• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação entre a frequência de detecção dos ligamentos denteados na coluna cervical por meio de sequência volumétrica entre os equipamentos de ressonância magnética de 1,5 Tesla e 3,0 Tesla / Comparison between the frequency of detection of the dentate ligament in cervical spine by means of volumetric sequence between the magnetic resonance equipment of 1,5 Tesla and 3,0 Tesla

Seragioli, Rafael 18 May 2015 (has links)
Introdução: Os ligamentos denteados são extensões da pia-máter em cada lado da medula espinhal, totalizando cerca de 20 a 21 pares de estruturas fibrosas que se conectam com a dura-máter, ancorando a medula espinhal. Esses ligamentos são importantes referências anatômicas para cirurgias envolvendo estruturas no interior do canal vertebral e, portanto, muito bem conhecidos por cirurgiões que abordam o canal vertebral. No entanto, não encontramos a descrição deste ligamento em estudos de ressonância magnética (RM). Objetivo: Nosso objetivo foi avaliar a detecção dos ligamentos denteados na coluna cervical por meio de imagens de RM em sequências de aquisição volumétrica e com alta resolução espacial, e comparar a frequência de detecção desses ligamentos nos equipamentos de 1,5 Tesla e 3,0 Tesla. Resultados: Foram avaliados 116 exames de ressonância magnética da coluna cervical, sendo observada alta frequência de detecção dos ligamentos denteados na coluna cervical utilizando sequência volumétrica 3D COSMIC, tanto no equipamento de 1,5 Tesla quanto no equipamento de 3,0 Tesla. Não houve diferença estatisticamente significativa quando comparamos a frequência de detecção dos ligamentos entre os equipamentos de RM de 1,5T e 3,0 T. / Introduction: Denticulate ligaments are extensions of the pia mater on each side of the spinal cord, totaling about 20 to 21 pairs of fibrous structures that connect with the dura mater, anchoring the spinal cord. These ligaments are important anatomical references for surgeries involving structures inside the spinal canal and therefore well known to surgeons who approach the spinal canal. To our knowledge, there is no previous study on the feasibility to detect the denticulate ligaments using MRI. Objective: Our aim was to evaluate the detection of denticulate ligaments in the cervical spine using high resolution magnetic resonance imaging (MRI), and to compare the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla equipment. Results: We evaluated 116 MRI scans of the cervical spine and observed high frequency of detection of the denticulate ligaments in the cervical spine using the volumetric sequence 3D COSMIC on both the 1,5 Tesla and 3,0 Tesla MR equipments. There was no statistically significant difference in the frequency of detection of the ligaments between the MRI equipments.
2

Comparação entre a frequência de detecção dos ligamentos denteados na coluna cervical por meio de sequência volumétrica entre os equipamentos de ressonância magnética de 1,5 Tesla e 3,0 Tesla / Comparison between the frequency of detection of the dentate ligament in cervical spine by means of volumetric sequence between the magnetic resonance equipment of 1,5 Tesla and 3,0 Tesla

Rafael Seragioli 18 May 2015 (has links)
Introdução: Os ligamentos denteados são extensões da pia-máter em cada lado da medula espinhal, totalizando cerca de 20 a 21 pares de estruturas fibrosas que se conectam com a dura-máter, ancorando a medula espinhal. Esses ligamentos são importantes referências anatômicas para cirurgias envolvendo estruturas no interior do canal vertebral e, portanto, muito bem conhecidos por cirurgiões que abordam o canal vertebral. No entanto, não encontramos a descrição deste ligamento em estudos de ressonância magnética (RM). Objetivo: Nosso objetivo foi avaliar a detecção dos ligamentos denteados na coluna cervical por meio de imagens de RM em sequências de aquisição volumétrica e com alta resolução espacial, e comparar a frequência de detecção desses ligamentos nos equipamentos de 1,5 Tesla e 3,0 Tesla. Resultados: Foram avaliados 116 exames de ressonância magnética da coluna cervical, sendo observada alta frequência de detecção dos ligamentos denteados na coluna cervical utilizando sequência volumétrica 3D COSMIC, tanto no equipamento de 1,5 Tesla quanto no equipamento de 3,0 Tesla. Não houve diferença estatisticamente significativa quando comparamos a frequência de detecção dos ligamentos entre os equipamentos de RM de 1,5T e 3,0 T. / Introduction: Denticulate ligaments are extensions of the pia mater on each side of the spinal cord, totaling about 20 to 21 pairs of fibrous structures that connect with the dura mater, anchoring the spinal cord. These ligaments are important anatomical references for surgeries involving structures inside the spinal canal and therefore well known to surgeons who approach the spinal canal. To our knowledge, there is no previous study on the feasibility to detect the denticulate ligaments using MRI. Objective: Our aim was to evaluate the detection of denticulate ligaments in the cervical spine using high resolution magnetic resonance imaging (MRI), and to compare the frequency of detection of these ligaments in 1.5 Tesla and 3.0 Tesla equipment. Results: We evaluated 116 MRI scans of the cervical spine and observed high frequency of detection of the denticulate ligaments in the cervical spine using the volumetric sequence 3D COSMIC on both the 1,5 Tesla and 3,0 Tesla MR equipments. There was no statistically significant difference in the frequency of detection of the ligaments between the MRI equipments.

Page generated in 0.0771 seconds