1 |
Dependência angular de uma ressonância de transparência induzida eletromagneticamente: aplicação à velocimetria de átomos friosSANTOS, Fredson Braz Matos dos January 2005 (has links)
Made available in DSpace on 2014-06-12T18:07:20Z (GMT). No. of bitstreams: 2
arquivo7875_1.pdf: 957397 bytes, checksum: cb1ba821e9bb830d197ce21762031b04 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2005 / Neste trabalho, demonstramos como o efeito de transparência induzida eletromagneticamente pode ser aplicado à medida de temperaturas de àtomos frios. O princípio da técnica reside na sensibilidade que esta ressonância apresenta com relação ao ângulo entre os feixes de luz incidentes, no limite de baixas intensidades. Este efeito resulta do deslocamento Doppler residual que surge em uma transição de dois fótons devido ao ângulo introduzido entre os feixes. O método foi demonstrado utilizando um sistema de dois níveis degenerados de átomos de Césio resfriados e aprisionados numa armadilha magneto-óptica. A partir da medida desta dependência angular, foi possível estimar a temperatura da amostra, cujo resultado está em bom acordo com medidas feitas no mesmo sistema utilizando outros métodos
|
2 |
Estudo da resposta de monitores de radioproteção em feixes padronizados de radiação X, gama e beta. / Study of radiation detectors response in standard X, gamma and beta radiation beamsFernanda Beatrice Conceição Nonato 24 May 2010 (has links)
Foram estudadas as respostas de 76 detectores Geiger-Müller, 4 detectores semicondutores e 34 câmaras de ionização. Muitos deles foram calibrados em feixes de radiação gama (37Cs e 60Co) e alguns foram testados em feixes de radiação beta (90Sr+90Y e 204Tl) e X (N-60, N-80, N-100, N-150). Para os três tipos de radiação, foram obtidos os fatores de calibração dos instrumentos e foi estudada a dependência tanto energética como angular destes detectores. Para radiação gama e beta foi estudada a dependência angular para ângulos de 00 e ± 450. Foram ainda obtidas as curvas da resposta dos instrumentos em relação a uma varredura angular de 00 e ± 900, para radiação gama, beta e X. Também foram analisados os fatores de calibração obtidos para radiação beta em relação à radiação gama. Para radiação gama, dos 66 detectores Geiger-Müller estudados, 24 apresentaram resultados para a dependência energética de acordo com a recomendação internacional da ISO 4037-2 e 56 estão de acordo com a recomendação brasileira da ABNT 10011. As câmaras de ionização e os semicondutores estão de acordo com as recomendações nacional e internacional. Todos os instrumentos apresentaram dependência angular menor que 40%. Para radiação beta, os instrumentos apresentaram resultados insatisfatórios para a dependência energética e angular; Para radiação X, as câmaras de ionização apresentaram resultados para dependência energética de acordo com a recomendação nacional, e a dependência angular foi menor que 40%. / The response of 76 Geiger-Müller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams (37Cs and 60Co), and some of them were tested in beta radiation (90Sr+90Y e 204Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 00 and ± 450. The curves of the response of the instruments were obtained over an angle interval of 00 to ± 900, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Müller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence; For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%.
|
3 |
Estudo da resposta de monitores de radioproteção em feixes padronizados de radiação X, gama e beta. / Study of radiation detectors response in standard X, gamma and beta radiation beamsNonato, Fernanda Beatrice Conceição 24 May 2010 (has links)
Foram estudadas as respostas de 76 detectores Geiger-Müller, 4 detectores semicondutores e 34 câmaras de ionização. Muitos deles foram calibrados em feixes de radiação gama (37Cs e 60Co) e alguns foram testados em feixes de radiação beta (90Sr+90Y e 204Tl) e X (N-60, N-80, N-100, N-150). Para os três tipos de radiação, foram obtidos os fatores de calibração dos instrumentos e foi estudada a dependência tanto energética como angular destes detectores. Para radiação gama e beta foi estudada a dependência angular para ângulos de 00 e ± 450. Foram ainda obtidas as curvas da resposta dos instrumentos em relação a uma varredura angular de 00 e ± 900, para radiação gama, beta e X. Também foram analisados os fatores de calibração obtidos para radiação beta em relação à radiação gama. Para radiação gama, dos 66 detectores Geiger-Müller estudados, 24 apresentaram resultados para a dependência energética de acordo com a recomendação internacional da ISO 4037-2 e 56 estão de acordo com a recomendação brasileira da ABNT 10011. As câmaras de ionização e os semicondutores estão de acordo com as recomendações nacional e internacional. Todos os instrumentos apresentaram dependência angular menor que 40%. Para radiação beta, os instrumentos apresentaram resultados insatisfatórios para a dependência energética e angular; Para radiação X, as câmaras de ionização apresentaram resultados para dependência energética de acordo com a recomendação nacional, e a dependência angular foi menor que 40%. / The response of 76 Geiger-Müller detectors, 4 semiconductor detectors and 34 ionization chambers were studied. Many of them were calibrated with gamma radiation beams (37Cs and 60Co), and some of them were tested in beta radiation (90Sr+90Y e 204Tl) and X radiation (N-60, N-80, N-100, N-150) beams. For all three types of radiation, the calibration factors of the instruments were obtained, and the energy and angular dependences were studied. For beta and gamma radiation, the angular dependence was studied for incident radiation angles of 00 and ± 450. The curves of the response of the instruments were obtained over an angle interval of 00 to ± 900, for gamma, beta and X radiations. The calibration factors obtained for beta radiation were compared to those obtained for gamma radiation. For gamma radiation, 24 of the 66 tested Geiger-Müller detectors presented results for the energy dependence according to international recommendation of ISO 4037-2 and 56 were in accordance with the Brazilian ABNT 10011 recommendation. The ionization chambers and semiconductors were in accordance to national and international recommendations. All instruments showed angular dependence less than 40%. For beta radiation, the instruments showed unsatisfactory results for the energy dependence and angular dependence; For X radiation, the ionization chambers presented results for energy dependence according to the national recommendation, and the angular dependence was less than 40%.
|
4 |
Dependência angular do tempo de armazenamento de luz em um vapor de césioALMEIDA, Allan Johnes Ferreira de 24 February 2014 (has links)
Submitted by Daniella Sodre (daniella.sodre@ufpe.br) on 2015-04-07T14:07:13Z
No. of bitstreams: 2
DISSERTAÇÃO Allan Johnes de Almeida.pdf: 9151346 bytes, checksum: a11d1788f243fa1edac133c17f6affef (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-04-07T14:07:13Z (GMT). No. of bitstreams: 2
DISSERTAÇÃO Allan Johnes de Almeida.pdf: 9151346 bytes, checksum: a11d1788f243fa1edac133c17f6affef (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2014-02-24 / CAPES / As mem orias oticas coerentes via EIT (transpar^encia eletromagneticamente induzida) fazem
uso direto da troca entre coer^encia otica e coer^encia at^omica entre estados com longos
tempos de vida e t^em sido largamente estudadas em diferentes sistemas at^omicos. Neste
regime e poss vel armazenar um pulso de luz na coer^encia at^omica induzida pelos campos
("escrita"), e recuper a-lo posteriormente com a incid^encia de um campo de "leitura". O
tempo de armazenamento est a diretamente associado a taxa de descoer^encia at^omica, que
para o caso de feixes colineares, determina tamb em a largura espectral do sinal de EIT. Por
outro lado, a exist^encia de um pequeno ^angulo entre os feixes incidentes (campos de escrita)
leva a um forte alargamento do sinal de EIT e consequentemente uma alta taxa de descoer^
encia devido ao movimento at^omico. Neste trabalho investigamos experimentalmente,
de forma sistem atica, o processo de armazenamento de luz em fun c~ao do ^angulo entre os
feixes incidentes e relacionamos o tempo de armazenamento medido com a correspondente
largura espectral do sinal de EIT.
|
5 |
Determinação e análise da influência angular e eletrônica nas constantes de acoplamento nJCH em 2-X-4-t-butilcicloexanonas e 2-X-4-t-butilcicloexanóis (X=H, Me, F, Cl, Br) / Determination of NMR nJCH spin-spin coupling constants and analysis of their angular and electronic dependence in 2-X-4-t-butylcycloexanonas and 2-X-4-t-butylcycloexanols (X=H, Me, F, Cl, Br)Favaro, Denize Cristina, 1987- 17 August 2018 (has links)
Orientador: Claudio Francisco Tormena / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-17T19:41:15Z (GMT). No. of bitstreams: 1
Favaro_DenizeCristina_M.pdf: 2968237 bytes, checksum: 07a91d8f375b71e3ddc4d4c9b7818162 (MD5)
Previous issue date: 2011 / Resumo: A dissertação consiste de uma parte introdutória que versa sobre constantes de acoplamento JXH que seguem ou não uma relação de estrita dependência com o ângulo diedro, proposta por Karplus para JHH e por Aydin e Günther para JCH; apresentando como as interações hiperconjugativas afetam os valores das mesmas. Seguindo a estrutura da dissertação temos os resultados e discussão. Primeiro apresentamos a metodologia de HSQC-TOCSY-IPAP utilizada para determinação das constantes de acoplamento JCH. Posteriormente apresentamos uma racionalização para a diferença entre os acoplamentos JC2H6e para as cetonas cis/trans-2-X-4-t-butilcicloexanonas (X = H, Me, F, Cl e Br) e entre os alcoóis derivados. Mostramos, também, qual a influência do ângulo de ligação C2-C1-C6 na constante de acoplamento JC2H6e onde observamos que para a maioria dos compostos o valor de JC2H6e possui uma relação inversa com esse ângulo interno. Além disso, analisou-se o efeito das interações hiperconjugativas sC1-C6s*C2-Br, LP2(O)s*C1-C2 e LP3(X)s*C1-C2, onde as duas primeiras interações tornam mais efetiva a transmissão do acoplamento e a última retira densidade eletrônica do caminho a três ligações. Por fim, observamos a aplicabilidade das regras propostas por Marshall, Contreras e col. na racionalização da diferença dos valores de JC2H3a quando o heteroátomo ligado ao C2 se encontra na orientação axial ou equatorial / Abstract: It is presented an overview about heteronuclear coupling constants JXH and their strict dependence with the dihedral angle, as proposed by Karplus for JHH and by Aydin and Günther for JCH. It is also presented descriptions about the effects of hyperconjugative interactions on coupling constants and also on the HSQC-TOCSY-IPAP methodology for the measurements of long range heteronuclear coupling constants (JCH). The experimental values for JCH couplings obtained from HSQC-TOCSY-IPAP and rationalization of the difference between the JC2H6e for cis/trans-2-X-4-t-butylcyclohexanones and 2-X-4-t-butylcyclohexanols (X = H, Me, F, Cl and Br) based on the effects of bond angle C2-C1-C6 and hyperconjugative interactions involving the sC1-C6, LP2(O) and LP3(X) has been presented and discussed. The hyperconjugative interactions were studied with the Natural Bond Orbital (NBO) analyses. It was observed that interactions such as, sC1-C6s*C2-Br and LP2(O)s*C1-C2 increase the JC2H6e values and LP3(X)s*C1-C2 decreases this coupling constant values.
Furthermore, we observed the applicability of the rules proposed by Marshall and Contreras in the rationalization of the difference between values of JC2H3a when heteroatom on carbon C2 is in the axial or equatorial orientation / Mestrado / Quimica Organica / Mestre em Química
|
Page generated in 0.0577 seconds