of 1.000 cycles at 5°C and 55°C, with a dwell time of 60 s each and to mechanical fatigue, 1.0 million cycles, 1.0 Hz, 120 N. Bacterial penetration assay was performed with Streptococcus sanguinis (NCTC 10904). The assemblies were immersed in Tryptic Soy + Yeast Extract (TY) broth containing S. sanguinis and incubated at 37°C and 10% CO2 for 72 h. Detorque values were recorded and the abutments were disconnected. Sterile paper points were rubbed on the inner part of the implant and inserted in a tube with sterile TY broth and incubated. The presence or absence of bacterial penetration was assessed by the broth turbidity. Implants and abutments were observed by SEM. The preload loss data was analyzed by two-way ANOVA, followed by Tukey test. All the screw systems showed higher detorque values when submitted to TM(p<0,05). The morse taper system with universal post showed the highest detorque values when compared with the other systems (p<0,01). All the conical systems showed bacteria penetration. Within these experimental conditions, the morse taper system with universal post showed the higher detorque values and no relation between the preload loss and the bacterial penetration was observed. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
Page generated in 0.0838 seconds